Professional Documents
Culture Documents
Air Cleaner
Single element
Canister type
Service Indicator
Split Core Radiator Systems
- JW and SCAC
Cooling System
Common for SB & Cont
41 °C Ambient at 200 m
Cooling System
• Standard features
– At 200 m, 41 °C ambient capability for G3412TA
and 45 °C ambient capability for G3412CLE
• Common for standby/cont.
– CAT coolant
– Low coolant level sensor
– Fan, belt, and outlet guards
– Coolant drain with valve
• Piped to edge of baseframe
Cooling System (optional features)
• Jacket Water Heater
– 6 kW (PGS 350, 375 LE, 450 and 450 LE)
– 3 kW (PGS 150, 200 and 240)
– Baseframe mounted
– Includes isolation valves & adjustable
thermostat
– AC disconnect included
Exhaust Systems (standard)
• All components shipped loose
• Muffler
– End in/end out
• Elbow kit
• Rain Cap
Fuel System
• Gas pressure regulator
• Low pressure fuel system
– 10.3 - 40.6 kPa (1.5 - 5.0 psi)
• Energize to Run (ETR) gas shutoff
valve (GSOV)
Governing System
• Flo-Tech speed control and ITB
(integrated throttle body and actuator)
– PGS 150, 200 and 240
• 2301 A speed control with Cat
EG3P actuator
– PGS 350 through 450 LE
GENERATORS
Class H insulation
12 lead
SE std with optional PM
"Premium" generators
Generators - Standard Features
• Self Excited
• Class H insulation with Class F
temperature rise
• Random Wound
• 12 Lead (except 600 Volts)
• VR6 AVR with Reactive Droop
Generators - Standard Features
• Extension Box
– Separated AC and DC Connections
– Random Wound
– Permanent Magnet (PM)
– Space heater
– Bearing & Winding temperature detectors
Gas PGS 150-450 LE Power Termination Area
• Standard features
– Power Terminal Strips
– Single point grounding
Customer Wiring
Cable Connections
Dedicated wiring box
Large terminal box
Single point for connections
Excellent cable access Streamlined for
Separated AC / DC
direct access
DIN rail terminal points
Circuit Breakers (Optional)
• UL compliant 3-pole
– 80% rated
– Rear and side mount
– Bottom cable entry
– 24 VDC Shunt trip
– Multiple breakers (two or three)
Circuit Breakers - Optional
• Auxiliary contacts
• Full size neutral bar
• Excellent cable bending/clearance
Control Panels
Gas PGS 150-450 LE
Control Panels
2 versions
EMCP II - Standard
• Microprocessor based
– Programmable
• Highly accurate
– True RMS sensing
• “Staged” shutdown
– GSOV closes first
– Ignition continues to combust remaining gas
– Gas and ignition are stopped immediately during Overspeed and Emergency
shutdowns
EMCP II+ - Optional
• 32 bit microprocessor
• Full power metering
• Built in protective relaying
• Expanded I/O
• Expanded communications / control
Lube System
• Oil drain with valve - standard
– Terminated on the edge of baseframe
• UL 2200 Packages
- Available approx. 6 months after 1st shipment