You are on page 1of 7

SANDVIK MOBILE CRUSHERS & SCREENS

TRANSFER CONVEYOR PRESSURE CRITICAL


RED FAULT
SAFETY FIRST

Sandvik’s objective is zero


harm to our people, the environment
we work in, our customers and
our suppliers.

PROTECTIVE
EMERGENCY
ALARM
NUMBER
EQUIPMENT

EMERGENCY ASSEMBLY
EXIT POINT

2
QUALITY FOCUS

ZERO DEFECTS TO CUSTOMER


Sandvik aims to be THE preferred and
recurrent supplier in Mobile Crushing and
Screening

3
FAULT CODE NUMBER 116: FAULT CODE DESCRIPTION.
THIS FAULT IS PRESENTED WHEN THE PRESSURE TRANSDUCER IS DAMAGE OR DISCONNECTED.

4
FAULT CODE NUMBER 116: POSSIBLE CAUSES.

NO POWER:

CHECK THE FUSE IS WORKING OK.

DAMAGED WIRING:

CHECK THE CONTINUITY OF THE WIRING, REPLACE AS REQUIRED.

DAMAGE SENSOR:

CHECK THE SENSOR FOR DAMAGE AND CHECK THE SIGNAL BACK INTO THE CONTROLLER.

CHECK THE TRANSFER CONVEYOR:

CHECK THE ROLLERS AND THE CONVEYOR NOT STACK.

5
FAULT CODE NUMBER 116: HYDRAULIC PRESSURE TEST
TEST THE TRANSDUCER VOLTAGE FUNCTION BETWEEN 0.5 TO 4.5 VOLTS