You are on page 1of 16

The CAE

1 www.andritz.com, 12.12.2011
Configuration of the CAE

The look and feel is that of the Windows-explorer

CAE Client Tree view:



Herein the structure of the available
parameters (folder) is displayed.

Windows Explorer

 List view:
All elements (files) belonging to one certain
type of parameter (folder) are displayed here.

2 www.andritz.com, 12.12.2011
Consistency Check and Loading

Start Loading

Option “Start Loading”: SCADA server will be loaded


Option “Update local project folder”: The local
pictures will be updated

3 www.andritz.com, 12.12.2011
Categories

 Process variables can be assigned to


categories (parameter fields Kat1-Kat10)

 The are used as filter criteria

4 www.andritz.com, 12.12.2011
PV-Groups

 Usage of PV-groups
- with picture displays
- with curve displays

5 www.andritz.com, 12.12.2011
Filters: Filter dialogue

 Easy, but limited filtering for:


- Text address
- Category
- Priority
- PV type
- State
- Status-bits

6 www.andritz.com, 12.12.2011
Lesson: Parameterize a Filter Dialogue

 Task
 Parameterize a filter dialogue in such a way, that the sequence of events list (CEL)
logs :
 only signals of your power plant

 only binary signals

 only datapoints with state ON

 Use this filter in the picture Training\Plant within an new button-element

7 www.andritz.com, 12.12.2011
Filters: Filter texts

 Own filter syntax

 For complex unlimited filtering possibilities

8 www.andritz.com, 12.12.2011
Lesson: Parameterize a Filter Dialogue

 Task
 Parameterize a filter text in such a way, that the sequence of events list (CEL) logs:

only signals of your power plant


 only binary signals

 only datapoints with state ON

 Use this filter in the picture Training\Plant within an new button-element

9 www.andritz.com, 12.12.2011
User Management: Users

 Every new user has to be assigned to a user group

 Every user has an individual password

 Exception "Default User" - no password

10 www.andritz.com, 12.12.2011
User Management: User groups

 Certain rights can be assigned to a user group

11 www.andritz.com, 12.12.2011
Lesson: Automatic login with guest user

 The SCADA-Client need to be logged in as a guest user after starting the


application

12 www.andritz.com, 12.12.2011
Aufgabe: „guest“ as default user

 Change the default user to the guest user


 Restart SCADA-Client and CAE-Client

13 www.andritz.com, 12.12.2011
Lesson: Create a new user and a new user group

 Create the following user and user group


 User: Training
 User group: TrainingGrp
 Only setpoints shall be possible (NO commands)

 Check the functionality within SCADA-Client

14 www.andritz.com, 12.12.2011
Lesson: Create a new user and a new user group

 Enhance the user Training


 Only setpoints for the “flow” shall be possible
 Define a corresponding filter dialogue

15 www.andritz.com, 12.12.2011
Lesson: Automatic to a default user after timeout

 Change the settings within the CAE in such a way that all SCADA-Clients
automatically login to a default user after 1 minute of user inactivity

 After successful testing of such functionality this setting can be deactivated

16 www.andritz.com, 12.12.2011