FAULT CODE NUMBER 105: RED FAULT PRESENTATION.
4
FAULT CODE NUMBER 105: FAULT CODE DESCRIPTION.
THIS FAUL IS PRESENTED WHEN THE ELECTRICAL SIGNAL OF THE POSITION SENSOR IS OPEN OR IN
SHORT CIRCUIT .
5
FAULT CODE NUMBER 105: POSSIBLE CAUSES.
NO POWER:
CHECK THE VOLTAGE 24 VOLTS ON THE “A” PIN FROM THE SENSOR LINE.
DAMAGED WIRING:
DAMAGE SENSOR:
CHECK THE SENSOR FOR DAMAGE AND CHECK THE SIGNAL BACK INTO THE CONTROLLER.
6
FAULT CODE NUMBER 105: FAULT CODE POSITION SENSOR VALUE.
7
FAULT CODE NUMBER 105: DIMENSION REFERENCE VALUES.
8
FAULT CODE NUMBER 105: ELECTRICAL VALUES.
IF THE VALUES ON THE SCREEN IS DIFFERENT THAN THE ACTUAL “A” VALUE.
• OPERATE MANUALLY AND SEE IF THE VALUE ON THE SCREEN CHANGES IN RELATION THE ACTUAL
“A” VALUE ‘A’
9
FAULT CODE NUMBER 105: POSITION SENSOR FUNCTION.
10
FAULT CODE NUMBER 105: ELECTRICAL DRAWING.