Professional Documents
Culture Documents
Analogue comparator 0 - 10 V
9
GND Error
2
0-10 V Analog Comparator
8
LEVEL1 +24V GND LEVEL2 +10V GND
6 7 5
1 2 3 4 5 6 7 8 9
Digital outputs Display of output error Potentiometer LEVEL2 (upper threshold) Analogue input Reference voltage linear displacement sensor Display of external operating voltage External operating voltage Potentiometer LEVEL1 (lower threshold) Display of switching status of the outputs
AIn
Subject to change
1/2
526214
Analogue comparator 0 - 10 V
Design
The comparator is mounted onto top-hat rails. The electrical connection is effected by means of screw terminals. The comparator converts the analogue output signal of the linear displacement sensor in a digital output signal. 3 digital outputs are available: 1: Measured value lower than threshold 1 2: Measured value between threshold 1 and threshold 2 3: Measured value higher than threshold 2 The thresholds are adjustable by means of two potentiometers LEVEL1 and LEVEL2. The active output is displayed by a LED.
Function
Digital outputs
Level 1
Level 2
+10 V
Technical data
Electrical Operating voltage Current consumption Switching outputs Maximum switching current Output URef Analogue input Hysteresis UHyst. Degree of protection Elektrical connection 20 28 V DC up to 200 mA 3, PNP, normally open 50 mA per channel 10 V DC (max. 50 mA) 0 10 V 80 mV IP 20 Screw terminals for cable with max. 0.75 mm
2/2
Subject to change