You are on page 1of 1

JC International Limited RC.

413243
CUSTOMER: P.O. NO.: SIZE 5.7/8 GRADE S-135 WEIGHT 26.7 CATEGORY 1 SEADRILL

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com LOCATION: JC INTERNATIONAL BASE RIG: WEST CAPELLA JOB NO.

DRILL PIPE INSPECTION TALLY SHEET


W.O. No.:22502067/22500465 DATE: 18/02/2012
RANGE 3 COATED YES N0 WORN TALLY Lead Gauge Tong Space MPI/UT
FINAL CLASS

REPORT No.:2681
NOM. WALL THICKNESS 0.415 2 3 4 BOX TOOL JOINT Min OD HB OD COND. Bevel Dia Counterbore Depth Dia. Seal Width Lead Gauge Tong
MPI/UT

TOOLJOINT 7'' VAM EIS 5 HDLS HARDBANDED ?

SPECIFICATION: API RP 7G 2 + VAM SPEC PIPE BODY ID No. OD Wear


Corrosion

YES PIN TOOL JOINT

Int.Coat Cond.

Gouge Slip Cuts

C on d.

Int.

Ext.

Wall Thick.

Space

Upset

Dia

Width

Length

Length

C on d.

ID

OD

Bevel

Seal

Neck

CONN

Length
Ft.

REMARK

B en t EM I

Upset

1 2

ACC ACC

0.425 0.425

YES

7 7

7.3/16 7.3/16

YES

6.23/3 21/32 2 6.23/3 21/32 2

5.7/8 5.7/8

3/8 3/8

0.002 0.002

12.3/8 12.1/2

GT ACC

YES YES

3.3/4 3.3/4

7 7

6.23/3 2 6.23/3 2

3/8 3/8

3/8 3/8

0.002 0.002

10 7

ACC GT

YES YES

P P

42.22 44.16

RECUT BOX RECUT PIN

Max. Reqd. Min. Reqd.

Joint with Pin for Repair Joint with Box for Repair Joint with Pin & Box for Repair Pin Refaced / Rebeveled Box Refaced / Rebeveled Bent Pipes

1 1 0 0 0 0

REMARK

PREMIUM CLASS 2 SCRAP TOTAL

SD = Seal Damage TD = Thread Damage BB = Belled Box ST = Streched Thread PT = Pitted Thread PS = Pitted Seal GT = Galled Thread W = Wash ID

CLASSIFICATION

CRK = Crack STJ = Short Tool Joint HBD = Hard Band Damage RF = Refaced ACC = Acceptable REJ = Rejected NA = Not Applicable

Inspector : SIMON OGBAN

Qualification ASNT LEVEL II

Sign Date

18/02/2012

Member

You might also like