You are on page 1of 18

TJ1600CHANDOFF

Slot Allotment Details


• Slots 1, 2, 3, 4, 7, 8, 9, 10, and 11 for
Tributary cards
• Slots 5 and 6 for Cross-connect cards.
• Slots 12 and 13 for Power Filter Units
• Slot 14 for OAM card
• Slot 15 for Fan tray unit
TJ1600 POTP (11-Slot) chassis
HCPPFU02

 Following are the functional features of the HCPPFU02:


• Over Voltage, Under Voltage and Over Current
protections
• EMI filtering and hold up provision
• Hardware monitoring
• Power Supply: Single feed Dual Module(3-pin power D connector)
 Input: 3-pin Power Header Phoenix Contact
 Output: FCI Connector.
• Nominal input voltage: -48V
• Normal operation input range: -40V to -72V.
• Input voltage high/low alarm setting fixed : -56V/ -43.2V.
• Derived output voltage 48V.
• Derived voltage high /low setting is fixed (12%) :53.76 / 42.24.
• Every line card takes 48V.
• Continuous Reverse polarity protection up to 75V.
• Output Power delivered in fully loaded condition 2500W.
Fan Tray Unit HCPFTU01
Functional features of fan tray unit (HCPFTU01) are:
• Supports six fans.
• Fuse on each fan power supply to isolate any failed fan from other
fans.
• Fan speed monitoring and control through software, based on the
temperature sensed.
• Temperature monitoring on the airflow path
Field replaceable.
• Air filter is provided as separate Field replaceable unit in the system
• The system will work up to 40°C temperature in case of single fan failure.
An Alarm is raised if any of the fans fails (the Fan tray is provided with six
fans).
• The fan needs to be replaced, if an alarm exists on the FTU.
• If the alarm exists on the FTU and if the room temperature is below 40°C,
the system works unless the second fan fails.
HCPOAM01

• M1/F1: 1 F1 user data channel/MODEM interface, baud rate: 9600 - RJ 45


connector.
• ESI (External Synchronization Interface):
 1 clock in (2MHz) &/or 1 clock out (2MHz) – RJ45 connector and/or
 1 data in (2Mbps) &/or 1 data out (2Mbps)
 Data IN/OUT(BITS2), CLK IN/OUT.(BITS1)
• Alarm In interface: 7 external alarm in – RJ 45 connector.
• Alarm Out interface: 3 external alarm out (Critical, Major, Minor) – RJ 45
connector.
• LAN & Craft interface:
 CSMA/CD based LAN transceiver with 10/100Mbps HD/FD– RJ 45.
 Craft follows DHCP protocol with Auto IP detection mechanism & has fixed IP
address of 192.168.1.254
• O/W:64Kbps channel for voice communication – RJ45 connector.
• Inter & Intra ring segment order wire communication possible from R1.1.
• MGN1-5: Used for managing extended chassis and extended equipment .
• Maximum power consumption by card is 10W.
Card Population rule XCC01

• 80G (512x512 STM1/128x128STM4/32x32STM16)


digital cross connect capacity.
• Cross connect is grooming at the
level upto VC12/VC-11.
• μSD: 2GB, non-volatile.
• Supports XCC switchover over Card
Jack out and Force switchover from WUI.
• No traffic hit during switch over.
• Maximum Power dissipation : 150W .
Slot distribution for the HCPXCC01 cross connect card

Card Configuration No. of Service Ports Slot number

16xSTM-1/4
HCPULine01 4xSTM-16 1, 2, 3, 4, 7, 8, 9, 10, 11
Fixed mode of 16xSTM-1 where uplink gets
restricted to 2.5G
16xSTM-1/4
4xSTM-16
Supports 16x1GE ports

HCPSLine01 1, 2, 3, 4, 7, 8, 9, 10, 11
2xSTM-64
1xSTM-64 + 1x10GE 2xSTM-64
2x10GE Supports 2x10GE ports

CEL-3 16xFE + 4xGE 1, 2, 3, 4, 7, 8, 9, 10, 11


Card Population rule XCC03

• 340G (HO XC Only) or 320G (HO XC)+ 20G (Max LO


XC) digital cross connect capacity
(Strict Sense non blocking).
• μSD: 4GB, non-volatile.
• Supports XCC switchover over Card
Jack out and Force switchover from WUI.
• No traffic hit during switch over.
• Bandwidth allocation is from lowest
slot no. to highest slot no
• Temperature Monitoring.
• Early ejector support.
• DIAG interface: Local console login (tejas personnel
only) – USB connector.
• Maximum Power dissipation : 200W .
Slot distribution for the HCPXCC03 cross
connect card
Card Configuration No. of Service Ports Slot number

HCPULine01 Reconfigurable: STM-1/4/16 1, 2, 3, 4, 7, 8, 9, 10, 11


20xSTM-1/4
8xSTM-16
Supports 16x1GE ports (Except
P5, P10, P15, P20)

HCPSLine01 2xSTM-64 1, 2, 3, 4, 7, 8, 9, 10, 11


1xSTM-64 + 1x10GE 2xSTM-64
2x10GE Supports 2x10GE ports
HCPSLine03 SDH GATEWAY Card 4xSTM-64 1, 2, 3, 4, 7, 8, 9, 10, 11

P1 and P2: STM-64 + P3 to P10:


HCPSLine08 SDH GATEWAY Card STM-16 1, 2, 3, 4, 7, 8, 9, 10, 11
CEL-3 16xFE + 4xGE 1, 2, 3, 4, 7, 8, 9, 10, 11
HCPSLINE01

• Supports : 2x STM64
• Laser type: S64.1/L64.1/L64.2
• Backplane capacity of the card in XCC03/XCC04 : 20G
HCPULine01

Port Group-4(5G) Port Group- Port Group- Port Group-1(5G)


[5XSTM1/4] 3(5G) 2(5G) [5XSTM1/4]
[2xSTM16] [5XSTM1/4] [5XSTM1/4] [2xSTM16]
[4xGIGE] [2xSTM16] [2xSTM16]
[4xGIGE]

Backplane capacity of the card in XCC03/XCC04 : 20G


HCPSLine03

• Card configuration modes:

 SDH GATEWAY Card

• Backplane capacity of the card in


XCC03/XCC04 : 40G
HCPSLine08

Backplane capacity of the card in XCC03/XCC04 : 40G


CEL-3/ELAN07_GE_FE

• CEL-3 supports 16xFE ports and 4xGE ports. This card is supported in TJ1600 POTP
(11 slot) chassis.
• CEL-3 supports 16FE ports. The electrical interface is supported through a 16 Port
Ethernet Termination panel.
• Ethernet termination panel has sixteen RJ-45 interfaces on a panel.
CEL-3 Functional Features
• VCGs support both SDH and SONET
• Virtual concatenation for SDH/SONET
• LCAS to allow the dynamic hitless addition/deletion of bandwidth within a VCG
to cater for on demand bandwidth applications
• Jumbo frames up to 9216 bytes
• Higher order and lower order virtual concatenation
• L2 Physical parameters: auto-negotiation and flow control
Thank You