M P
M P
Diesel G
T1
440 220V
T2
V
Diesel G
Distribution board
M P
PRIME MOVERS
The generators may be driven by a
diesel engine, by a steam or gas turbine,
or by the main propulsion engine as a
shaft generator.
The type of prime mover is determined by
the design of the ship and by economic
factors
electrical load.
The combined power rating of the
on board.
cargo ship
A cargo ship may have two main generators
typically rated from 350 to 1000 kW which
are sufficient to supply the engine room
auxiliaries while at sea and the winches or
cranes for handling cargo while in port.
emergency generator
Separation:
• The emergency system shall not be
affected by fire, flood and other casualty
in the main system.
• This means separation from the main
system when it comes to location and
functionality
Self contained
All required components and systems
needed for operation shall be located
inside the emergency generator room.
Start system:
• Emergency generator shall automatically
started and connected to the emergency
switchboard after black-out. (Within 45
seconds.)
• Two source of stored energy for starting
(No requirement for redundancy of start
motor.)
• Charging of start energy shall be from the
emergency switchboard
Location:
Location:
• Above upper most continuous deck.
• Accessible from open deck
• Not contiguous with other machinery
spaces
Location of E/G
power demand
single-phase a.c.