Professional Documents
Culture Documents
Storages Tanks
Conclusions
References
STORAGES TANK
. Reid Vapor
Tank
Pressure
The roof had a conic shape and fixed. They are generally used to store products with a
These tanks must be equipped with pressure relatively high vapor pressure, with a great
and vacuum valves. tendency to emit vapors at environment
temperature.
For medium and large volume tanks, the roof
must be supported on columns that make it
difficult to install a floating membrane
the floating roof above the surface of the It is used for light products, with the
product, eliminates space for gas purpose of eliminating the formation of
formation. Floating roofs are currently the gases that produce losses by evaporation.
most effective for ordinary service since
evaporation losses are reduced. However,
they have limited use since the gasket of
the ceiling has an operating pressure
limit.
Some characteristic:
• usually stainless steel or chrome and silver
• Its measurement scale must be in meters,
centimeters and millimeters.
• Ground pole to avoid sparking due to static.
Plumb
BACKGROUND MEASUREMENT
It consists of measuring the distance from
the measurement at the bottom of the tank
to the free height of the liquid, where the
mark on the measuring tape thus obtaining
the height of the liquid directly.
The bottom plumb line is used in this type of
measurement, the measurement is taken
from the bottom up, where zero is the tip of
the plumb bob.
Tomada de: Manual de medición de hidrocarburos capitulo 3 Tomada de: Manual de medición de hidrocarburos capitulo 3
medición estática (Ecopetrol) medición estática (Ecopetrol)
To detect the level of free water, the water stopping ointment should be applied
in equal layers without covering the graduation of the numbers on the scale.
The tape is lowered until the plumb bob hits the bottom and
left for a while until the mark is made.
• For the determination of Sediment, the ASTM D-473 standard should be used(Extraction Method).
AUTOMATIC MEASUREMENT
(TELEMETRY)
Elevated tanks.
underground tanks.
pressurized tanks.
Tomada de: Manual de medición de hidrocarburos capitulo 3
medición estática (Ecopetrol)
HYBRID MEASUREMENT (RADAR O
SERVO AND PRESSURE MEASURER)
The servo o radar is used to determine the level of the
liquids inside the tank and from the pressure indicator
transmitter deduces the density of the fluid contained
in the tank. 𝑉𝑜𝑙𝑢𝑚𝑒=𝑙𝑒𝑣𝑒𝑙
𝑃𝑟𝑒𝑠𝑠𝑢𝑟𝑒
𝐷𝑒𝑛𝑠𝑖𝑡𝑦 =
𝐿𝑒𝑣𝑒𝑙
𝑉𝑜𝑙𝑢𝑚𝑒
𝑀𝑎𝑠𝑠= 𝐷𝑒𝑛𝑠𝑖𝑡𝑦 ∗
𝐿𝑒𝑣𝑒𝑙
VOLUMETRIC MASS
• Directors • Coriolis
• Indirectors • Thermal
Positive Displacement
the casing is made to precision and contains
a rotor that rotates on ball bearings, and
includes blades evenly distributed. As the
liquid flows through the meter, the rotor and
the paddles rotate around a fixed axis,
causing them to move outward.
• Deaerators
separates and sends the vapors or gases
contained in the stream into the atmosphere,
preventing them from reaching the meter.
• Filters
Prevents solid elements from reaching the
meter.
Tomado de: Manual de medición de hidrocarburos capitulo 5
medición dinámica (Ecopetrol)
INDIRECT VOLUMETRIC METERS
Deduce the flow rate by measuring
some dynamic property. Pressure
Turbines
differential
Ultrasonic vortex
Vortex
Magnetic Rotameter
TURBINES
Determines the angular rotation of the rotor, translates them
into linear velocity and with this information is deduced from
the volume of liquid that has passed through the meter,
through of its cross-sectional area.
Q=V*A
Accuracy.
Wide flow range for low viscosity liquids. Support pressure is needed to avoid cavitation.
𝑃𝑏=2∗ 𝐷𝑃+1,25 ∗ 𝑃𝑣
±0,1 to 0,25
Linearity Pb=Minimum pressure in the meter
Cavitation
DP= Pressure drop in the meter
Pv= Vapor pressure
Repeatability
Deposits
± 0,02% to 0,05%
Rotor rotation
Bearing friction
ULTRASONIC METERS
𝑳= ( 𝑫 +𝟐 ∗ 𝑾 𝒕 ) + 𝟐∗ 𝑪𝒍 − 𝑭
𝑪𝑶𝑺 ∅
( 𝒅)
The flow that passes through specially designed tubes generates a force, equal but of
opposite sense in each half, making them vibrate, and whose magnitude is proportional
to the mass flow rate. This force and vibrations are detected by sensors and converted to
mass flow rate by means of a transmitter.
Fc = 2m x w
Fc = strength of coriolis
m =mass flow
w =angular velocity of pipe