Professional Documents
Culture Documents
LEGEND:
NCC: Node control card
FAN: Fan card (cooling)
RAC: Radio access card (supports the ODU/IRU)
DAC: Digital access card (user interfaces)
AUX: Auxiliary card (auxiliary data and alarm I/O)
NPC: Node protection card (NCC protection)
PCC: Power Converter Card
NCM: Node Convergence Module
Interface traffic options include:
Ethernet, E1/DS1, E3/DS3, STM1/OC3
Auxiliary data and alarm I/O
ETHERNET CONNECTIONS SETTING
On the Network & Internet setting, change the Ethernet setting.
(TCP/IPv4 – Obtain an IP address automatically)
Commissioning of the Aviat modules
Connect the Ethernet cable from the Laptop/ PC to the first Port as shown on the
picture below.
EAH-07-0161-101 ODU 300, 07GHz, TR156/161/168MHz, 7424-7488MHz, HI PWR, TX LOW 7GHz 161
EAH-07-0161-102 ODU 300, 07GHz, TR156/161/168MHz, 7582-7649MHz, HI PWR, TX HIGH 7GHz 161
EEH-07-0168-021 ODU 600, 07GHz, T-R 0161/0168MHz, 7499-7583MHz,TX LOW 7GHz 168
EEH-15-0420-011 ODU 600, 15GHz T-R 0420MHz, 14501-14648MHz, HP, TX LOW 15GHz 420
EEH-15-0420-012 ODU 600, 15GHz, T-R 0420MHz, 14921-15068MHz, HP, Tx HIGH 15GHz 420
Set the Frequencies depending on the Tx Freq Range (MHz).
Ensure for both Ends ( Far- End and Near- End) are configured with the
same Bandwidth / Modulation, Tx/Rx Spacing (MHz).
The Tx Frequency of one end is the Rx Frequency of the other end and
vice versa.
Once both ends of the transmission is well configured, the portal should display all items
in green as indicated below.
THANK YOU