You are on page 1of 4

STV EXTENSION STV SOUTH WEST PROJECT (SVSW) EPCI FOR WHP-SVSW, PIPELINES AND CPP SuTuVangSouthWest MODIFICATIONS

S VENDOR FRONT SHEET

DOCUMENT TITLE

DATASHEET FOR MAGNETIC LEVEL GAUGE & TRANSMITTER

TOTAL NO. OF PAGES


(INCLUDING FRONTSHEETS)

04

VENDOR'S ORDER NO. VENDOR'S APPROVAL (NAME AND SIGNATURE)

VENDOR'S OWN DOCUMENT NO

REV. NO

DATE

SVSW-004110-G16-0003

15-01-2013

LE ANH VU

Submitted For : REVIEW INFO APPROVAL FINAL DOCUMENTATION

STV EXTENSION STV SOUTH WEST PROJECT


SOUTHERN PETROLEUM CONSTRUCTION J.S.C

REVIEW DOES NOT CONSTITUTE ACCEPTANCE OF DESIGN DETAILS, CALCULATIONS, TEST METHODS OR MATERIALS DEVELOPED OR SELECTED BY VENDOR NOR DOES IT RELIEVE VENDOR FROM FULL COMPLIANCE WITH CONTRACTUAL OR OTHER OBLIGATIONS.

VENDOR NAME :

PACKAGE DESCRIPTION:

CHEMICAL INJECTION SKID

1. ACCEPTED

2. ACCEPTED, PROCEED WITH WORK AND INCORPORATE COMMENTS AND RE-SUBMIT 3. NOT ACCEPTED. REVISE AND RE-SUBMIT. 4. FOR INFORMATION ONLY. NO SIGNATURE REQUIRED.

TAG NOS.: LG/LIA 4208-1 PURCHASE ORDER NO: TBA

MODEL TYPE NOS.:

VDRL CATEGORY:

G16
VDRL PRIME CODE. SEQUENCE NO.: Rev.

REQUISITION NO. NAME : DATE : SIGNATURE :

SVSW-004110

G16

0003

Vendor Doc. No.

DATASHEET MAGNETIC LEVEL GAUGES & TRANSMITTERS


STV EXTENSION - STV SOUTH WEST PROJECT ( SVSW ) EPCI FOR WHP - SVSW , PIPELINES AND CPP MODIFICATIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 28 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 Tag Number Service P&ID No. Equipment No. Comply with NACE MR0175 Standard Hazardous Area Classification

Refer. Doc. No.

Sheet no. Rev. Item Tag no. Service

: : : :

SVSW-004110-G16-0003 1 of 3 A

: As listed below : As listed below

GENERAL

LG/LIA 4208-1 POUR POINT DEPRESSANT STORAGE TANK SVSW-004110-D10-0001 ABJ-4208 N/A Class l, Div. 2, Group D, T3

Upper Fluid Upper SG Pressure Temperature Design Pressure Design Temperature

Lower Fluid Lower SG

Air Unit barg


o

Pour Point 0.904 - 0.916 @ 16C Minimum Water Full + 0.05 barg 65/ 0 Normal ATM ABM Maximum -

PROCESS DATA

C barg
o

CHAMBER AND FLOAT

INDICATOR

Type Process Connection Measuring Length (C to C) (mm) Upper Conn. Location Top Connection Chamber Material Flange Material Vent Connection Gasket Material Bolt Material Type Color Tag Number Calibrated Range Output Signal Power Supply Housing Material Enclosure Protection Mounting

Lower Corn. Location Bottom Connection Chamber Size Float Material Drain Connection Tag Material Nut Material Scale

Magnetic Level Gauge 2 - ASME150# RF 1800 Side Flanged 316L SS 316L SS 3/4" NPTF 316 SS 316 SS Bargraph Yellow / BLack LIA 4201-1 0-100% 4 ~ 20 mA + HART 24 VDC (Loop Powered) 316 SS NEMA4X, NEMA7 Clamp to Chamber

Side Flanged MFR's Std 316LSS 3/4" NPTF 316 SS 316 SS 0-100%

Cable Entry Certification

M20 Factory Mutual (FM)

TRANSMITTER

OPTIONS

Electrical Heat Tracing Supply Voltage High Temperature Insulation Drain & Vent Valves Integral Indicator Transient / Lightning Protection

Set Temperature Cable Entry Valve Size & Material Indicator Scale

N/A N/A N/A Yes with Plug LCD Meter N/A

N/A N/A 3/4 NPTF & 316 SS 0-100%

PURCHASE

Manufacturer Level Gauge Model No. Transmitter Model No.

K-TEK KM26S.316.B2.FE.FE.B2.WR21.P7.P7.M1G.F.FLT01 AT200.BW.L.S.R1.M4A.X.FM-.MMS

REMARK:

Vendor Doc. No.

DATASHEET MAGNETIC LEVEL GAUGES & TRANSMITTERS


STV EXTENSION - STV SOUTH WEST PROJECT ( SVSW ) EPCI FOR WHP - SVSW , PIPELINES AND CPP MODIFICATIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 28 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 Tag Number Service P&ID No. Equipment No. Comply with NACE MR0175 Standard Hazardous Area Classification

Refer. Doc. No.

Sheet no. Rev. Item Tag no. Service

: : : :

SVSW-004110-G16-0003 2 of 3 A

: As listed below : As listed below

GENERAL

LG/LIA 4218-1 CORROSION INHIBITOR STORAGE TANK SVSW-004110-D10-0001 ABJ-4218 N/A Class l, Div. 2, Group D, T3

Upper Fluid Upper SG Pressure Temperature Design Pressure Design Temperature

Lower Fluid Lower SG

Air Unit barg


o

Minimum

PROCESS DATA

C barg
o

Corrosiom Inhibitor 0.916 @ 16C Normal ATM ABM

Maximum

Water Full + 0.05 barg 65/ 0

CHAMBER AND FLOAT

INDICATOR

Type Process Connection Measuring Length (C to C) (mm) Upper Conn. Location Top Connection Chamber Material Flange Material Vent Connection Gasket Material Bolt Material Type Color Tag Number Calibrated Range Output Signal Power Supply Housing Material Enclosure Protection Mounting

Lower Corn. Location Bottom Connection Chamber Size Float Material Drain Connection Tag Material Nut Material Scale

Magnetic Level Gauge 2 - ASME150# RF 1800 Side Flanged 316L SS 316L SS 3/4" NPTF 316 SS
316 SS

Side Flanged MFR's Std 316LSS 3/4" NPTF 316 SS 316 SS 0-100%

Bargraph Yellow / BLack LT 4218-1 0-100% 4 ~ 20 mA + HART 24 VDC (Loop Powered) 316 SS NEMA4X, NEMA7 Clamp to Chamber

Cable Entry Certification

M20 Factory Mutual (FM)

TRANSMITTER

OPTIONS

Electrical Heat Tracing Supply Voltage High Temperature Insulation Drain & Vent Valves Integral Indicator Transient / Lightning Protection

Set Temperature Cable Entry Valve Size & Material Indicator Scale

N/A N/A N/A Yes with Plug LCD Meter N/A

N/A N/A 3/4 NPTF & 316 SS 0-100%

PURCHASE

Manufacturer Level Gauge Model No. Transmitter Model No.

K-TEK KM26S.316.B2.FE.FE.B2.WR21.P7.P7.M1G.F.FLT01 AT200.BW.L.S.R1.M4A.X.FM-.MMS

REMARK:

Vendor Doc. No.

DATASHEET MAGNETIC LEVEL GAUGES & TRANSMITTERS


STV EXTENSION - STV SOUTH WEST PROJECT ( SVSW ) EPCI FOR WHP - SVSW , PIPELINES AND CPP MODIFICATIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 28 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 Tag Number Service P&ID No. Equipment No. Comply with NACE MR0175 Standard Hazardous Area Classification

Refer. Doc. No.

Sheet no. Rev. Item Tag no. Service

: : : :

SVSW-004110-G16-0003 3 of 3 A

: As listed below : As listed below

GENERAL

LG/LIA 6640-1 FRESH WATER STORAGE TANK ABJ-6640 N/A Class l, Div. 2, Group D, T3

Upper Fluid Upper SG Pressure Temperature Design Pressure Design Temperature

Lower Fluid Lower SG

Air Unit barg


o

Minimum

PROCESS DATA

C barg
o

Fresh Water 1.00 Normal ATM ABM

Maximum

Water Full + 0.05 barg 65/ 0

CHAMBER AND FLOAT

INDICATOR

Type Process Connection Measuring Length (C to C) (mm) Upper Conn. Location Top Connection Chamber Material Flange Material Vent Connection Gasket Material Bolt Material Type Color Tag Number Calibrated Range Output Signal Power Supply Housing Material Enclosure Protection Mounting

Magnetic Level Gauge 2 - ASME150# RF Lower Corn. Location Bottom Connection Chamber Size Float Material Drain Connection Tag Material Nut Material Scale 1600 Side Flanged 316L SS 316L SS 3/4" NPTF 316 SS
316 SS

Side Flanged MFR's Std 316LSS 3/4" NPTF 316 SS 316 SS 0-100%

Bargraph Yellow / BLack LT 6640-1 0-100% 4 ~ 20 mA + HART 24 VDC (Loop Powered) 316 SS NEMA4X, NEMA7 Clamp to Chamber

Cable Entry Certification

M20 Factory Mutual (FM)

TRANSMITTER

OPTIONS

Electrical Heat Tracing Supply Voltage High Temperature Insulation Drain & Vent Valves Integral Indicator Transient / Lightning Protection

Set Temperature Cable Entry Valve Size & Material Indicator Scale

N/A N/A N/A Yes with Plug LCD Meter N/A

N/A N/A 3/4 NPTF & 316 SS 0-100%

PURCHASE

Manufacturer Level Gauge Model No. Transmitter Model No.

K-TEK KM26S.316.B2.FE.FE.B2.WR21.P7.P7.M1G.F.FLT01 AT200.BW.L.S.R1.M4A.X.FM-.MMS