EZ Positioning with
SINAMICS S120
Agenda
Automation and Drives
Agenda
Agenda
Production Machines
Click on Hardware Icon and Open HW Configuration
Open Hardware Catalogue
Agenda
Insert S7 300 Rack, Power Supply, and CPU
Production Machines
Drag the drive on to the Profibus Network
• Choose Node Address 4
Agenda • Select Present Firmware Version (2.5)
• Choose Telegram Type None
EZ Speed with
SINAMICS S120
Basic Starter Online Commissioning
Automation and Drives
Agenda
EZ Speed with
SINAMICS S120
Basic Starter Offline Commissioning
Automation and Drives
Agenda
Production Machines
Select Speed Control with Encoder
UseFunction Modules when Needed**
Agenda **For the Servo Extended Setpoint Channel is needed
Production Machines
Select Speed Control with Encoder
UseFunction Modules when Needed**
Agenda **For the Servo Extended Setpoint Channel is needed
Motor Configuration
Production Machines
Motor Data Up-read in Auto Configuration (Drive-CLIQ) **
**If Motor is a Drive-CLIQ Motor
Agenda Non Drive-CLIQ Motors can be Selected from List
Third Party Motors can have data entered
Motor Configuration
For Third Party Motors Select Complete Motor ID
Production Machines
Motor ID will be Completed on First Start Command
Agenda
Motor may rotate back and forth slightly on Demo
Insure motor is braked for actual application if needed
Encoder Configuration
Choose Encoder Data for Non Drive – CLIQ Encoder
Production Machines
Siemens and Third Party Encoders can be Parameterized
Agenda
Choose 1024 HTL for the DEMO Induction Motor
Note Encoder 1 is from Motor Encoder
Technology Type
Production Machines
Choose Free Telegram with BICO
The Profibus Telegram will be Configured Later
Agenda Free Telegram allows Custom Telegrams
Script Files will be used to Setup Telegram Mapping
Production Machines
Review data and Click Finish if Complete
After Completing DDS Wizard “Save and Compile”
Agenda DDS Wizard Data is now Complete
Production Machines
From the Drive to be Commissioned Choose…
Configuration
Agenda
Production Machines
Telegram has Successfully been Transferred
Note Blue Check Boxes
Agenda
EZ Speed with
SINAMICS S120
Starter Script File
Automation and Drives
Agenda
EZ Speed with
SINAMICS S120
S7 Simatic Manager Programming
Automation and Drives
Production Machines
Open New Sinamics S7 Project
And Open Hardware Configuration
Agenda To Confirm Configuration of Telegram
Production Machines
Highlight the Profibus Card and View the Telegram
Telegram will be “User Defined”
Agenda
Length should be 6 words (12 bytes)
Production Machines
Save and Compile HW Configuration
Download Configuration to PLC
Agenda
Production Machines
Follow S7 Sequence to Download Hardware Config
Select Target Module (If Multiple PLCs)
Agenda
Restart PLC after Download
PLCs LED will still show Fault
Production Machines
Open the Example Program and Copy Relevant Blocks
Task Bar – Use Window / Arrange Horizontally
Agenda
Production Machines
Open the Example Program and Copy Relevant Blocks
See Example Below for Copying Blocks
Agenda
Production Machines
Right Click on S7 Blocks Folder and Insert a FC
Edit Symbolic Name and Comments
Agenda
Production Machines
DB number is Entered to Generate Instance DB
Enter DB115 in “????” to test with Variable table included
Agenda
Multiple FB115s with Specific DBs can be used
Production Machines
Nominal RPM and Hex address from Drive
Use Nominal Current, Volts, Torque, and RPM for Demo
Agenda
Address is same as in Hardware Config-Profibus for Drive
Address is Hex value and not decimal value
Save FC
Insert FC In OB1
Open OB1 Block
Production Machines
Save Program in OB1 After Inserting FC
Agenda
Production Machines
Open Symbol Table and Edit Instance DB
Name for DB can be symbolic to Axis
Save Symbol Table
Agenda
Production Machines
Open the Blocks Folder and Download the Blocks
Use the Download Button on the S7 Manager task bar
Agenda
EZ Speed with
SINAMICS S120
Testing Application
Automation and Drives
Jogging Setpoints
Click on Speed Setpoint Folder under Drive
Production Machines
• Use New Setpoints for Jog1 and Jog2
Agenda
Jogging Axis
Use Jog bits 0.5 and 0.6 to Jog Axis
Production Machines • Bit 0 must be OFF
• Bit 0.1 – Bit 0.3 Must be ON for Jogging
Agenda
<1>
<2>
<3>
Torque Control
Use the VAR Table to Run in Torque Control
Production Machines
Control Word 1 must be On
Use Bit 4.0 for Toque Control
Agenda
Use DBW 64 for Torque Setpoint
FB 110 Diagnostics
These Status Bits and Words can be used in PLC Logic
Production Machines
Agenda
Production Machines
Agenda