You are on page 1of 40

JC International Limited RC.

413243
CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15122

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

3.1/2 REG BOX x 3.1/2 IF PIN XOVER


82

034205509

3.1/2 REG

6.1/4

5.3/16

11/16

4.1/16

N/A

N/A

N/A

9.15/1 6

3.1/2 IF OK 6.1/4 1.1/2 5.15/16 N/A N/A 4 N/A 7.3/16 OK

ACC
2.43

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15123

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

LIFT SUB
83

4.1/2 IF N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6.11/16 2.1/4 6.3/16 N/A N/A 4.3/8 N/A 9.5/8 OK

ACC
2.64

AM061

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15124

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

TEST CUP
84

4.1/2 IF 4.1/2 IF 6.1/4 6.3/16 5/8 5.5/16 N/A N/A N/A 7.1/16 OK 6.3/16 2.19/32 6 N/A N/A 4.3/8 N/A 8.1/4 OK

ACC
2.05

7891.78

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15125

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

XOVER SUB
85

6.5/8 REG 4.1/2 IF 6.3/4 6.5/16 5/8 5.5/16 8.1/8 4.5/8 N/A 17.5/8 OK 7.3/4 2.13/16 7.11/16 5.3/8 1 5 N/A 12.1/4 OK

ACC
2.60

JC11

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15126

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

XOVER SUB
86

4.1/2 IF 4 IF 6.5/8 6.1/8 5/8 4.15/16 8.1/2 4.1/16 N/A 10.5/8 OK 6.5/8 2.7/8 6.3/16 4.3/4 3/4 4.1/2 N/A 6.3/16 OK

ACC
2.57

JC12

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15127

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

4.1/2 IF PIN x BOX SUB


87

4.1/2 IF 4.1/2 IF 6.3/16 6.1/8 5/8 4.5/16 N/A N/A N/A N/A OK 6.3/16 2.13/16 6.1/8 N/A N/A 4.3/8 N/A N/A OK

ACC
2.26

11205

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15128

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

4.1/2 IF PIN x BOX SUB


88

4.1/2 IF 4.1/2 IF 6.3/16 6.1/8 11/16 5.5/16 N/A N/A N/A N/A OK 6.3/16 1.11/16 6.1/8 N/A N/A 4.3/8 N/A N/A OK

ACC
2.14

INT002

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15129

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

JUNK SUB
89

4.1/2 REG 4.1/2 REG 6.7/8 5.3/4 11/16 4.3/4 N/A N/A N/A 7.1/4 OK 5.7/16 2.3/8 5.1/4 N/A N/A 4.3/16 N/A 5.1/2 OK

ACC
2.14

INT007

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15130

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

LIFT SUB
90

3.1/2 IF N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 4.3/4 2.1/4 4.5/8 3.1/2 3/4 3.3/8 N/A 7.5/8 OK

ACC
2.56

AM045

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15131

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

PIW SUB
91

4.1/2 IF 4.1/2 IF 6.5/8 6.1/8 5/8 5.5/16 N/A N/A N/A N/A OK 6.5/8 3.1/16 6.1/16

115096

4.11/1 6

ACC
1 4.1/2 N/A N/A OK 1.50

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15132

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

GRAY VALVE
92

4.1/2 IF 4.1/2 IF 6.5/8 6.1/8 5/8 5.5/16 N/A N/A N/A N/A OK 6.5/8 2.1/4 6.1/8 N/A N/A 4.3/8 N/A N/A OK

ACC
2.30

JC04

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15133

W.O.NO.
DATE: 08/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

6.5/8FH PIN x 6.5/8 REG PIN XOVER


93

6.5/8 FH

ACC
8.1/2 2.13/16 7.25/32 5.3/8 3/4 4.15/16 N/A N/A OK 3.05

MF-X6-609

PIN

PIN
6.5/8 REG

ACC
8.1/2 2.13/16 7.3/4 N/A N/A 4.15/16 N/A N/A OK

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15134

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

XOVER SUB
94

6.5/8 REG 4 IF 6.1/2 6.1/8 11/16 4.15/16 8.1/4 4.3/8 N/A 16.1/2 OK 8.3/16 2.7/8 7.3/4

6533

5.11/3 2

ACC
3/4 4.15/16 N/A 9 OK 2.27

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15135

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

LIFT SUB
95

4.1/2 IF N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6.3/4 2.1/4 6.5/16 N/A N/A N/A N/A 9.7/8 OK

ACC
2.70

INT022

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15136

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

LIFT SUB
96

4.1/2 IF N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6.5/8 2.1/4 6.11/32 N/A N/A N/A N/A 9.9/16 OK

ACC
2.63

AM055

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15137

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

3.1/2IF PIN x BOX SUB


97

3.1/2 IF 3.1/2 IF 4.11/16 4.5/8 5/8 4.1/16 N/A N/A N/A N/A OK 4.11/16 2 4.19/32 N/A N/A 3.15/16 N/A N/A OK

ACC
2.67

JC05

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15138

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

3.1/2 IF BOX x 3.1/2 IF PIN X-OVER


98

AM053

3.1/2 IF

4.25/32

11/16

4.1/16

N/A

N/A

N/A

22.1/1 6

3.1/2 IF OK 4.5/8 2.3/8 4.1/2 N/A N/A 3.7/8 N/A 8 OK

ACC
2.20

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15139

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

4.1/2 IF BOX x 4.1/2 IF PIN X-OVER


99

AM050

4.1/2 IF

6.5/8

6.3/8

3/8

5.3/8

N/A

N/A

N/A

21.1/1 2

4.1/2 IF OK 6.3/32 2.15/16 6 N/A N/A 4.3/8 N/A 8.5/32 OK

ACC
2.85

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15140

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

LIFT SUB
100

4.1/2 IF N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6.21/32 2.1/4 6.11/32 N/A N/A 4.3/8 N/A 9.3/8 OK

ACC
2.62

AM040

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15141

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

LIFT SUB
101

3.1/2 IF N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 4.3/4 2.11/32 4.5/8 N/A N/A 4 N/A 9.3/16 OK

ACC
2.70

AM066

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15142

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

3.12 IF BOX x 3.1/2 IF PIN XOVER


102

3.1/2 IF 3.1/2 IF 4.3/4 4.5/8 5/8 4.5/16 N/A N/A N/A N/A OK 4.11/16 2 4.5/8 N/A N/A 4 N/A N/A OK

ACC
2.67

JC06

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15143

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

3.1/2 IF PIN x 3.1/2 REG BOX X-OVER


103

ACC
3.1/2 IF 4.3/4 4.19/32 3/4 4.1/16 N/A N/A N/A N/A OK

AM052

BOX

BOX
ACC

3.00

3.1/2 REG

4.3/4

4.3/8

23/32

3.9/16

11.1/2

N/A

N/A

OK

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15144

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

LIFT SUB
104

3.1/2 IF N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 4.3/4 2.9/32 4.5/8 N/A N/A 3.7/8 N/A 7.7/8 OK

ACC
2.55

AM043

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15145

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

LIFT SUB
105

4.1/2 IF N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6.23/32 2.3/8 6.5/16 N/A N/A 4.3/8 N/A 9.5/8 OK

ACC
2.64

AM058

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15146

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

STABILIZER
106

4.1/2 IF 4.1/2 IF 6.1/2 6.1/8 23/32 5.5/16 8.1/4 4.5/8 N/A 33 N/A 6.1/2 2.13/16 6.1/4

3185

4.23/3 2 23/32

ACC
4.1/2 N/A 17.7/16 OK 6.04

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15147

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

LIFT SUB
107

3.1/2 IF N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 4.3/4 2.1/8 4.5/8 N/A N/A 3.7/16 N/A 7.7/8 OK

ACC
2.70

AM026

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15148

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

MILLING SUB
108

4.1/2 IF N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 5.23/32 2.1/4 5.1/2 N/A N/A 4.1/8 N/A 9 OK

ACC
1.86

IN25-119

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15149

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

SIDE ENTRY SUB


109

3.1/2 IF 3.1/2 IF 4.23/32 N/A 5/8 4.1/8 N/A N/A N/A N/A OK 4.23/32 2.5/16 4.5/8 N/A N/A 3.7/8 N/A N/A OK

ACC
1.60

18083

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15150

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

LIFT SUB
110

4.1/2 IF N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6.5/8 2.3/4 6.1/8 N/A N/A 4.3/8 N/A 9.1/16 OK

ACC
0.85

89109

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15151

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

X-OVER
111

NC 35 4.1/2 IF 6.1/2 N/A 5/8 5.5/16 N/A N/A N/A N/A OK 6.1/2 2.5/16 5.3/16 N/A N/A 4 N/A N/A OK

ACC
0.70

INT 008

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15152

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

X-OVER
112

2.7/8 EUE 3.1/2 IF 4.23/32 4.11/16 9/16 4.1/16 N/A N/A N/A N/A OK 4.23/32 2.3/8 N/A N/A N/A N/A N/A N/A OK

ACC
1.00

JC07

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15153

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

X-OVER
113

SPEC 4.1/2 IF 6.15/32 6.1/8 5/8 5.5/16 N/A N/A N/A N/A OK 6.15/32 2.7/8 N/A N/A N/A N/A N/A N/A OK

ACC
0.92

JC 08

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15154

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

CROSS OVER
114

4.1/2 IF

ACC
6.5/16 2.7/8 6.1/8 N/A N/A 4.7/8 N/A N/A OK 1.43

7891:07

PIN

PIN
SPEC

ACC
6.5/16 N/A N/A N/A N/A N/A N/A N/A OK

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15155

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

X-OVER
115

SPEC SPEC 3.5/8 N/A N/A N/A N/A N/A N/A N/A OK 3.3/8 3 N/A N/A N/A N/A N/A N/A OK

ACC

JC 09

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15156

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

MILLING SUB
116

2.7/8 REG N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 4.1/4 4.7/16 4.3/16 N/A N/A 3.13/16 N/A N/A OK

ACC
1.01

SX 1201

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15157

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

X-OVER
117

2.7/8 EUE 2.7/8 EUE N/A N/A N/A N/A N/A N/A N/A N/A OK N/A 2.1/4 N/A N/A N/A N/A N/A N/A OK

ACC
1.35

JC 10

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15158

W.O.NO.
DATE: 12/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

X-OVER
118

2.7/8 EUE 2.7/8 EUE 3.5/8 N/A N/A N/A N/A N/A N/A N/A OK 3.5/8 N/A N/A N/A N/A N/A N/A N/A OK

ACC
2.85

JC 11

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15159

W.O.NO.
DATE: 13/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

LIFT SUB
119

3.1/2 IF N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 4.3/4 2.1/4 4.5/8 N/A N/A 3.29/32 N/A 8 OK

ACC
2.57

AM 047

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15160

W.O.NO.
DATE: 13/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

CASING SCRAPPER
120

4.1/2 REG 4.1/2 REG 5.11/16 5.3/8 5/8 4.21/32 N/A N/A N/A 9.1/4 OK 5.11/16 2.1/4 5.3/8 N/A N/A 4.1/4 N/A 9.5/8 OK

ACC
3.43

JC 16

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member

JC International Limited RC. 413243


CUSTOMER: OANDO ENERGY SERVICES

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

DRILLING TOOLS & SUBS INSPECTION REPORT


ROTARY SHOULDER CONNECTIONS

RIG: INTEGRITY

LOCATION: OGBAINBIRI
REPORT NO.

P.O.NO.
15161

W.O.NO.
DATE: 13/02/2013

INSPECTION PROGRAM:

VISUAL BODY, VISUAL CONNECTIONS, BLACK LIGHT CONNECTIONS, DIMENSIONAL 3


SPECIFICATION: DS-1 STANDARD. CAT. 3-5 CATEGORY 1 2 3-5 HDLS MPI on Critical Area ALL DIMENSIONS IN INCHES

S/N

ID. NO

DESCRIPTION

Conn. Type

OD

Bevel Dia.

BOX TOOL JOINT Counterbore Boreback/Floatbore Depth Dia Length Dia.

Lead Gauge

Tong Space

Cond.

Conn. Type

OD

ID

PIN TOOL JOINT SRG Bevel Dia Width Dia.

Conn. Length

Pin Nose

Tong Space

Cond.

Length (Ft.)

REMARK

CROSS OVER
121

5.1/2 FH

ACC
7.25/32 2.13/16 7.5/16 N/A N/A 5 N/A 4.1/4 OK 0.91

6187-IV

PIN

PIN
6.5/8 FH

ACC
9.7/16 2.13/16 8.7/16 N/A N/A 5.1/4 N/A 4.29/32 OK

Max Reqd. Min Reqd.

SD = Seal Damaged TD = Thread Damaged BB = Belled out Box ST = Streched Threads GT = Galled Threads

CRK = Crack WO = Wash Out PS = Pitted Seal PT = Pitted Threads CT = Corroded threads

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED

1 0 0

COMMENTS:

FIT FOR USE AS AT THE TIME OF INSPECTION

LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTHS INSPECTED

0 1

CUSTOMER SIGNATURE:..

DATE:

INSPECTOR:

NNANNA COLUMBUS
ASNT LEVEL II

Member