You are on page 1of 1

Doc. No.

: 09012001

White Max. 4 mm Red Red 40 mm max.

Extention leads teflon over teflon insulated silver plated copper wires 24/7/32 AWG terminated on Bootlace ferrules (Standard lead length is 1000 mm +25 mm )

RTD Sensor S-02

These sensors are tested for : 1) Dimensions 2) Calibration at 50OC, 100 OC & at 180 OC 3) Dielectric Strength : 2KV rms for 1 min. Pt-100 Temperature - resistance characteristic
Temp. Deg. C. Resistance Ohms
R

Pt - 100

Red

-25.00 90.15

0.00 100.00

50.00 119.40

Red
(IEC-60751)

Pt-100 element inside heat shrink sleeve

White

100.00 138.50

150.00 157.31

200.00 175.84

PECON
electronics

RTD Sensor S-02


Title

Note : 1) RTD Sensor S-02 is suitable over -50 to +200 OC temperature range 2) Sensor S-02 is Class B (IEC-60751) permissible error OC = [ 0.3 + (.005 x t) ] where t is the temperature in OC. 3) Longer lead lengths are available for specific needs.

Power Electronics & Control


Ahmedabad

Date 20/01/ 2009

Scale NTS

Drg. no.

PEC/09012001