Standard Technical and Design Rollout 2024

智慧联接 美好生活 Smart Link Better Life.


Standard Technical and
Design Rollout
1 Conventional Solution

2 Quick ODN Solution

智慧联接 美好生活 Smart Link Better Life.


Conventional Design Standard

Cable Engineering specification. Cable Plan Civil Engineering specification.


Specification.
1. Splice Loss: 0.1dB 1. OTB termination: 20mslack 1. OTB ( ODF) - HH – FDT-HH pit-FAT--ONT
2. Termination Loss: 0.3dB 2. HH Feeder : 20mslack 2. HH – use for Splice Joint
3. Fiber loss : 0.25db/km@ 1550nm 3. HH FDT : 20m Slack 3. HH Pit for slack at section of distribution
4. Fiber loss : 0.35db/km@ 1310nm 4. Pole FDT : 20m Slack 4. Between splice HH – approximately 2km
5. Splitter Loss for 1:8 FDT = 10.5 dB 5. HH pit pedestal : 10mslack 5. Trench depth : 1.2m(feeder section), 30cm
6. FAT aerial : 20mslack; (distribution section)
6. Splitter Loss for 1:8 FAT = 10.5 dB
Boring Rojok depth: 1.2m
7. Connector Loss (SC/APC) ≤ 0.25 dB 7. Splicing point: 20m/sideslack;
8. Fast Connector SC Loss ≤ 0.4 dB 8. Cable drum = 4km
9. Maximum optical link loss = 32 dB
General Network Topology - DWG
Design - DWG

scenario
Design Splitting Scenario
• Type of FDT use ; FDT 48 Ports capacity (with 5 splicing & termination
unit, 5 slots for Splitter) connects maximum 40 FATs (assumption 1 FAT
contain 1 splitter).
• FAT aerial capacity is 16 ports contains of 2 slot splitter 1:8; One FAT
covers maximum of 16 HP.
• FAT underground capacity is 16 ports contains of 2 slot splitter 1:8; one
FAT cover max 16 HP.
• One distribution cable distributes 2 core to each FAT and splice 100%
(1 splitter = 1 core);
• For one FDT , feeder cable distribute “x” core depend to actual
needed/HP; (FDT 48 need maximum 5 core feeder). Feeder splice
provide 100% for main core based on cable capacity and sub feeder
based on number of core required.
• For feeder section, there are 4 types for cable use: 288/144/96/48
cores,we propose 288& / 144 cores cable for main route and other
type propose to use for sub-feeder.
• ……(continue)
Design - DWG

scenario Design using cascading splitting scenario :


Design Splitting Scenario
• For distribution section using 24/36 cores, optional 12/48 cores
• 2 cores everyone tube in distribution give for spare
maintenance and monitor link purpose; In Main Feeder,
allocated core for input FDT will be two time from total splitter
1:8 and will be allocate to each FDT (not each cluster) as
monitoring and spare (applied in new feeder line).
• 1:8 splitter will provide 50% from full capacity HP coverage, and
1:8 splitter will be provide 1 Pcs each FAT and handover to
operation team after ATP with customer done.
Design scenario - DWG

Design Drawing Cluster Splicing Sketch

• For each FAT, Splicing will be 50% from FAT capacity; means 1 core max per FAT will be splice (for UG scenario, splice max 1
core)
• 2 cores everyone tube in distribution give for spare maintenance and monitor link purpose; and will termination on FDT.
• Means only core (1- 10), (13-22), etc, will be use for distribution into FAT, others will terminate in FDT only and remarks as
spare.
• 1:8 splitter will provide 50% from full capacity HP coverage, and 1:8 splitter will be provide 1 Pcs each FAT and handover to
operation team after ATP with customer done.
Material
FDT
Stainless
: Steel/SMC/Metal/
Material standard Fiber Plastic
Dimension 600 x 600 x150
mm

Weight : 11.5 Kg
Operating condition
7.2.2.1 Operating temperature : -25°C~+40°C
7.2.2.2 Storage temperature : -25°C~+55°C
7.2.2.3 Relative humidity : ≤85%(+30°C)
7.2.2.4 Air pressure;
7 0 Kpa~ 1 0 6 Kpa 7 0 Kpa~ 1 0 6 Kpa
Port :
Density 48/72/96 Port
4 x 1:8 (for 48
Port)
Splitter Capacity : 9 x 1:8 (for 72
Port)
12 x 1:8 (for 96
Port)
12 splices in each
Splice Capacity : Clearview Cassette
IP Rate :
Material
FAT POLE
FAT OUTDOOR FAT OUTDOOR POLE
- DWG Material ADSS CABLE
Material Accessories

Dead End Steel Clamp Suspension Strand


messenger
3.5mm &
Buldogrip
DESIGN SPAN 50 METER
- DWG
FDT Pole (capacity 48) Design Changes:
- DWG

• Single Pole use for FDT placement


• Installation height of FDT 3m from surface.

• FO cable protected by Iron conduit flexible


pipe (anaconda)

• Slack cable at FDT pole mounted 5 m each


line.
• Slack hanger cable placement customize

for more than 1 cable due only have 1 slack


hanger in FDT.
Design Changes:
FAT Pole (Capacity 16) - DWG

• Despite FAT capacity are 16HP,

coverage on design maximum is 16 HP

• Every FAT will provide 1 unit splitter 1:8


and 2 cores for line connecting.

• Each FAT provide 15m slack cable and


7.5m on last FAT.
FAT Pole
FAT
Fiber Access Terminal which is in charge of
Aerial FAT
sharing distribution connections to each
customer. Placed on poles for aerial areas and
inside pedestals for underground areas

36
Design Changes:
FOC Splicing & Termination

• Each FAT in aerial will provide 1 cores


with 5 0 0 % termination splice. In

underground 1 core provide for


termination in FAT.

• In each 1 tube will be have 2 cores idle


pass through until last FAT.

FAT splicing and splitter installation • Termination in FAT will not cut the tube,
but only slice the tube to take core

needed.
FDT splicing and splitter installation • All cores in FDT will be termination and

For pigtail, coil two


connect to adapter port.
times at the left side
Note: coiling tray before
1. splicing the cable.
For outside cable, coil
two times before
splicing the cable.
Used PLC SC/APC
2.
Stripper Slitter Tube Cleaver
3. Fusion Splice Machine Protection Sleeve
Splicing Cassette
Cable Testing - ODF to FDT/FAT (OTDR) OTDR Testing Requirements:
- DWG

FDT/FAT • Testing Parameter using wavelength


ODF/FDT
1310nm and 1550nm.

• Bidirectional test (A-B, B-A) are mandatory


in feeder/sub feeder section.

• Unidirectional test (A-B) perform in


distribution/inside cluster section.

• Measurement in distribution section should


be as follows:
 In FDT : without connect to splitter 1:8
 In FAT : without connect to splitter 1:8
• Print out OTDR result and make summary
also.
Cable Testing - End to End Test (OPM) - DWG

Total Loss (dB) : n*(Connector Loss) + m*(Splicing Loss) + 1st Stage Splitter Loss + 2nd Stage Splitter Loss + Pre Connector Loss/Drop core +
Cable Loss

OPM Testing Requirements:

• Testing Parameter using wavelength 1490nm with OLT output as source.


• Unidirectional test (A-B) perform in feeder/sub feeder and cluster section

• Measurement in distribution section should be as follows:


 In FDT : Before splitter 1:8 and after splitter 1:8
 In FAT : Before splitter 1:8 and after splitter 1:8
• Record and make summary of OPM result
Sample Link Budget Calculation
Sample Link Budget Calculation
Sample Design : Kabel
ADSS
Sample Design : Kabel - DWG
ADSS
STANDARD POLE 7 M - 4 INCH-2.5mm
STANDARD POLE 7 M - 2.5 INCH-3mm
STANDARD POLE 8 M - 5 INCH-2.8mm
STANDARD POLE 6 M - 2 INCH-3mm
FAT coding for spraying paint
- DWG
STANDARD POLE 7 M - 4 INCH-2.5mm
STANDARD POLE 7 M - 2.5 INCH-3mm
STANDARD POLE 8 M - 5 INCH-2.8mm
STANDARD POLE 6 M - 2 INCH-3mm