You are on page 1of 1

Compressor Calculations

Units Fluid Volumetric Flow Suction Temperature Discharge Temperature Suction Pressure Discharge Pressure Pressure Ratio Molecular Weight Universal Gas Constant per Mol wt Compressibility Factor Adiabatic Exponent(Cp/Cv) (n-1)/n=(k-1)/kp V T1 T2 P1 P2 Pr Mw R/Mw Z k Kg/kmol J/Kg-K KNm /hr Kg/sec C C bar a bar a
3

Air 8.00 2.87 35.00 150.00 1.05 9.00 8.57 28.95 287.18 1.00 1.40 0.15

Polytropic Calculation
Effeciency Head Power Outlet Temperature(Calculated) p Ha Pa T2 m kW C 193.47 223639.80 331.78 150.00

Adiabatic Calculation
Effeciency Head Power Outlet Temperature(Calculated) a Ha Pa T2 226.99 262376.35 331.78 296.03

m kW C