You are on page 1of 98

Technical training for Graphic Panel

GP-S070 Introduction

GP Series Competitors comparison & Application

AGENDA Data transmission

Drawing

Data logger
GP – S070
Introduction
GP – S070 1. GP-S070 Introduction
1-1. What is GP?

GP(Graphic Panel) is graphic interface devices to monitor parameters of controller as


Concept
PLC.
It is a kind of HMI(Human-Machine Interface) or MMI(Man-Machine Interface) devices.
GP – S070 1. GP-S070 Introduction
1-2. Major Features

Features Indicates up to 1590 texts per pages


Saves up to 500 pages(screen)
Easy S/W upgrade at website
(1) GP firmware file
(2) GP Editor (Drawing program)
(3) Additional protocol
Monitors the controllers of other devices
Supports various font s: Support several bitmap fonts (Selectable)
Supports various communication ports
 RS232C / RS422 multi communication port and USB HOST DEVICE, Ethernet etc.
Device monitoring function
 Monitors the parameters of the controllers connected to the GP and the devices without additional
datas.
Small size
 Space-saving with thin thickness
GP – S070 1. GP-S070 Introduction
1-3. GP-S070

7 " Wide display,
16,777,216 colors, True Color .
GP – S070 1. GP-S070 Introduction
1-3. GP-S070 Features

Features

Dot matrix touch method


-> free analog touch method
GP – S070 1. GP-S070 Introduction
1-3. GP-S070 Features

Features

GP-S070

200
3
4
1

Saves as file through data logger function


GP – S070 1. GP-S070 Introduction
1-3. GP-S070 Features

Features

Provide various graphic design of 593 basic library


GP – S070 1. GP-S070 Introduction
1-3. GP-S070 Features

Features

Bitmap fonts -> Supports vector fonts additionally


GP – S070 1. GP-S070 Introduction
1-3. GP-S070 Features

Ethernet USB HOST

USB

High speed download with supports of Ethernet, USB Host/Device


Enhances ease with firmware update via USB
GP – S070 1. GP-S070 Introduction
1-3. GP-S070 Features

Easy firmware upgrade via USB


Download drawing via USB
GP – S070 1. GP-S070 Introduction
1-4 Ordering information

GP S 070 T 9 D 6
① ② ③ ④ ⑤ ⑥ ⑦

ITEM DESCRIPTION
① ITEM GP Graphic panel
② SERIES S S series
③ SCREEN SIZE 070 7 inch
④ DISPLAY UNIT T TFT Color LCD
⑤ COLOR 9 16,277,216 colors
⑥ POWER SUPPLY D 24VDC
6 RS232C, RS422, USB Device, USB Host, Ethernet
⑦ INTERFACE
7 RS232C, RS232, USB Device, USB Host, Ethernet
GP – S070 1. GP-S070 Introduction
1-5 Part description

7inch LCD Power terminal


DC24V
A port B port Ethernet Mini USB
USB HOST
GP – S070 1. GP-S070 Introduction
1-6 Communication Interface (GP-S070-T9D6)

D-Sub 9pin female (RS422)


N0 SIGNAL No SIGNAL
1 TXD+   6 TXD-  

2 RXD+ 7 RXD- ②

3 RTS- 8 RTS+ ④

4 CTS+ 9 CTS-
5 SG     ⑥


D-Sub 9pin male (RS232)


N0 SIGNAL No SIGNAL
1 -  6 DSR

2 RXD 7 -  ④③
3 TXD 8 -  ②①
4 DTR 9 - 
5 SG    
⑨⑧
⑦⑥
GP – S070 1. GP-S070 Introduction
1-7 USB Interface

USB HOST PIN


1 5V
2 D-
3 D+
4 GND
- -
Able to update firmware by USB memory stick
and install GP/LP project file.

USB HOST PIN


1 5V
2 D-
3 D+
4 -
5 GND
Able to download the designed data of GP
EDITOR and upload log data.
GP – S070 2. Competitors comparison
2-3 GP-S044

M Corp. L Corp. O Corp.

GT1030-LBD(W) XP108 KA (B) NV3W–MG(R) 20L


MODEL GP S044
4.5 Inch 4.1 Inch 3.1 Inch
SCREEN SIZE 4.4 Inch
STN Mono STN Mono STN Mono
TYPE STN Mono
DRAWING 1.5 MB 256 KB -
MEMORY 512 KB
RS232 / RS 422 RS232 / RS 422 RS232
COMMUNICATION RS 232 /RS 422
GP – S070 2. Competitors comparison
2-3 GP-S057

P Corp. M Corp. L Corp.

GP2301-LG41-24V XTOP05MQ-ED-E XP30-BTA


MODEL GP S057
5.7 Inch 5.7 Inch 5.7 Inch
SCREEN SIZE 5.7 Inch
STN Mono STN Mono STN Mono
TYPE STN Mono
DRAWING 1 MB 6 MB 10 MB
MEMORY 512 KB
RS232 / RS 422 RS232 / RS 422
RS232 / RS 422 / CF
COMMUNICATION RS 232 /RS 422 USB / CF / Ethernet USB / CF / Ethernet
GP – S070 2. Competitors comparison
2-3 GP-S070

P Corp. M Corp. L Corp.

MODEL GP S070 AT3400-T1-D24 XTOP07TW-UD XP50-TTA

SCREEN SIZE 7 Inch 7.5 Inch 7 Inch 8.4 Inch

TYPE TFT Color TFT Color TFT Color TFT Color

DRAWING
MEMORY 16MB 16 MB 26 MB 10 MB

COMMUNICATION
RS 232 /RS 422 RS232 / RS 422
RS232 / RS 422
RS232 / RS 422
USB/Ethernet USB / CF / Ethernet USB / CF / Ethernet
GP – S070 2. Competitors comparison
2-4 Application

Cutting automation manufacturer


“D” company
CUTTING JIG
GP – S070 2. Competitors comparison
2-4 Application

Korea Research Institute


of Standards and Science
Turbo freezer vane control
GP – S070 2. Competitors comparison
2-4 Application

D Company
Automation packing machine
GP – S070 2. Competitors comparison
2-4 Application

Automation machine manufacturer


“R” company

Production equipment for snack


GP – S070 3. Data transmission
3-1 System composition

■ Transmit the completed data to GP by using GP EDITOR at PC.

1 WHITE-RED TXD+

2 RED TXD-

3 WHITE-GREEN RXD+

4 BLUE SG

5 WHITE-BLUE SG

6 GREEN RXD-

7 WHITE-BROWN SG

8 BROWN SG

Ethernet Communication Cable

PC GP

HUB: DIRECT cable compatible


PC : CROSS cable compatible
GP – S070 3. Data transmission
3-2 PC Setting

 Check IP address in order to use Ethernet interface

 Control panel → Network adapters → Local area protocol


properties(General) → Internet protocol properties(TCP/IP)
→ Check IP address by clicking general tab
GP – S070 3. Data transmission
3-3 GP Setting

GP-S070

BACK SYSTEM SETTING END

USER SCREEN IS NOT FOUND

Environme Functionali Diagnostic


Monitoring Data
nt ty s

Access the system setting menu


by touching the left-upper part of GP screen
GP – S070 3. Data transmission
3-3 GP Setting

GP-S070

이전 시스템설정
BACK SYSTEM SETTING / ENVIRONMENT END
종료

Serial Communication Language

모니터링Local Ethernet
환경설정 데이터 Screen Bright 진단기능
기능설정

Additional setting Time

Touch Environment Setting


GP – S070 3. Data transmission
3-3 GP Setting

GP-S070

이전
BACK시스템설정
SYSTEM \
SETTING
환경설정 / ENVIRONMENT / LOCAL ETHERNET 종료
END

시리얼설정 언어설정

IP Address 210.124.100. 200

Subnet Mask 255.255.255. 0


로컬이더넷설정 화면밝기
Gateway 210.124.100.250

Mac Address XX – XX - XX – XX - XX – XX

보조설정 시간설정

Touch Local Ethernet Setting


GP – S070 3. Data transmission
3-3 GP Setting

GP-S070

BACK SYSTEM SETTING / ENVIRONMENT / LOCAL ETHERNET END

IP Address 210.124.100. 200

Subnet Mask 255.255.255. 0

Gateway 210.124.100.250

Mac Address XX – XX - XX – XX - XX – XX

 IP Address : Do not set equally as the end of number of PC IP


 Subnet Mask : Same as PC
 Gateway : Same as PC
GP – S070 3. Data transmission
3-4 GP-Editor Setting

『 GP-Editor 』 [Menu] → [Communication] → [Download] → [Setting]


 Select Ethernet, then set target IP (Same as PC IP)
 Set communication, then click download
GP – S070 3. Data transmission
3-5 Download Display

GP-S070

※Do not cut power off during up/download


GP – S070 4. Drawing
- Preparation for drawing

No. MATERIALS DESCRIPTION PICTURES

1 Program GP-Editor 3.04(build 023)

2 LP-S070 Training Kit

Demokits

3 TM4-N2RB

4 Ethernet cable

Cable

5 RS422-RS485 cable
GP – S070 4. Drawing
- Preparation for drawing

4-2. Main screen 4-3. Overlap screen

4-4. Act Condition screen 4-5. Monitoring screen 4-6. Manual monitoring screen

4-7. Setting input screen 4-8. Alarm checking screen 4-9. Alarm History screen
GP – S070 4. Drawing
4-1. Generate Project

① [Project]-[Open] or ①
Click “GP training materials.prj”

② Set GP/LP type ②



③ Select the protocol in CH1 serial port
Use temp.controller TM4 and RS485 communication

④ Additional setting of project

♣ Device using for practice is LP Series, which has ④


HMI and PLC function simultaneously.
So, it use inner PLC without communicating
with additional PLC.
GP – S070 4. Drawing
4-1. Generate Project

⑤ Serial port setting


Same as the communication setting of TM4

⑥ CH1 communication port setting


Port : RS422
Station : 0


GP – S070 4. Drawing
4-6. Manual Operating Screen

* TM4 communication setting


* GP communication setting

Switch for setting communication station

PROTOCOL PORT

CH1 TM4_Mod_A RS422 Setting

CH2 EDITOR RS-232C Setting

GP station : 0
Flickers when power on at first
Indicator Communicati
LED on speed
CH1
CH1 LED 2400bps
9600/19200/38400
BAUD RATE 38400 CH2 LED 4800bps
Selectable
DATA LENGTH 8 CH3 LED 9600bps

PARITY NONE CH4 LED 19200bps


LED 38400bps
STOP 1

FLOW CONTROL XON/XOFF

TIP
GP – S070 4. Drawing
4-2. Main Screen

Screen on practice Completed screen

① Drawing : Draw line, circle, rectangle, text


② Converting screen : Converts screen by using touch key
GP – S070 4. Drawing
4-2. Main Screen


Drawing

① [Draw]-[Rectangle] or ②
select in tool bar

② Drag and place rectangle

③ Select line style and color

④ ‘Select inner color after selecting ‘Pattern 8’


Foreground Color : Color of pattern

Background Color : Color except pattern


GP – S070 4. Drawing
4-2. Main Screen

Text

① [Draw]-[Text] or
Select in tool bar ②

② Write text ‘MAIN’

③ Select text color and font ③


Bitmap font : Line is made with many dots
Vector font : Line is made with location and direction

④ Set the text location


GP – S070 4. Drawing
4-2. Main Screen

Screen Switching Key ①

① [Draw]-[Touch key] or
select in tool bar

② Input ‘3’ in Device/Screen Switching


in Action tab

③ Set the ‘operating status’ of Text(ON/OFF) ②


in Form tab


GP – S070 4. Drawing
4-2. Main Screen

④ Set the location of screen switching key


Practice
Draw the screen switching key of ‘6’ and ‘7’
right empty space.

Able to control size by dragging the red dots when


clicking objects

TIP
GP – S070 4. Drawing
4-3. Overlap


Screen on practice Completed screen

① Make the date and time tag and set current time
② Overlap screen setting
GP – S070 4. Drawing
4-3. Overlap

Date, Time

① [Draw]-[Clock] or
select in tool bar

② Select ‘Date’ in Basic tab

③ Set the Date Form and font in Form tab ②

④ Locate the Date



⑤ Draw ‘Time’ same as drawing Date

④ ⑤
GP – S070 4. Drawing
4-3. Overlap

Overlap setting ①
① Select ‘B-3’ in workspace

② [Draw]-[Overlap Screen] or select


Before overlap setting

③ Select ‘B-2’ for overlapping ②

④ Base screen applying ‘overlap screen’ ③


has green line at the edge.


『 Tip 』
- When selecting the background not ④ ⑤
objects, overlap screen will be selected.
- In[View]-[Overlap screen list], able to After overlap setting
edit or delete the overlap screen.
GP – S070 4. Drawing
4-4. Act Condition


① Monitors present value setting of temp.controller(TM4)


② Monitors the quantity in production line (PLC word data setting)
③ Monitors the power consumption via panel meter
④ Monitors the line speed via bar graph
GP – S070 4. Drawing
4-4. Act Condition

Numeral Display tag 1


① [Draw]-[Numeral Display] or
select in tool bar


② Select the shape and color in Basic tab
Frame : Color of line at the edge
in indicating screen

Plate : Background color in numeral
screen

③ Designate device
Channel : Connected device [CH1 TM4_Mod_A]
Station : Connected station [ 1 ] Color
Basic color(B) :
Address : Memory Address [ 301001 ]

TM4 communication
manual
GP – S070 4. Drawing
4-4. Act Condition

Numeral Display tag 1

④ Designate the digit as 5 and decimal point


as 1 in Form tab

* Decimal point is included in digit.
ex) Digit 3, Decimal Point 1 : 1.2
Digit 4, Decimal Point 2 : 1.23

⑤ Designate the font size as 2 X 2 ⑤

⑥ Place the numeral display tag


Make the numeral display tag for temp. 2.
Practice
TM4 Address : 301007

GP – S070 4. Drawing
4-4. Act Condition


Numeral Display tag 2

① [Draw]-[Numeral display] or
select in tool bar


② Select the shape and color in Basic tab
Frame : Color of line at the edge
in indicating screen
Plate : Background color in numeral ③
screen

Color
③ Designate device Basic color(B) :
Channel : Internal device [ INTERNAL ]
Address : Memory Address [ C130 ]

* Please make sure to select Channel


connected device and Station
connected station and address setting
when connecting with other PLC
GP – S070 4. Drawing
4-4. Act Condition

Numeral Display tag 2

④ Designate Digit as 4 in Form tab


⑤ Designate Font Size as 2 X 2

⑥ Place numeral display tag

Make the numeral display tab for defective


Practice items
PLC Device : C131

Input(Toggle Key)
X2 : Defective item’s qty +1
X0 : Passed item’s qty +1
X3 : Defective item reset
X1 : Passed item reset
GP – S070 4. Drawing
4-4. Act Condition

Panel meter

① [Draw]-[Panel meter] or
select in tool bar

② Designate device
Channel : Internal device[ INTERNAL ]
Address : Memory Address [ D1002 ] ②

③ Set Form tab


Type : Top 1/2
Maximum : 1000 ③
Minimum : 0
GP – S070 4. Drawing
4-4. Act Condition

Panel meter

④ Set the Scale display


⑤ Place panel meter tag


GP – S070 4. Drawing
4-4. Act Condition


Bar graph

① [Draw]-[Line/Trend/Bar] or
select in tool bar

② Select Bar graph in Basic tab

③ Set Form tab


Direction : Horizontal
Display scale : Bottom ③
GP – S070 4. Drawing
4-4. Act Condition

Bar graph

④ Designate device
Channel : Internal device [ INTERNAL ] ④
Address : Memory Address [ D1003 ]

⑤ Place bar graph tag


GP – S070 4. Drawing
4-5. Monitoring


Screen on practice Completed screen

① Monitor RUN/STOP status of temp.controller(TM4)


② Monitor the operating status of production line
③ Monitor the output status of temp.controller through part registration
④ Monitor the line status through Comment display
GP – S070 4. Drawing
4-5. Monitoring


Lamp 1

① [Draw]-[Lamp] or
select in tool bar

② Set the Basic tab



Designate device
Channel : Connected device [CH1 TM4_Mod_A]
Station : Connected station [ 1 ]
Address : Memory Address [ 000001 ]
Shape : Graphic Library

TM4 Communication
manual
GP – S070 4. Drawing
4-5. Monitoring

Lamp 1

③ Set ON, OFF shape in Bit tab ③

④ Make the text when ON, OFF


Position : Bottom(Outer)


GP – S070 4. Drawing
4-5. Monitoring

Lamp 1

⑤ Place lamp tag


GP – S070 4. Drawing
4-5. Monitoring


램프 2

① [Draw]-[Lamp] or
select in tool bar

② Set the Basic tab


Designate device
Channel : Connected device [INTERNAL]
Address : Memory Address [ Y0 ]
Shape : Graphic Library
GP – S070 4. Drawing
4-5. Monitoring

Lamp 2

③ Set ON, OFF shape in Bit tab ③

④ Place Lamp tag

Make the additional lamp in Heat line and


Practice Line for passed item.

Heater address : 000003
PLC Device : Y1
GP – S070 4. Drawing
4-5. Monitoring

Part : The function for applying it to part display, lamp, touch key tag after registering the object which user wants
Ex) When the image file part is registered

1.[Draw]-[Bit map] or 2. [Draw]-[Part] or

‘Part registration’ button will be act


when selecting the object

Add the image file


and place it on screen.

TIP
GP – S070 4. Drawing
4-5. Monitoring

Lamp 3

① [Draw]-[Lamp] or
select in tool bar


② Set the Basic tab
Designate device
Channel : Connected device [CH1 TM4_Mod_A]
Station : Connected station [ 1 ]
Address : Memory Address [ 100001 ]

Shape : Part

TM4 Communication
manual
GP – S070 4. Drawing
4-5. Monitoring

Lamp 3


③ Set ON, OFF shape in Bit tab

④ Place the Lamp tag

Make the monitoring lamp for output of


Practie heater 2.
Heater address : 100002


GP – S070 4. Drawing
4-5. Monitoring


Comment display

① [Draw]-[Comment Display] or
select in tool bar


② Set the Basic tab
Device : Word
Channel : Connected device [INTERNAL]
Address : Memory Address [ D2000 ]
Vector Font: 16 Size
GP – S070 4. Drawing
4-5. Monitoring

Comment Display

③ Set the start number and color in Word tab
Start Number : displayed gradually according to
the number of device

④ Make Comment List


1 : None
2 : All line
3 : Passed item line
4 : Defective item line

GP – S070 4. Drawing
4-5. Monitoring

Comment Display

⑤ Place the Comment display tag
GP – S070 4. Drawing
4-6. Manual monitoring

Screen on practice Completed screen

① Temp. controller(TM4) RUN / STOP operating key


② Operating key by line
GP – S070 4. Drawing
4-6. Manual monitoring


Touch key 1

① [Draw]-[Touch key] or
select in tool bar


② Set the Basic tab
Display Trigger: Bit
Channel : Connected device [CH1 TM4_Mod_A]
Station : Connected station [ 1 ]
Address : Memory Address [ 000001 ]
Shape : Graphic Library
GP – S070 4. Drawing
4-6. Manual monitoring

Touch key 1

③ Set ON, OFF shape in Form tab

④ In Action tab,
Channel : Connected device [CH1 TM4_Mod_A]
Station : Connected station [ 1 ]
Address : Memory Address [ 000001 ]
Action : Alternate


GP – S070 4. Drawing
4-6. Manual monitoring

Touch key 1

⑤ Place the Touch key tag

Make the touch key of Heat2.


Practice Heater address : 000003
GP – S070 4. Drawing
4-6. Manual monitoring

* Display trigger?
Display trigger = Key
PLC

The ON shape is displayed when it is touched.

Display trigger = Bit


PLC

Device = X010 Device = X011


X010 ON
X011 OFF
The status of trigger device is displayed regardless of touch operation.

TIP
GP – S070 4. Drawing
4-6. Manual monitoring


Touch key 2

① [Draw]-[Touch key] or
select in tool bar.

② Set the Basic tab
Display trigger : Bit
Channel : Connected device [ INTERNAL ]
Address : Memory Address [ MC ]
GP – S070 4. Drawing
4-6. Manual monitoring

Touch key 2

③ Set ON, OFF shape in Form tab and
make the text

④ In Action tab,
Channel : Connected device [ INTERNAL ]
Address : Memory Address [ MA ]
Action : Momentary

♣ M0A M0C
Action Display trigger


GP – S070 4. Drawing
4-6. Manual monitoring

Touch key 2

⑤ Place the Touch key tag

Make the touch key for first ‘All Stop’.


Practice Display trigger: Key
Action : Momentary [INT]Md

Practice Make 3 touch keys for second ‘Passed item line’.

- Auto operating - Operating - Stop


Display trigger : Bit [INT]M6 Display trigger : Bit [INT]Y0 Display trigger : Bit [INT]Y1
Action : Momentary [INT]M4 Action : Momentary [INT]M0 Action : Momentary[INT]M1
GP – S070 4. Drawing
4-6. Manual monitoring

Touch key 2-1

Option/Trigger
- Normal : Trigger function is not used.
- ON : Acted when designated device is ON.
- OFF : Acted when designated device is OFF.
- Auto repetition : Acted repeatedly when pressing
touch key

Trigger Type : OFF


Device : [INT] M6
GP – S070 4. Drawing
4-7. Setting Input



Screen on practice Completed screen

① Manipulate the setting value of temp. controller(TM4)


② Set the model name through text input
③ Manipulate the production quantity and speed by line
④ Manipulate the speed through touch key
GP – S070 4. Drawing
4-7. Setting Input


Numeral Input 1

① [Draw]-[Numeral Input] or
select in tool bar


② Set the color

③ Channel : Connected device [CH1 TM4_Mod_A]


Station : Connected station [ 1 ]

Address : Memory Address [ 400001 ]

Color
Basic color(B) :
GP – S070 4. Drawing
4-7. Setting Input

Numeral Input 1

④ Set the Digit as 5 and Decimal Point as 1


in Form tab.

⑤ Place the Numeral Input tag.

Make the Numeral Input tag of Temp. 2.


Practice Heater address : 401001


GP – S070 4. Drawing
4-7. Setting Input

ASC II Input

① [Draw]-[ASC II Input] or
select in tool bar

② Set the Color ②

③ Channel : Connected device [ INTERNAL ]


Address : Memory Address [ D1010 ]

Color
Basic color(B) :
GP – S070 4. Drawing
4-7. Setting Input

ASC II Input

④ Set the Digit as 8 and Vector Font as 20


in Form tab. ④

⑤ Place the ASC II Input tag


GP – S070 4. Drawing
4-7. Setting Input

Numeral Input 2 ①

① [Draw]-[Numeral Input] or
select in tool bar


② Set the Color

③ Channel : Connected device [ INTERNAL ]


Address : Memory Address [ D1000 ] ③

Color
Basic color(B) :
GP – S070 4. Drawing
4-7. Setting Input

Numeral Input2

④ Set the Digit as 4 in Form tab



⑤ Place the Numeral Input tag

Make 3 Numeral Input tags for below figures.


Practice 1. Passed item line sped : [INT]D1004
2. Defective line qty: [INT]D1001
3. Defective line speed: [INT]D1007 ⑤
GP – S070 4. Drawing

EX1)
* Word Action of Touch Key Device : D100
Fixed : 1231
Indirect : No set

D100 : 0 D100 : 1231

EX2)
Device : D100
Fixed : 1231
Indirect: D110

1) Save the fixed value to designated device


D100 : 0 D100 : 4444
D110 : 3213 D110 : 3213
2) Save the sum value of Indirect device value and
fixed value to designated device

TIP
GP – S070 4. Drawing
4-7. Setting Input


Touch key(Word Action)

① [Draw]-[Touch key] or
select in tool bar

② Set key, shape and form of Display trigger


GP – S070 4. Drawing
4-7. Setting Input

Touch key(Word Action)

③ Word setting ③
Input device : [INT] D1004
Fixed value: 1
Indirect device : [INT] D1004
Initial condition value :1001
Reset value : 1
GP – S070 4. Drawing
4-7. Setting Input

Touch key(Word Action)

④ Place the Touch key tag ④

Make 3 Touch key tags for below figures.


Practice 1. Decrease of passed item line speed : [INT]D1004
2. Increase of defective item line speed : [INT]D1007
3. Decrease of defective item line speed : [INT]D1007
GP – S070 4. Drawing
4-8. Alarm Checking

Screen on practice Completed screen

① Data transmission through Link device


② Make the Alarm list
GP – S070 4. Drawing
4-8. Alarm Checking

Link Device

① Select [Common setting]-[Link Device] ②

② Set CH1 internal Link Device


Channel : Connected device [ INTERNAL ]
Address : Memory Address [ D0 ]

③ Add the connected device ③


Channel : Connected device [CH1 TM4_Mod_A]
Station : Connected station [ 1 ]
Address : Memory Address [ 301001 ]
GP – S070 4. Drawing
4-8. Alarm Checking

Link Device

④ Link Device is the function to save the connected device value to designated device of GP/LP comparing to direct monitoring.

Connection Diagram)
TM4 LP
Adress Parameter Description Adress

Present measuring D0
31001(03E8) CH1 Present Value value
D1
Position of sensor
31002(03E9) CH1 Dot decimal point D2

Unit of sensor D3
31003(03EA) CH1 Unit
temperature
D4

31004(03EB) CH1 Set Value Present temp. D5


setting value
19
D6
31005(003EC) CH1 Heating_MV Heating value


31006(003ED) CH1 Cooling_MV Cooling value

31007(03EE) D12
~ CH2 parameter – Same as above CH1


31012(03F3)

31013(0007) D18
~ CH3 parameter – Same as above CH1
31018(03F9)

31019(03FA)
~ CH4 parameter – Same as above CH1
31024(03FF)
GP – S070 4. Drawing
4-8. Alarm Checking

Alarm List ①
① [Draw]-[Alarm List] or
select in tool bar


② Set the shape and font
GP – S070 4. Drawing
4-8. Alarm Checking

Alarm List

③ Set the Form


Number of device : 6
Device : [INT]M20
Comment number : 5
Number of display : Plural
Alignment : Ascending

④ Make the Comment List : No.5 ~ No.10



No.5 M20
No.6 M21 When heater is disconnected,
No.7 M22 alarm is ON.
No.8 M23
No.9 M24 X4 switch
No.10 M25 X5 switch
GP – S070 4. Drawing
4-8. Alarm Checking

Alarm List ⑤
⑤ Place the Alarm List tag
GP – S070 4. Drawing
4-9. Alarm History

Screen on practice Completed screen

① Make the Alarm History


② Touch key for managing the Alarm History (Erase all, Erase selected, Move cursor)
GP – S070 4. Drawing
4-9. Alarm History

Alarm History

① [Draw]-[Alarm History] or
select in tool bar ② Color
Basic color(B) :

② Set the shape


GP – S070 4. Drawing
4-9. Alarm History

Alarm History

③ Basic setting
Mode : History
Number of alarm : 6
Monitor Period : 20 (x100ms)

④ Set the Monitor device


No.5 M20 ④
No.6 M21 When heater is disconnected,
No.7 M22 alarm is ON
No.8 M23
No.9 M24 X4 switch
No.10 M25 X5 switch
GP – S070 4. Drawing
4-9. Alarm History

⑤ Place the Alarm History tag ⑤


GP – S070 4. Drawing
4-9. Alarm History

① [Draw]-[Touch key] or
select in tool bar

② Set the shape


Set the color of switch and frame
Make the text : ALL Del (Erase key for all alarm)
GP – S070 4. Drawing
4-9. Alarm History

③ Set the Touch Key Action


Key Code : Erase all alarms

Practice

Make 3 Touch key tags.

1. Erase selected alarm

2. Move cursor upward

3. Move cursor downward

You might also like