You are on page 1of 12

SANDVIK MOBILE CRUSHERS & SCREENS

CCS BELOW SAFE OPERATING POSITION


RED FAULT
SAFETY FIRST

Sandvik’s objective is zero


harm to our people, the environment
we work in, our customers and
our suppliers.

PROTECTIVE
EMERGENCY
ALARM
NUMBER
EQUIPMENT

EMERGENCY ASSEMBLY
EXIT POINT

2
QUALITY FOCUS

ZERO DEFECTS TO CUSTOMER


Sandvik aims to be THE preferred and
recurrent supplier in Mobile Crushing and
Screening

3
FAULT CODE NUMBER 105: RED FAULT PRESENTATION.

4
FAULT CODE NUMBER 105: FAULT CODE DESCRIPTION.
THIS FAUL IS PRESENTED WHEN THE ELECTRICAL SIGNAL OF THE POSITION SENSOR IS OPEN OR IN
SHORT CIRCUIT .

5
FAULT CODE NUMBER 105: POSSIBLE CAUSES.

NO POWER:
CHECK THE VOLTAGE 24 VOLTS ON THE “A” PIN FROM THE SENSOR LINE.

DAMAGED WIRING:

CHECK THE CONTINUITY OF THE WIRING, REPLACE AS REQUIRED.

DAMAGE SENSOR:

CHECK THE SENSOR FOR DAMAGE AND CHECK THE SIGNAL BACK INTO THE CONTROLLER.

6
FAULT CODE NUMBER 105: FAULT CODE POSITION SENSOR VALUE.

7
FAULT CODE NUMBER 105: DIMENSION REFERENCE VALUES.

8
FAULT CODE NUMBER 105: ELECTRICAL VALUES.

IF THE VALUES ON THE SCREEN IS DIFFERENT THAN THE ACTUAL “A” VALUE.

• OPERATE MANUALLY AND SEE IF THE VALUE ON THE SCREEN CHANGES IN RELATION THE ACTUAL
“A” VALUE ‘A’

• CHECK THE WIRING CONTINUITY.

• CHECK THE RESITENCE VALUE 470 OHMS.

• CHECK FUSE F18.

• TEST SIGNAL BACK TO THE CONTROLLER A102 PIN 48 miliAmps.

• REPLACE A SENSOR IF REQIRED.

9
FAULT CODE NUMBER 105: POSITION SENSOR FUNCTION.

10
FAULT CODE NUMBER 105: ELECTRICAL DRAWING.

11
WWW.SANDVIKMOBILES.COM