You are on page 1of 7

CONDENSER CONNECTION, COLTC, SEAL

STEAM

Amol Khankhoje
DMV-36
TO VAC. PUMP A,B & C
DM MAKE UP
CDV 39

VENT FROM HPH-6A/6B


CEP RECIRCULATION

CEP
SPRAY FROM
DM MAKE UP CDV 41 EMERGENCY MAKE UP
5 5
4 4
EMERGENCY MAKE UP
SPRAY FROM LPH-1A 1A
CEP
CEP DISH 1B LPH-1B
FROM DC VENT

W
3 3 DRIP FROM LP

W
GSC DRAIN FLASH TDBFP-B
TANK A FLASH DRIP FR
FROM LPH-3 TURBINE FLASH 6A
BOX TANK B
DRIP FR
TDBFP-A DRAINS (MAL DRAINS)
6B
DRIP FROM HPH PRDS D
5B 2 2 FROM H
5A/5B
VENT FROM HPH

FROM EXT. MANIFOL


CONDENSER A CONDENSER B FROM DC
LINE DRAINS
FROM LP
HOTWELL MANIFOL

1A TDBFP A EXHA
STEAM
1B TDBFP B EXHA
STEAM
2 CW INLET
3 CW OUTLET
4 VACUUM BREA
5 LPBP STEAM IN
CDV - 4 CEP-A CDV -5 CEP-B CDV – 6 CEP-C

CONDENSATE WATER
CONDENSER CONNECTIONS
From HPH-5A Vent
From HPH-5B Vent
FLASH TANK A

2 5
V-
DR
r ain
cy D
rgen
Eme LPH 3
from
FLASH TANK A

- 31
DRV

Drain to Hot well


Vent to
Condenser
CRHV 141 in
Dra n Coole
r
Steam to BFPT-A u/s Dra
i
of Strainer Line Drain 8
V1
DR
Steam to BFPT-A u/s of V-
42 ai n
Dr ain
Control Valve Line CRHV 135 DR 5 A cy
H- eAn y D
r
Drainto D/A Pegging
CRH HP eHrg-5 enc

From CEP Vents


BFPT-A Drain Manifold
EHmP erg
u/s of Control Em
Station Line Drain CRHV a in
159 Dr
Steam to BFPT-B u/s C
GS
of Control Valve Line CRHV
147
Drain
Steam to BFPT-B u/s
of Strainer Line DrainCRHV 153
Extn. To BFPT A&B
Line Drain EXV 109
Extn. to D/A Line Drain
EXV 170
FLASH TANK - B Vent to Condenser Spray Line from CEP Discharge
CDV 69

HRH Strainer L HPH 6A Vent


Drain

HP Drain Manifold
HRHV 106
HRH Strainer R HPH 6B Vent
Drain HRHV 105
CRH Line Drain
EXV 119
CRHV 101
EXT. to HPH 6A Line Drain EXT. to LPH-3

LP Drain Manifold
Drain
EXV 101 EXV 118
EXT. to HPH 6B Line Drain
EXV 102 FLASH TANK
LPBP Warm-up Line 1
Drain
-B
HRHV 113
LPBP Warm-up Line 1
Drain Turbine Gland Se
HRHV 114
Line Drain
LPBP Line 1 Drain ASV 155

LPBP Line 2 Drain

DRV 11

DRV 05
DRV 37
Drain to Hotwell
Drain Cooler Drain
UNIT FLASH TANK
Vent

HPBP-1 Warmup Line Drain CDV - 78


BPV - 104 BPV - 101

HPBP-2 Warmup Line Drain


BPV - 102 Spray Water
BPV - 103
From Plant

MS Line Drain
UNIT FLASH water system

TANK
MS Strainer L Drain
MSV - 105
MSV - 107

MS Strainer R Drain
MSV - 108 MSV - 106

Deaerator Drain and


Vent

To Drain Trench
HPCV-2 IPCV-2

HPT IPT LPT 1 LPT 2

SEAL STEAM HEADER

EXTRACTION
CRH

EXTRACTION
EXTRACTION
IPCV-1

EXTRACTION

EXTRACTION

EXTRACTION
HPCV-1

A2

A3
A4.2
A3.2
A5

A3
MAL-58

MAL-65 MAL-22 MAL-12 MAL-11 MAL-81 MAL- MAL-31MAL-27MAL-32MAL-47MAL-51 MAL-52MAL-54MAL-55 MAL-57


26

FLASHTANK-

PIPE-A
PIPE-B

FLASH
FLASH
A/B
MAIN TURBINE DRAIN
SCHEME
GSC

HPT IPT LPT A LPT B

CRH
MAW 10 MAW 50

ASV 69

ASV 67

TO CONDENSER
APRDS
FT - B GLAND STEAM SYSTEM
ASV 152

You might also like