Computer room air conditioning (CRAC) units provide temperature and humidity control for computer server rooms. They include components like filters, humidifiers, dehumidifiers, and sensors to maintain optimal conditions according to ASHRAE guidelines. Proper maintenance of CRAC units includes regular inspection and cleaning of filters, coils, fans, and other components to ensure efficient operation and prevent failures.
Computer room air conditioning (CRAC) units provide temperature and humidity control for computer server rooms. They include components like filters, humidifiers, dehumidifiers, and sensors to maintain optimal conditions according to ASHRAE guidelines. Proper maintenance of CRAC units includes regular inspection and cleaning of filters, coils, fans, and other components to ensure efficient operation and prevent failures.
Computer room air conditioning (CRAC) units provide temperature and humidity control for computer server rooms. They include components like filters, humidifiers, dehumidifiers, and sensors to maintain optimal conditions according to ASHRAE guidelines. Proper maintenance of CRAC units includes regular inspection and cleaning of filters, coils, fans, and other components to ensure efficient operation and prevent failures.
What is the CRAC units? Components of CRAC unit ASHRAE GUIDLINES Exclusion of ASHRAE guidelines • Tape library (storage devices) : rate of change (5°C in an hour, humidity is less than 5% rh per hour) • High density servers: operating at (18 to 22 °C, 50% rh) PH diagram Expansion valve Air Filters Filter dryer Oil separator Humidifier Dehumidifier Condensation pump Sensors and dampers Closed Control system & ATS Maintenance of CRAC units Daily • Inspect temperature and humidity set points. • Inspect obstructions on both inlet and outlet. • Inspect abnormal noises and vibration (whilst adhering to safety requirements). Monthly • Inspect fan assemblies (e.g. vibration, power consumption, noise, cleanliness). • Inspect for contamination (e.g. dust, debris, dirt, leakage). Maintenance of CRAC units Quarterly • Inspect/replace filters. • Inspect coil for damage, leakage and corrosion. • Inspect drain pan cleanliness and adequate drainage of condensation water. • Inspect humidification system (e.g. cleanliness, free flow of steam). • Inspect all moving parts for wear and tear, lubricate where required. • Inspect fan belts (where applicable) (e.g. wear and tear, tightness). • Inspect refrigerant system (e.g. pipe, insulation, levels). • Inspect connections to fire safety systems. • Inspect electrical parameters (e.g. voltage, current, harmonics, power factor). Maintenance of CRAC units Annually • Inspect pipes (e.g. water pipes, valves, refrigerant, insulation, drain). • Inspect damper settings. • Inspect sensors (e.g. calibrate). • Inspect electrical system (e.g. wiring, insulation, connections, labeling). • Make test and balance.