Air blower with duct Grain discharging mechanism with a hopper bottom Air heating system
Heater
DRYER
Mass balance
Let W =WG1WG2 or WG1 =WG2 + W Amount of dry material entering into the dryer Amount of dry material leaving the dryer But (1m1/100)WG1 WG2 =(1m2/100)WG2 =WG1[(100m1)/(100m2) , kg/hr (2) =(1m1/100)WG1 =(1m2/100)WG2 , kg/hr , kg/hr (1)
Put equation (2) in equation (1) W =WG1WG1[(100m1)/(100m2) =WG1(m1m2)/(100m2) Similarly W =WG2(m1m2)/(100m1) WG1(m1m2)/(100m2) =WG2(m1m2)/(100m1) (3)
Heat balance
Sensible heats (Grain + Water) + Latent heat
WdxCPGx(TG2TG1) + WdxM1xCPWx(TG2TG1)
+ Wd(M1M2) =Qa(0.24+0.45H0)(T1T2) x t (5) (6)
Design a LSU dryer of 2.0 tonnes holding capacity with paddy at 18% m.c.
Air Density of air= 1.13kg/m3, Ambient air temperature= 30oC, RH of ambient air= 70%, Absolute humidity of ambient air= 0.019, Heated air temperature= 85oC, Exhaust air temperature= 35oC, Latent heat of water vapour= 600 kcal/kg,
Design a LSU dryer of 2.0 tonnes holding capacity with paddy at 18% m.c.
Paddy
Angle of repose= 45o, Specific heat of the grain= 0.4 kcal/ kg oC, Bulk density of paddy at 18% m.c.= 600kg/m3, Initial m.c. of paddy= 30%(w.b.), Final m.c. of paddy= 18%(w.b.), Grain inlet temperature= 30 oC, Grain outlet temperature= 70 oC, Grain residence time= 30 minutes
Design a LSU dryer of 2.0 tonnes holding capacity with paddy at 18% m.c.
Dryer Cross-section of the dryer= 1.2x1.2m2 Air velocity in the air ports= 5m/sec Pitch of the air ports= 40 cm Row to row spacing = 20 cm Height of the grain holding bin= 35 cm, Height of the hopper bottom= 60 cm, Diameter of the discharge roll= 2.5 cm, Diameter of flute= 7.5 cm, Discharge hopper angle= 50o.
Air
Density of air= 1.13kg/m3, Ambient air temperature= 30 oC, RH of ambient air= 70%, Absolute humidity of ambient air= 0.019, Heated air temperature= 85 oC, Exhaust air temperature= 35 oC, Latent heat of water vapour= 600 kcal/kg, Angle of repose= 45o, Specific heat of the grain= 0.4 kcal/ kg oC, Bulk density of paddy at 18% m.c.= 600kg/m3, Initial m.c. of paddy= 30%(w.b.), Final m.c. of paddy= 18%(w.b.), Grain inlet temperature= 30oC, Grain outlet temperature= 70oC, Grain residence time= 30minutes Cross-section of the dryer= 1.2x1.2m2 Air velocity in the air ports= 5m/sec Pitch of the air ports= 40 cm, Row to row spacing = 20 cm Height of the grain holding bin= 35 cm, Height of the hopper bottom= 60 cm, Diameter of the discharge roll= 2.5 cm, Diameter of flute= 7.5 cm, Discharge hopper angle= 50o.
Paddy
Dryer
Air requirement
Bone dry paddy = 2000 (10.18) = 1640 IMC = 30% w.b. 42.86% d.b. FMC= 18% w.b. 21.95% d.b. Weight of moisture evaporated Wt. of bone dry paddy x (FMC-IMC) 342.92 kg From psychrometric chart Specific heat
Air requirement
Heat Utilized 1. As sensible heat of grain = BD paddy x Sp heat Grain x Temp rise = 1640 kg x 0.4 kcal/ kg oC x (70-30) oC = 26,240 kcal 2. As sensible heat of water = Total wt of water x Sp heat Grain x Temp rise = (1640 x 0.42857 kg) x 1.0 kcal/ kg oC x (70-30) oC = 28,114.2 kcal 3. As latent heat of water vapour = Water evaporated x latent heat = 342.86 kg x 600 kcal/ kg = 2,05,715.04 kcal
Air requirement
Total Heat Utilized = Sum of 1, 2 and 3 = 26,240 + 28,114.2 + 2,05,715.04 = 2,60,069.24 kcal Suppose, heat loss = 10 percent Net heat requirement = {260069.24 kcal / (1-loss)} x 100 = 260069.24 kcal / 0.90 = 2,88,965.82 kcal Hence, Heat supplied = Net heat required 373 G = 2,88,965.82 kcal G = 774.71 kg/min
Drying chamber
G air supply in kg/min m3/min From psychrometric chart, humid volume of the ambient air = 0.88 m3/kg G = 774.71 kg/min x 0.88 m3/kg = 681.75 m3/min Since velocity of air inside the air port or duct is 5m/sec Total cross-sectional area of ducts required = (681.75 m3/min) / (5 x 60 m/min) = 2.27 m2 Therefore, volume of drying chamber V = Drying chamber volumeDucts volume = 1.2 m x 1.2 m x h m2.27 m2 x1.2 m = (1.44 h2.724) m3
Power requirement
Air requirement per m2
As calculated:
Air requirement 681.75 m3/min Total cross-sectional ducts area is 2.27 m2 681.75 m3/min 2.27 m2 = 300.33 m3min-1 / m2
From Shedds curve, static pressure drop for 32.12 m3min-1 / m2=8.13 cm of water per 30.48cm grain depth.
Depth of grain = 20cm So pressure drop = 8.13 x 20 / 30.48 = 5.42 cm of water Pressure drop in terms of air column= 0.0542x(1000kgm-3/1.13kgm3) = 47.95 m
Soybeans (PF=1.3) 10
2
Corn (PF=1.5)
Airflow, cfm/ft
Sunflower (PF=1.5)
1.3
1
0.1 0.001
0.01
0.027
0.1
10
Power requirement
HP req = Height of air column, m x air flow rate, kg/min 4500 47.95 m x 774.71 kg/min 4500
8.25 hp
System Fan
2000
2500
3000
Dia. of the discharge roll Dia. of flute Ht of the hopper bottom Discharge hopper angle
Drying chamber
Holding capacity of the dryer is 2000 kg at 18% m.c. and Bulk density of paddy at 18% m.c. = 600 kg/ m3 Hence V = 2000 kg / 600 kg m-3 = 3.33 m3 V = (1.44 h2.724) m3 h = (3.33 + 2.724) / 1.44 = 4.21 m Height of grain holding bin = 35 cm (assumed) Height of hopper bottom = 60 cm (approx) According to spacing (40 cm), number of ducts in a row = 1.20 m/ 40 cm = 3 and number of row in 4.21 m = 4.21 m/ 20 cm = 21
Total number of ducts = 20x3 = 60 (leaving 1 row for discharge rolls)
Drying chamber
Cross sectional area of each duct (b2/4) a = 2.27 m2 / 60 = 37.83 cm2 b = 12.3 cm
Let there be 3 discharge rolls having shaft diameter 2.5 cm and flute diameter 7.5 cm Vol discharged by each roll in one revolution = (7.52 2.52) 120 / 4 = 4712.39 cm2
Vol discharged by 3 rolls, m3/rev = 0.014137m3/rev Wt of paddy discharged, kg/rev = 0.014137 x 600 kg/m3
Since, grain retention time is 30 min
Grain discharge rate=2000/30 =66.67 kg/min Roller speed=66.67kg min-1/ 8.129kg rev min-1 =8 rpm
LSU dryer
Air requirement Bone dry paddy Weight of moisture evaporated Heat requirement considering heat loss
Blower power
Dryer dimensions Volume of drying chamber Cross sectional area of each duct Roller speed
Air requirement
Bone dry paddy = 2000 (10.18) = 1640 IMC = 30% w.b. 42.86% d.b. FMC= 18% w.b. 21.95% d.b. Weight of moisture evaporated Wt. of bone dry paddy x (FMC-IMC) 342.92 kg From psychrometric chart Specific heat
Air requirement
Heat Utilized 1. As sensible heat of grain = BD paddy x Sp heat Grain x Temp rise = 1640 kg x 0.4 kcal/ kg oC x (70-30) oC = 26,240 kcal 2. As sensible heat of water = Total wt of water x Sp heat Grain x Temp rise = (1640 x 0.42857 kg) x 1.0 kcal/ kg oC x (70-30) oC = 28,114.2 kcal 3. As latent heat of water vapour = Water evaporated x latent heat = 342.86 kg x 600 kcal/ kg = 2,05,715.04 kcal
Air requirement
Total Heat Utilized = Sum of 1, 2 and 3 = 26,240 + 28,114.2 + 2,05,715.04 = 2,60,069.24 kcal Suppose, heat loss = 10 percent Net heat requirement = {260069.24 kcal / (1-loss)} x 100 = 260069.24 kcal / 0.90 = 2,88,965.82 kcal Hence, Heat supplied = Net heat required 2232 G = 2,88,965.82 kcal G = 129.46 kg/min
Air requirement
G air supply in kg/min m3/min From psychrometric chart, humid volume of the ambient air = 0.88 m3/kg G = 129.46 kg/min x 0.88 m3/kg = 113.93 m3/min