Inspection of Double Tube Sheet Exchanger
Inspection of Double Tube Sheet Exchanger
3
1 HEAT EXCHANGERS DOUBLE
DOUBLE TUBESHEET
TUBESHEET EXCHANGERS
EXCHANGERS
INTEGRAL DOUBLE TUBESHEETS
ASSUMPTION:
Interconnecting cylinder and tubes are rigid enough to mutually transfer
all mech. and thermal axial loads between the tubesheets.
ASSUMPTIONS:-
No loads are transferred between the tubesheets.
7
2 HEAT EXCHANGERS
THUMB
THUMB RULES
RULES IN
IN STREAM
STREAM ALLOCATION
ALLOCATION
The higher pressure fluid normally flows through the tube side. With smaller
diameter and nominal wall thk. the tubes are better able to accept high
pressures.
Generally corrosive fluids are in the tubeside. This is much less expensive to
use the special alloys designed to resist corrosion for tubes than for shell.
Flow of higher fouling fluids through the tubes are easier to clean using
common mech. methods than the shell .
It is best to place fluids requiring low pressure drops in the shell circuit since
flexible combinations & configurations- affecting tube pitch, baffle use and
spacing, and multiple nozzles etc can be used when laying out the shell
circuit.
The fluid with lower heat transfer coeff. normally goes in the shell circuit
with this setup, low-fin tubing, which will increase available surface area,can
be used to offset the low heat transfer.
INTRODUCTION
10
3 HEAT EXCHANGERS INTRODUCTION
INTRODUCTION
TEMA provides option for using Double Tube sheet HE to get a better
contamination-proof joint.( ref.TEMA RCB pg.55-62)
Channel
Shell
Tubes
15
4 HEAT EXCHANGERS
TUBE
TUBE SHEET
SHEET DETAILS
DETAILS
TubeSheet - SA 350 Gr LF2. X 476 dia.
First T/s 46mm( inner) & second 71 mm ( outer).
Each T/s having two grooves of 3mm width and 0.4mm depth.
148 No of holes each of Dia. 19.25mm on 25.4mm traingular pitch.
17
5 HEAT EXCHANGERS
TUBE
TUBE TO
TO TUBE
TUBE SHEET
SHEET JOINT
JOINT
Tube SA 334 Gr 6 Size 19.05mmx 2.77 mm Thk
Fully expanded joint.
8 to 10% expansion
% Thinning check and air test after expansion.
19
6 HEAT EXCHANGERS
TUBE
TUBE SHEET
SHEET TO
TO TUBE
TUBE SHEET
SHEET JOINT
JOINT
REQUIREMENT OF MOCK UP
21
7 HEAT EXCHANGERS
REQUIREMENT
REQUIREMENT OF
OF MOCK
MOCK UP
UP
MOCK UP TESTING
23
8 HEAT EXCHANGERS
MOCK
MOCK UP
UP TESTING
TESTING
17 No of holes used.
Pull out test carried out on Hole nos. 4,9&14 ,surrounded by at least two
rows.
After satisfactory expansion, the joint with annular space was seal welded
first and then subjected to pneumatic test at 2.0 kg/cm2(g). pressure
followed by hydro test at 33.0 kg/cm2(g) and the results were leak tight.
The pull out loads were found to be satisfactory when the tests were done :-
2. Macro test was conducted after sectioning to confirm the proper flow of
tube material in the grooves after expansion, the flow of material was
satisfactory.
PROBLEMS INCURRED
29
9.1 HEAT EXCHANGERS
PROBLEMS
PROBLEMS INCURRED
INCURRED
In mock up stage , both ends of the tube sheets were accessible and hence it
was easy to check % expansion in both the tube sheets separately.
In actual job, only one end was accessible. So it required a long bore gauge
to check the expansion. Since the fabricator was not having the long bore
gauge,expansion of the outer T/s was checked and reported. The same was
referred to client for concurrence and was accepted by them based on
satisfactory mock up results.
BV insisted the above requirement for the T/S TO T/Sheet weld joint
Due to the joint geometry, radiography could not be realised. UT was the
next suggested alternative. Again due to joint configuration /lesser width
of joint & limitation of scanning area only a small portion could be
examined leaving out the critical root penetration.
To counter this, special care for the root pass was undertaken by keeping
3 visible ports for examining the root penetration visually. The root
penetration was found satisfactory.
As per approved QAP only MP examination was specified for this joint and
hence accepted on this basis.
CUSTOMER’S CONCURRENCE
34
10 HEAT EXCHANGERS
CUSTOMER’S
CUSTOMER’S CONCURRENCE
CONCURRENCE
CONCLUSION
36
11 HEAT EXCHANGERS
CONCLUSION
CONCLUSION
TEMA does not give too much details about such type of Double T/s HE.