Professional Documents
Culture Documents
Interface Relays Miniature Relays Standard Relays Long Life Relays Time Cubes and Relay-Modules DIN Relays Solid-State Relays Miniature Contactors
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
KAT 2008
Industrial Relays
Industrial relays
Se rie s
Interface Relays
Interface Module ultra slim Interface Module ultra slim Interface Module 2-pole Interface Module 2-pole
Relays for switching of PLC I/OS
So ck
6A 2A 10 A 8A 10 A 10 A 5A
C7 CR 31 C9 KR13 KR 23 KR 33
10 A 10 A 5A 3A 2x 3A 3x 3A
Miniature Industrial Relays 4-pole Miniature Signal Relays 2-pole Miniature Signal Relays 2-channel Miniature Signal Relays 3-channel
C2 C3 C4 C5
10 A 10 A 10 A 16 A
C21 C 22 C 31 C 32 C 33 C34 C 39
10 A 6A 10 A 6A 2x 10 A 2x 5 A 3x 5 A
LONG LIFE Industrial Relays 3-pole LONG LIFE Power Relays 2-channel LONG LIFE Signal Relays 2-channel LONG LIFE Signal Relays 3-channel
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Pa ge
10 10 11 11 12 13 14 16 17 18 19 19 19 22 23 24 25 28 28 29 29 30 30 30
Relays Overview
Co nta c
et
Industrial relays
Se rie s
DIN-Relais
Power Relays 1-pole Control Relays 2-channel Control Relays 3-channel Signal Relays 2-pole
Direct snap on Industrial Relays: Power Relay Contol Relay with twin contacts Signal Relay with gold contact Step-on/ Step-off Relay
So ck
6A 2x 3A 3x 3 A 1A 6A 6A 6A 2x 5 A 3x 5 A
Pa ge
36 36 36 36 36 37 37 37 37 UC 0,8 A 2x 0,8 A 5A 2x 2A Triac 0,8 A Triac 1,5A 40 40 40 40 41 41 41 42 42 42 43 44 45 45 46 46 2,5 A 2x 1,5 A 3x 1,5 A 3A 3A 250 mA 3x 2 A 2A 2x 150 mA 20 A 20 A 20 A 25 A 40 A 63 A 48 49 50 50 50 50
Outline Overview
Step-on Step-off Relays Power Relays 1-pole Power Relays 2-pole Control-/Signal Relays 2-channel Control Relays 3-channel
C 35 C 36 C 37 C 38 KA108 KA115 KA 208 KD125 KD 215 KD 315 KDM 3-24 KDW 3-24 CTV11 DIN 35 DIN 35 DIN 35
DC Solide State Relays 2-channel Universal AC Solide State Relays 1-channel Universal AC Solide State Relays 1-channel Universal AC Solide State Relays 2-channel Universal DCSolide State Relays 1-channel Universal DC Solide State Relays 2-channel Universal DC Solide State Relays 3-channel DC Motor Control Relays with brake function UC Solide State Changeover Relays Switching Amplifier 1-channel Switching Amplifier 3-channel Pulse Shaper Pulse Shaper
Triac 2x 0,8 A
Miniature Contactors
Universal Miniature Contactors Universal Miniature Contactors Installation Contactors
With 3 main contacts 20...63A and auxilliary twin signal contacts 10A. Contact openings >3 mm, test voltage 4000V. Specially suitable for save breaking in low voltage circuits.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
KAT 2008
Industrial Relays
Co nta c
et
General information
Contacts There are several different types of contact materials for relays. The main distinction can be made between single contacts and twin contacts. While single contacts are more suitable for higher loads, twin contacts are significantly more reliable for low switching loads, i.e. < 24 V, < 100mA. Contact material There is no all-purpose universal contact. AgNi is used as a standard contact material for a wide range of applications. For applications in aggressive atmospheres, AgNi contacts with hard gold plating (up to 10 m) are recommended. There is however no other purpose then corrosion protection during storage. Relays with tungsten pre-contacts are available for very high switching currents (up to 500A, 2.5 ms. Minimum load The minimum load values are recommended values under normal working conditions i.e. regular switching, no special ambient conditions, etc. Under these conditions reliable switching can be expected. Contact resistance In practice the contact resistance may vary depending on the switching load and other environmental conditions. For higher currents the contact resistance is around 10m. Contact spacing Normally all open contacts have an air gap between 0,5 .. .1.5mm. They are referred to as contacts according to the Low-Voltage Directives and associated standards. These contacts are not suitable for safe disconnection. For switching of DC loads, large contact clearances are requested for the quenching of the electric arcs. (Pls.refer to special relays: Series connections.) Switching capacity The contact switching capacity is the product of switching voltage and switching current. For AC, the permitted switching capacity is generally enough to handle the max. continuous AC1 current over the whole voltage range. It is not allowed to exceed the load limit curve for DC switching because a remaining switch-off-arc would destroy the relay immediately. The DC switching capacity is 100W (DC 1). Drive (coil) A distinction is made between standardised voltages according to EN 60947 as guaranteed values, and typical values which can be expected with a high degree of probability. Pick-up voltage, Release voltage The pick-up voltage is the voltage at which the relay engages safely. The typical trip voltage for DC is approx. 65% of Unom and approx. 75% of Unom for AC. The release voltage is approx. 25 %, resp. 60% of Unom. For DC, these voltages depend strongly on the temperature coefficient for Cu. This is however not the case for AC, where the constant inductive resistance over a wide temperature range is the controlling factor. Under voltages in AC relays results in humming and armature fluttering and should therefore be avoided. Operating voltage range The upper voltage limit of the coil is determined by the heat and the ambient temperature. The self-heating trough the contacts under high loads should not be underestimated since it may even be higher than the dissipated energy of the coil. Significantly high but short period overvoltage however provides no problem for intermittent operations. In doubt please consult our specialist or ask for the respective characteristic curve diagram. Coil connections Different coil connections can be integrated into the relay as an option. A costeffective freewheeling diode is available for DC coils. Please note that the stated release times are generally specified without the coil connection. While an additional LED status indicator has practically no effect, a freewheeling diode (D) will lead to an increase in release time by a factor 2 to 5, or 0 ms to 30 ms. For AC coils, VDRs or RC elements may be used. In this case resonance effects may have to be considered. VDRs and common RC elements may increase release times by < 5 ms. General design Comat (Releco) relays are made from carefully selected high-quality materials. The components comply with the latest environmental regulations such as RohS. The meticulous design makes the relays particularly suitable for any industrial application and engineering installation. The robust terminals, mechanical position indicator, dynamic and permanent hand activators, all integrated in the standard relay make them particularly service friendly. Colour coded hand test buttons dependent on the type of coil voltage is another useful feature. Options - Different coil connections - Freewheeling diodes - LED displays - Bridge rectifiers for AC/DC drives, etc. Additionally, because of short-term availability of special versions for practically any drive voltage up to DC 220V / AC 400 V the relays are a cost effective solution for many applications For safety reasons, manual operated test buttons may be replaced with a blank button, if required. Further information To select the most suitable relay and to guarantee a reliable operation and a long service life for the application, several factors need to be considered. In particular these are: -Number of cycles -Switching frequency -Ambient conditions -Load type -Switch-on current and load switch-off energy. Example If the number of cycles are expected to exceed > 100,000 operations per year. (E.g. clock generators, fast running machines), an electronic solution is perhaps more appropriate. Comat is able to offer a suitable relay from our standard product range. In AC applications, crosstalk caused by long control leads is often a problem and can result in constant humming of the relay or even inadvertent triggering due to interference. Here too, we offer solutions. Various, apparently harmless loads may lead to very high switch-on currents or switch-off energy values This may result in an unacceptable reduction of the service life. Inductive DC loads are especially harmful. Characteristics of various loads: Heating circuits No high switch-on currents, no high switch-off loads. Incandescent lamps, halogen lamps Switch-on currents during a few ms in the range 10 x rated IN. Switch-off at rated load. Low-energy lamps Very high, with very short switch-on currents due to built-in decoupling capacitors. Contacts have a tendency to fuse. Transformers, AC contactors Switching on during zero-transition may avoid high inrush currents. If switching before or after the zero crossing, switch-on currents of 8. . .15 x rated IN.may occur. High inductive switch-off energy is possible. The load must be wired, due to EMC problems.
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
Industrial Relays
Interface Relays
Triac
CINT18 CINT28
CINT15 CINT25
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
Solid-State
&
KAT 2008
Industrial Relays
Interface modules
AC 230VA
Interface-Solide-State Modules
DIN
12 11 14
12 NC COM 11
Max. 6A 250V (see module)
12 11 14
AVING SPACE S
RELAY (+) RELAY
14
COMAT SOCKET
12
11
CINT1/ UC6-24VU
LABEL
OUT
NO
14
LABEL
CINT12/UC24V
(+)
A2
A1
MODULE
SOCKET
MODULE
CINT-R2/ UC24VU
RELAY
RELAY
A1(+)
COIL
MADE IN EC
A2()
and others:
www.comat.ch
Data at Tamb. =20C (standard coil)
Contact material Switching power AC1 Switching power DC1 Switching power AC15 Peak inrush current Switching cycles: mechanical/electrical Contact resistance/voltage drop Operation voltage AC50/60Hz / DC Power consumption Pmax. 24V Power consumption Pmax. AC230V On delay/release time Parallel circuit
UC
50/60 Hz /
DC
10%
Ordering example Module dinterface CINT-21/UC24V Accessories/Sparte parts Connector bridge CINT-BR20
(packing unit: 2x 10pin)
14
88,5
47.0
14
TS 35
93,5
49,2
TS 35
41,5
A1
A1 A2
A2
6,2
3,4
73
6,2
44,3
10
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
01
01
A1
6-24 6-24
14 11 SOCKET 12
A2
A1 A2
A1 A2
6,2
With cage clamp terminals (1x 0,2 - 2,5 mm 2) CINT-21, -22, -25, -28
CINT-11, CINT-21
Interface Module
for PLCs and process control. High power contact AgSnO2. With screw terminals (CINT-11) or cage clamp terminals (CINT-21).
CINT-12, CINT-22
Interface Module
for PLCs and process control. Signal contact AgNi +5 Au. With screw terminals (CINT-12) or cage clamp terminals (CINT-22).
CINT-15, CINT-25
Interface Module
for PLC`s and process control. DC solid-state switch NO, pnp. Integrated transient clamp circuit. For fast and high frequency switching. With screw terminals (CINT-15) or cage clamp terminals (CINT-25).
CINT-18, CINT-28
Interface Module
for PLC`s and process control. AC solid-state switch type NO synchronous switching triac. For fast and high frequency switching. With screw terminals (CINT-18) or cage clamp terminals (CINT-28).
MAX MIN
6 A 250 V A
10mA 12V
6 A 250 V A
1mA 1V
2 A 24 V D
1mA 6V
2 A 250 V A
10mA 12V
0,7...1,25Un 0,8...1,2UN 0,8...1,2UN 240mW 240mW 240mW 1,1W 1,1W 5ms/10ms <1ms 5ms/10ms All modules have an internal parallel diode circuit; green LED status indication. 24, 230 CINT-11/UC.....V CINT-21/UC.....V 24, 230 CINT-12/UC.....V CINT-22/UC.....V CINT-15/DC24V CINT-25/DC24V CINT-R1/UC110-240V CINT-R1/UC24V CINT-R2/UC110-240V CINT-R2/UC24V CINT-R5/DC24V
12 11
12 11
3,4
73
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Interface Modules
Industrial Relays
RELAY
DIN
CINT-52/62 CINT-53/63
A1 A2 SOCKET 12 11 14 22 21 24
With cage clamp terminals (1x 0,5 -2,5 mm 2) CINT-61, -62, -63
CINT-51, CINT-61
Interface Module Complete with integrated LED and relay.ul.
Test voltage: 3600V Isolation / // / : 4000Vrms // 2000Vrms Tamb. operation/storage:
CINT-52, CINT-62
Interface Module
for PLCs and process control. 1x CO signal contact AgNi+5 Au. With screw terminals (CINT-52) or cage clamp terminals (CINT-62). With LED output status display.
Interface Module
for PLCs and process control. 1 x CO high power contact AgSnO2. With screw terminals (CINT-51) or cage clamp terminals (CINT-61). With LED output status display.
-20..+55/ - 40..+85C
and others: MAX MIN
10 A (13 A) 250 V A
50mA 24V
8 A 250 V A
1mA 12V
8 A 250 V A
10mA 24V
www.comat.ch
Data at Tamb. =20C (standard coil)
Contact material Switching power AC1 Switching power DC1 Switching power AC15 Peak inrush current Switching cycles: mechanical/electrical Contact resistance Operation voltage AC50/60Hz / DC Power consumption Pmax. 24V Power consumption Pmax. AC230V On delay/release time Parallel circuit
AgSnO 2 2500VA ...300W 300VA /230V 100A /5ms 10x106 /105 <100m
0,8...1,2UN 0,8...1,2UN 0,8...1,2UN 480mW 480mW 480mW 1,1W 1,1W 1,1W 5ms /10ms 5ms/10ms 5ms/10ms All modules have an internal parallel diode circuit; green LED status indication. 24, 230 CINT-51/ UC.....V CINT-61/ UC.....V CINT-R21/UC110-240V CINT-R21/UC24V 24, 230 CINT-52 / UC.....V CINT-62 / UC.....V CINT-R22/UC110-240V CINT-R22/UC24V 24, 230 CINT-53 / UC.....V CINT-63 / UC.....V CINT-R23/UC110-240V CINT-R23/UC24V
UC
50/60 Hz /
22 NC 12 21 COM 11 24 NO 14
22 NC 12 21 COM 11 24 NO 14
Ordering example Interface module CINT-51/UC24V Accessories/Spare parts Connector bridge CINT-BR8/5
(packing unit: 1x 5 pieces)
48,5
TS 35
RELAYS
RELAYS
91
93
42,5
220-240 VU
A1 A2
A2
14
3,4
72
14
72
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
11
KAT 2008
UR PLC FOR YO
A1 A2
B1 B2
24 V 300 mA
24V AC/DC
B1
24V AC/DC
24V 300mA
B2
A1(+)
A2()
CHA1 / UC 24 V U ON
B1 S
B2
A1(+)
A2()
ON OFF AUTO
ON OFF AUTO
A3
01
11
12
14
MADE IN EC-01
10A 250V
AUT
10A 250 VA
OFF ON
01
A3
11
12
14
11 A3
10A 250V
12 14
CHA1
Interface Module
Complet with hand switch and LED for AUTO position indication. Test voltage: 3000V Tamb. operation/storage: -10..+50/ - 40..+85C
Interface Module
for control systems with 1x CO high power contact, 1x NO signal contact 300mA. Installation: 45mm front dimension. Front setting: AUTO-ON-OFF for maintenance and emergency operation
and others:
www.comat.ch
Data at Tamb. =20C (standard coil)
MAX MIN
10 A 250 V A
10mA 12V Power contact AgCdO 10A 250V 2500VA 500VA/230V ...250W 100A 2,5ms 10x106 <100m 0,8..1,2UN 1,1UN (10A) 400mW/24V CHA1/UC24V Signal contact Ag 300mA /30V 10VA 10W 0,5A 103 <100m
Contact material Switching current/voltage Switching power AC1 Switching power AC15 Switching power DC1 Peak inrush current Mechanical switching cycles Contact resistance Operation voltage AC50/60Hz Operation voltage DC Power consumption Pmax
UC
50/60 Hz /
A1 A2
B1 B2
TS35
84
45
26,5 17 58
12 14
12
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
62
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Power Relay
Control Relay
3 Au
Signal Relay
Industrial Relays
10 Au
AC230V
DC24V
UC24V
WH: 12,5 x 29
RELAY
RELAY
RELAY
RELAY
C14 - A10
1-pole Miniature Industrial Relay
Extremley rigid terminal pins (Faston 4,8mm) Test voltage: 5000V Tamb. operation/storage: -20..+60/ - 20..+100C
C10 - A10
Universal Power Relay 10 A
for AC- and DC-circuits ranging from 10mA 10V. With lockable manual activation button and mechanical status display.
C10 - T13
Relay like .. A10, but with twin contacts 6 A
the control relay with highest switching reliability for control circuits ranging from 5mA 5V. With lockable manual activation button and mechanical status display.
C10 - T12
Relay like ..T13, but with 10 gold plated twin change over contacts
for highest switching reliability. Suitable for signal circuits ranging from 1mA 5V. Recommended for applications up to 0,2A 30V. With lockable manual activation button and mechanical status display.
and otheres:
www.comat.ch
Connection No. on socket
MAX MIN
10 A 250 V A
10mA 10V 3 2 1 12 11 14
z
10 A 250 V A
10mA 10V 3 2 1 12 11 14
z
6 A 250 V A
5mA 5V 3 2 1 12 11 14
z
6 A 250 V A
1mA 5V 3 2 1 12 11 14
z
+
A2 5 A1 4 A2 5
+
A1 4 A2 5
+
A1 4 A2 5
+
A1 4
Contact material Switching load AC1/ DC1 Peak inrush power Switching cycles mech./electr. (AC1) Operation voltage AC 50 Hz / DC Power consumption AC / DC Triggering delay / release time
Standard
AgNi 2500VA/...300W//10A 30VD 30A(20ms) 20 x106/105 0,8...1,2UN 1,1VA/700mW 11/8ms 24, 115, 230 / AC ..... V
AC
50/60Hz C14-A10
Standard
AC
50/60Hz C10-A10X 24, 48,110 / DC ..... V
C10-T13X
C10-T12X
Standard
DC
20% C14-A10
Standard
DC
20%
12, 24, 48,110 C10-A10X / DC ..... V 12, 110 C10-A10FX / DC ..... V 24, 48 C10-A10BX / UC ..... V
12, 24, 48,110 C10-T13X / DC ..... V 12, 110 C10-T13FX / DC ..... V 24, 48 C10-T13BX / UC ..... V
12, 24, 48,110 C10-T12X / DC ..... V 12, 110 C10-T12FX / DC ..... V 24, 48 C10-T12BX / UC ..... V
F XX BX
DC DC
20% 20%
UC
50-400 Hz /
12 11 14
12 11 14 3 2 1
Term. 2 (11)
S10-B
75
(Option)
Ordering example Relay C10-A10X/DC24V Socket CS-106 (clip incl.) Connector S10-B
Term. 5 (A2) S10-B Incl. Clip S10-CG *)
5 CS-116 6 4 5 CS-116 6 4 A2 A2 A1 A2 A2 A1
75
Busbar S10-B
23
35,5 / 31 (C15)
17
23
35,5 / 31 (C14)
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
13
KAT 2008
Signal Relay
10 Au
DC24V
WH: 12,5 x 29
RELAY
RELAY
C10: 35,5
C12-A 21
2-pole Miniature Industrial Relay
Rigid terminal pins Test voltage: 5000V 3000V Tamb. operation/storage: -20..+60/ - 20..+100C
C12- A 22
Signal Relay 5 A
With gold plated twin change over contacts for increased switching reliability. Suitable for AC- and DCcircuits ranging from 5mA 5V. With lockable manual activation button and mechanical status display.
UniversalControl Relay 5 A
With two change over contacts for AC- and DC- circuits ranging from 10mA 10V. With lockable manual activation button and mechanical status display.
and otheres:
www.comat.ch
Connection No. on socket
MAX MIN
5 A 250 V A
10mA 10V
9 8 7 3 2 1 12 11 14
5 A 250 V A
5mA 5V
9 8 7 3 2 1 12 11 14
22 21 24
z
22 21 24
z
+
A2 A2 5 6 A1 4 A2 A2 5 6
+
A1 4
Contact material Switching load AC1/ DC1 Peak inrush power Switching cycles mech./electr. (AC1) Operation voltage AC 50 Hz / DC Power consumption AC/DC Triggering delay / release time
Standard
AgNi + 0,3 Au 1250VA/...150W// 5A 30VD 15A(20ms) 10x106/105 0,8...1,2UN 1,1VA/700mW 10/8ms 115, 230 / AC ..... V
AgNi+10 Au 1250VA/...150W// 5A 30VD 15A(20ms) 10x106/105 0,8...1,2UN 1,1VA/700mW 10/8ms 115, 230 C12-A22X / AC ..... V 12, 24, 48, 110 C12-A22X / DC ..... V 12, 110 C12-A22FX / DC ..... V 24, 48 C12-A22BX / UC ..... V
AC
50/60Hz C12-A21X
Standard
DC
20%
12, 24, 48, 110 C12-A21X / DC ..... V 12, 110 C12-A21FX / DC ..... V 24, 48 C12-A21BX / UC ..... V
F XX BX
DC DC
20% 20%
UC
50-400 Hz /
Conductor bridge for interface socket CS-112 and CS-116 Type: V10-G V10-R V10-B V40-G
75
V40-R V40-B
Ordering example Relay C12-A21X/DC24V Socket CS-112 (clip incl.) Conductor bridge V40-B
5 CS-112 6 4 5 CS-112 6 4 A2 A2 A1 A2 A2 A1
A2 -A2
17
14
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Industrial Relays
Miniature Relays
&
www.comat.ch
Remanence
KR13
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
15
KAT 2008
Industrial Relays
DC 24 V D
AC 230V A
DC 24 V D
AC 230V A
37,5
WH: 21x 28
C7-A 20
2-pole Miniature Industrial Relay
lockable manual operation mechanical flag indicator Test voltage: 2500V 2500V
C7-T21
Relay like .. A20, but with twin contacts 6A
the control relay with highest switching reliability for control and signal circuits ranging from 5mA 5V.
C7-T22
Relay like .. T21, but 10 gold plated contacts
the twin contact relay with highest switching reliability for signal circuits ranging from 1mA 5V. Recommended upto 0,2A 30V.
C7- H23
Power Relay 10 A
with supplementary twin contact 6A (3zAu) for a secondary circuit switch, i.e. to ensure reliable signal of relay switch position to the central control, SPC, distribution system.
C7-W10
Heavy duty Relay for 500 A inrush current
with tungsten special early make contact. Specially suitable for filament and halogen lamps, transformers, etc. No mecanical flag indicator.
and others:
www.comat.ch
Connection No. on socket
MAX MIN
10 A 250 V A
10mA 10V 4 2 3 1 24 22 14 12
z
6 A 250 V A
5mA 5V 4 2 3 1 24 22 14 12
z
6 A 250 V A
1mA 5V 4 2 3 1 24 22 14 12
z
10 / 6 A 250 V A
10mA 10V // 1mA 5V 4 2 3 1 24 22 14 12
z
10 A 250 V A
10mA 10V 4
+
A2 21 8 6 4 6 2 24 22 21 11 A1 5 7 3 5 1 14 12 11 A2 21 8 6 4 6 2 24 22 21
z
+
11 A1 5 7 3 5 1 14 12 11 A2 21 8 6 4 6 2 24 22 21
z
+
11 A1 5 7 3 5 1 14 12 11 A2 21 8 6 4 6 2 24 22 21
z
+
11 A1 5 7 3 5 1 14 12 11
z
A2 8 5 4 5
A1 + 7
+
A2 8
Data at Tamb. =20C (standard coil)
+
A2 8 AgNi+0,2zAu 1200VA ...150W 15A(20ms) 20x106/ 2x105 0,8...1,2UN 1,5VA/1W 16/8ms 24, 48, 115, 230 X / AC ..... V A1 7 A2 8 AgNi+10zAu 1200VA ...150W 15A(20ms) 20x106/ 2x105 0,8...1,2UN 1,5VA/1W 16/8ms
+
A1 7 A2 8
+
A1 7 A2 8
+
A1 7
A1 7
Contact material Switching power AC1 Switching power DC1 Peak inrush power Switch. cycles mech./electr. (AC1) Operation voltage AC 50 Hz / DC Power consumption AC/DC Triggering delay / release time
Standard
AgNi 2500VA ...250W 30A(20ms) 20x106/ 3x105 0,8...1,2UN 1,5VA/1W 16/8ms 24, 48, 115, 230 C7-A20 X / AC ..... V 12, 24, 48, 110, 125 C7-A20 / DC ..... V 12, 24, 48, 110, 125 C7-A20D X / DC ..... V Option X = with
AgNi // AgNi+3zAu 2500VA // 1500VA ...250W // ...180W 30A // 15A(20ms) 20x106/ 2x105 0,8...1,2UN 1,4VA/1,1W 15/8ms (30ms DX) 230 / AC ..... V
W/Ag 2500VA ...250W 500A(2,5ms) 20x106/ 3x105 0,8...1,2UN 1,8VA/1,5W 20/10ms 24, 48, 115, 230 C7-W10 X / AC ..... V 12, 24, 48, 110, 125 C7-W10 / DC ..... V
AC
50/60Hz
C7-T21
24, 48, 115, 230 C7-T22 X / AC ..... V 12, 24, 48, 110, 125 C7-T22 / DC ..... V 12, 24, 48, 110, 125 C7-T22D X / DC ..... V
C7-H23X
Standard
DC
10%
12, 24, 48, 110, 125 C7-T21 / DC ..... V 12, 24, 48, 110, 125 C7-T21D X / DC ..... V
D, DX
DC
10%
24 C7-H23DX / DC ..... V
= Type X (option)
Entire series of C7. Comply to IEE 323 and IEE 344 (seismic qualified) Interface socket CS-109 (all connections on top)
24 22 14 12 4 21 6 2 3 11 2 5 1 24 22 14 12 4 21 6 2 3 11 5 1
Ordering example Relay C7-A20X/AC230V Socket ... Socket CS-18 Retaining clip RC-G (option) Socket CS-109 (clip incl.) A2-connector S7-B (option) Socket S7-P (page 5*) Retaining clip RC-G (option)
2 4 6 8 1 3 5
75
CS-18
Clip RC-G
CS-109 CS-109
S7-B
7 A1
21 11
75
8 A2
7 A1
8 A2
(A2)
Clip S9-CG
22,5
22
37,5
22,5
16
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Power Relay
Industrial Relays
CR31 Miniature
CR31/AC230V A
MADE IN EU
CR31D/DC24V D
01
01
MADE IN EU
NC NO COM
+
AgNi
10A 250Va
AgNi
10A 250Va
22 2124 32 3134121114 A2
285396174
A1
22 2124 32 3134121114 A2
285396174
A1
CR31
3-pole Miniature Industrial Relay
lockable manual operation mechanical flag indicator Test voltage: 2500V 2500V Tamb. operation/storage: -40..+60/ - 40..+80C
and others:
www.comat.ch
Connection No. on socket
MAX MIN
10 A 250 V A
10mA 12V
2 8 5 3 9 6 1 7 4 22 21 24 32 31 34 12 11 14
A2 A2 14 14 AgNi 90/10 2500VA/...250W 20A(20ms) 20x106/105 0,75-1,7UN /0,8-1,65UN 1,0VA /0.75W AC:<25/10ms; DC:15/10ms 15/25ms 24, 115, 230 / AC ..... V 24 / DC ..... V 24 / DC ..... V
+ A1
13
Contact material Switching power AC1/DC1 Peak inrush power Switch.cycl. mech./electr.(AC1) Operation voltage DC/AC50Hz Power consumption AC/DC Trigg.delay/release time Trigg.delay/release time DC
Standard
AC
50/60Hz C31
Standard
DC
10% C31
F XX
DC
10% 20% C31D
9 7
1 31 1
5N
24
O
6 4
34 1 4
2N
22
C
3 1
32 12
Relay
75
12 A 300 V
COIL
Ordering example
LED or R/C-Module
MADE IN EU
R/C-Unit
CS-30
Ind.Relay CR31/DC24V Socket CS-30 (clip incl.) LED-Mod. CMX1/UC24-60V Retaining clip CC-30
A2
A1 +
14 13
4k7/0,01F
CMR1/ UC110-240V
32
26
27
470E/0,22F
CMR1/ UC24-60V
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
17
KAT 2008
Signal Relay
10 Au
Remanence Relay
AC 230V A
DC 24 V D
AC 230V A
37,5
WH: 21x 28
C9 -A41
4-pole Miniature Industrial Relay
lockable manual operation mechanical indication Test voltage: 2500V 1000V Tamb. operation/storage: -20..+60/ - 40..+85C
C9 - A42
Relay like ..A41, but with 10 z gold plated contacts
for control and signal circuits ranging from 5mA 5V. Recommend. upto 0,2A 30V.
C9 -R21
Remanence Relay with AC or DC coil
A1(13) = ON; A3 (10) = OFF. Minim. triggering time 50ms, permanent triggering admissible. Test voltage 2500V . Without option X.
and otheres:
www.comat.ch
Connection No. on socket
MAX MIN
5 A 250 V A
10mA 10V 8 4 44 42 7 3 6 2 34 24 32 5 1 14 12
z
5 A 250 V A
5mA 5V 8 4 44 42 7 3 6 2 34 24 32 5 1 14 12
z
5 A 250 V A
10mA 10V 8 4 24 22
ON
5 1 14 12
z
22
22
+
A1 21 11 10 13 9 41 31 12 14 1 1
+
A2 41 31 12 14 1 1 A1 21 11 10 13 9
+
A1
A2 21 12 14
OFF
A3 11 10 13 9
Contact material Switching power AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1) Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / release time
Standard
AgNi+0,2zAu 700VA/...75W 15A(10ms) 20x106/ 105 0,8...1,2UN 1,5VA/1W 10/6ms 24, 48, 115, 230 C9-A41 X / AC ..... V 12, 24, 48, 110, 125 C9-A41 / DC ..... V 12, 24, 48, 110, 125 C9-A41D X / DC ..... V Option X = with
AgNi+10z Au 700VA/...75W 15A(10ms) 20x106/ 105 0,8...1,2UN 1,5VA/1W 10/6ms 24, 48, 115, 230 C9-A42 X / AC ..... V 12, 24, 48, 110, 125 C9-A42 / DC ..... V 12, 24, 48, 110, 125 C9-A42D X / DC ..... V
AgNi+0,2zAu 700VA/...75W 15A(10ms) 20x106/ 105 0,8...1,2UN ON:1,2VA/W; OFF: 0,3VA/W 10/8ms ( >50ms) 24, 48, 115, 230 C9-R21 / AC ..... V 12, 24, 48 C9-R21 / DC ..... V
AC
50/60Hz
Standard
DC
10%
D, DX
= Type X (Option)
DC
10%
5
12
42 32 22
3 7
2 6
1 5
2 6
3 7
4 8
75
30
12 11 10 9 14
0,5 x1,2
Ordering example Relay C9-A41X/AC230V Socket CS-114 (clip incl.) Socket S9-P Retaining clip RC-G (option)
CS -114
14
A2
S9 - P
13
9 10 11 12 13 14
13
A1
0,6
RC-G
1,4
9
11
12 11 10
41 31 21
22,5
12,6
13,2
22,5
18
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
6,35 6,35
4,05
Signal Relay 2x
3,5 Au
Signal Relay 3x
Industrial Relays
1
z z
01
3,5 Au
4
100zA100mV...3A30VD/ 250VA 100zA100mV...3A30VD/ 250VA
2
z
KR23X/DC24V D
KR13X/DC24V D
1
Case
4 2
z
3 1
4
z
3
z
2
8
+
8 6 5
+
7
+
8 6 5 7
+
6
01
+
7
Case
Case
relay
KR 33 X /DC 24 V D
35,5
01
KR13
Miniature Industrial Relay
1- to 3-channel for control and signal circuits Power consumption only 250mW per channel Test voltage: 2000V 1000V Tamb. operation/storage: -20..+60/ - 40..+85C
KR 23
Relay like KR13, but 2-channel
with a width of 11mm per channel this relay is especially space-saving and cost-effective.
KR 33
Relay like KR13, but 3-channel
with a width of 7,3mm per channel this relay is especially space-saving and cost-effective.
and others:
www.comat.ch
Connection No. on socket
MAX MIN
3A
250 V A // 110 V D
3A
250 V A // 110 V D
3A
250 V A // 110 V D
100 A 100mV 4 2 24 23
z
100 A 100mV 4 2 3 1 13 2 14 1 13 1 1 4
2 1
100 A 100mV 4 2 13 2 14
z
2
3 1 14 13
3 14
1
1 14
A2 23 8 6
)
13 A1 5 7
A2 8
2 A1
1 A1
A2 2 A1 8 6
3 A1
1 A1
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr. (AC1) Operation voltage Power consumption per channel Triggering delay / release time
Ag-alloy+3..5 Au 750VA/...90W//3A 30VD 6A(20ms) 20x106/ 105 0,8...1,2UN 350mW 6/4ms (X: 6ms) 12, 24, 48 KR13A / DC ..... V 12, 24, 48 KR13X / DC ..... V
Ag-alloy+3..5 Au 750VA/...90W//3A 30V D 6A(20ms) 20x106/105 0,8...1,2UN 250mW 6/4ms (X: 6ms) 12, 24 KR23A / DC ..... V 12, 24 KR23X / DC ..... V
Ag-alloy+3..5 Au 750VA/...90W//3A 30VD 6A(20ms) 20x106/ 105 0,8...1,2UN 250mW 6/4ms (X: 6ms) 12, 24 KR33A / DC ..... V 12, 24 KR33X / DC ..... V
A X
DC
20%
DC
20%
10
Clip GC-T *)
2 4 6 8 1
B
22 x 65
1 3
2 4 6 8
75
3 5
5 7
R
Clip RC-G Clip GC-W *) 22 x 28
S7- P
CS-18
22,5
5,2
13,1
14,5
Ordering example Relay KR23X/DC24V Socket CS-18 or S7-P Retaining clip RC-G (option)
21 11
22,5
22
35,5
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
19
0,6
Case
0,5 x 2
RC-G
2,2
KAT 2008
30
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
20
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Industrial Relays
Standard Relays
Series
C5-M10
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
21
KAT 2008
Industrial Relays
C2 Standard
Power Relay
Control Relay
AC 230 V A
WH: 35 x 35
DC 24V D
58
C2-A20
2-pole Miniature Industrial Relay according to IEC 67-1
lockable manual operation mechanical flag indicator Test voltage: 2500V 2500V Tamb. operation/storage: -20..+60/ - 40..+85C
C2-T21
Relay like .. A20, but with doubel contacts 6A
The control relay with highest switching reliablility for control and signal circuits ranging from 5mA 5V.
and others:
www.comat.ch
Connection No. on socket
MAX MIN
10 A 250 V A
10mA 10V 6 5 4 3 24 22 12 14
z
6 A 250 V A
5mA 5V 6 5 4 3 24 22 12 14
z
+
A2 21 7 8
)
+
A2 21 7 8 11 A1 1 2
11 A1 1 2
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1) Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / release time
Standard
AgNi 2500VA/...250W 30A(20ms) 20x106/ 5x105 0,8...1,2UN 2,2VA/1,3W 16/8ms 24, 48, 115, 230 X / AC ..... V
AgNi+0,2zAu 1200VA/...150W 15A(20ms) 20x106/ 2x105 0,8...1,2UN 2,2VA/1,3W 16/8ms 24, 48, 115, 230 X / AC ..... V
AC
50/60Hz C2-A20
C2-T21
Standard
DC
10%
12, 24, 48, 110, 125, 220 C2-A20 / DC ..... V 12, 24, 48, 110, 125, 220 C2-A20D X / DC ..... V Option X = with
12, 24, 48, 110, 125, 220 C2-T21 / DC ..... V 12, 24, 48, 110, 125, 220 C2-T21D X / DC ..... V
D, DX
= Type X (option)
DC
10%
5
22
4
12
3
14
EC-8
10 A 400 V
02
62
Clip S3-C
Ordering example Relay C2-A20X/AC230V Socket EC-8 Retaining clip S3-C (option)
A2 21 11 A1
38
22
22
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
AC 230 V A
WH: 35 x 35
DC 24 V D
AC 230 V A
DC 24 V D
58
C3-A30
3-pole Miniature Industrial Relay according to IEC 67-1
lockable manual operation mechanical flag indicator 2500V 2500V Test voltage: Tamb. operation/storage: -40..+60/ - 40..+85C
SEISMIC
APPROV
ED
C3-T31
Relay like .. A30, but with twin contacts 6A
The control relay with highest switching reliablility for control and signal circuits ranging from 5mA 5V.
C3-T32
Relay like .. T31, but with 10 gold plated contacts
The twin contact relay with highest switching reliability for signal circuits ranging from 1mA 5V. Recommend. upto 0,2A 30V.
C3-R20
Remanence Relay 10 A with AC or DC coil
A1(2)=ON; A3(6)=OFF. Minim. triggering time 50ms, permanent triggering admissible. Without option X.
and others:
www.comat.ch
Connection No. on socket
MAX MIN
10 A 250 V A
10mA 10V 9 8 7 5 3 4 34 32 24 22 14 12
z
6 A 250 V A
5mA 5V 9 8 7 5 3 4 34 32 24 22 14 12
z
6 A 250 V A
1mA 5V 9 8 7 5 3 4 34 32 24 22 14 12
z
10 A 250 V A
10mA 10V 9 8 24 22
z
3 4 14 12
A2 31 10 1 1
)
21 1 A1 1 6 1 2
A2 31 10 1 1
21 1 A1 1 6 1 2
A2 31 10 1 1
21 1 A1 1 6 1 2
OFF
A2 21 A3 1 A1 1 10 1 1 6 1 2 AgNi 2500VA/...250W 30A(20ms) 20x106/ 3x105 0,8...1,2UN ON/OFF 1,5/0,5 VA//W 16/10ms ( >50ms) 24, 48, 115, 230 C3-R20 / AC ..... V 12, 24, 48, 110, 125 C3-R20 / DC ..... V
ON
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1) Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / release time
Standard
AgNi 2500VA/...250W 30A(20ms) 20x106/ 5x105 0,8...1,2UN 2,2VA/1,3W 16/8ms 24, 48, 115, 230 X / AC ..... V
AgNi+0,2 z Au 1200VA/...150W 15A(20ms) 20x106/ 2x105 0,8...1,2UN 2,2VA/1,3W 16/8ms 24, 48, 115, 230 X / AC ..... V
AgNi+10z Au 1200VA/...150W 15A(20ms) 20x106/ 2x105 0,8...1,2UN 2,2VA/1,3W 16/8ms 24, 48, 115, 230 X / AC ..... V
AC
50/60Hz C3-A30
C3-T31
C3-T32
Standard
DC
10%
12, 24, 48, 110, 125, 220 C3-A30 / DC ..... V 12, 24, 48, 110, 125, 220 C3-A30D X / DC ..... V Option X = with Types C3-A30 comply to IEE 323 and IEE 344. (seismic qualified)
12, 24, 48, 110, 125, 220 C3-T31 / DC ..... V 12, 24, 48, 110, 125, 220 C3-T31D X / DC ..... V
12, 24, 48, 110, 125, 220 C3-T32 / DC ..... V 12, 24, 48, 110, 125, 220 C3-T32D X / DC ..... V
D, DX
= Type X (option)
DC
10%
9
10A 250VA
8
32
7
24
5
22
3
14
4
12
SWISS
7 8 9
5 3
EC-11
04
75
10 A 400 V
10
2
11 1
10A 400VA
Clip S3-C
C-A2
C11A
30
34
02
9
34
8
32
7
24
5
22
3
14
4
12
CONNECTOR
C-A2
SD -1W
A2
31
21
1 1
A1
A2
31
21
11
A1
10
1 1
10
11
32
Ordering example
Clip S3-C
38
20
38
22
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
23
KAT 2008
Industrial Relays
C3 Standard
1 1
Power Relay
Control Relay
Signal Relay
10 Au
Remanence Relay
AC 230 V A
WH: 35 x 35 50
C4 -A40
4-pole Industrial Relay with faston pins
lockable manual operation mechanical flag indicator Test voltage: 2500V 2500V Tamb. operation/storage: -40..+60/ - 40..+85C
and others:
www.comat.ch
Connection No. on socket
MAX MIN
10 A 250 V A
10mA 10V 1 10 8 7 5 4 1 44 34 24 42 32 2 1 14 12
z
22
+
A1 21 1 1 6 13 3 41 31 12 14 9
)
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1) Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / Release time
Standard
AgNi 2000VA/...250W 30A(20ms) 20x106/ 6x105 0,8...1,2UN 2,4VA/1,4W 20/8ms 24, 48, 115, 230 C4-A40 X / AC ..... V 12, 24, 48, 110, 125, 220 C4-A40 / DC ..... V 12, 24, 48, 110, 125, 220 C4-A40D X / DC ..... V Option X = with
AC
50/60Hz
Standard
DC
10%
D, DX
= Type X (option)
DC
10%
Socket CS-14
11 44 8 34 5 24 2 14 10 42 7 32 4 22 1 12
10 11 9 12 14
7 8
4 5
6 3 13 CS-14
92
14 A2
13 A1
Clip S3-CMG
12 41 9 31 6 21 3 11
38
28
50
24
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
C5 Standard
16 A 400 VA
10 A @ 220 VD
AC 230 V A
WH: 35 x 35
DC 24 V D
50
C5 -A30
3-pole Industrial Relay with faston pins
lockable manual operation mechanical flag indicator Test voltage: 4000V 4000V Tamb. operation/storage: -40..+60/ - 40..+85C
C5 - M10
Highpower Relay, in particular for DC loads upto 10 A 220 V D (DC1)
With 2 contacts in seires and a blow magnet for safe arc extinguishing.
and others:
www.comat.ch
Connection No. on socket
MAX MIN
16 A 500 V A / 6 A AC15
10mA 10V 6 3 5 2 34 24 32 4 1 14 12
z
16 A 500 V A / 6 A AC15
10mA 10V 6 13 4 14
S N
22
+
A2 B A
+
A1
A1 1 1 7 A
31 21 9 B 8
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1) Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / Release time
Standard
AgNi 4000VA/...400W 40A(20ms) 20x106/ 3x105 0,8...1,2UN 2,4VA/1,4W 20/10ms 24, 48, 115, 230, 400*) C5-A30 X / AC ..... V 12, 24, 48, 110, 125, 220 C5-A30 / DC ..... V 12, 24, 48, 110, 125, 220 C5-A30D X / DC ..... V Option X = with
AgNi 4000VA/...880W 40A(20ms) 20x106/ 3x105 0,8...1,2UN 2,4VA/1,3W 20/10ms 24, 48, 115, 230, 400*) C5-M10 X / AC ..... V 12, 24, 48, 110, 125, 220 C5-M10 / DC ..... V 12, 24, 48, 110, 125, 220 C5-M10D X / DC ..... V
AC
50/60Hz
Standard
DC
10%
D, DX
= Type X (option)
DC
10%
Socket CS-15
6 34 3 32 5 24 2 22
CS-15
4 14 1 12
B A2 9 31 8 21
A A1 7 11
80
Clip S3-CMG
38
3,5
26,5
50
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
25
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
26
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Industrial Relays
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
27
KAT 2008
Industrial Relays
Power Relay
Control Relay
THE UN
LOCK LOCK
IN
IBLE ST R U C T DE
ONES
12345
WH: 35 x 35
A1 2 7N A2
RELAY
12345
10 A 400 V AC1 Ag Ni 24 22 14 12 6 5 3 4 8 21 1 11 C21A 5
RELAY A1 2+ 7 A 2 ..D ..L
...L
51
C21
2-pole Industrial Relay according to IEC 67-1
lockable manual operation mechanical flag indicator Test voltage: 2500V 1500V Tamb. operation/storage: -40..+70/ - 40..+85C
C22
Relay like .. C21, but with twin contacts 6A
The control relay with highest switching reliablility for control and signal circuits ranging from 1mA 5V.
and others:
www.comat.ch
Connection No. on socket
MAX MIN
6A 250V A
1mA 5V 6 5 4 3 24 22 12 14
z
+
A2 21 7 8
)
+
A2 21 7 8 11 A1 1 2
11 A1 1 2
Contact material Switching power AC1/ DC1 Peak inrush power Switching cycles mech./electr. (AC1) Operation voltage AC 50 Hz / DC Power consumption Triggering delay / release time
Standard
Ag (AgCuNi) 2500VA/...300W 40A(20ms) 100x106/ 7x105 0,8...1,2/0,8...1,25UN 2,5VA/1,2W 15/d8, a15ms 24, 48, 115, 230 L / AC ..... V
Ag (AgCuNi) 1500VA/...200W 15A(20ms) 100x106/ 1,5x105 0,8...1,2/0,8...1,25UN 2,5VA/1,2W 15/d8, a15ms 24, 48, 115, 230 L / AC ..... V
AC
50/60Hz C21
C22
Standard
DC
10%
12, 24, 48, 110, 220 C21 / DC ..... V 12, 24, 48, 110, 220 C21D L / DC ..... V Option L = with
12, 24, 48, 110, 220 C22 / DC ..... V 12, 24, 48, 110, 220 C22D L / DC ..... V
D, DL
= Type L (option)
DC
10%
5
22
4
12
3
14
EC-8
10 A 400 V
02
62
Clip HF-32
Ordering example Relay C21/AC230V Socket EC-8 Retaining clip HF-32 (option)
A2 21 11 A1
38
22
28
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
THE UN
LOCK LOCK
12345
WH: 35 x 35
A1 2 10 N A2
RELAY
12345
10 A 400 V AC1 Ag Ni 34 32 24 22 14 12 9 8 7 5 3 4 11 31 6 21 1 11 C31A 5
RELAY A1 2+ 10 A 2 ..D ..L
6 A 250 V AC1 Ag Ni 34 32 24 22 14 12 9 8 7 5 3 4 11 31 6 21 1 11
...L
51
C32/DC24VD 480
939
C32D5
C31
3-pole Industrial Relay according to IEC 67-1
lockable manual operation mechanical flag indicator Test voltage: 2500V 1500V Tamb. operation/storage: -40..+70/ - 40..+85C
C32
Relay like .. C31, but with twin contacts 6A
The control relay with highest switching reliablility for control and signal circuits ranging from 1mA 5V.
and others:
www.comat.ch
Connection No. on socket
MAX MIN
6A 250V A
1mA 5V 9 8 7 5 3 4 34 32 24 22 14 12
z
A2 31 10 1 1
)
21 1 A1 1 6 1 2
A2 31 10 1 1
21 1 A1 1 6 1 2
Contact material Switching power AC1/ DC1 Peak inrush power Switching cycles mech./electr. (AC1) Operation voltage AC 50 Hz / DC Power consumption Triggering delay / release time
Standard
Ag (AgCuNi) 2500VA/...300W 40A(20ms) 100x106/ 7x105 0,8...1,2/0,8...1,25UN 2,5VA/1,2W 15/d8, a15ms 24, 48, 115, 230 L / AC ..... V
Ag (AgCuNi) 1500VA/...200W 15A(20ms) 100x106/ 1,5x105 0,8...1,2/0,8...1,25UN 2,5VA/1,2W 15/d8, a15ms 24, 48, 115, 230 L / AC ..... V
AC
50/60Hz C31
C32
Standard
DC
10%
12, 24, 48, 110, 220 C31 L / DC ..... V 12, 24, 48, 110, 220 C31D L / DC ..... V Option L = with
12, 24, 48, 110, 220 C32 / DC ..... V 12, 24, 36, 48, 110, 220 C32D L / DC ..... V
D, DL
= Type L (option)
DC
10%
Railway D/R
DC
10%
The railway-relays C31D/R DC comply to fire protection standards according NFF 16101/2 and ISO 9125/2.
8
32
7
24
5
22
3
14
4
12
10A 250VA
SWISS
7 8 9
5 3
EC-11
04
75
10 A 400 V
10
2
11 1
10A 400VA
Clip HF-32
C-A2
C11A
30
7
24
5
22
3
14
4
12
34
02
CONNECTOR
C-A2
SD -1W
A2
31
21
1 1
A1
A2
31
21
11
A1
10
1 1
10
11
32
Ordering example
Clip HF-32
38
20
38
22
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
29
KAT 2008
Industrial Relays
1 1
Power Relay
Control Relay
IN
CTIBLE D E ST R U
ONES
1 1
Power Relay 2x
Control Relay 2x
8 11
7 6
R2 R1
N 10
3 2 1
8 1 1
7 6
R2 R1
N 10
3 2 1
WH: 35 x 35
10 A 250 V A
5 A 250 V A
51
04
relay
04
10
11+
6+
2+
C 33 / AC 230 V A
relay
C 34 / AC 230 V A
relay
C39 / DC 24 V D
C33
2- and 3-channel Industrial Relays according to IEC 67-1
Single or twin contacts Front contact inspection window or LED display (C39) Test voltage: 2000V 2000V Tamb. operation/storage: -25..+60/ - 40..+85C
C34
Relay like C33, but with twin contacts 5 A
The control relay with highest switching reliablility for control and signal circuits ranging from 1mA 6V. Width per channel: 17,5mm.
C39
Triple-channel Twin Contact Relay 5 A
with 3x1 No contact it is ideal for interface applications ranging from 1mA 100mV. LED display for each channel. Width per channel: 1 1,7mm.
and others:
www.comat.ch
Connection No. on socket
MAX MIN
10 A 250 V A
10mA12V 9 8 75 3 4 1 14 1 12
1
5 A 250 V A
1mA 6V 9 8 75 3 4 1 14 1 12
1
5 A 250 V A
1mA100mV 9 8 7 5 3 4
2 14 2 12
2 14 2 12
3 14 3 13 2 14 2 13 1 14 1 13
A2 21 2 A1 1 10 1 1 6
)
11 1 1
A1 2
A2 21 2 A1 1 10 1 1 6
11 1 1
A1 2
A2 3 A1 10 1 1
A1 1 A1 6 1 2
Contact material Switching power AC1/ DC1 Peak inrush power Switching cycles mech./electr. (AC1) Operation voltage AC 50 Hz / DC Power consumption per channel Triggering delay / release time
AgCdO 2500VA/...300W 40A(16ms) 20x106 / 105 0,8...1,15UN 1,3VA/0,55W 15/25ms 24, 48, 115, 230 C33 / AC ..... V 12, 24, 48, 110 C33 / DC ..... V
AgNi 1250VA/...200W 20A(16ms) 20x106 / 105 0,8...1,15UN 1,3VA/0,55W 15/25ms 24, 48, 115, 230 C34 / AC ..... V 12, 24, 48, 110 C34 / DC ..... V
AC
50/60Hz
DC
C39
10%
8
32
7
24
5
22
3
14
4
12
05
5 A 250 V A
3
14
R3 8
R2 5
R1 4
7
24
5
22
4
12
10A 250VA
SWISS
7 8 9
5 3
EC-11
04
75
10 A 400 V
10
2
11 1
10A 400VA
Clip HF-32
C-A2
C11A
30
34
02
CONNECTOR
C-A2
SD -1W
A2
31
21
1 1
A1
A2
31
21
11
A1
10
1 1
10
11
32
Ordering example
Clip HF-32
38
20
38
22
30
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Industrial Relays
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
On delay
www.comat.ch
S R
Off delay
t
Pulse shaping
S R
Blinker functions S R
S (pulse or continuous contact) R on for t S no influence on R and t
Pulse shaping
t
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
t t t
S R
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
31
KAT 2008
Industrial Relays
1 1
0,2 s - 30 min
0,2-3s/min 2-30s/min
On delay
E
CT2 (8-pin) CT3 (11-pin)
RELAY
413 58 6 19 4 1 3 5 6 7 81
t
S R on with delay S OFF R off
S R
RELAY
Off delay
A
41 3 567 8 11 9 413 586 CT2 7 A2 7 Socket 2 A1 2 S B1 CT3 10 A2 10 < A1 2 S B1
S R
Socket
www.comat.ch
MAX
10A 250 V A
UC180-265V UC90-265V UC90-150V DC9,5-18V UC20-65V
Order no.
Pulse shaping
Function Triggering
2 = 8 - pole 3 =11- pole CT .. - E 30 / ... CT .. - A 30 / ... W CT .. - K 30 / ... CT.. -W30 / ... CT .. - B 30 / ...
S R
E
A2 A1 A2 B1 A1 A2 B1 A1 +
S S S
H U M U M H H
L L L L L
S S
A K
UC
AC/DC
DC
10%
t t t
S R
ON
OFF
Industrial relay
CT2 / 3
Socket
EC-8
02
EC-11
5
22
6
24
4
12
3
14
9
34
8
32
7
24
5
22
3
14
4
12
02
Ordering example Time cubes CT2-E30/H Socket EC-8 or CS-8 Relay C2-... Time cubes CT3-E30/H Sockel EC-11 oder C11A Relay C3-...
S3-CT
For Relay C2...C3
EC-8
10 A 400 V
EC-11
10 A 400 V
Clip
62
HF-33
For Relay* C21...C39
A2
21
11
A1
A2
31
21
11
A1
10
11
58 ( 51* )
25
22
38
38
32
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
32
30
10
10
R-module
2
15k 1N4007 1000 V 1A
1
A1
Module section
A2 12
RDL1 / DC 48VD
Relay coil
/
RL1/ UC12-24 V u
10 A2
6k8
Illuminated displays
2 A1
see RL1/UC...V
A1
With additional diode output (12), e.g. for collective alarm messages.
Suppressing units
see RC1/UC...V
2 A1
2 12 A1
2 12 A1
RC1/ UC 12- 48 V u
10 A2
47E 0,47F
2 A1
RCL1/ UC 24 V u
10 A2
47E 0,47F 10k
RDL1/ DC12-24 V d
2 A1 10 A2
6k8
RDL2 / DC12-24 V d
2 A1 10 A2
6k8
RDL3 / DC12-24 V d
10 A2
6k8
2 A1
2 12 A1
2 12 A1
RCL1/ UC 48 V u
10 A2
47E 0,47F 22k
RDL1/ DC 48 V d
2 A1 10 A2
15k
2 A1
/
N L N( )
(+) L
+ +
8
32
7
24
5
22
3
14
9
34
8
32
7
24
5
22
3
14
4
12
12345
10 A 250 VA
12345
10 A 250 VA
SWISS
7 8 9
SWISS
5 4 3
04
7 8 9
5 4 3
Clip S3-C 75 Plugged-in neutral conductor connector C-A2 (C11A standard delivery). Module section
05
10
2
11 1
10 A 400 V A
10
2
11 1
C11A
C 12 B
10 A 400 V A
C-A2
CONNECTOR
C-A2
CONNECTOR
C-A2
Ordering example
Module section Module section
A1 A2 31 21
Module RCL1/UC48V Socket C11A Relay Type C3-... Clip S3-C (option)
A2
31
21
11 1
11 B1 1 12
A1
10
11
10
11
38
38
20
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
33
KAT 2008
Industrial Relays
1 1
Plug-in coil wirings for 3-pole Industrial Relays C3, C31 and C30
Relay modules indicate the relays switch mode and /or help limiting cutoff voltage peaks in the control circuit by means of a diode or a RC module. The types R..2/3 are equipped with additional diodes for signal or OR-circuits. For parallel or serial connections the relay modules are simply plugged info the sockets C11A or C12B.
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
34
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Industrial Relays
DIN Relays
Stepping switch
C103.06
C203.06
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
35
KAT 2008
Industrial Relays
Control Relay 2x / 3x
Signal Relay
T BASE
13 mm
CR16 AX CR16 CX
DIN Interface Relais
No external coil wiring required Mounting on DIN rail TS 35 Test voltage: 2000V 2000V
CR 23 A
CR 33 A
CR11C
Signal Relay
13mm series,1 channel, 2 x CO Au twin contact. Recommended max. load 200mA/24V, resistiv. Integrated LED and coil wiring.
CRS1C
Stepping Relay
13mm series, 1 x CO suitable for permanent energizing. Supply loss safe. Integrated LED and coil wiring.
Power Relay
13mm series, 1 x NO resp. 1 x CO up to 6A. Integrated LED and coil wiring.
and others:
www.comat.ch
MAX MIN
6 A 250 V A
10mA 12V
13 14 14 12 11 12
3 A 250 V A
100 A 100mV
1
1A 250 V A
100 A 10mV
13 3 14 1 14 2 14
12 14
11
6 A 250 V A
10 mA 12 V
14 12 11 12
13 14
13 14
22 24
21
Connection
(DC-version)
(DC-version)
+
A2 A1
+
A2 A1
+
1 A1
+
2 A1
+
1 A1
+
11 A2 21 + A1
(DC-version)
A2
A2
2 A1 A2 3 A1
+
A2 A1
01
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1) Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / release time
AgNi 1500VA/...180W 15A/20ms 30x10 6 / 1,5x10 5 AC 20%+10%/DC 15% 2,5VA/0,25W 10ms /20ms 24 CR16AX CR16CX / DC..... V 230 CR16AX CR16CX / AC ..... V
Ag-alloy/Au3 m 750VA/...90W 20x10 6 / 1,5x10 5 /DC 20% 0,25W 6ms /4ms 24 CR 23A CR33A / DC..... V
Ag-alloy/Au5 m 65VA/...30W 200x10 6 / 10 5 /DC 25% 0,25W 3ms /4ms 24 CR11C / DC ..... V
DC
10%
AC
50/60Hz
BS13-K BS13-G
(incl. paper)
13
44
11
90
36
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
45
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
2x
Control Relays 2x 3x
Signal Relays 2x
Industrial Relays
C203.04 C301.04
Control Relay
High efficient 2/3 channel control relay DIN series 17,5mm, each 1 x CO resp. 1 x NO twin contact. Multi-layer contact up to 5A. Very versatile in application. Integrated LED and coil wiring.
C103.06 C203.06
Signal Relay
DIN series 17,5mm, 1/2 channel each 1 x CO Au twin contact. Recommended max. load 200mA/24V. Integrated LED and coil wiring.
Power Relay
DIN series 17,5mm, 1/2 channels with 1/2 x CO contacts up to 6A. Integrated LED and coil wiring.
and others:
www.comat.ch
MAX MIN
6 A 250 V A
10 mA 24 V A1 A2 A1 A2 A1 A1 A2
5 A 250 V A
1mA 0,1V A1 A1 A2 A2 A2 A2
2 A 125 V A
10 A 10mV A1 A2 A1 A1 A2
1 2 Connection 1
z = contact opening < 3mm
1 2 1
11 12 14
A1 A1 A1
1 2 1
11 12 14
1 2
11 12 14
11 12 14
14 14 14
2
11 12 14
Data at Tamb. =20C
2
11 12 14 13 13 13 11 12 14
2
11 12 14
21 22 24
11 12 14
Contact material Switching load AC1/DC1 Peak inrush power Switching cycles mech./electr.(AC1) Operation voltage AC50Hz/DC Power consumption AC/DC Triggering delay / release time
AgNi 1500VA/...300W 15A/20ms 20 x10 6 / 10 5 0,85...1,15UN 0,6W 1,7W 10ms /10ms C103.01 C133.01 2x 0,6W 12 C203.01 / DC ..... V 110-127, 220-240 C203.01 / AC ..... V 24, 36, 48 C203.01 / UC ..... V
Ag-alloy 1250VA/...150W 10A /20ms 50 x10 6 / 1,5 x10 5 0,8...1,2UN 0,25W (per channel) 6ms /30ms 12-15, 24, 48 C203.04 C301.04 / DC ..... V
Ag-alloy/Au3 m 250VA/...60W 100 x10 6 / 10 5 0,8...1,2UN 0,25W (per channel) 10ms /20ms C103.06 12 C203.06 / DC ..... V 110-127, 220-240 C203.06 / AC ..... V 24, 36, 48 C203.06 / UC ..... V
DC
10%
AC
50/60Hz C103.01 C133.01
C103.06
UC
/
C103.01
C133.01
C103.06
C103
LABEL
Ordering example
C103
Relay C301.04/DC24V
4,2
2,5
75
17,5
64
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
37
KAT 2008
Notes
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
38
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Industrial Relays
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
39
KAT 2008
Industrial Relays
C35...C38 Solid-State
1 1
DC Solid-State Relay 1x
DC Solid-State Relay 2x
3 4 0,8 A 265 VU
K
9 0,8 A 265 V A
DC10-32 Vd
+ RL 7 5 3
DC10-32 Vd + RL 9 PNP
K
RL 7 5 3 R1
WH: 35 x 35
R2
R1
PNP
5A
2A
R2
51
05
C35
1- and 2-channel Solid-state Relay according IEC67-1
LED display for each channel operation voltage range 0,8..1,1UN galvanically decoupled control (2kV) Tamb. operation/storage: -25..+60/ - 40..+85C
C36
AC Solid-State Relay double-channel
Triac output, crossover switching. Built-in RC wiring protection. Especially for bulb-loads and high switching frequencies. Minimum load: 30mA
C37
DC Solid-State single-channel
Bounce-free and non wearing for DC loads (inductive/ capacitive). Short-circuit/overload proof. No external wiring protection required.
C38
DC Solid-State Relay double-channel
Construction, characteristics and application like C37, but double-channel. 2A constant current per channel.
and others:
www.comat.ch
MAX MIN
5 A 10 ... 32 V D
1mA 5V
2 A 10 ... 32 V D
1mA 5V
+
Connection No. on socket Designation according to DIN/EN 5001 1
RL
4
L
2
RL
RL
RL
RL 7 5 3
1 14
+
1
+
7 5 3
14
13
9 14
2
3 14
1
4 13
+ 13 14
2kV
9 14
2kV
+ 13
1
2kV
2kV
2kV
+ A1
2
+
1+2
+
A2 10
2
+
1 A1
A2 10
A1 6
1 A1 1 A1
A2
10
A1
2
A1 A2 6 1
Peak inrush power Voltage drop Residual current Short-circuit proof K Control voltage Frequency range Control current Triggering delay Off delay
1,5A /1s 3V 100 A 12A /200 s 110-240V 50..60Hz 35mA 20ms 80ms 24-48V 40..400Hz 20mA 20ms 80ms
8A /20ms 1,5V 3mA 110-240V 50..60Hz 17mA 30ms 40ms 24V 50..60Hz 12mA 30ms 80ms
15A /1s 0,2V 100 A 70A /150 s 110-240V 40..60Hz 5mA 30ms 30ms 24-48V 40..400Hz 6mA 20ms 30ms
15A /1s 0,2V 100 A 70A /150 s 110-240V 40..60Hz 5mA 30ms 30ms 24-48V 40..400Hz 6mA 20ms 30ms
AC
50/60Hz
110-240 C36 / AC ..... V 24 C36 / UC ..... V 24-48, 110-240 C37 / UC ..... V 24-48, 110-240 C38 / UC ..... V
UC
/
8
32
7
24
5
22
3
14
4
12
7
24
5
22
3
14
4
12
10A 250VA
SWISS
7 8 9
5 3
EC-11
04
75
10 A 400 V
10
2
11 1
10A 400VA
Clip HF-32
C-A2
C11A
30
34
02
CONNECTOR
C-A2
SD -1W
A2
31
21
1 1
A1
A2
31
21
11
A1
10
1 1
10
11
32
Ordering example
Clip HF-32
38
20
38
22
40
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
05
Solid-State
10 N
Solid-State
10 N
04
04
Solid-State
10
2+
Solid-State
10
6+
2+
01
30 mA ..1,5A AC 20-265 V A
30 mA ..0,8 A AC 20-265 V A
3
L1
4
L1
3
L1
01
TATE SOLID - S
1
Case
KA108 /DC12-24 V D
relay
L1
2 kV
2 kV
2 kV
+
8 7 8
+
6 5
+
7
35,5
+
8
01
Case
relay
KA115 / UC12- 24 V U
Case
relay
KA 208 / DC12- 24 V D
KA108
AC Solid-State Relay
1- and 2-channel crossover switching each channel indicated by LED Triggering/Output 2kV Tamb. operation/storage: -25..+60/ - 40..+85C
KA115
Universal AC Solid-State Relay
1-channel, 1,5A/AC240V. Triac output with RC wiring protection. Triggering galvanically isolated.
KA208
Universal AC Solid-State Relay
2-channel, 0,8A/AC240V (2x0,5A). Triac outputs RC wiring protection. Width per channel: 11mm. Triggering galvanically isolated.
and others:
www.comat.ch
Connection No. on socket
MAX MIN
0,8 A
30mA
3
20 ... 265 V A
1,5 A
30mA
3
20 ... 265 V A
0,8 A
30mA 4 14
20 ... 265 V A
14
13
14
13
2 3 13 1 14
1 13
2kV
2kV
2kV 1
2kV
+ A1 7
A2
8
+ A1 7
+
A2 8
2
+
1 A1
A1 A2 6 5
Peak inrush power Residual current Frequency range Voltage drop Control voltage Triggering OFF Switching delay Control current
20A (20ms) 3mA 50/60Hz 1,5V UC10...30Vu U A1: 6V 12ms 10mA (24V)
8A (20ms) 3mA 50/60Hz 1,5V DC10...30Vd U A1: 6V 12ms 10mA (24V) KA208/DC12-24V
DC
20% KA108/DC12-24V
UC
A40-400 Hz /
KA115/UC12-24V
10
Clip GC-T *)
2 4 6 8 1
B
22 x 65
1 3
2 4 6 8
75
3 5
5 7
R
Clip RC-G Clip GC-W *) 22 x 28
S7- P
CS-18
22,5
5,2
13,1
14,5
Ordering example Relay KA115/UC12-24V Socket CS-18 or S7-P Retaining clip RC-W (option)
21 11
22,5
22
35,5
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
41
0,6
Case
0,5 x 2
RC-G
2,2
KAT 2008
30
Industrial Relays
KA Solid-State
AC Solid-State Relay 1x
AC Solid-State Relay 1x
AC Solid-State Relay 2x
KD Solid-State
DC Solid-State Relay 1x
DC Solid-State Relay 2x
DC Solid-State Relay 3x
+
PNP K 2,5 / 2 x1,5 A PNP K 2,5 A
RL
RL
3
5k
1
5k
KD125 /DC12-24 V D
relay
KD 215 / DC12-24 V D
relay
RL
RL
1
5k
8 2
6 + 5 + 7 3 1
5k
8
02
+
7
Case
8
01
+
6 7
Case
relay
KD 315 / DC12- 24 V D
01
Case
35,5
KD125
AC Solid-State Relay
1- and 3-channel overload/short-circuit proof K limiting inductive voltage each channel indicated by LED Triggering/Output 2kV Tamb. operation/storage: -25..+60/-40..+85C
KD215
Solid-State Relay like KD125, but 2-channel
2,5A/2x1,5A/DC24V. Width per channel: 11mm. With thermal overload protection and short-circuit resistent.
KD315
Solid-State Relay like KD125, but 3-channel
2,5A/3x1,5A/DC24V. Width per channel: 7,3mm. With thermal overload protection and short-circuit resistent.
and others:
www.comat.ch
Connection No. on socket
MAX MIN
2,5 A 10 ... 32 V D
1mA 5V 4 3 1 13
K
1,5 A 10 ... 32 V D
1mA 5V 4 2 14 2 13 1 13
1,5 A 10 ... 32 V D
1mA 5V 4 2 14 2 13 3 13 1 13
+ 14
2
5k
1
5k
2
2
1 A1
3
5k
2
1
5k
3
A1 7
A2 8
A1 6
A2 8
A1 6
A1 5
1 A1
Output Current peak Residual current ON-resistance Control voltage Triggering OFF ON-OFF-switching delay Control current
1PNP (noc) 15A (20ms) <100 A 50m DC 5...18V/10...32Vd U A1-2: 3V/ 6V 2,5ms 4mA (24V) 20% 6-12, 12-24 KD125 / DC ..... V
2x1PNP (noc) 15A (20ms) <100 A 50m DC 10...32Vd U A1-2: 3V/ 6V 2,5ms 4mA (24V) KD215/DC12-24V
3x1PNP (noc) 15A (20ms) <100 A 50m DC 10...32Vd U A1-2: 3V/ 6V 2,5ms 4mA (24V) KD315/DC12-24V
DC
10
Clip GC-T *)
2 4 6 8 1
B
22 x 65
1 3
2 4 6 8
75
3 5
5 7
R
Clip RC-G Clip GC-W *) 22 x 28
S7- P
CS-18
22,5
5,2
13,1
14,5
Ordering example Relay KD215/DC12-24V Socket CS-18 or S7-P Retaining clip RC-G (option)
21 11
22,5
22
35,5
42
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
0,6
Case
0,5 x 2
RC-G
2,2
30
3A,12-24VD
2
Q2 Q3
3
Q1
WH: 22 x 65
E1
+
7
1
Case
01
35,5
relay
KDM3-24/DC12-24VD
KDM 3-24
Motor Control Relay
For controlling and braking of DC Motors Tamb. operation/storage: -25..+60/-40..+85C
Interface Module
for PLCs and control systems with one PNP power contact and one NPN brake contact. For DC motor controls with brake function. The contacts are overload- and short circuit protected.
and others:
www.comat.ch
Connection No. on socket
MAX MIN
3 A (5A) 24V d
10mA 10V 4 2 3 1 Q2 Q3 Q1
K
+
4 8 2 6 3 1 7
S
M
K
8
Data at Tamb. =20C
E1 + 7
3A,12-24VD
Contact type Switching current/voltage Switching power DC1 Peak inrush current Contact resistance Leakage current Trigg. delay/release time Operation voltage active Power consumption Pmax
Power contact FET PNP 3A (5A) / 10-32V ...100W 20A / 1s <100m <100A <1ms 9-28V 400mW / DC24V 20% KDM3-24/DC12-24V
Break contact FET NPN 3A (5A) / 10-32V ...100W 20A / 1s <100m <100A <1ms
DC
Clip GC-T *)
2 4 6 1
1 3
2 4 6 8
4
3 5
0,5 x 2
75
5 7
65
S7- P
Ordering example Interface module KD215/DC12-24V Socket CS-18 or S7-P Retaining clip RC-G (option)
CS-18
22,5
5,2
13,1
14,5
Clip GC-W *)
21 11
22,5
22
35,5
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
43
0,6
RC-G
2,2
KAT 2008
30
Industrial Relays
KDM3-24 Solid-State
1x co
+ Q1 Q2
01
+
3 A, 12-24 VD K
Q1
Q2
(+)
()
A1
A2
A1 A2
KDW 3-24
Solid-State AC/DC Relay
Change over PNP for all inductive loads Mounting onto DIN rail TS 35. Test voltage: 2kV Tamb. operation/storage: -25..+60/-40..+85C
Interface Module
Solidstate relay with 1x CO output PNP for 3A, 24VD. The contacts are overload- and short circuit protected K . LED status display. Galvanical isolated output. This relay is specially recommended as an alternative to electromechanical relays for applications with high switching cycles. Bounce-free switching.
and others:
www.comat.ch
MAX MIN
3 A (5A) 24V d
10mA 10V
+
K
Q1
Q2
+
K
Connection
Q1 Q2
R L2
R L1
A1 A2
A1
Data at Tamp = 20C
A2
Contact type Switching current / voltage Switching power DC1 Peak inrush current Contact resistance Leakage current Trigg. delay / release time Operation voltage active Power consumption Pmax
FET PNP 3A (5A) / 10-32V ...72W (160W) 20A / 20ms <50m <100A <5ms 18-255V AC/DC 3-8mA / <400mW KDW3-24/UC24-240V
UC
50/60 Hz /
LABEL
2,5
TS 35
75
17,5
64
44
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
1
I-0 = 2 kV
CTV11
1- and 3-channel DC Solid-State Relay
for high switching cycles galvanical separation 2kV mounting onto DIN rail TS 35 Tamb. operation/storage: -25..+60/-40..+85C
C301.08
Compact 3-channel Solid-State Relay
for the switching of DC loads up to 2A/DC 24 V. Outputs, galvanically isolated. Overload and short-circuit proof. Specially suitable for high switching cycles. (PLC and ancillery)
C311.08
Compact 3-channel Solid-State Relay
like C301.08 but without galvanic isolation of outputs.
Solid-State Relay
with galvanically isolated triggering input to control and switch DC loads. 1 channel 250mA/DC5-60V
and others:
www.comat.ch
MAX MIN
250 mA 5 ... 60 VD
1mA 10V
12-65V 4-18V
2 A 10 ... 30 VD
1mA 10V
2 A 10 ... 30 VD
1mA 10V
+ EH
+ EL
A2
A2
A2
A2
+ 1A1 + 2 A1 + 3 A1
2kV
+ 1A1 + 2 A1 + 3 A1
1 2 3
5k
Connection
PNP K
250mA
3
2kV
+
5-65V
O
RL
1O
2O
3O
1O
2O
3O
Admissible peak current Residual current Voltage drop / ON-rheostat Control voltage (U nom) Ripple Triggering OUT Control current on A1 Swtiching delay
0,75A (20ms) <100zA <1V EH 15-60V / EL 5-15V 10% @10V EL 2,5V / EH 5V Typ. 10mA ON 200zs / OFF 400zs
15A (20ms) <100zA 50m DC24V (10...30V)D 10% @10V U A1: 6V 4mA @ 24V 2,5ms C301.08/DC24V
15A (20ms) <100zA 50m DC24V (10...30V)D 10% @10V UA1: 6V 4mA @ 24V 2,5ms C311.08/DC24V
DC
10% CTV11/DC5-60V
CTV11
LABEL
75
2s
t on t off
Ordering example Solid-state relay C301.08/DC24V
4,2 2,5
Steady load
CTV11
17,5 5 64
10
50
t on 100 (%)
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
45
KAT 2008
Industrial Relays
DIN
Pulse Shaper
2x
CPF11
Pulse shaper with timing function
To stretch respective to limit control pulses. Suitable for NAMUR sensors respective to analyze fast sequences with high revolutions and short pulses. Tamb. operation/storage: -25..+60/-40..+85C
CPF22
Double Channel Pulse Shaper
Input /output galvanically isolated 4kV Input and output times separately settable 2 functions to choose LED output display for each channel Settable functions:
K L A
Settable times: input pulse output pulse
K A
Settable times: input pulse output pulse
1/ 5 ms
and others:
5 600 ms
www.comat.ch
MAX MIN
2 A 15... 32 V d
2mA 10V
1532VD
150 mA 45 V d
2mA 10V
NAMUR sensor
1928V
Three-wire sensor
1532V
+ +
PNP
1532VD 1S 2S
E1 E2
4K7 4kV
+
S NAMUR
E2
+
S PNP E1
3K3
11K 5K6
E1 CPF
150mA
PNP
2O
CPF
FD
+
+
1045VD
1O
0,8A
1RL
2RL
RL
DC
10% CPF11/DC24V CPF22/DC24V
Pulse shaping
L
S R
Off delay
S R
S R
CPF11
CPF22
TS 35
75
8 5 64 10
17,5
46
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
Industrial Relays
Miniature Contactors
Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page:
www.comat.ch
&
&
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
47
KAT 2008
Industrial Relays
Miniature Contactor
RC Modules
1 L1
13
3 L2
23
5 L3
33
13 NO
A1
53 NO 63 NO 73 NO 83 NO 53 NO 63 NO 71NC 81NC 51NC 61NC 71NC 81NC
43
E0414 01
SOC-6-1a/AC230V
ON 1
20A 400Va
50/60 Hz
01 01 01
SS-1BM / UC12-48 VU
O
5
10A 400Va
13
A1
54 NO 64 NO 74 NO
SU-440M
SU-422M
SU-404M
84 NO
54 NO
64 NO
72 NC
82 NC
52 NC
62 NC
72 NC
82 NC
047 150
2 T1
14
4 T2
24
44 34 6 T3 14 NO
A2
SOC-6 -1a
3-/4-pole Miniature Contactor
All contacts with twin interruption Manual operation Mechanical status display 4000V 4000V Test voltage: Tamb. operation/ storage: -20..+60/ - 40..+85C
SU-440M
Additional auxiliary contact block
4 NO contacts. Snap-on to miniature contactor SOC-6. Expands the SOC-6 up to a total of 8 NO contacts.
SU-422M
Additional auxiliary contact block
2 NO + 2 NC contacts. Snap-on to miniature contactor SOC-6. Expands the SOC-6 up to a total of 6 NO and 2 NC contacts.
SU-404M
Additional auxiliary contact block
4 NC contacts. Snap-on to miniature contactor SOC-6. Expands the SOC-6 up to a total of 4 NO and 4 NC contacts.
SS-1...
RC Modul
to limit overvoltage. Universal version (UC...V U) for AC and DC coils. Snap-on directly onto miniature contactor SOC-6.
and others:
www.comat.ch
Continuous terminal No.
MAX MIN
20 A // 10 A 400 V A
10mA 24V // 1mA 6V 1 3 5 13 A1+ L1 L2 L3 NO 13 23 33 43
10 A 400 V A
10mA 24V
10 A 400 V A
10mA 24V
10 A 400 V A
10mA 24V
53
NO
63
NO
73
NO
83
NO
53
NO
63
NO
71
NC
81
NC
51
NC
61
NC
71
NC
81
NC
Connection lay out (top/bottom) 14 24 34 44 T1 T2 T3 NO 2 4 6 14 A2 AgNi 11kW 400V // 4kW 400V 4kW 9A 400V // 1,9A 400V // 1,5A 400V ...300W 0,3A 220V // 0,1A 220V 90A / 70A eff 20x106 0,8...1,2UN 4,2VA/3W 20ms/15ms 24, 230 SOC-6-1a / AC ..... V 24 SOC-6-1a / DC ..... V
NO NO NO NO NO NO NC NC NC NC NC NC
A1
01
A2
54
64
74
84
54
64
72
82
52
62
72
82
Contact material Switching power AC1 Switching power AC 3/4 Switching current AC15 Switching power DC1 Switching power DC13 Making-/Breaking capacity Mechanical switching cycles Operation voltage AC 50 Hz / DC Power consumption Typical make/release time
AgNi 7kW 400V 1,9A 400V ...300W 0,3A 220V >30A 10x106
AgNi 7kW 400V 1,9A 400V ...300W 0,3A 220V >30A 10x106
AgNi 7kW 400V 1,9A 400V ...300W 0,3A 220V >30A 10x106
Current consumption: at AC24V : 8mA at DC24V : 4mA at AC230V : 12mA at DC220V: 2,5mA Release time SOC-6 with RC module 45ms
AC
50Hz
SU-440M
SU-422M
SU-404M
DC
10%
Interlocking unit
SR-6
SR-6
O
Interlock Unit
01
Arrangement
SR-6 SS-1...
TS35 45,4
13
23
33
43
SOC-6
SU-4...
50
58
SOC-6
A2
2 T1
4 T2
6 T3
14 NO
26,2
35 44
53 57
48
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
1
SOC-2-1a /AC230VA
13
1
50Hz
3
SOC-2-1a /AC230VA
13
SOC-2-1a/AC230VA
AC1 20A 400V/13kW AC3 2,2kW/400V AC1 20A 400V/13kW AC3 2,2kW/400V
IEC/EN 60947-4
02
A1 A2
AC1 20A 400VIEC/EN 13KW 02 60947-4 AC3 2,2kW 400V A1 EN 60947-4; IEC1095; VDE 0660 50Hz
I
50Hz
13
O A1
A2
L1 T1
L2 T2
L3 T3
RE CO MINIATU
NTACTO
14
14
A2 14
02
SOC-2-1a
3- + 1-pol. Miniature Contactor
All contacts with twin interruption Manual operation Mechanical status display Test voltage: 4000V 4000V
Installation Contactor
High power relay up to 3x20A 400V and 1 auxiliary twin contact 6A. For installation mounting with cover conform DIN 43880. The cover can be sealed. For general applications and motors up to 2,2kW. Suitable for pilot control signals.
and others:
www.comat.ch
Continuous terminal No.
MAX MIN
20 A // 6 A 400 V A
10mA 24V // 1mA 6V A1 1 3 5 13 L1 L2 L3 NO 13 23 33 43
Connection lay out (top/bottom) 14 24 34 44 T1 T2 T3 NO 2 4 6 14 A2 AgNi 13kW 400V 2,2kW 400V 20A 24V / 2A 110V 100A / 2,5ms 6A 400V 6A 24V / 0,5A 220V > 3 x 10 6 0,8 - 1,2 U N 32W 20ms /1,5 W < 20ms / < 20ms 24, 230 SOC-2-1a/AC.....V
Contact material Switching power AC1 Switching power AC3/4 Switching current DC1 Inrush current Switching current Switching current DC1 Mechanical life time Coil voltage Coil power Typical make / release time
AC
50Hz
50
Ordering example
SOC-2
4,5 35
TS35
62,5
45 50.5
1 8
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
49
KAT 2008
Contactor 20 A
2NO or 2NC or 1NO/1NC
Contactor 25 A
4NO or 4NC or 2NO/2NC
Contactor 40 A
4NO or 4NC or 2NO/2NC
Contactor 63 A
4NO or 2NO/2NC
AUX Block
2NO or 2NC or 1NO/1NC
NO NOI
SE!
TS 35
RIC 20
AC/DC Istallation Contactors No noise!
All contacts doublemake/ doublebrake Mechanical status display Test voltage: 4kV/3 Tamb. operation/storage: -20..+55/ - 30..+80C MAX MIN
RIC 25
Contactor 25 A
Contactor with 4NO or 4NC or 2NO+2NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional.
RIC 40
Contactor 40 A
Contactor with 4NO or 4NC or 2NO+2NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional.
RIC 63
Contactor 63 A
Contactor with 4NO or 2NO+2NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional.
RIC-AUX
Auxilary
Contactblock with 2NO or 2NC or 1NO+1NC contacts. For signalling and control applications up to 6 A with crown twin contacts. For all RIC contactors.
Contactor 20 A
Contactor with 2NO or 2NC or 1NO+1NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional.
and others:
20 A 400 V A
10mA 24V 1 A1 3
25 A 400 V A
10mA 24V 1 3 A1 5 7
40 A 400 V A
10mA 24V 1 3 A1 5 7
63 A 400 V A
10mA 24V 1 3 A1 5 7
6 A 400 V A
5mA 24V 51 61
www.comat.ch
2 R1
A2 A1
R2 R3
R2
A2 A1
R4
R2
A2 A1
R4
R2
A2
R4
52
62
R1 R3
R5 R7
R1 R3
R5 R7
51 61
R2
Data at Tamb =20C
A2
R4
R2 R4
A2
R6
R8
R2 R4
A2
R6
R8 AgSnO2 63A 400V 8,5kW/230V 40kW/400V 120 1x105 0,85 - 1,1 U N 5W 20ms // 35ms 24, 230 RIC63-400/UC ..... V 24, 230 RIC63-220/UC ..... V
Contact material Switching current I TH Switching voltage Switching power AC3 Switching power AC1/AC7a Op Frequenz max. cycle/hr Electrical life cycles AC1 Coil voltage range Power consumption Operate / release time typ.
AgNi 20A 400V 1,3kW/230V 4kW/230V 600 2x105 0,85 - 1,1 U N 2,5W 20ms // 20ms 24, 230 RIC20-200/UC ..... V 24, 230 RIC20-110/UC ..... V 24, 230 RIC20-020/UC ..... V
AgNi 25A 400V 2,2kW/400V 16kW/400V 600 2x105 0,85 - 1,1 U N 3W 10ms // 50ms 24, 230 RIC25-400/UC ..... V 24, 230 RIC25-220/UC ..... V 24, 230 RIC25-040/UC ..... V
AgSnO2 40A 400V 5,5kW/400V 26kW/400V 120 1x105 0,85 - 1,1 U N 5W 20ms // 35ms 24, 230 RIC40-400/UC ..... V 24, 230 RIC40-220/UC ..... V 24, 230 RIC40-040/UC ..... V
UC
A 50/60 Hz / D
RIC-AUX20
UC
A 50/60 Hz / D
RIC-AUX11
UC
A 50/60 Hz / D
RIC20 RIC25-63
RIC-AUX02
Ordering example Installation contactor RIC25-400/UC230V Aux block RIC-AUX20 Sealing cover RIC-SEAL20
RIC20
RIC25
TS35
85
RIC-AUX
50
KAT 2008
This edition replaces all previous issues. Availability, errors and specication subject to change without notice.
COMAT AG BERNSTRASSE 4 CH-3076 WORB SCHWEIZ www.comat.ch Tel. +41 (0)31 838 55 77 Fax. +41 (0)31 838 55 99 info@comat.ch
45
RIC40 RIC63