Professional Documents
Culture Documents
Product Datasheet
Bently Nevada* Asset Condition Monitoring
Description
The 3500/42M Proximitor*/Seismic Monitor is a four-channel
monitor that accepts input from proximity and seismic
transducers, conditions the signal to provide various vibrations
and position measurements, and compares the conditioned
signals with user-programmable alarms.
You can program each channel using the 3500 Rack
Configuration Software to perform the following functions:
n Radial vibration
n Thrust position
n Differential expansion
n Eccentricity
n REBAM
n Acceleration
n Velocity
n Shaft absolute
n Circular acceptance region
Page 1 of 20
Specifications Outputs
Inputs Front Panel LEDs
Indicates when the 3500/42M
Accepts from 1 to 4 proximity, velocity or OK LED Proximitor*/Seismic Monitor is operating
Signal
acceleration transducer signals properly.
Power consumption 7.7 watts, typical Indicates when the 3500/42M
Input Impedance Proximitor*/Seismic Monitor is
TX/RX LED
communicating with other modules in the
10 kΩ 3500 rack.
Standard I/O
(Proximitor and acceleration inputs)
Indicates when the 3500/42M
Bypass LED Proximitor*/Seismic Monitor is in Bypass
Sensitivity Mode.
3.94 mV/μm (100 mV/mil) or
Radial Vibration
7.87 mV/μm (200 mV/mil)
3.94 mV/μm (100 mV/mil) or
Thrust Buffered The front of each monitor has one coaxial
7.87 mV/μm (200 mV/mil)
Transducer connector for each channel.
3.94 mV/μm (100 mV/mil) or Outputs
Eccentricity Each connector is short-circuit protected.
7.87 mV/μm (200 mV/mil)
Differential 0.394 mV/μm (10 mV/mil) or Output
550 Ω
Expansion 0.787 mV/μm (20 mV/mil) Impedance
Page 2 of 20
Signal Conditioning Eccentricity
Specified at +25 ºC (+77 ºF) unless otherwise noted.
Within ±0.33% of full-scale typical
Accuracy
±1% maximum
Radial Vibration
Frequency Response
Page 3 of 20
Acceleration II Velocity and Velocity II
Within ± 0.33% of full scale typical Within ±0.33% of full-scale typical
Accuracy ± 1% maximum ±1% maximum
Exclusive of filters Accuracy +1% -3% with MTL 764(-) Zener External
Filter Quality Barrier
Exclusive of filters
4-pole
High-pass Full Scale 0-0.5: ±3% typical
(80 dB per decade, 24 dB per octave) Velomitor* sensor
Full Scale 0-1.0: ±2% typical
4-pole accuracy
Low-pass Full Scale 0-2.0: ±1% typical
(80 dB per decade, 24 dB per octave)
Velomitor sensor Under radiated immunity conditions, add
Frequency Response accuracy with ± 11% for all full scale ranges. The total
Bias filter -3 dB at 0.01 Hz barriers Velomitor sensor accuracy will be ± 15%.
Not OK filter -3 dB at 2400 Hz Frequency Response
1X and 2X vector Valid for machine speeds of 60 cpm to -3dB at 0.01 Hz
Bias
filter 100,000 cpm Velocity II only
-3 dB at 40 Hz
The following table represents the frequency Not OK filter
Velocity II only
ranges for the 3500/42M Proximitor*/Seismic RMS 10 to 5,500 Hz, -3 dB
Monitor under different options using the Peak or peak-to-
Acceleration II Channel Type: 3 to 5,500 Hz, -3 dB
peak
Valid for machine speeds of 60 to 100,000
Without Filter 1X and 2X vector
cpm
Output Type Low or High Pass With Integration filter
Velocity II only
Filter
Filter Quality
RMS 10 to 30,000 Hz 10 to 20,000 Hz
4-pole
Peak 3 to 30,000 Hz 10 to 20,000 Hz High-pass
(80 dB per decade, 24 dB per octave)
2-pole
Low-pass
(40 dB per decade, 12 dB per octave)
Page 4 of 20
Shaft Absolute, Velocity The following table summarizes the relationship
between nominal shaft speed and the valid speed
Within ±0.33% of full scale typical
Accuracy ±1% maximum
range:
Exclusive of filters
Nominal Shaft
Frequency Response Valid Speed Range (Hz)
Speed (Hz)
Peak or User-programmable 10 to <126 0.071 to 160
peak-to-peak 3 to 4,000 Hz, -3 dB
126 to <252 0.133 to 330
Filter Quality
252 to <504 0.25 to 660
2-pole
High-pass 504 to 584 0.50 to 750
(40 dB per decade, 12 dB per octave)
2-pole If a multi-event gear or speed wheel generates the
Low-pass
(40 dB per decade, 12 dB per octave) speed input, the upper limitation of the resultant input
Constant Q Filter signal is approximately 20 KHz.
1X vector filter Minimum rejection in stopband of -57.7
dB
Page 5 of 20
Accuracy Rack Space Requirements
Within ±0.33% of full scale typical
Monitor 1 full-height front slot
Amplitude ±1% maximum when input signal is at
the center frequency of the proportional I/O Modules 1 full-height rear slot
value's passband
Phase 3 degrees error, maximum
Barrier Parameters
You can use certain configurations to The following parameters apply to CSA-NRTL/C
enable only one channel of a channel
Channels enabled and ATEX/IECEx approvals.
pair.
Physical Alarms
Use Rack Configuration Software to set
Monitor Module (Main Board)
alert levels for each value measured by
Dimensions 241.3 mm x 24.4 mm x 241.8 mm the monitor and danger setpoints for any
(Height x Width x Depth) (9.50 in x 0.96 in x 9.52 in) two of the values measured by the
Weight 0.91 kg (2.0 lb) monitor.
I/O Modules (non-barrier) Alarm Setpoints Alarms are adjustable from 0 to 100% of
Dimensions 241.3 mm x 24.4 mm x 99.1 mm full-scale for each measured value.
(Height x Width x Depth) (9.50 in x 0.96 in x 3.90 in) However, when the full-scale range
exceeds the range of the transducer, the
Weight 0.20 kg (0.44 lb) range of the transducer will limit the
I/O Modules (barrier) setpoint.
Dimensions 241.3 mm x 24.4 mm x 163.1 mm Accuracy of alarm
Within 0.13% of the desired value
(Height x Width x Depth) (9.50 in x 0.96 in x 6.42 in) setpoints
Weight 0.46 kg (1.01 lb)
Page 6 of 20
Alarm Time Delays
Direct, 1X Amplitude and 2X Amplitude
You can program alarm delays using Rack
Defined as one of the following:
Configuration Software. RMS Acceleration, Peak Acceleration, RMS
Acceleration II Velocity, Peak Velocity, Band-pass peak
For all channel pair types excluding Acceleration, or Band-pass peak Velocity
Shaft Absolute Velocity and REBAM
Additionally, 1X Phase, 2X Phase and Bias
From one to 60 seconds in one second
Alert Voltage
intervals
Direct
0.1 seconds or from one to 60 seconds in
Danger
0.5 second intervals Defined as one of the following:
Shaft Absolute Velocity Velocity RMS Velocity, Peak Velocity, peak-to-peak
Displacement, Band-pass peak Velocity,
From one to 60 seconds in one second Band-pass, or Peak-to-peak
Alert
intervals Displacement
0.1 seconds or from one to 60 seconds in Direct, 1X Amplitud and 2X Amplitude
Danger
0.5 second intervals
Defined as one of the following:
REBAM
RMS Velocity, Peak Velocity, peak-to-peak
From the calculated minimum value to Displacement, Band-pass peak Velocity,
Alert Velocity II
400 seconds in one second intervals Band-pass, or Peak-to-peak
From the calculated minimum value to Displacement
Danger
400 seconds in 0.5 second intervals Additionally, 1X Phase, 2X Phase and Bias
Voltage
Static Values Shaft Absolute,
Radial Vibration
Static values are measurements used to monitor and Shaft Absolute,
Direct, Gap, 1X Amplitude, 1X Phase Lag
the machine. The 3500/42M Proximitor*/Seismic Velocity
Monitor returns the following static values: Direct, Gap, 1X Amplitude, 1X Phase Lag,
Circular Acceptance 1X Circular Acceptance Radius, 2X
Direct, Gap, 1X Amplitude, 1X Region Amplitude, 2X Phase Lag, 2X Circular
Phase Lag, 2X Amplitude, 2X Acceptance Radius
Radial Vibration
Phase Lag, Not 1X Amplitude and
Smax Amplitude
Thrust Position Direct, Gap
Differential
Direct, Gap
Expansion
Peak-to-peak, Gap,
Eccentricity
Direct Minimum, Direct Maximum
Spike, Element, Rotor, Direct, Gap,
REBAM
1X Amplitude, 1X Phase Lag
Direct
Page 7 of 20
Hazardous Area Approvals Environmental Limits
For the detailed listing of country and product specific When used with Internal/External
approvals, refer to the Approvals Quick Reference Termination I/O Module:
Guide, document 108M1756, at -30°C to +65°C
www.GEmeasurement.com. (-22°F to +149°F)
Operating
Temperature When used with Internal Barrier I/O
CSA/NRTL/C (Approval Option 01)
Module (Internal Termination)
Ex nC [ia] IIC T4 Gc 0°C to +65°C
Class I, Division 1, (32°F to +149°F)
Groups A, B, C and D
Storage -40°C to +85°C
Class I, Zone 2/0 Temperature (-40°F to +185°F)
When used with I/O module
AEx nC [ia] IIC T4 Gc 95%
ordering options and internal Humidity
Class I, Division 1 Non-condensing
barriers
Groups A, B, C and D
Page 8 of 20
Output Supply Parameters
The following values are accurate regardless of external barrier connections.
Supply
I/O Part and Parameters
Description Configuration
Order Options U I P
(V) (mA) (W)
Prox/Accel 23.9 45.5 1.09
128229-01 A 01 Prox/Seismic I/O Module with Internal Terminations Velomitor 23.9 45.5 1.09
Seismoprobe 6.82 2.75 0.02
Prox/Accel 23.9 45.5 1.09
Prox/Seismic I/O Module with External
128240-01 A 02 Velomitor 23.9 45.5 1.09
Terminations
Seismoprobe 6.82 2.75 0.02
Shaft Absolute I/O Module with Internal Prox & Velomitor 23.9 45.5 1.09
138708-01 A 07
Terminations Prox & Seismoprobe 6.82 45.5 0.31
Shaft Absolute I/O Modules with External Prox & Velomitor 23.9 45.5 1.09
138700-01 A 08
Terminations Prox & Seismoprobe 6.82 45.5 0.31
Prox/Accel 23.9 45.5 1.09
140471-01 A 09 Prox/Velom I/O Module with Internal Terminations
Velomitor 23.9 45.5 1.09
Prox/Accel 23.9 45.5 1.09
140482-01 A 10 Prox/Velom I/O Module with External Terminations
Velomitor 23.9 45.5 1.09
Page 9 of 20
Cables
Ordering Information
3500 Transducer XDCR signal to External
For the detailed listing of country and product specific Termination Block Cable
approvals, refer to the Approvals Quick Reference
129525 - AXXXX - BXX
Guide, document 108M1756, at
www.GEmeasurement.com.
A: I/O Cable length
Page 10 of 20
Spares Firmware & Software Requirements
3500/42M Proximitor*/Seismic 3500/01 software, version 2.50 or
176449-02
Monitor later
Prox/Seismic I/O Module with 3500/42M Proximitor*/Seismic 3500/02 software, version 2.20 or
128229-01
internal terminations Monitor later
Prox/Seismic I/O Module with
128240-01 3500/03 software, version 1.21 or
external terminations
later
3500/42M Prox/Seismic I/O
See the 3500 Internal Barrier
00530843 Module four-pin connector
Internal Barrier I/O Modules datasheet (part number
shunt
141495-01)
143489-01 3500/42M Monitor Manual
3500/42M Module Firmware,
I/O Module with Internal Barriers revision B
135489-01 (internal terminations, 4 x
Prox/Accel) 3500/01 Software, version 2.61
Shaft Absolute
DM2000 Software, version 3.10
I/O Module with Internal Barriers
135489-02 (internal terminations, 2 x The 3500 Proximitor / Seismic
Prox/Accel and 2 x Velomitor) Monitor, version M
I/O Module with Internal Barriers 3500/40M Module Firmware –
135489-03 (internal terminations, 4 x Revision 2.1
Velomitor)
3500/01 Software, version 3.30
Shaft Absolute I/O Module with 3500/02 Software, version 2.40
138708-01 REBAM
internal terminations 3500/03 Software, version 1.40
Shaft Absolute I/O Modules with DM2000 Software, version 3.40
138700-01
external terminations The 3500 Proximitor Monitor,
3500/42M Shaft Absolute I/O version M
00517018
Module 8-pin connector shunt 3500/42M Module Firmware,
Prox/Velom I/O Module with revision 2.10
140471-01
internal terminations Acceleration II,
3500/01 Software, version 3.20
Velocity II,
Prox/Velom I/O Module with DM2000 Software, version 3.30
140482-01 Circular Acceptance Region
External Terminations
The 3500 Proximitor Monitor,
3500/42M Prox/Velom I/O Module version M
00561941
10-pin connector shunt
Internal I/O Module connector
header, Euro style, 8-pin
00580434
Used on I/O modules 128229-01
and 138708-01
Internal I/O Module connector
header, Euro style, 10-pin
00580432
Used on I/O modules 128229-01
and 138708-01
Internal I/O Module connector
00502133
header, Euro style, 12-pin
Page 11 of 20
I/O Module Types
AXX Ordering
I/O Part Number I/O Description Transducer Type
Option
Seismoprobe
Prox/Seismic I/O Module with
01 128229-01 Prox/Accel and Velomitor are supported
internal terminations
but are not recommended.
Seismoprobe
Prox/Seismic I/O Module with
02 128240-01 Prox/Accel and Velomitor are supported
external terminations
but are not recommended.
External termination blocks cannot be used with Internal Termination I/O Modules. When ordering I/O modules with
external terminations, order the external termination blocks and cable separately for each I/O module.
Page 12 of 20
Graphs and Figures
This section includes the following graphs and figures:
n The front and rear views of the 3500/42M Proximitor*/Seismic Monitor
See Front and Rear Views of 3500/42M Proximitor*/Seismic Monitor on page 14.
See Additional I/O Modules of the 3500/42M Proximitor*/Seismic Monitor on page 16.
See Barrier I/O Modules of the 3500/42M Proximitor*/Seismic Monitor on page 18.
Page 13 of 20
Front and Rear Views of 3500/42M Proximitor*/Seismic Monitor
1: Status LEDs
2: Buffered Transducer Outputs
3: Prox/Seismic I/O Module with Internal Terminations
4: Prox/Seismic I/O Module with External Terminations
Page 14 of 20
Side View of I/O Modules
The I/O modules with internal or external terminations have the same jumpers.
Page 15 of 20
Additional I/O Modules of the 3500/42M Proximitor*/Seismic Monitor
Page 16 of 20
Side View of Additional I/O Modules
Prox/Velom I/O modules and Shaft Absolute I/O modules with internal or external terminations have the
same jumpers.
Page 17 of 20
Barrier I/O Modules of the 3500/42M Proximitor*/Seismic Monitor
Page 18 of 20
REBAM Channels
The following graphs show the maximum machine speed allowed for a monitor channel pair configured
for REBAM. The maximum speed depends on the number of rolling elements in the bearing.
The graphs are generated with the following assumptions:
n The rotor lowpass filter corner is set at 3.2 times the shaft speed.
n The spike highpass filter corner is set at four times the element pass frequency for the outer race (BPFO).
Page 19 of 20
Figure 2: Only one channel of a channel pair is enabled.