You are on page 1of 1

Multisim Convergence Assistant Summary Report Convergence Assistant Summary Report Outcome: The simulation error was corrected

successfully. Changes Made: -Relative error tolerance (RELTOL) was changed to 1.0000e-002

Multisim Convergence Assistant Log Step 1: Verifying Error Scenario ...completed. Step 2: Setting parameter Integration Method (METHOD) to Gear Simulating... ...completed. Simulation error still occurs. Step 3: Setting parameter Initial Conditions to Set To Zero Simulating... ...completed. Simulation error still occurs. Step 4: Setting parameter Maximum Timestep (TMAX) to 1.0000e-004 Simulating... ...completed. Simulation error still occurs. Step 5: Setting parameter Maximum Timestep (TMAX) to 1.0000e-003 Simulating... ...completed. Simulation error still occurs. Step 6: Setting parameter Relative error tolerance (RELTOL) to 1.0000e-002 Simulating... ...completed. Simulation error fixed. Step 7: Attempting rollback of Initial Conditions to Automatically Determine Simulating... ...Rollback successful. Step 8: Attempting rollback of Maximum Timestep (TMAX) to 1.0000e-005 Simulating... ...Rollback successful. Step 9: Attempting rollback of Relative error tolerance (RELTOL) to 1.0000e-003 Simulating... ...Error recurred - rollback unsuccessful. Step 10: Restoring value of Relative error tolerance (RELTOL) to 1.0000e-002 Step 11: Attempting rollback of Integration Method (METHOD) to Trapezoidal Simulating... ...Rollback successful. Convergence Assistant completed successfully.