You are on page 1of 12

SEMINAR TOPIC

DESIGN OF COMMERCIAL STEEL STRUCTURE BY


USING HOT ROLLED & PEB SECTION

SUBMITTED BY-: DEPARTMENT OF CIVIL ENGINEERING SUBMITTED TO-:


SYED MOHAMMAD ALI
20PGCES17
LINGAYA’S VIDYAPEETH, FARIDABD MR. RAMEEZUT TAUHEED
ASSISTANT PROFESSOR
MASTER OF TECHNOLOGY SESSION -(2020-2022)
IN CIVIL STRUCTURE ENGINEERING
INTRODUCTION

• The steel building having, Ground + Three floors. All


floor is comprised of Shops & Toilet. Terrace is open.
• The structure is proposed to be designed as Steel moment
resisting frame with steel columns, steel beams and floor
with deck slab as per seismic requirement. The building is
proposed in region with seismic zone-IV, hence relevant
provisions provided in code is duly followed.

STRUCTURE 3D
STRUCTURAL ARRANGEMENT

• Building Length -15m, Width- 15m & Height- 16m above


ground level
• Building Floor to floor height has been Identified as 4.0M
typical.
• The column is located at distance of 5m along length &
breadth. Beam is connected to all columns at all floor
levels. Secondary beam for supporting deck slab is at
1.25m c/c distance at every bay panel.
• All Structural steel sections shall conform to IS:2026. The
structural sections to be used shall be of yield stress 250
MPa.

ISOMETRIC VIEW
METHODOLOGY

• The analysis and design of existing and proposed


structure is carried out using STAAD pro v8i. Computer
program providing IS 800-2007 for design in the input. .
• Design of the building will confirm to IS 800-2007 with
Seismic forces as per IS-1893 (part-1): 2016 & (part-4).
Structural constructional arrangement comprises of
moment resisting frame, beam, columns, and slab.
• For seismic analysis, joints load (1.0 Dead load +0.25
Live load) is applied at floor level. Seismic zone
coefficient taken as per IS-1893:2016 as zone -4,
Importance factor-1.5 with damping factor as 5%.
• For the combination of forces under seismic force, live
load and dead load is taken as per the IS codes.
DESIGN LOADS

EARTHQUAKE IN X-DIRECTION EARTHQUAKE IN Z-DIRECTION


DEAD LOAD LIVE LOAD
Slab load @150mm thick =0.150x25=3.75kn/m2 Live load = 3.0kN/m2
Floor finish@50mm thick = 20x.05=1.0kn/m2
Partition wall load is taken as 1.0kn/m2
Total load = 3.75+1.0+1.0=4.925=5.75kN/m2
DESIGN AS PER HOT ROLLED SECTION

COLUMN SIZE OUTER


CORNER COLUMN
COLUMN

• CORNER COLUMN- ISMC 150 BOX


• OUTER COLUMN- ISMC 225 BOX
• MIDDLE COLUMN- ISMC 150 BOX

MIDDLE
COLUMN

COLUMN VIEW
BEAM SIZE OUTER MAIN
SECOUNDARY BEAM
BEAM

• OUTER MAIN BEAM- ISMB 300


• INTERIOR MAIN BEAM- ISMB 400
• SECOUNDARY BEAM- ISMB 250

INTERIOR
MAIN BEAM
BEAM PLAN VIEW
DESIGN AS PER PEB SECTION

COLUMN SIZE (I-SECTION) OUTER


COLUMN
CORNER
COLUMN

• CORNER COLUMN
WEB-250X4MM & FLANGE- 250X6
• OUTER COLUMN
WEB-350X5MM & FLANGE- 350X6
• MIDDLE COLUMN
• WEB-400X5MM & FLANGE- 400X10

MIDDLE
COLUMN

COLUMN VIEW
OUTER MAIN
BEAM SIZE (I-SECTION) SECOUNDARY
BEAM
BEAM

• OUTER MAIN BEAM


WEB-300X5MM & FLANGE- 150X8
• INTERIOR MAIN BEAM
WEB-400X6MM & FLANGE- 200X10
• SECOUNDARY BEAM
WEB-250X5MM & FLANGE- 180X8

INTERIOR
MAIN BEAM
BEAM PLAN VIEW
COMPARISON OF HOT ROLLED & PEB SECTION WEIGHT
TYPE OF SYSTEM HOT ROLLED PEB SECTION DIFFERENCE REMARKS
SECTION WEIGHT (KG) IN WEIGHT
WEIGHT (KG) (KG)

CORNER COLUMN 2100 2000 100 PEB IS EFFICIENT

OUTER COLUMN 6600 5800 800 PEB IS EFFICIENT

MIDDLE COLUMN 4600 4900 -300 PEB IS NOT EFFICIENT

OUTER MAIN BEAM 10900 7100 3800 PEB IS EFFICIENT

INTERIOR MAIN BEAM 14500 11600 2900 PEB IS EFFICIENT

SECOUNDARY BEAM 19800 16900 2900 PEB IS EFFICIENT

TOTAL WEIGHT 58500 48300 10200 10.2 TON STEEL SAVED

PEB SECTION WEIGHT IS 17.5% LESS THAN OF CONVENTIONAL HOT ROLLED


SECTION WEIGHT.