Professional Documents
Culture Documents
GP-S070 Introduction
Drawing
Data logger
GP – S070
Introduction
GP – S070 1. GP-S070 Introduction
1-1. What is GP?
7 " Wide display,
16,777,216 colors, True Color .
GP – S070 1. GP-S070 Introduction
1-3. GP-S070 Features
Features
Features
GP-S070
200
3
4
1
Features
Features
USB
GP S 070 T 9 D 6
① ② ③ ④ ⑤ ⑥ ⑦
ITEM DESCRIPTION
① ITEM GP Graphic panel
② SERIES S S series
③ SCREEN SIZE 070 7 inch
④ DISPLAY UNIT T TFT Color LCD
⑤ COLOR 9 16,277,216 colors
⑥ POWER SUPPLY D 24VDC
6 RS232C, RS422, USB Device, USB Host, Ethernet
⑦ INTERFACE
7 RS232C, RS232, USB Device, USB Host, Ethernet
GP – S070 1. GP-S070 Introduction
1-5 Part description
DRAWING
MEMORY 16MB 16 MB 26 MB 10 MB
COMMUNICATION
RS 232 /RS 422 RS232 / RS 422
RS232 / RS 422
RS232 / RS 422
USB/Ethernet USB / CF / Ethernet USB / CF / Ethernet
GP – S070 2. Competitors comparison
2-4 Application
D Company
Automation packing machine
GP – S070 2. Competitors comparison
2-4 Application
1 WHITE-RED TXD+
2 RED TXD-
3 WHITE-GREEN RXD+
4 BLUE SG
5 WHITE-BLUE SG
6 GREEN RXD-
7 WHITE-BROWN SG
8 BROWN SG
PC GP
GP-S070
GP-S070
이전 시스템설정
BACK SYSTEM SETTING / ENVIRONMENT END
종료
모니터링Local Ethernet
환경설정 데이터 Screen Bright 진단기능
기능설정
GP-S070
이전
BACK시스템설정
SYSTEM \
SETTING
환경설정 / ENVIRONMENT / LOCAL ETHERNET 종료
END
시리얼설정 언어설정
Mac Address XX – XX - XX – XX - XX – XX
보조설정 시간설정
GP-S070
Gateway 210.124.100.250
Mac Address XX – XX - XX – XX - XX – XX
GP-S070
Demokits
3 TM4-N2RB
4 Ethernet cable
Cable
5 RS422-RS485 cable
GP – S070 4. Drawing
- Preparation for drawing
4-4. Act Condition screen 4-5. Monitoring screen 4-6. Manual monitoring screen
4-7. Setting input screen 4-8. Alarm checking screen 4-9. Alarm History screen
GP – S070 4. Drawing
4-1. Generate Project
① [Project]-[Open] or ①
Click “GP training materials.prj”
⑥
GP – S070 4. Drawing
4-6. Manual Operating Screen
PROTOCOL PORT
GP station : 0
Flickers when power on at first
Indicator Communicati
LED on speed
CH1
CH1 LED 2400bps
9600/19200/38400
BAUD RATE 38400 CH2 LED 4800bps
Selectable
DATA LENGTH 8 CH3 LED 9600bps
TIP
GP – S070 4. Drawing
4-2. Main Screen
①
Drawing
① [Draw]-[Rectangle] or ②
select in tool bar
④
GP – S070 4. Drawing
4-2. Main Screen
Text
① [Draw]-[Text] or
Select in tool bar ②
④
GP – S070 4. Drawing
4-2. Main Screen
① [Draw]-[Touch key] or
select in tool bar
③
GP – S070 4. Drawing
4-2. Main Screen
④
Practice
Draw the screen switching key of ‘6’ and ‘7’
right empty space.
TIP
GP – S070 4. Drawing
4-3. Overlap
②
①
① Make the date and time tag and set current time
② Overlap screen setting
GP – S070 4. Drawing
4-3. Overlap
Date, Time
①
① [Draw]-[Clock] or
select in tool bar
④ ⑤
GP – S070 4. Drawing
4-3. Overlap
Overlap setting ①
① Select ‘B-3’ in workspace
④
『 Tip 』
- When selecting the background not ④ ⑤
objects, overlap screen will be selected.
- In[View]-[Overlap screen list], able to After overlap setting
edit or delete the overlap screen.
GP – S070 4. Drawing
4-4. Act Condition
③
④
①
① [Draw]-[Numeral Display] or
select in tool bar
②
② Select the shape and color in Basic tab
Frame : Color of line at the edge
in indicating screen
③
Plate : Background color in numeral
screen
③ Designate device
Channel : Connected device [CH1 TM4_Mod_A]
Station : Connected station [ 1 ] Color
Basic color(B) :
Address : Memory Address [ 301001 ]
TM4 communication
manual
GP – S070 4. Drawing
4-4. Act Condition
①
Numeral Display tag 2
① [Draw]-[Numeral display] or
select in tool bar
②
② Select the shape and color in Basic tab
Frame : Color of line at the edge
in indicating screen
Plate : Background color in numeral ③
screen
Color
③ Designate device Basic color(B) :
Channel : Internal device [ INTERNAL ]
Address : Memory Address [ C130 ]
④
⑤ Designate Font Size as 2 X 2
Input(Toggle Key)
X2 : Defective item’s qty +1
X0 : Passed item’s qty +1
X3 : Defective item reset
X1 : Passed item reset
GP – S070 4. Drawing
4-4. Act Condition
Panel meter
①
① [Draw]-[Panel meter] or
select in tool bar
② Designate device
Channel : Internal device[ INTERNAL ]
Address : Memory Address [ D1002 ] ②
Panel meter
⑤
GP – S070 4. Drawing
4-4. Act Condition
①
Bar graph
① [Draw]-[Line/Trend/Bar] or
select in tool bar
②
② Select Bar graph in Basic tab
Bar graph
④ Designate device
Channel : Internal device [ INTERNAL ] ④
Address : Memory Address [ D1003 ]
⑤
GP – S070 4. Drawing
4-5. Monitoring
③
①
①
Lamp 1
① [Draw]-[Lamp] or
select in tool bar
TM4 Communication
manual
GP – S070 4. Drawing
4-5. Monitoring
Lamp 1
④
GP – S070 4. Drawing
4-5. Monitoring
Lamp 1
⑤
GP – S070 4. Drawing
4-5. Monitoring
①
램프 2
① [Draw]-[Lamp] or
select in tool bar
②
Lamp 2
Part : The function for applying it to part display, lamp, touch key tag after registering the object which user wants
Ex) When the image file part is registered
TIP
GP – S070 4. Drawing
4-5. Monitoring
Lamp 3
①
① [Draw]-[Lamp] or
select in tool bar
②
② Set the Basic tab
Designate device
Channel : Connected device [CH1 TM4_Mod_A]
Station : Connected station [ 1 ]
Address : Memory Address [ 100001 ]
Shape : Part
TM4 Communication
manual
GP – S070 4. Drawing
4-5. Monitoring
Lamp 3
③
③ Set ON, OFF shape in Bit tab
④
GP – S070 4. Drawing
4-5. Monitoring
①
Comment display
① [Draw]-[Comment Display] or
select in tool bar
②
② Set the Basic tab
Device : Word
Channel : Connected device [INTERNAL]
Address : Memory Address [ D2000 ]
Vector Font: 16 Size
GP – S070 4. Drawing
4-5. Monitoring
Comment Display
③
③ Set the start number and color in Word tab
Start Number : displayed gradually according to
the number of device
Comment Display
⑤
⑤ Place the Comment display tag
GP – S070 4. Drawing
4-6. Manual monitoring
①
Touch key 1
① [Draw]-[Touch key] or
select in tool bar
②
② Set the Basic tab
Display Trigger: Bit
Channel : Connected device [CH1 TM4_Mod_A]
Station : Connected station [ 1 ]
Address : Memory Address [ 000001 ]
Shape : Graphic Library
GP – S070 4. Drawing
4-6. Manual monitoring
Touch key 1
③
③ Set ON, OFF shape in Form tab
④ In Action tab,
Channel : Connected device [CH1 TM4_Mod_A]
Station : Connected station [ 1 ]
Address : Memory Address [ 000001 ]
Action : Alternate
④
GP – S070 4. Drawing
4-6. Manual monitoring
Touch key 1
⑤
⑤ Place the Touch key tag
* Display trigger?
Display trigger = Key
PLC
TIP
GP – S070 4. Drawing
4-6. Manual monitoring
①
Touch key 2
① [Draw]-[Touch key] or
select in tool bar.
②
② Set the Basic tab
Display trigger : Bit
Channel : Connected device [ INTERNAL ]
Address : Memory Address [ MC ]
GP – S070 4. Drawing
4-6. Manual monitoring
Touch key 2
③
③ Set ON, OFF shape in Form tab and
make the text
④ In Action tab,
Channel : Connected device [ INTERNAL ]
Address : Memory Address [ MA ]
Action : Momentary
♣ M0A M0C
Action Display trigger
④
GP – S070 4. Drawing
4-6. Manual monitoring
Touch key 2
⑤
⑤ Place the Touch key tag
Option/Trigger
- Normal : Trigger function is not used.
- ON : Acted when designated device is ON.
- OFF : Acted when designated device is OFF.
- Auto repetition : Acted repeatedly when pressing
touch key
②
①
④
③
①
Numeral Input 1
① [Draw]-[Numeral Input] or
select in tool bar
②
② Set the color
Color
Basic color(B) :
GP – S070 4. Drawing
4-7. Setting Input
Numeral Input 1
⑤
GP – S070 4. Drawing
4-7. Setting Input
ASC II Input
①
① [Draw]-[ASC II Input] or
select in tool bar
Color
Basic color(B) :
GP – S070 4. Drawing
4-7. Setting Input
ASC II Input
⑤
GP – S070 4. Drawing
4-7. Setting Input
Numeral Input 2 ①
① [Draw]-[Numeral Input] or
select in tool bar
②
② Set the Color
Color
Basic color(B) :
GP – S070 4. Drawing
4-7. Setting Input
Numeral Input2
EX1)
* Word Action of Touch Key Device : D100
Fixed : 1231
Indirect : No set
EX2)
Device : D100
Fixed : 1231
Indirect: D110
TIP
GP – S070 4. Drawing
4-7. Setting Input
①
Touch key(Word Action)
① [Draw]-[Touch key] or
select in tool bar
②
③ Word setting ③
Input device : [INT] D1004
Fixed value: 1
Indirect device : [INT] D1004
Initial condition value :1001
Reset value : 1
GP – S070 4. Drawing
4-7. Setting Input
Link Device
Link Device
④ Link Device is the function to save the connected device value to designated device of GP/LP comparing to direct monitoring.
Connection Diagram)
TM4 LP
Adress Parameter Description Adress
Present measuring D0
31001(03E8) CH1 Present Value value
D1
Position of sensor
31002(03E9) CH1 Dot decimal point D2
Unit of sensor D3
31003(03EA) CH1 Unit
temperature
D4
︙
31006(003ED) CH1 Cooling_MV Cooling value
31007(03EE) D12
~ CH2 parameter – Same as above CH1
︙
31012(03F3)
31013(0007) D18
~ CH3 parameter – Same as above CH1
31018(03F9)
31019(03FA)
~ CH4 parameter – Same as above CH1
31024(03FF)
GP – S070 4. Drawing
4-8. Alarm Checking
Alarm List ①
① [Draw]-[Alarm List] or
select in tool bar
②
② Set the shape and font
GP – S070 4. Drawing
4-8. Alarm Checking
Alarm List
③
Alarm List ⑤
⑤ Place the Alarm List tag
GP – S070 4. Drawing
4-9. Alarm History
Alarm History
① [Draw]-[Alarm History] or
select in tool bar ② Color
Basic color(B) :
Alarm History
③
③ Basic setting
Mode : History
Number of alarm : 6
Monitor Period : 20 (x100ms)
① [Draw]-[Touch key] or
select in tool bar
Practice