Principle:
Figure (e)
Confidential Document
No Power improper maintenance methods
Principle:
In this figure, DXP detection
of this signal is temperature
PIN, it is connected to a
thermistor. normal working
hours, PWR_PSON # and
the PSON # is conduction,
DXP detect the CPU
temperature exceeds its
limit, Fengyun IC to Will
PWR_PSON # and PSON #
to turn off the system power
off, so to protect the CPU
overheat and burn Buzhi Yu.
Figure (f)
Confidential Document
No Power improper maintenance methods
Specific maintenance steps:
Confidential Document
No Power improper maintenance methods
Check PSON # This line is OK. (Table amount of electricity from PSON # to the graphics card
protection circuit ATX)
Check protection circuit card issued PWR_PSON # whether action, if the action properly, check
the CPU over-temperature protection circuit is working properly.
Check AS-016 chips sent SUSB is normal, if OK, then check the graphics card protection circuit
is working correctly.
Southbridge issued SUSB # Check whether it is normal, and if OK, replace the AS-016 chip.
If SUSB # issued without the normal, check the supply Southbridge 32KHZ frequency,
PWRBTN # and RSMRST # these signals are normal. If you are OK, you can try to replace the
South Bridge.
If 32KHZ oscillator sluggish, you can replace the oscillator. If no normal distribution PWRBTN #
South Bridge, you can check the relevant circuit.
If the AS-016 does not normally issue RSMRST #, you can check the BATT supply AS-016 and
the 5VSB is OK, if correctly, you can replace the AS-016, or check the relevant line.
Confidential Document
No Power improper maintenance methods
1. Check PWR_PSON # This line is OK. (the amount of PWR_PSON # multimeter to the
graphics card protection circuit from ATX)
2. Check Southbridge issued SUSB # signal is normal, if the signal is normal, you can replace
the Super I / O.
3. If the southbridge is not issued SUSB #, then check the supply of South Bridge, 23KHZ,
RSMRST # and IO_PME # is normal, three signals are OK if you can replace the South
Bridge.
4. 32.768KHZ pulse, if not, then check the relevant line.
5. RSMRST # signal if not, then check the supply of Super I / O's 5VSB and BATT is normal,
are OK if you can replace the Super I / O.
6. If IO_PME # not working properly, then look in the press PWRBTN # button, PWRBTN #
pull and pull-down signal if the action, if you can replace the Super I / O.
Confidential Document
00 OR FF improper maintenance methods
For FF, 00 can not boot there are several different classification of the phenomenon will be described
below (the PC-DL models as an example):
Below:
Confidential Document
00 OR FF improper maintenance methods
1. to get this board first Check the motherboard's basic operating voltage, Vcore, 1.5V, 2.5V and
1.8V. If one does not check the voltage of power supply output is related to the circuit.
2. Check RSTCON # whether 3V, if not then check +3 VSB and RSTCON # diode value is
normal.
3. Check the motherboard of the fundamental frequency, supply Southbridge 14Mhz and
33Mhz.
4. Check southbridge supply the ICHPCIRST # AS-016 is normal, if normal to consider
replacing the AS-016.
5. If the southbridge is not output ICHPCIRST #, the South Bridge ICH_PWROK Check the
supply is correct, if OK, you can consider replacing the southbridge.
6. If ICH_PWROK problems, the supply of AS-016 Check the +5 V and the BATT voltage is
normal, if it is normal, replace the AS-016.
Confidential Document
00 OR FF improper maintenance methods
This phenomenon is mainly for the CPU does not read the BIOS information. BIOS, there are two
connections, one to go ISA bus, LPC bus, another walk. For the PC-DL this aircraft, it is connected to LPC.
1. Check BIOS on ICHPCIRST # is OK, normal, then a +3 V voltage, the signal after pressing
the RSTCON # high to low by the sub-high.
2. Check BIOS on PCICLK_FWH is OK, normal, then you can measure with an oscilloscope
to the 33Mhz frequency.
3. Check BIOS on FWH_IC is OK, this signal is used to set the BIOS is a model which, when
high that the choice of the A / A MUX Mode (ISA architecture), is low that the FWH mode is
selected (LPC Architecture), the board in this machine through a resistor in this signals Pull
Low.
4. Check BIOS is on the FWHHINIT # OK, this is a BIOS initialization signal, normal, then you
can measure with an oscilloscope to the +3 V voltage.
5. Check BIOS on LAD0 ~ LAD3 four signals are normal, with three tables and the
oscilloscope with its two extremes and the voltage is normal.
6. If these signals are OK, as the BIOS information on the general air burning, can replace
the BIOS.
Confidential Document
00 OR FF improper maintenance methods
This phenomenon is not inserted plug CPU CPU DEBUG and run on the data card is the same.
1. First Check Vcore voltage is normal, if not OK, then check the Vcore related lines.
2. Check CPU's CPUPWROK and CPU_RST # is normal, if CPUPWROK not, then check
whether the working conditions of South Bridge OK, if all OK, you can replace the South
Bridge. If not CPU_RST #, first check the supply voltage and frequency northbridge is
normal, then check the HUB-LINK between north and south bridge line is normal, if the
signal is OK, you can replace the North Bridge.
4. Check Host Bus's GTLREF is normal, the normal voltage of Vcore voltage two-thirds.
5. Check CPU's TESTHI signal is normal, if not correct for the CPU to the CPU will not work
there.
Confidential Document
00 OR FF improper maintenance methods
This is like the CPU has to move now, but in reading the address data file or data errors lead to the machine.
1. Check CPU of the HA [3:31] #, HD [0:63] #, HDSTBN [0:3] #, HDSTBP [0:3] # and HDBI
[0:3] # signals are those OK, mainly through the amount of Measured to determine the value
of two-body protection, for if there are Open or Short amount to the need to take the line to
determine Socket or North Bridge.
2. Check HUB_LINK between north and south bridge signal is normal. DEBUG lock step
when running, in the first time, DEBUG DATA and ADDRESS on the display is not correct,
such as: DATA: FFFFFFFF ADD: 00BFBFD0, then check these signals.
4. If these signals are OK, it may be caused by bad bridge, south bridge replacement be
replaced, to replace the North Bridge.