Course Contents
1. INTRODUCTION
2. BASIC ASSUMPTIONS
3. BASIC DESIGN RULES
4. MATERIALS
5. DESIGN OF BASIC MEMBERS
6. JOINTS
7. DESIGN OF COMPONENTS AND STRUCTURES
(Trusses and Purlins)
© Dr. A.L. Mrema, April 2010
1
1.0 INTRODUCTION ON CIB CODE
This present version of the Code was prepared by a Code Drafting
Sub-Committee Consisting of W18 members and representatives of
Confederation European des Industries du Bois (CEI-bois), on the
basis of comments from CIB-W18, ISO/TC 165. Timber Structures,
and CEI-bois. The code is similar to EC-5: Design of Timber
Structures; with minor differences.
The Code contains rules peculiar to the design of timber and wood-
based structures, and recommendation which define their validity. It
is equally applicable to both the deterministic and the partial of
design, provided material properties are derived from characteristic
values and suitable safety factors strength and stiffness are available
for the design calculations. It does not contain safety factors, partial
factors or loads since it is recognized that these are the
responsibility of national public authorities.
2
1.1 SCOPE
The primary purpose of this code is to provide an agreed
background for the international bodies and national committees
responsible for formulating timber codes, to ensure a reasonable
and consistent of timber structures. The code relates to the
structural use of timber and wood based materials and is intended
for use in design, execution and appraisal of structural elements
made from timber or wood products and of structures containing
such elements.
It is based on the principles of structural mechanics,
engineering design, and experimental data, interpreted
statistically as far as possible.
Deviations from the requirements of this code and the use of
materials and methods of design or construction of wood structures
not covered by this code are permitted when the validity is
substantiates by analytical and engineering principles or reliable test
data, or both, (it is flexible). 3
CONDITIONS FOR THE VALIDITY OF THIS CODE
4
1.3 Units
SI units are used as shown below:
Unit Abbreviation
Length Metre m
Mass Kilogram kg
Temp Degree oC o
C
Stress Pascal Pa (1Pa = 1N/m²)
Strength Pascal Pa (1MPa = 1 N/mm²)
1.4 Notation
Main symbols
h depth of a
A Area
beam
E Modules of Electricity
i radius of
F Force
gyration
G Shear Modulus
k factor; always
I Moment of Inertia
with a subscript (e.g
M Moment (Bending)
kmod)
V Shear force
a Distance L span, length
b width t thickness
d diameter, side measurement u displacement
for square nails x coordinate
e electricity y coordinate 5
f strength z coordinate
Notation
partial coefficient (load m bending
factor, material factor) t tension
λ slenderness ratio tor torsion
v Poisson’s ratio v shear
ρ relative density vol volume
σ normal stress w web
τ shear stress x related to the x-direction
φ ratio y related to the y-direction
The characteristics strength values are related also to a value of 0.20m 3 for the
tensile strength perpendicular to grain.
7
2.1.2 Mean values
For some elastic properties the mean values are also given in this code and are
defined at the same temperature and humidity conditions as the characteristics values.
Forest Industry
Processing of various species
- pine, cypress, podo. Then grading – A/B/C grades
marketing – sampling and testing to establish reasonable characteristics data).
fd = fk* kmod
m* n
kmod takes into account load duration and moisture class; kmod = modification factor.
m = partial coefficient for materials
n = partial coefficient for failure consequences
Moisture class 1
The moisture class is characterized by a moisture content in the materials
corresponding to a temperature of 20 + 2oC and the relative humidity of the
surrounding air only exceeding 0.65 for limited periods.
Moisture class 2
The moisture class is characterized by a moisture content in the materials
corresponding to a temperature of 20 + 2oC and a relative humidity of the
surrounding air only exceeding 0.80 for limited periods.
Moisture class 3
All other climatic conditions based on the moisture properties of ordinary
softwoods Figure 2.1 shows the moisture class dependent of temperature and
relative humidity. At normal temperatures the equilibrium moisture content in
most softwoods will not exceed 0.12 in moisture class 1 and 0.18 in Moisture
class 2. 9
1 .0 0
0 .8 0
Re la tive h u m id ity
0 .6 5
Moistu re cla ss 3
Moistu re cla ss 2
0 .5 0
Moistu re cla ss 1
0
-2 0 0 20 100
o
Te m p e ra tu re C
Figure 2.1: Moisture classes
10
Suggested Moisture Classes for TANZANIA
Moisture class 1:
Structure protected and ventilated in inland savannah areas.
Moisture class 2:
Structure protected and ventilated in higher rainfall highland
areas, intermediate tropical areas and lake zones.
Moisture class 3:
Structures in direct coastal tropical zone and all structures
exposed to the weather or under other adverse conditions e.g
in moist or unventilated rooms.
11
2.3 Load-duration classes
For strength and stiffness calculations actions shall be assigned to one of the
load-duration classes given in table 2.3.
12
For an intermittent load the load duration class may in certain cases be
determined corresponding to the accumulated loading time.
13
3.0 BASIC DESIGN RULES
General
Structures should be designed in such a way that there is a prescribed safety
against the limit states described below being reached. Furthermore, they should
be designed in such a way that when exposed to fire they have adequate load
carrying capacity and integrity for a certain duration of time, out of regard for
evacuation, limitation of flame spread and protection of firemen.
The mains structure should normally be designed in such a way that when
exposed to an accidental load it should not subsequently be damaged to an extent
disproportionate to the extent and probability of the original incident.
The design may be based on calculations, on testing, or on a
combination thereof.
15
3.1.2. Serviceability limit states
Serviceability limit states are related to the criteria governing
normal use.
Serviceability limit states may for example correspond to:
- deformations which affect the efficient use of a structure
or the appearance of structural or non-structural elements
- excessive vibrations producing discomfort or affecting
non-structural elements or equipment (especially if
resonance occurs)
- local damage (including cracking) which reduces the
durability of a structure or affects the efficiency or
appearance of structural or non-structural elements,
- local buckling of thin plates (for example in thin webs or
flanges) without rupture,
- excessive impressions due to stresses perpendicular to
the grain and not affecting the ultimate strength.
16
3.2. Verification of design
If the general condition for the actual limit state not being reached is expressed
as
Φ(F,f,a,µ,C) > 0 the design criterion will be
Φ(Fd,fd,ad,µd,C) > 0
where F = Actions
f = material properties
a = geometry factors
µ = covers uncertainties
C = constants including presented design constrains 17
3.2.1 Design values of actions
characteristic value, Fk
For serviceability limit states m = 1.0 and deflections are calculated with the
mean value of the elastic properties.
For the ultimate limit states m is prescribed by the relevant public authority.
Safety class n
Less serious 1.0 normal house and industrial roof structures
Serious 1.1 stairs, floor structures., trusses > 18.0m span
Very serious 1.2 public assembly, schools, dispensary..
20
3.2.3 Design values of geometrical parameters
ad = a + a ………………………………….(3.2.3a)
or
ad = a - a …………………………………..(3.2.3b)
For the strength values and design methods given in this code to be applicable,
individual members and cross-sections must be designed in accordance with
the theory of elasticity. However, the stress resultants, in for example lattice
structures, need not be calculated under the assumption of elastic behaviour.
For the serviceability limit states, elastic methods of analyses will usually be
appropriate. In the calculation of distribution of forces in statically
indeterminate structures, consideration should be given to slip in joints, etc.