You are on page 1of 22

Warning

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

PCG0558

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorized parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
For any inquiries, contact your local distributor.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose an
outdoor unit with anti-corrosion treatment.
The air conditioners manufactured
by Daikin Industries have
received ISO 9001 certification for
quality assurance.
Certificate Number. JMI-0107
JQA-0495
JQA-1452

All Daikin Industries locations


and subsidiaries in Japan have
received environmental
management system standard
ISO 14001 certification.
Daikin Industries, Ltd.
Domestic Group
Certificate Number. EC99J2044

Dealer

About ISO 14001


ISO 14001 is the standard defined by the
International Organization for Standardization (ISO)
relating to environmental management systems.
Our group has been acknowledged by an
internationally accredited compliance organisation
as having an appropriate programme of
environmental protection procedures and activities
to meet the requirements of ISO 14001.

Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global/
c All rights reserved
Printed in Japan 10/05/003 Y.K.

The specifications, designs, and information in this brochure are subject to change without notice.

AIR CONDITIONERS
LINE UP
Split
SkyAir
VRV
Packaged Air Conditioners

DAIKIN AS A GLOBAL CORPORATE CITIZEN


Examples of installation

Ministry of Agriculture &


Fisheries Laboratory
Oman
April 2002
7 VRV Plus

Contents

Al Nokhba Tower
(Elite Residential Suites)
Kuwait
June 2003
11 VRV Plus

S P L I T T y pe A i r C o n di t i o n e r s

7
Sanabel Tower Hotel
Saudi Arabia
January 2001
75 VRV Plus
Air Cooled Split Type Air Conditioners

Osaka Head Office

Awqaf Tower
Qatar
June 2004
8 VRV Plus

Tokyo Head Office

Osaka Head Office

Production Site

Tokyo Head Office

Overseas Affiliate

Production Site

Sales Agent

Overseas Affiliate

21
The Intelligent Air Conditioning System

Sales Agent

28.....HRV
29.....Control Systems

ASIA/OCEANIA

CHINA

EUROPE

33

Reliability derived from 80 years of achievement

Daikin Europe N.V.

Daikin Industries
Czech Republic

Daikin Airconditioning
UK

Shanghai Daikin Airconditioning

X'ian Daikin Qing'an


Compressor

Huizhou Daikin Suns


Airconditioning

Since it's foundation in 1924, Daikin Industries, Ltd. has constantly been
developing to become a global leader in an array of fields, such as air
conditioning systems, refrigerants, fluorochemicals, electronics and hydraulic
machineries. In particular, Daikin holds the largest market share of both
residential- and commercial-use air conditioning systems in Japan. It is
the world's sole manufacturer that combines research, development and
manufacturing of air conditioning systems, refrigerants and compressors.

Daikin Industries (Thailand)

Daikin Airconditioning
Singapore

PACKAGED
AIR CONDITIONERS
42.....Water Chillers

Daikin Australia

JAPAN
U.S.A.
Daikin Airconditioning
France

Daikin Airconditioning
Spain

Daikin Airconditioning
Germany

Daikin Airconditioning
Italy

Daikin Fluoro Coatings


(Shanghai)

Daikin (China) Investment

Kanaoka Factory,
Sakai Plant

Shiga Plant

Yodogawa Plant

Rinkai Factory,
Sakai Plant

Kashima Factory

Daikin (China) Investment Daikin (China) Investment


Shanghai Branch
Guangzhou Branch
Daikin America

Daikin Industries Head Office

SPLIT Type Air Conditioners

Note: Availability of the products shown in this catalog varies by country.

Line up
Type

Split type air conditioners


Wall-mounted type...............................5

The Split System is the ideal air conditioning solution for one room or
an area of your home. Daikin air conditioners lead the industry with
their energy savings. Each indoor unit features silent operation
function, bringing comfort in your living room or bedroom.
Daikin now has a new D series. The simple and stylish design softly
harmonizes with your living space.

RT
Btu
kcal
kW

Model Name

Wallmounted
type

FT-D

C/O 60 Hz

FT-GA

C/O 60 Hz

FT-GA

C/O 50 Hz

Capacity class
1.42
17,100
4,300
5.0

1.72
20,500
5,160
6.0

FTY-GA H/P 60 Hz

Function list
Function

Wall-mounted type
FT60D
FT50/60GA FTY50/60GA

Power-airflow dual flaps


Power airflow flap
Comfortable
airflow

W I DE
ANGLE

Wide-angle louvers
Vertical auto-swing
Horizontal auto-swing

AUT O

Comfort
control
operation

Auto fan speed


Program dry function
Automatic operation

Lifestyle
convenience

N EW

New powerful operation


Indoor unit On/Off switch
Air-purifying filter
Air-purifying filter with photocatalytic deodorizing function
Wipe-Clean flat panel

Healthy &
clean

Mold-proof air filter


Washable grille
C L E AN Filter cleaning indicator
24

24-hour On/Off timer

Timer
Night set mode
Auto-restart after power failure
Worry free

SELF

Self-diagnosis digital display


Anticorrosion treatment of outdoor heat exchanger fin

SPLIT Type Air Conditioners

Wall-mounted type
FT-D Series

FT(Y)-GA Series

5.06.0 kW

Affordable Comfort You deserve

5.06.0 kW

Comfortable

Brand-New Sleek Flat Panel Design

Unique features such as our Vertical auto-swing and Horizontal auto-swing


will keep your home wrapped in a cloud of air-conditioned comfort.

Compact and Stylish Design

Compact and quiet


The rounded contours of the compact, lightweight indoor unit allow it to
harmonize smoothly with your interior decor, and an improved fan design
makes operating noise hardly noticeable.

Energy-saving
Using your air conditioner for extended periods of time is now a completely
affordable luxury thanks to Daikins advanced energy-saving technology.

The compact and stylish design of Daikin units


harmonizes with any interior decor. The innovative
flat panel of the new D series enhances this effect
and also ensures optimum operation.

Heating

Cooling

The flap descends to blow


warm air directly down
to the floor to quickly warm
the whole room.

The flap flattens out so that


cool air slides off to reach
the farthest corners of the
room.

Outdoor Unit

Indoor Unit

Wireless
remote controller

Wipe-Clean
Flat Panel
FT(Y)50/60GA

High Energy Savings


Daikin air conditioners advanced technology allows them
to achieve significant energy savings with a COP of 2.55
even during periods of extended use.

Air-Purifying Filter with Photocatalytic Deodorizing Function is


able to remove both bacteria and viruses, in addition to
eliminating mold and odors. It can be used for approximately
3 years with appropriate maintenance.

Outdoor Unit

Indoor Unit

Indoor unit

FT50GAVEA

Outdoor unit

R50GV1K

Cooling capacity
*1 (1)/(2)

Power comsumption (220-240 V) *1 (1)/(2)


COP (220-240 V) *1 (2)
Operation range(Outdoor unit)
FT60D

FT60GAVEA
R60GV1K

R60D

Cooling Only (60 Hz)


Indoor unit

FT60DVMK

Outdoor unit

R60DVLK

Power comsumption *1 (1)/(2)


COP *1 (1)
Operation range (Outdoor unit)

CDB

Cooling capacity
*1 (2)/(3)

1 phase, 220 V, 60 Hz
1.96/1.59
23,500/19,100
5,900/4,800
6.9/5.6
2.71/3.10
2.55
19.4 to 54

Notes : *1:Nominal cooling capacities are based on the following conditions:


(1) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB. Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB. Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

1.83/1.82
22,000/21,800
5,540/5,500
6.44/6.40
2.42/2.41-2.51/2.50
2.66-2.56

CDB

19.4 to 54

Cooling Only (60 Hz)


Model

*1 (1)/(2)

1.52/1.51
18,200/18,100
4,590/4,560
5.34/5.30
2.01/2.00-2.19/2.18
2.65-2.43

RT
Btu/h
kcal/h
kW
kW

Heat Pump (60 Hz)

Indoor unit

FT50GAVAL

FT60GAVAL

FTY50GAVAL

FTY60GAVAL

Outdoor unit

R50GVAL

R60GVAL

RY50GVAL

RY60GVAL

Power Supply

RT
Btu/h
kcal/h
kW
kW

RY60G

1 phase, 220-240 V, 50 Hz

Power Supply

Cooling capacity

RY50G

Cooling Only (50 Hz)


Model

Power Supply

R60G

Wireless
remote controller
FT50/60GA

Model

R50G

Healthy and Clean

Heating capacity
*2(1)/(2)

Conversion rates

RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW

1.59/1.28
19,100/15,400
4,800/3,900
5.6/4.5

2.18/2.50

2.57

1 phase, 220 V, 60 Hz
1.93/1.59
23,200/19,100
5,850/4,800
6.8/5.6

2.68/3.06

2.54

1.65/1.42
19,800/17,100
4,990/4,300
5.8/5.0
1.79/1.71
21,500/20,500
5,420/5,200
6.3/6.0
2.00/2.30
1.87/1.85
2.90
3.37

Cooling*1 (2)/(3)
Heating*2 (1)/(2)
Cooling *1 (2)
COP
Heating *2 (2)
19.4 to 54
19.4 to 54
Operation range Cooling
CDB
(Outdoor unit)

-10 to 15
Heating
CWB
Notes: *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27CDB, 19.5CWB, Outdoor temperature: 35CDB. Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB. Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB. Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
*2:Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB. Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21CDB, Outdoor temperature: 7CDB, 6CWB. Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

Power comsumption

kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

1 phase, 220 V, 60 Hz

1.85/1.59
22,200/19,100
5,590/4,800
6.5/5.6
2.04/2.02
24,500/24,200
6,180/6,100
7.19/7.10
2.61/2.97
2.44/2.46
2.49
2.95

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

Air Cooled Split Type Air Conditioners

Note: Availability of the products shown in this catalog varies by country.

Type

Capacity

Line Up
Model Name

RT

1.6

1.9

2.3

3.2

4.1

4.5

6.8

8.3

13.6

16.6

Btu

19100

23200

27600

38900

48800

53900

81900

99600

163400

199300

kW

5.6

6.8

8.1

11.4

14.3

15.8

24.0

29.2

47.9

58.4

2.5

10

15

20

HP
FHC

Ceiling
mounted
cassette type

Indoor units.....................................10

60 Hz

FHYC

H/P

FH

C/O

FHY

H/P

60 Hz

FHK

C/O

50 Hz

Ceiling
mounted
built-in type

FHB

C/O

50 Hz

FHYB

H/P

60 Hz

Wall mounted
type

FA

C/O

FAY

H/P

FV

C/O

FVY

H/P

Ceiling
suspended type

Ceiling mounted
cassette corner
type

Floor standing
type

Packaged air conditioners

Stores often feature the latest in designed decor. This refined beauty attracts
people.
Meanwhile, offices have a functional beauty. This encourages those within to
work hard and apply intelligence and passion to their tasks.
In either situation, a certain elegance should fill the space because thinking
minds require high quality air conditioning. SkyAir by Daikin ensures a
comfortable indoor environment. All over the world, stores, offices, and homes
prefer the low operating noise, attractive design, complete comfort control,
and other benefits brought by SkyAir.

C/O

FH(Y)C

Specifications..................................11
Simultaneous operation system......16

50 Hz

FDBG

Duct
connection
low static
pressure
type

FDB
FDYB

60 Hz
50 Hz
60 Hz

50 Hz
60 Hz
60 Hz
50 Hz
60 Hz
60 Hz
50 Hz

C/O

60 Hz

H/P

60 Hz
50 Hz

FDMG

Duct
connection
middle static
pressure
type

50 Hz

C/O

60 Hz

FD(Y)M

50 Hz

H/P

Duct
connection
high static
pressure
type

FD

C/O

FDY

H/P

60 Hz
50 Hz
60 Hz
50 Hz
60 Hz

Operation system

Applicable Models

Capacity

Simultaneous operation system


RT

4.5

6.3

7.6

Btu

53900

75700

90800

kW

15.8

22.2

26.6

10

HP
50 Hz
C/O
Indoor unit

Indoor unit

60 Hz

Twin

50 Hz
Outdoor
unit

H/P

50 Hz

Indoor unit

Triple

60 Hz

*1

C/O
60 Hz

Indoor unit
Indoor unit

Outdoor
unit

*2

50 Hz
H/P
60 Hz

*2

50 Hz

Indoor unit

Double
Twin

C/O
60 Hz

Indoor unit
Indoor unit
Indoor unit

Outdoor
unit

50 Hz
H/P
*1

60 Hz

Notes: Specifications for RT, Btu and kW are based on the following conditions; Power supply: 60 Hz; Cooling: Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 35.0CDB.

The values given for 2 HP to 6 HP are for the FHY(C) model and 8 HP to 20 HP are for the FD model. The values given for simultaneous operation system are for the FHYC model.
*1:FDYB and FDYM model operate for 2025 (kW) class.
*2:FDYB and FDYM model operate for 20 (kW) class.

Air Cooled Split Type Air Conditioners

Indoor units
Ceiling Mounted Built-in Type

Ceiling Mounted Cassette Type


Quiet,decor-blending form and easy
installation in new or old buildings.
Multiple unit installations maintain a
physical uniformity that is
aesthetically pleasing and make it
easier to plan ceiling lighting
systems and to design interiors.

With the use of simple ducts,


discharge outlets can be located
in a multitude of ways. Top priority
given to interior decor, built-in
type units realize ideal air current
distribution.
FH(Y)B

FH(Y)C

Ceiling Suspended Type

Wall Mounted Type


Wall mounted type units feature
the lowest sound levels in the
industry and greatly upgraded
comfort, thanks to the high fan
speed mode.

On-ceiling installation leaves floor


space unhindered. Extremely
quiet operation enhances the
store's customer service.
FH(Y)

FA(Y)

Ceiling Mounted Cassette Corner Type


Uni-directional discharge outlet is
perfect for corner installation.
A thin, 21.5 cm main body
enables installation even in a
small ceiling overhead space.

Floor Standing Type

Floor standing type units are easy to


install and maintain; their slimness is
suitable for installation in high-ceiling
stores and offices.
FHK
FV(Y)

Packaged Air Conditioners Duct Connection Series


Low static pressure

Middle static pressure

High static pressure

FDMG
FDB(G)
FDYB

FD(Y)M

FD(Y)
For details, please refer to P33-P40.

Outdoor Unit

R emote C ontroller

LCD Wireless
LCD Wired
Remote Controller Remote Controller

10

Air Cooled Split Type Air ConditionersSpecifications


(For specifications of duct connection series, please refer to P35-P40.)

C ooling Only (50 Hz)

Ceiling mounted cassette type


Indoor unit
Model

Outdoor unit

Wall mounted type


50

60

71

100

125

FHC50KVE

FHC60KVE

FHC71KVE

FHC100KVE

FHC125KVE

R71FUV1

R100FUV1

R71FUY1

R100FUY1

R60GV1K

R50GV1

Power supply

R125FUY1

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V,50 Hz/Y1: 3 phase, 380-415 V,50 Hz
kW
RT

1.5/1.5

1.8/1.8

2.2/2.2

3.0/3.0

Cooling capacity

Btu/h

18,200/18,100

22,000/21,800

26,600/26,300

36,200/35,800

44,400/43,700

*1 (1)/(2)

kcal/h

4,590/4,560

5,540/5,500

6,700/6,600

9,100/9,000

11,200/11,000

Power comsumption *1 (1)/(2)

7.80/7.7

10.6/10.5

2.55/2.53

10.6/10.5

13.0/12.8

3.69/3.65

4.39/4.35

Power comsumption *1 (1)/(2)

2.87/2.88

2.96/2.94

COP *1 (1)/(2)

3.6/3.56

3.06/3.04

2.94/2.95

CDB

Operation range (Outdoor temp.)

21 to 52

Floor standing type


50

60

71

100

125

FH50BVE

FH60BVE

FH71BVE

FH100BVE

FH125BVE

R71FUV1

R100FUV1

R71FUY1

R100FUY1

R50GV1

R60GV1K

R125FUY1

RT

1.5/1.4

1.9/1.8

2.2/2.2

3.0/3.0

Btu/h

17,700/17,400

22,500/22,200

26,600/26,300

36,200/35,800

44,400/43,700

kcal/h

4,460/4,400

5,690/5,600

6,700/6,600

9,100/9,000

11,200/11,000

Power comsumption *1 (1)/(2)

3.7/3.6

36,200/35,800

44,400/43,700

6,700/6,600

9,100/9,000

11,200/11,000

kW

7.8/7.7

10.6/10.5

13.0/12.8

2.58/2.56

3.79/3.75

4.67/4.63

Power comsumption *1 (1)/(2)

3.02/3.01

2.80/2.80

2.78/2.76

COP *1

7.80/7.7

kW

10.6/10.5

2.67/2.65

13.0/12.8

3.76/3.74

2.92/2.91

(1)/(2)

Operation range (Outdoor temp.)

4.49/4.45

2.82/2.81

CDB

2.9/2.88

21 to 52

Notes : *1:Nominal cooling capacities are based on the following conditions:


(1) Return air temperature: 27CDB, 19.5CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)

45

60

Indoor unit

FHK45FV1

FHK60FV1

Outdoor unit

R50GV1

R60GV1K

Power supply

C ooling Only (60 Hz)

1 phase, 220-240 V, 50 Hz
RT

1.5/1.4

1.9/1.8

Cooling capacity

Btu/h

17,700/17,400

22,500/22,200

*1 (1)/(2)

kcal/h

4,460/4,400

5,690/5,600

kW

5.19/5.1

6.6/6.5

kW

2.25/2.24

2.76/2.74

2.31/2.28
CDB

Ceiling mounted cassette type

Model

2.39/2.37

45

60

Indoor unit

FHB45FV1

FHB60FV1

Outdoor unit

R50GV1

R60GV1K

Power supply

60
FHC60KVE

71
FHC71KVE

100
FHC100KVE

125
FHC125KVE

125
FHYC125KVE

140
FHYC140KVE

Outdoor unit

R50GVAL

R60GVAL

R71FUVAL

R100FUVAL

R125FUTAL

R125KUYALK

R140KUTALK
R140KUYALK

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz

Cooling capacity

Btu/h

17,700/17,400

22,500/22,200

*1 (1)/(2)

kcal/h

4,500/4,400

5,700/5,600

kW

5.19/5.1

6.6/6.5

kW

2.33/2.32

2.78/2.76

2.23/2.20

2.37/2.36

RT

1.6/1.3

1.9/1.6

2.3/1.9

3.2/2.6

Cooling capacity

Btu/h

19,100/15,400

23,200/19,100

27,600/22,900

38,900/30,700

48,800/42,700

48,800/42,700

53,900/47,800

*1 (1)/(2)

kcal/h

4,800/3,900

5,800/4,800

7,000/5,800

9,800/7,700

12,300/10,800

12,300/10,800

13,600/12,000

Power comsumption *1 (1)/(2)


Operation range (Outdoor temp.)

1.9/1.8

4.1/3.6

4.1/3.6

kW

5.6/4.5

6.8/5.6

8.1/6.7

11.4/9.0

14.3/12.5

14.3/12.5

15.8/14.0

kW

2.21/2.5

2.73/3.14

3.34/4.2

4.54/5.80

6.08/7.00

5.50/6.80

5.70/

2.53

2.49

2.43

2.51

2.35

2.60

CDB

19.4 to 54

2.77

21 to 54

Ceiling suspended type


50
Model

71

100

125

FH50BVE

FH60BVE

FH71BVE

FH100BVE

FH125BVE

R50GVAL

R60GVAL

R71FUVAL

R100FUVAL

R125FUTAL

Power supply

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz

RT

1.5/1.3

1.8/1.6

2.3/1.9

3.2/2.6

4.1/3.6

Cooling capacity

Btu/h

17,900/15,400

22,200/19,100

27,600/22,900

38,900/30,700

48,800/42,700

*1 (1)/(2)

kcal/h

4,500/3,900

5,600/4,800

7,000/5,800

9,800/7,700

12,300/10,800

kW

5.25/4.5

6.5/5.6

8.1/6.7

11.4/9.0

14.3/12.5

kW

2.3/2.5

2.84/3.2

3.44/4.2

4.67/5.80

6.25/7.00

2.28

2.29

2.35

2.44

2.29

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

60

Indoor unit
Outdoor unit

Power comsumption *1 (1)/(2)


COP *1 (1)
Operation range (Outdoor temp.)

CDB

19.4 to 54

21 to 54

Notes : *1:Nominal cooling capacities are based on the following conditions:


(1) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

11

4.5/4.0

KUTALK.....6.80, KUYALK.....7.10

19.4 to 54

Notes : *1:Nominal cooling capacities are based on the following conditions:


(1) Return air temperature: 27CDB, 19.5CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)

50
FHC50KVE

COP *1 (1)

1 phase, 220-240 V, 50 Hz
1.5/1.4

Indoor unit

Power supply

19.4 to 54

Ceiling mounted built-in type

CDB

3.0/3.0

26,600/26,300

6.6/6.5

COP *1 (1)/(2)

2.2/2.2

Btu/h

2.8/2.78

RT

R125FUY1

kcal/h

2.36/2.34

COP *1 (1)/(2)

R100FUY1

*1 (1)/(2)

5.19/5.1

Ceiling mounted cassette corner type

Power comsumption *1 (1)/(2)

R71FUY1

Cooling capacity

2.40/2.37

21 to 52

125
FV125LAVE

R100FUV1

RT

3.7/3.6

2.16/2.15
19.4 to 54

100
FV100LAVE

R71FUV1

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz

kW
CDB

71
FV71LAVE

Outdoor unit

Power supply

kW
COP *1 (1)/(2)
Operation range (Outdoor temp.)

Indoor unit
Model

*1 (1)/(2)

kW
kW

7.8/7.7
3.00/2.98

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz

Operation range (Outdoor temp.)

9,100/9,000

2.60/2.58

Outdoor unit

Power comsumption *1 (1)/(2)

36,200/35,800

6,700/6,600

6.44/6.4

Cooling capacity

Model

26,600/26,300

kcal/h

2.63/2.62

Power supply

Operation range (Outdoor temp.)

3.0/3.0

Btu/h

*1 (1)/(2)

2.45/2.44

Indoor unit

Model

R100FUY1

Cooling capacity

5.34/5.3

Ceiling suspended type

Model

R71FUY1
2.2/2.2

2.64/2.64

21 to 52

R100FUV1

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz

2.02/2.01
19.4 to 54

100
FA100FVEK

R71FUV1

RT

3.7/3.6

kW
CDB

71
FA71FVEK

Outdoor unit

Power supply

kW
COP *1 (1)/(2)
Operation range (Outdoor temp.)

Indoor unit
Model

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

12

Air Cooled Split Type Air ConditionersSpecifications


(For specifications of duct connection series, please refer to P35-P40.)

Heat Pump (60 Hz)


Wall mounted type

Ceiling mounted cassette type


71

Model

100

Indoor unit

FA71FVEK

FA100FVEK

Outdoor unit

R71FUVAL

R100FUVAL

Power supply

Model

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz


2.3/1.9

3.2/2.7

Cooling capacity

Btu/h

27,600/22,900

38,900/32,400

*1 (1)/(2)

kcal/h

7,000/5,800

9,800/8,200

kW

8.1/6.7

11.4/9.5

kW

3.27/4.1

4.41/5.70

2.48

2.59

COP *1 (1)
Operation range (Outdoor temp.)

CDB

Outdoor unit

21 to 54

71

100

125

FV71LAVE

FV100LAVE

FV125LAVE

R71FUVAL

Power supply

R100FUVAL

R125FUTAL

2.3/1.9

3.2/2.6

4.1/3.6

Cooling capacity

27,600/22,900

38,900/30,700

48,800/42,700

*1 (1)/(2)

kcal/h

7,000/5,800

Operation range (Outdoor temp.)

9,800/7,700

12,300/10,800

kW

8.1/6.7

11.4/9.0

14.3/12.5

kW

3.40/4.3

4.62/5.90

6.20/7.10

2.47

2.31

2.38

CDB

125
FHYC125KVE

Outdoor unit

RY50GVAL

RY60GVAL

RY71FUVAL

RY100FUVAL

RY125FUTAL

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
RT
Btu/h

1.6/1.4

1.8/1.6

2.3/1.9

3.2/2.6

4.1/3.6

4.5/4.0

19,800/17,100

22,200/19,100

27,600/22,900

38,900/30,700

48,800/42,700

53,900/47,800

4,990/4,300

5,590/4,800

7,000/5,800

9,800/7,700

12,300/10,800

13,500/12,000

RT

1.8/1.7

2.0/2.0

2.6/2.4

3.6/3.4

4.6/4.3

5.1/4.8

Heating capacity

Btu/h

21,500/20,500

24,500/24,200

30,700/29,000

43,700/40,300

55,300/51,200

61,800/58,000

*2 (1)/(2)

kcal/h

5,420/5,200

6,180/6,100

11,000/10,100
12.8/11.8

13,900/12,900
16.2/15.0

15,600/14,600
18.1/17.0

Operation range
(Outdoor temp.)

Cooling *1 (1)/(2)
Heating *2 (1)/(2)
Cooling

*1 (1)

Heating

*2 (1)

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

5.8/5.0

Heating

8.1/6.7

6.5/5.6

11.4/9.0

14.3/12.5

15.8/14.0

kW

6.3/6.0

7.19/7.1

7,700/7,300
9.0/8.5

kW
kW

2.03/2.34

2.66/3.06

3.72/4.30

4.69/5.90

5.88/6.60

5.70/7.30

1.87/1.85

7.19/7.1

9.0/8.5

12.8/11.8

16.2/15.0

18.1/17.0

2.86
3.37

2.44
2.92

2.18

2.43

2.43

2.77

2.59

2.90

CDB
CWB

Cooling

19.4 to 54

3.23

3.01
-5 to 54

-10 to 15

-10 to 15

-10 to 15.5

Ceiling suspended type


Model

50
FHY50BVE
RY50GVAL

Indoor unit
Outdoor unit

Power supply

60
FHY60BVE
RY60GVAL

71
FHY71BVE
RY71FUVAL

100
FHY100BVE
RY100FUVAL

125
FHY125BVE
RY125FUTAL

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz
RT

1.6/1.4

1.8/1.6

2.3/1.9

3.2/2.6

4.1/3.6

Cooling capacity

Btu/h

19,800/17,100

22,200/19,100

27,600/22,900

38,900/30,700

48,800/42,700

*1 (1)/(2)

kcal/h

4,990/4,300

5,590/4,800

7,000/5,800

9,800/7,700

12,300/10,800

RT

1.8/1.7

2.0/2.0

2.6/2.4

3.6/3.4

4.6/4.3

Heating capacity

Btu/h

21,500/20,500

24,500/24,200

30,700/29,000

43,700/40,300

55,300/51,200

*2 (1)/(2)

kcal/h

5,420/5,200

6,180/6,100

7,700/7,300

11,000/10,100

13,900/12,900

21 to 54

Notes : *1:Nominal cooling capacities are based on the following conditions:


(1) Return air temperature:27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature:29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

140
FHYC140KVE
RY140KUTALK
RY140KUYALK

kcal/h

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
RT

COP *1 (1)

100
FHYC100KVE

Cooling capacity

COP

Btu/h

Power comsumption *1 (1)/(2)

71
FHYC71KVE

*1 (1)/(2)

Power comsumption

Indoor unit

60
FHYC60KVE

kW

Floor standing type


Model

50
FHYC50KVE

Power supply

RT

Power comsumption *1 (1)/(2)

Indoor unit

kW

Power comsumption
COP
Operation range
(Outdoor temp.)

Cooling *1 (1)/(2)
Heating *2 (1)/(2)
Cooling *1 (1)
Heating *2 (1)
Cooling
Heating

5.8/5.0

6.5/5.6

8.1/6.7

11.4/9.0

14.3/12.5

kW

6.3/6.0

7.19/7.1

9.0/8.5

12.8/11.8

16.2/15.0

kW
kW

2.14/2.34

2.77/3.06

3.82/4.30

4.82/5.90

6.05/6.60

1.98/1.86

2.57/2.44

3.60/3.80

4.57/5.00

5.58/5.42

2.35

2.12

2.37

2.36

2.80

2.50

2.80

2.90

2.71
3.18
CDB
CWB

19.4 to 54

-5 to 54

-10 to 15

-10 to 15.5

Ceiling mounted built-in type


Model

71

100

125

Indoor unit

FHYB71FVAL

FHYB100FVAL

FHYB125FVAL

Outdoor unit

RY71FUVAL

RY100FUVAL

RY125FUTAL

Power supply

VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz


RT

2.3/1.9

3.2/2.6

4.1/3.6

Cooling capacity

Btu/h

27,600/22,900

38,900/30,700

48,800/42,700

*1 (1)/(2)

kcal/h

7,000/5,800

9,800/7,700

12,300/10,800

kW

8.1/6.7

11.4/9.0

14.3/12.5

RT

2.6/2.4

3.6/3.4

4.6/4.3

Heating capacity

Btu/h

30,700/29,000

43,700/40,300

55,300/51,200

*2 (1)/(2)

kcal/h

7,700/7,300

11,000/10,100

13,900/12,900

Power comsumption
COP
Operation range
(Outdoor temp.)

Cooling *1 (1)/(2)
Heating *2 (1)/(2)

kW

9.0/8.5

12.8/11.8

16.2/15.0

kW
kW

3.82/4.30

4.76/5.90

6.05/6.70

3.57/3.80

4.49/5.00

5.56/5.60

Cooling

*1 (1)

2.12

2.39

2.36

Heating

*2 (1)

2.52

2.85

2.91

Cooling

CDB

-5 to 54

Heating

CWB

-10 to 15.5

Notes : *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

13

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

14

Air Cooled Split Type Air ConditionersSpecifications

Simultaneous Operation SystemTwin & Triple & Double Twin Multi Application Operation

(For specifications of duct connection series, please refer to P35-P40.)

Simultaneously operates 2 to 4 indoor units using


a single outdoor unit.

Wall mounted type


71
Model

100

Indoor unit

FAY71FVE

FAY100FVE

Outdoor unit

RY71FUVAL

RY100FUVAL

Power supply

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz


RT

2.3/1.9

3.2/2.6

Cooling capacity

Btu/h

27,600/22,900

38,900/30,700

*1 (1)/(2)

kcal/h

7,000/5,800

9,800/7,700

kW

8.1/6.7

11.4/9.0

RT

2.6/2.4

3.6/3.4

Heating capacity

Btu/h

30,700/29,000

43,700/40,300

*2 (1)/(2)

kcal/h

7,700/7,300

11,000/10,100

kW

9.0/8.5

12.8/11.8

kW
kW

3.67/4.20

4.61/5.80

3.44/3.70

4.36/4.90

2.21

2.47

Power comsumption

In large interior spaces a single indoor unit may not be able


to provide uniform comfort. Installation of 2 to 4 units,
distributed to consider sun light and human gathering
patterns, can provide an effective solution.

Cooling *1 (1)/(2)
Heating *2 (1)/(2)

COP

Cooling
Heating

Operation range
(Outdoor temp.)

Cooling
Heating

*1 (1)

2.62

*2 (1)

Installing multiple units is


economical and ensures comfort
Lower cost of installation than for individual pair type
Less space needed for outdoor units
Enhanced comfort from distributed indoor units

2.94
-5 to 54

CDB
CWB

-10 to 15.5

In a single-floor restaurant, for example, positioning 4 units


at strategic locations achieves comfortable air flow that
reaches every inch of the room.

Floor standing type

Note: This type of system does not allow individual control or independent operation of
indoor units. It is not the best choice for large rooms with partitions.

71
Model

100

125

Indoor unit

FVY71LAVE

FVY100LAVE

FVY125LAVE

Outdoor unit

RY71FUVAL

RY100FUVAL

RY125FUTAL

Power supply

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz

Cooling capacity
*1 (1)/(2)

2.3/1.9

3.2/2.6

4.1/3.6

Btu/h

27,600/22,900

38,900/30,700

48,800/42,700

Refrigerant piping uses terminal branching to facilitate installation

12,300/10,800

Branch piping kit is optionally available.

kcal/h

7,000/5,800

9,800/7,700

kW

8.1/6.7

11.4/9.0

14.3/12.5

RT

2.6/2.4

3.6/3.4

4.6/4.3

Heating capacity

Btu/h

30,700/29,000

43,700/40,300

55,300/51,200

*2 (1)/(2)

kcal/h

7,700/7,300

11,000/10,100

13,900/12,900

kW

9.0/8.5

12.8/11.8

16.2/15.0

kW
kW

3.78/4.40

4.77/6.00

6.00/6.70

3.55/3.90

4.52/5.15

5.53/5.60

2.14

2.39

2.38

2.83

2.93

Power comsumption

Cooling *1 (1)/(2)
Heating *2 (1)/(2)

COP

Cooling
Heating

Operation range
(Outdoor temp.)

Cooling
Heating

*1 (1)

2.54

*2 (1)

CDB
CWB

(Indoor units are limited to same capacity and type combination.)

Precautions when selecting optional remote controller


An optional remote controller is required for one of the combination indoor units.
Optional remote controllers are a single item, and cannot operate the air conditioning individually. Indoor units should not therefore be installed in separate rooms.
If operating with optional wireless remote controllers, set one as the main unit and install a light receptor.

Twin Multi Application

-5 to 54
-10 to 15.5

Notes : *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

Indoor units include the super cassette type, duct connection low and middle static pressure type and ceiling suspended type.

RT

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

Branch piping kit


Branch piping kit

Triple Multi Application

Branch piping kit

Double Twin Multi Application

Branch piping kit

Branch piping kit

*Typical combination

15

16

Simultaneous Operation SystemTwin & Triple & Double Twin Multi Application Operation
(For specifications of duct connection series, please refer to P35-P40.)

C ooling Only (50 Hz)


Ceiling mounted cassette type

Model

Indoor unit

Ceiling suspended type


200

250

200

250

FHYC100KVEX 2

FHYC125KVEX 2

FHY100BVEX 2

FHY125BVEX 2

FHYC71KVEX 3

Outdoor unit
Power supply
RT

FHYC50KVEX 4

FHYC60KVEX 4

R200KUY1

R250KUY1

Model

Indoor unit

FHY71BVEX 3

Outdoor unit

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/Y1: 3 phase, 380-415 V, 50 Hz


6.4/6.3
7.7/7.6

Power supply
RT

FHY50BVEX 4

FHY60BVEX 4

RY200KUY1

RY250KUY1

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/Y1: 3 phase, 380-415 V, 50 Hz


6.4/6.3
7.7/7.6

Cooling capacity

Btu/h

76,800/75,700

92,500/90,800

Cooling capacity

Btu/h

76,800/75,700

92,500/90,800

*1 (1)/(2)

kcal/h

19,400/19,100

23,300/22,900

*1 (1)/(2)

kcal/h

19,400/19,100

23,300/22,900

kW

22.5/22.2

27.1/26.6

kW

22.5/22.2

27.1/26.6

7.7/7.6

9.7/9.7

RT

6.4

8.1

2.92/2.92

2.79/2.74

Heating capacity

Btu/h

77,500

96,900

*2 (1)

kcal/h

19,500

24,400

Power comsumption *1 (1)/(2)


COP *1

kW

(1)/(2)

Operation range (Outdoor temp.)

CDB

-5 to 52

Ceiling suspended type

Power comsumption

Indoor unit

200

250

FHY100BVEX 2

FHY125BVEX 2

FHY71BVEX 3

Model
Outdoor unit
Power supply
RT

FHY50BVEX 4

FHY60BVEX 4

R200KUY1

R250KUY1

Btu/h

76,800/75,700

92,500/90,800

*1 (1)/(2)

kcal/h

19,400/19,100

23,300/22,900

kW

22.5/22.2

27.1/26.6

Power comsumption *1 (1)/(2)

kW

7.7/7.6

Operation range (Outdoor temp.)

CDB

Cooling

*1 (1)/(2)

Heating

*2 (1)

22.7

kW
kW

7.7/7.6

28.4
9.7/9.7

6.5

9.2

2.92/2.92

2.79/2.74

3.49

3.09
Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

9.7/9.7

2.92/2.92

(1)/(2)

Heating *2 (1)

kW

Notes : *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27CDB, 19.5CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/Y1: 3 phase, 380-415 V, 50 Hz


6.4/6.3
7.7/7.6

Cooling capacity

COP *1

COP

Cooling *1 (1)/(2)

2.79/2.74
-5 to 52

Heat Pump (50 Hz)


Ceiling mounted cassette type

Model

Indoor unit

200

250

FHYC100KVEX 2

FHYC125KVEX 2

FHYC71KVEX 3

Outdoor unit
Power supply
RT

FHYC50KVEX 4

FHYC60KVEX 4

RY200KUY1

RY250KUY1

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/Y1: 3 phase, 380-415 V, 50 Hz


6.4/6.3
7.7/7.6

Cooling capacity

Btu/h

76,800/75,700

92,500/90,800

*1 (1)/(2)

kcal/h

19,400/19,100

23,300/22,900

kW

22.5/22.2

27.1/26.6

RT

6.4

8.1

Btu/h

77,500

96,900

Heating capacity
*2 (1)

kcal/h

Power comsumption

Cooling *1 (1)/(2)
Heating *2 (1)
Cooling *1 (1)/(2)

COP

Heating

*2 (1)

19,500
22.7

kW
kW

7.7/7.6

9.7/9.7

6.5

9.2

2.92/2.92

2.79/2.74

3.49

3.09

Notes : *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27CDB, 19.5CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)

17

24,400

kW

28.4

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

18

Simultaneous Operation SystemTwin & Triple & Double Twin Multi Application Operation
(For specifications of duct connection series, please refer to P35-P40.)

C ooling Only (60 Hz)

Heat Pump (60 Hz)


Ceiling mounted cassette type

Ceiling mounted cassette type


140

200

250

140

FHYC71KVEX 2

FHYC100KVEX 2

FHYC125KVEX 2

FHYC71KVEX 2

Indoor unit

FHYC71KVEX 3
FHYC50KVEX 3

Model
Outdoor unit

R140KUTALK

Power supply

FHYC60KVEX 4

FHYC50KVEX 4
R200KUTAL

R250KUTAL

R200KUYAL

R250KUYAL

Model

4.5/4.0

6.3/5.7

7.6/6.8

Cooling capacity

Btu/h

53,900/47,800

75,700/68,200

90,800/82,200

*1 (1)/(2)

kcal/h

13,500/12,000

19,100/17,200

22,900/20,700

kW

15.8/14.0

22.2/20.0

26.6/24.1

kW

5.70/6.80

8.20/10.0

10.20/12.5

2.77

2.71

2.61

Power comsumption *1 (1)/(2)


COP *1 (1)
Operation range (Outdoor temp.)

CDB

21 to 54

Heating capacity
*2 (1)/(2)

COP
Operation range
(Outdoor temp.)

140
FHY71BVEX 2
Indoor unit

200
FHY100BVEX 2

FHY50BVEX 3
Outdoor unit

R140KUTALK

Power supply

RY250KUTAL
RY250KUYAL

Cooling *1 (1)/(2)

kW
Heating *2 (1)/(2)
kW
Cooling *1 (1)
Heating *2 (1)
Cooling
CDB
Heating
CWB

4.5/4.0
53,900/47,800
13,500/12,000
15.8/14.0
5.1/4.8
61,900/58,000
15,600/14,600
18.1/17.0
5.7/6.9
5.6/5.7
2.77
3.23
-5 to 54

6.3/5.7
75,800/68,300
19,100/17,200
22.2/20.0
6.4/6.4
77,500/76,500
19,500/19,300
22.7/22.4
8.2/10.0
7.0/7.1
2.71
3.24

7.6/6.8
90,800/82,300
22,900/20,700
26.6/24.1
8.1/8.0
97,000/95,600
24,400/24,100
28.4/28.0
10.2/12.5
9.7/9.9
2.61
2.93
0 to 54

-10 to 15

250
FHY125BVEX 2

RT

FHY50BVEX 4

FHY60BVEX 4

R200KUTAL

R250KUTAL

R200KUYAL

R250KUYAL

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
6.3/5.7
7.6/6.8

Cooling capacity

Btu/h

4.5/4.0
53,900/47,800

75,700/68,200

90,800/82,200

*1 (1)/(2)

kcal/h

13,500/12,000

19,100/17,200

22,900/20,700

kW

15.8/14.0

22.2/20.0

26.6/24.1

kW

5.70/6.90
5.7/6.9

8.20/10.0
8.2/10.0

10.20/12.5
10.2/12.5

2.77

2.71

2.61

COP *1 (1)
Operation range (Outdoor temp.)

FHYC60KVEX 4

FHY71BVEX 3

Model

Power comsumption *1 (1)/(2)

RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW

*1 (1)/(2)

Power comsumption

250
FHYC125KVEX 2

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz

Cooling capacity

-5 to 54

Ceiling suspended type

FHYC50KVEX 3
RY140KUTALK

Power supply

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
RT

Indoor unit
Outdoor unit

200
FHYC100KVEX 2
FHYC50KVEX 4
FHYC71KVEX 3
RY200KUTAL
RY200KUYAL

CDB

-5 to 54

Notes : *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

Ceiling suspended type


140

Model
Outdoor unit
Power supply
RT

Cooling capacity

Btu/h

*1 (1)/(2)

kcal/h
kW
RT

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

Heating capacity

Btu/h

*2 (1)/(2)

kcal/h
kW

Power comsumption
COP
Operation range
(Outdoor temp.)

Cooling *1 (1)/(2)

200
250
FHY100BVEX 2
FHY125BVEX 2
X
FHY71BVE 3
FHY50BVEX 3
FHY60BVEX 4
FHY50BVEX 4
RY200KUTAL
RY250KUTAL
RY140KUTALK
RY200KUYAL
RY250KUYAL
VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
4.5/4.0
6.3/5.7
7.6/6.8
53,900/47,800
75,700/68,200
90,800/82,200
13,500/12,000
19,100/17,200
22,900/20,700
15.8/14.0
22.2/20.0
26.6/24.1
5.1/4.8
6.4/6.4
8.1/8.0
61,800/58,000
77,500/76,400
96,900/95,500
15,600/14,600
19,500/19,300
24,400/24,100
18.1/17.0
22.7/22.4
28.4/28.0
8.2/10.0
6.0/7.2
10.2/12.5
5.9/6.0
7.0/7.1
9.7/9.9
2.63
2.71
2.61
3.07
3.24
2.93
0 to 54
-5 to 54
-10 to 15
FHY71BVEX 2

Indoor unit

kW
Heating *2 (1)/(2) kW
Cooling *1 (1)
Heating *2 (1)
Cooling
CDB
Heating
CWB

Notes : *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

19

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

20

The Intelligent Air Conditioning System

Note: Availability of the products shown in this catalogue varies by country.

Indoor Units.................................24
VRV II Series...............................25
VRV K Series...............................27

VRV II Series

Rising energy and general building services running costs have led end users to
expect a truly complete and acceptable air conditioning system. It must be energy
efficient, economic to run, easy to install, flexible, reliable and user friendly.
Featuring inverter technology and individual control, the VRV system
revolutionised building air conditioning the world over by meeting all these
requirements, and has been installed in various buildings throughout the world for
the last 20 years.

RT

6.4

8.0

12.7

14.3

15.9

19.1

20.7

22.3

23.9

Btu

76400

95500

152900

172000

191100

229300

248400

267500

286600

kW

22.4

28.0

44.8

50.4

56.0

67.2

72.8

78.4

84.0

10

16

18

20

24

26

28

30

HP

HRV (Heat Reclaim Ventilation)..28


Control Systems..........................29

Capacity

Line Up

R410A
Series

Heat pump
Type

50 Hz

Heat pump
Type

60 Hz

Note: Specifications for RT, Btu and kW are based on the following conditions;
Cooling : Indoor temp. of 27-CDB, 19.0CWB, and outdoor temp. of 35.0CDB.

Capacity Range (HP)


8

VRV K series

Air Treatment Equipment


Air flow rate (m3/h)

HRV
(Heat Reclaim Ventilation)

VAM150

21

VAM250

VAM350

VAM500

VAM650

VAM800

VAM1000

VAM1500

VAM 2000

22

Indoor Units

The
series comprises a wide range of indoor units designed
to meet virtually any installation site requirement.

Indoor units
Ceiling Mounted
Cassette Corner Type

Ceiling Mounted Cassette


<Multi flow> Type

Ceiling Mounted Cassette


<Double flow> Type
Thin, lightweight, and easy to
install in narrow ceiling space

FXCQ-MVE

FXFQ-MVE

FXSQ-MVE

Concealed
Floor Standing Type

Floor Standing Type


Perfect unit for perimeter
zone air conditioning

Sophisticated design and


compact casing harmonized in
any interior dcor

Perfect unit to be concealed in


the skirting-wall of perimeter

FXLQ-MVE

FXAQ-MVE

FXHQ-MVE

FXMQ-MVE

FXDQ-NVE(T)*

Wall Mounted Type

Slim body with quieter


and wider air flow

High static pressure allows


flexible duct design

Highly flexible for various


application

Slim design, quietness and


static pressure switching

FXKQ-MVE

Ceiling Suspended Type

Ceiling Mounted Duct Type

Ceiling Mounted
Built-in Type

Slim Ceiling Mounted


Duct Type

Slim design for flexible


installation

New super cassette type


is compact, quiet and
easy to install

FXNQ-MVE

Capacity

*FXDQ-NVE: with a drain-up pump (750 mm lift) as a standard accessory


FXDQ-NVET: without a drain-up pump

Model
name

Type

RT 0.6 ton 0.8 ton


Btu 7500
9600
Index
20
25
HP
0.8 HP 1 HP

1.0 ton 1.3 ton 1.6 ton 2.0 ton 2.6 ton 3.2 ton 4.0 ton 6.4 ton 8.0 ton
12300 15400 19100 24200 30700 38200 47800 76400 95500
31.25
40
50
62.5
80
100
125
200
250
1.25 HP 1.6 HP 2 HP 2.5 HP 3.2 HP 4 HP
5 HP
8 HP 10 HP

Ceiling Mounted Cassette (Double flow)


FXCQ-MVE
Ceiling Mounted Cassette (Multi flow) Super Cassette
FXFQ-MVE
Ceiling Mounted Cassette Corner
FXKQ-MVE
Slim Ceiling Mounted Duct
FXDQ-NVE with
drain-up pump
FXDQ-NVET without
drain-up pump
Ceiling Mounted Built-in
FXSQ-MVE
Ceiling Mounted Duct
FXMQ-MVE
Ceiling Suspended
FXHQ-MVE
Wall Mounted
FXAQ-MVE
Floor Standing
FXLQ-MVE
Concealed Floor Standing
FXNQ-MVE
Note: Specifications for RT and Btu are based on the following conditions; Cooling : Indoor temp. of 27-CDB, 19.0CWB, and outdoor temp. of 35.0CDB.

Connection unit series (50 Hz only)


Wall Mounted

New C eiling S us pended


C as s ette

Floor S tanding

FXAQ-MHV1

C onnec tion unit for indoor unit

FXUQ-MV1

FXLQ-MHV1

BEVQ-MVE

Capacity

H/P: Heat Pump Type

Model
name

Type

RT
0.6 ton
Btu
7500
Index
20
HP
0.8 HP

Wall Mounted
FXAQ-MHV1
Floor Standing
FXLQ-MHV1
New Ceiling Suspended Cassette
FXUQ-MV1
Notes: Specifications for RT and Btu are based on the following conditions;

0.8 ton
9600
25
1 HP

1.0 ton
12300
31.25
1.25 HP

1.3 ton
15400
40
1.6 HP

1.6 ton
19100
50
2 HP

2.3 ton
27300
71
3 HP

3.2 ton
38200
100
4 HP

4.0 ton
47800
125
5 HP

Connectable
Outdoor
Unit
H/P
H/P
H/P

Indoor units in the 63 class are not available for the above models.
Connection unit BEVQ-M is necessary for each indoor unit.

Cooling : Indoor temp. of 27-CDB, 19.0CWB, and outdoor temp. of 35.0CDB.

Cooling Only & Heat Pump


Model

Indoor unit

20

Power supply
Cooling capacity (1)/(2)

Heating capacity

RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW

0.7/0.6
7,800/7,500
2,000/1,900
2.3/2.2
0.7
8,500
2,200
2.5

25

Notes: Cooling capacity is based on indoor temp.


(1)27CDB, 19.5CWB, and outdoor temp. 35CDB.
(2)27CDB, 19.0CWB, and outdoor temp. 35CDB.

23

32

40

50

63

71

80

100

125

200

250

1 phase, 220-240 V/220 V, 50/60 Hz


0.8/0.8
1.1/1.0
1.3/1.3
1.6/1.6
2.1/2.0
2.4/2.3
2.6/2.6
3.3/3.2
4.1/4.0
6.5/6.4
8.2/8.0
9,900/9,600 12,600/12,300 16,000/15,400 19,800/19,100 24,900/24,200 28,300/27,300 31,700/30,700 39,600/38,200 49,500/47,800 78,500/76.400 98,300/95,500
2,500/2,400 3,200/3,100 4,000/3,900 5,000/4,800 6,300/6,100 7,100/6,900 8,000/7,700 10,000/9,600 12,500/12,000 19,800/19,300 24,800/24,100
2.9/2.8
3.7/3.6
4.7/4.5
5.8/5.6
7.3/7.1
8.3/8.0
9.3/9.0
11.6/11.2 14.5/14.0 23.0/22.4 28.8/28.0
0.9
1.1
1.4
1.8
2.3
2.6
2.8
3.6
4.5
7.1
8.9
10,900
13,600
17,000
21,500
27,300
30,700
34,100
42,700
54,600
85,300
107,500
2,800
3,400
4,300
5,400
6,900
7,700
8,600
10,800
13,800
21,500
27,100
3.2
4.0
5.0
6.3
8.0
9.0
10.0
12.5
16.0
25.0
31.5
Heating : Indoor temp. of 20CDB, of 7CDB, 6CWB.
Equivalent piping length : 7.5 m.
Level difference : 0 m.

24

Outdoor units (50Hz)

Outdoor units (60Hz)

HEAT PUMP TYPE

HEAT PUMP TYPE

RT
6.4
8.0 12.7 14.3 15.9 19.1 20.7 22.3 23.9
Btu 76400 95500 152900 172000 191100 229300 248400 267500 286600
Series
kW 22.4 28.0 44.8 50.4 56.0 67.2 72.8 78.4 84.0
HP
8
10
16
18
20
24
26
28
30
Heat pump type

8, 10 HP

16, 18, 20 HP

RXYQ8MY1K(E)
RXYQ10MY1K(E)

(50 Hz)

Note: Specifications for RT, Btu and kW are based on the following conditions;
Cooling : Indoor temp. of 27-CDB, 19.0CWB, and outdoor temp. of 35.0CDB.

RXYQ16MY1K(E)
RXYQ18MY1K(E)
RXYQ20MY1K(E)

24, 26, 28, 30 HP


RXYQ24MY1K(E)
RXYQ26MY1K(E)
RXYQ28MY1K(E)
RXYQ30MY1K(E)

Heat Pump Type (50 Hz)


RXYQ8MY1K(E)
Constituent
Units

RXYQ10MY1K(E)

RXYQ16MY1K(E)

RXYQ18MY1K(E)

RXYQ20MY1K(E)

RXYQ8MY1K(E)
RXYQ8MY1K(E)

RXYQ8MY1K(E)
RXYQ10MY1K(E)

RXYQ10MY1K(E)
RXYQ10MY1K(E)

Power supply

Heating capacity
(*5)

MODE

RXYQ8MYLK(E)

RXYQ10MYLK(E)

RXYQ16MYLK(E)

RXYQ18MYLK(E)

RXYQ20MYLK(E)

RXYQ8MYLK(E)
RXYQ8MYLK(E)

RXYQ8MYLK(E)
RXYQ10MYLK(E)

RXYQ10MYLK(E)
RXYQ10MYLK(E)

RT

6.6/6.5

8.0/6.8

13.1/13.0

14.6/13.3

16.0/13.7

Btu/h

78,800/77,800

96,200/82,200

157,600/155,600

175,000/160,000

192,400/164,500

Constituent
Units

3 phase, 380 V, 60Hz

13.1/13.0

14.6/13.3

16.0/13.7

Btu/h

78,800/77,800

96,200/82,200

157,600/155,600

175,000/160,000

192,400/164,500

kcal/h

19,900/19,600

24,300/20,700

39,700/39,200

44,100/40,300

48,500/41,500

kcal/h

19,900/19,600

24,300/20,700

39,700/39,200

44,100/40,300

48,500/41,500

kW

23.1/22.8

28.2/24.1

46.2/45.6

51.3/46.9

56.4/48.2

kW

23.1/22.8

28.2/24.1

46.2/45.6

51.3/46.9

56.4/48.2

RT

6.4/6.4

8.0/6.8

12.7/12.7

14.3/13.2

15.9/13.7

RT

6.4/6.4

8.0/6.8

12.7/12.7

14.3/13.2

15.9/13.7

Btu/h

76,400/76,400

95,500/82,200

152,900/152,900

172,000/158,700

191,100/164,500

Btu/h

76,400/76,400

95,500/82,200

152,900/152,900

172,000/158,700

191,100/164,500

kcal/h

19,300/19,300

24,100/20,700

38,500/38,500

43,300/40,000

48,200/41,500

kcal/h

19,300/19,300

24,100/20,700

38,500/38,500

43,300/40,000

48,200/41,500

kW

22.4/22.4

28.0/24.1

44.8/44.8

50.4/46.5

56.0/48.2

kW

22.4/22.4

28.0/24.1

44.8/44.8

50.4/46.5

56.0/48.2

RT

7.1

8.9

14.2

16.0

17.9

RT

7.1

8.9

14.2

16.0

17.9

Btu/h

85,300

107,500

170,600

192,800

215,000

Btu/h

85,300

107,500

170,600

192,800

215,000

Power consumption Cooling (*3)/(*4) kW


Heating (*5)
COP (Cooling) (*1)/(*2)
COP (Cooling) (*3)/(*4)
COP (Heating) (*5)
Cooling

21,500

27,100

43,000

54,200

31.5

50.0

56.5

63.0

7.60/9.58

12.6/18.8

13.9/19.0

15.2/19.2

6.01/9.16

7.58/9.56

12.0/18.3

13.6/18.7

15.2/19.1

Power consumption Cooling (*3)/(*4) kW


Heating (*5)

11.6

13.2

14.8

3.69/2.47

3.71/2.52

COP (Cooling) (*1)/(*2)

3.73/2.45

3.69/2.52

3.73/2.45

3.71/2.48

3.69/2.52

COP (Cooling) (*3)/(*4)

4.30

4.26

4.30

4.27

4.26

-5 to 50
-20 to 16

RXYQ28MY1K(E)

RXYQ30MY1K(E)

RXYQ8MY1K(E)
RXYQ10MY1K(E)
RXYQ10MY1K(E)

RXYQ10MY1K(E)
RXYQ10MY1K(E)
RXYQ10MY1K(E)

RT

19.7/19.4

21.1/19.8

22.6/20.2

24.0/20.5

Power supply

3 phase, 380415V, 50Hz

27,100

43,000
50.0

56.5

63.0

12.6/18.8

13.9/19.0

15.2/19.2

6.01/9.16

7.58/9.56

12.0/18.3

13.6/18.7

15.2/19.1

5.82

7.40

11.6

13.2

14.8

3.66/2.42

3.71/2.52

3.66/2.42

3.69/2.47

3.71/2.52

3.73/2.45

3.69/2.52

3.73/2.45

3.71/2.48

3.69/2.52

4.30

4.26

4.30

4.27

4.26

-5 to 50

Heating CWB

-20 to 16

RXYQ24MYLK(E)

RXYQ26MYLK(E)

RXYQ28MYLK(E)

RXYQ30MYLK(E)

Constituent
Units

RXYQ8MYLK(E)
RXYQ8MYLK(E)
RXYQ8MYLK(E)

RXYQ8MYLK(E)
RXYQ8MYLK(E)
RXYQ10MYLK(E)

RXYQ8MYLK(E)
RXYQ10MYLK(E)
RXYQ10MYLK(E)

RXYQ10MYLK(E)
RXYQ10MYLK(E)
RXYQ10MYLK(E)

RT

19.7/19.4

21.1/19.8

3 phase, 380 V, 60Hz


22.6/20.2

24.0/20.5

Btu/h

236,500/233,400

253,900/237,800

271,300/242,300

288,700/246,700

59,600/58,800

64,000/59,900

68,400/61,100

72,800/62,200

84.6/72.3

kW

69.3/68.4

74.4/69.7

79.5/71.0

84.6/72.3

23.9/20.5

RT

19.1/19.1

20.7/19.6

22.3/20.1

23.9/20.5

Btu/h

229,300/229,300

248,400/235,100

267,500/240,900

286,600/246,700

kcal/h

57,800/57,800

62,600/59,300

67,400/60,700

72,200/62,200

kW

67.2/67.2

72.8/68.9

78.4/70.6

84.0/72.3

RT

21.3

23.1

25.0

26.8

Btu/h

255,900

278,100

300,300

322,400

236,500/233,400

253,900/237,800

271,300/242,300

288,700/246,700

59,600/58,800

64,000/59,900

68,400/61,100

72,800/62,200

kW

69.3/68.4

74.4/69.7

79.5/71.0

RT

19.1/19.1

20.7/19.6

22.3/20.1

Btu/h

229,300/229,300

248,400/235,100

267,500/240,900

286,600/246,700

kcal/h

57,800/57,800

62,600/59,300

67,400/60,700

72,200/62,200

kW

67.2/67.2

72.8/68.9

78.4/70.6

84.0/72.3

RT

21.3

23.1

25.0

26.8

Btu/h

255,900

278,100

300,300

322,400

75,700

54,200

31.5
7.60/9.58

CDB

MODE

48,600

25.0

kcal/h

Btu/h

70,100

Cooling

21,500
6.31/9.41

Power supply

kcal/h

64,500

COP (Heating) (*5)


Operation range

RXYQ8MY1K(E)
RXYQ8MY1K(E)
RXYQ10MY1K(E)

Heating (*5)

kW

3.66/2.42

RXYQ26MY1K(E)

Power consumption Cooling (*3)/(*4) kW

kcal/h
Cooling (*1)/(*2)

7.40

RXYQ8MY1K(E)
RXYQ8MY1K(E)
RXYQ8MY1K(E)

kW

Heating capacity
(*5)

3.71/2.52

RXYQ24MY1K(E)

kcal/h

Cooling capacity
(*3)/(*4)

5.82

Constituent
Units

Cooling (*1)/(*2)

Cooling capacity
(*1)/(*2)

3.66/2.42

CDB

MODEL

48,600

25.0
6.31/9.41

Heating CWB

Heating capacity
(*5)

RXYQ24MYLK(E)
RXYQ26MYLK(E)
RXYQ28MYLK(E)
RXYQ30MYLK(E)

8.0/6.8

kW

Cooling capacity
(*3)/(*4)

Note: Specifications for RT, Btu and kW are based on the following conditions;
Cooling : Indoor temp. of 27-CDB, 19.0CWB, and outdoor temp. of 35.0CDB.

24, 26, 28, 30 HP

6.6/6.5

kcal/h

Cooling capacity
(*1)/(*2)

16, 18, 20 HP
RXYQ16MYLK(E)
RXYQ18MYLK(E)
RXYQ20MYLK(E)

RT

Cooling (*1)/(*2)

Operation range

8, 10 HP
RXYQ8MYLK(E)
RXYQ10MYLK(E)

(60 Hz)

Power supply

3 phase, 380415V, 50Hz

Cooling capacity
(*3)/(*4)

RT
6.4
8.0 12.7 14.3 15.9 19.1 20.7 22.3 23.9
Btu 76400 95500 152900 172000 191100 229300 248400 267500 286600
kW 22.4 28.0 44.8 50.4 56.0 67.2 72.8 78.4 84.0
HP
8
10
16
18
20
24
26
28
30
Heat pump type
Series

Heat Pump Type (60 Hz)

MODEL

Cooling capacity
(*1)/(*2)

Capacity

Line Up
Capacity

Line Up

81,300

75.0

81.5

88.0

94.5

18.9/28.2

20.2/28.4

21.5/28.6

22.8/28.7

18.0/27.5

19.6/27.9

21.2/28.3

22.7/28.7

Cooling capacity
(*1)/(*2)

Cooling capacity
(*3)/(*4)

Heating capacity
(*5)

kcal/h
kW
Cooling (*1)/(*2)

Power consumption Cooling (*3)/(*4) kW

64,500

70,100

75,700

81,300

75.0

81.5

88.0

94.5

18.9/28.2

20.2/28.4

21.5/28.6

22.8/28.7

18.0/27.5

19.6/27.9

21.2/28.3

22.7/28.7

17.5

19.0

20.6

22.2

17.5

19.0

20.6

22.2

COP (Cooling) (*1)/(*2)

3.66/2.42

3.68/2.45

3.70/2.49

3.71/2.52

COP (Cooling) (*1)/(*2)

3.66/2.42

3.68/2.45

3.70/2.49

3.71/2.52

COP (Cooling) (*3)/(*4)

3.73/2.45

3.71/2.47

3.70/2.50

3.69/2.52

COP (Cooling) (*3)/(*4)

3.73/2.45

3.71/2.47

3.70/2.50

3.69/2.52

4.30

4.28

4.27

4.26

4.30

4.28

4.27

4.26

COP (Heating) (*5)


Operation range

Cooling

CDB

Heating CWB

-5 to 50
-20 to 16

Note : 1. Optional models (-E type) feature components treated for heat and rust corrosion resistance, such as external panels, fan motor, and electric component box, in addition to the fins of
the heat exchanger. These models are designed specifically for use in areas which are subject to salt damage and atmospheric pollution. Please contact Daikin for more information.
2. Specifications are based on the following conditions;
Cooling : (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35CDB.
(*2) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 46CDB.
Conversion rates
(*3) Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 35CDB.
(*4) Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 46CDB.
kcal/h = kW x 860
Heating : (*5) Indoor temp. of 20CDB, and outdoor temp. 7CDB/6CWB.
Btu/h
= kW x 3412
Sound level : (*4) Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation,
RT = kW x 0.284
these values are normally somewhat higher as a result of ambient conditions.

25

Heating (*5)

COP (Heating) (*5)


Operation range

Cooling

CDB

Heating CWB

-5 to 50
-20 to 16

Note : 1. Optional models (-E type) feature components treated for heat and rust corrosion resistance, such as external panels, fan motor, and electric component box, in addition to the fins of
the heat exchanger. These models are designed specifically for use in areas which are subject to salt damage and atmospheric pollution. Please contact Daikin for more information.
2. Specifications are based on the following conditions;
Cooling : (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35CDB.
(*2) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 46CDB.
Conversion rates
(*3) Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 35CDB.
(*4) Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 46CDB.
kcal/h = kW x 860
Heating : (*5) Indoor temp. of 20CDB, and outdoor temp. 7CDB/6CWB.
Btu/h = kW x 3412
Sound level : (*4) Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation,
RT = kW x 0.284
these values are normally somewhat higher as a result of ambient conditions.

26

VRV K SeriesOutdoor Units

Heat Reclaim Ventilation

The individual control of the air conditioning system for 45 rooms can be realized
by more simple and lesser installation work.

The HRV creates a high-quality environment


by interlocking with the air conditioner
Daikin air conditioner

Shops

Coffee shop and restaurant Dressmaking

Office

Super market Other variety shops


Office
Small and medium size office building
Large house
Amusement center

ON/OFF signal
Cooling/Heating mode signal
Set temperature signal
Ventilation signal
Humidifier ON/OFF signal

Housing
Others

Type

Model
name

Ceiling Mounted Cassette (Double flow)


Ceiling Mounted Cassette (Multi flow) Super Cassette
Ceiling Mounted Cassette Corner
Ceiling Mounted Duct
Ceiling Mounted Built-in
Ceiling Mounted Duct
Ceiling Suspended
Wall Mounted
Floor Standing
Concealed Floor Standing

Capacity

shop

Indoor unit

Operating mode signal


Filter cleaning signal
Failure detection signal

RT
1.0 ton
Btu
12300
Index 31.25
HP
1.25 HP

1.3 ton
15400
40
1.6 HP

1.6 ton
19100
50
2 HP

2.0 ton
24200
62.5
2.5 HP

2.6 ton
30700
80
3.2 HP

3.2 ton
38200
100
4 HP

4.0 ton
47800
125
5 HP

6.4 ton
76500
200
8 HP

FXC-LVE
FXFL-LVE
FXK-LVE
FXYD-KAVE
FXS-LVE
FXM-LVE
FXH-LVE
FXA-LVE
FXL-LVE
FXN-LVE

Daikin's HRV recovers heat energy lost through ventilation and holds
down room temperature changes caused by ventilation, thereby
maintaining a comfortable and clean environment.
The HRV is interlocked to Daikin's
system, SkyAir and other air
conditioning systems and automatically switches over ventilation mode,
further increasing the effects of energy conservation.

Cooling Only & Heat Pump


Indoor unit

31.25

40

Power supply
Cooling capacity (1)/(2)

Heating capacity

RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW

1.1/1.0
12,600/12,300
3,200/3,100
3.7/3.6
1.1
13,600
3,400
4.0

1.3/1.3
16,000/15,400
4,000/3,900
4.7/4.5
1.4
17,100
4,300
5.0

Notes: Specifications are based on the following conditions;


(1)Cooling : 27CDB, 19.5CWB, and outdoor temp. 35CDB.
(2)Cooling : 27CDB, 19.0CWB, and outdoor temp. 35CDB.

50

62.5

80

100

VE: 1 phase, 220-240/220 V, 50/60 Hz


1.6/1.6
2.1/2.0
2.6/2.6
3.3/3.2
19,800/19,100 24,900/24,200 31,700/30,700 39,600/38,200
5,000/4,800
6,300/6,100
8,000/7,700
10,000/9,600
5.8/5.6
7.3/7.1
9.3/9.0
11.6/11.2
1.8
2.3
2.8
3.6
21,500
27,300
34,100
42,700
5,400
6,900
8,600
10,800
6.3
8.0
10.0
12.5

125

200

4.1/4.0
49,500/47,800
12,500/12,000
14.5/14.0
4.5
54,600
13,800
16.0

6.5/6.4
78,500/76,400
19,800/19,300
23.0/22.4
7.1
85,300
21,500
25.0

Heating : Indoor temp. of 20CDB, of 7CDB, 6CWB.


Equivalent piping length : 7.5 m.
Level difference : 0 m.

Cooling capacity (*1)/(*2)

Heating capacity (*3)

Power comsumption
COP
RSNY8KTAL
22.4kw(8HP)

27

Cooling (*1)/(*2)
Heating
Cooling (*1)/(*2)
Heating

VAM350FAVE

VAM500FAVE

VAM1000FAVE

R emote C ontroller

VAM1500FAVE

VAM2000FAVE

HRV Remote Controller

(50 Hz/60 Hz)

Model

RSNY8KTAL

Power supply

Different capacity and different type


of indoor unit can be connected at
the capacity ratio of 50 to 100% of
the outdoor unit, and up to 6 indoor
units can be connected with
individual control.

First-Class Energy Conservation in the Industry


A total of 28% reduction of air conditioning load has been achieved
through a combined use of total heat exchange mode, linked operation
with an air conditioner, and pre-heat/pre-cool control.

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

Cooling Only & Heat Pump

Outdoor Unit

VAM150FAVE

First-Class Compactness in the Industry has been achieved by employing


a originally developed High Efficiency Paper (HEP) element, and using an
optimized fan and airflow passage design.

Note: Specifications for RT and Btu are based on the following conditions; Cooling : Indoor temp. of 27-CDB, 19.0CWB, and outdoor temp. of 35.0CDB.

Model

HRV
LCD remote controller
for indoor unit

RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW

3 phase, 220 V, 60 Hz
6.4/7.1
76,400/85,300
19,300/21,500
22.4/25.0
7.1
85,300
21,500
25.0
8.9/8.5
11
2.52/2.94
2.27

Notes: 1. Optional models (-E type) feature components treated for heat and rust corrosion
resistance, such as external panels, fan motor, and electric component box, in
addition to the fins of the heat exchanger. Please contact Daikin for more
information.
2. Specifications are based on the following conditions;
Cooling: (*1) Indoor temp.: 27.0CDB, 19.0CWB, Outdoor temp.: 35.0CDB
(*2) Indoor temp.: 29.0CDB, 19.0CWB, Outdoor temp.: 46.0CDB
Heating: (*3) Indoor temp.: 20.0CDB, Outdoor temp.: 7.0CDB/6.0CWB.

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

Model

VAM150FAVE VAM250FAVE VAM350FAVE VAM500FAVE VAM650FAVE VAM800FAVE VAM1000FAVE VAM1500FAVE VAM2000FAVE

Power supply

Air Flow Rate (m3/h)


[50 Hz/60 Hz]

External Static
Pressure (Pa)
[50 Hz/60 Hz]
Temp. exchange
efficiency (H/L)
Enthalpy exchange
efficiency (H/L)

1 phase, 220-240 V/220 V, 50 Hz/60 Hz

Ultra-High

150/150

250/250

350/350

500/500

650/650

800/800

1,000/1,000

1,500/1,500

2,000/2,000

High

150/150

250/250

350/350

500/500

650/650

800/800

1,000/1,000

1,500/1,500

2,000/2,000

Low

110/110

155/145

230/210

350/300

500/440

670/660

870/800

1,200/1,200

1,400/1,400

Ultra-High

69/98

64/98

98/142

98/147

93/162

137/225

157/196

137/206

137/196

High

39/54

39/54

70/85

54/54

39/69

98/118

98/108

98/118

78/88

Low

20/24

20/20

25/15

25/20

25/34

49/69

78/69

49/69

% 50 Hz (60 Hz) 74/79(74/80)

59/69

72/77(72/77)

75/80(75/81) 74/77(74/78.5) 74/77(74/78)

74/76(74/76) 75/76.5(75/78) 75/78(75/78)

75/78(75/78)

% For heating
50 Hz (60 Hz)

64/69(64/71)

64/68(64/69)

65/70(65/71) 62/67(62/68.5) 63/66(63/68)

65/67(65/68)

66/68(66/71)

66/68(66/68)

66/70(66/70)

% For cooling
50 Hz (60 Hz)

58/64(58/66)

58/62(58/63)

61/67(61/68) 58/63(58/65.5) 58/63(58/65)

60/62(60/63)

61/63(61/66)

61/64(61/64)

61/66(61/66)

28

Control Systems

Control Systems

Individual Control Systems

Centralized Control Systems


Central remote controller (Optional)

Wired remote controller (Optional)


Large liquid crystal screen displays
complete operating status.
Digital display lets you set
temperature in 1C units.
Lets you individually program by
timer the respective times for
operation start and stop within a
maximum of 72 hours.
Equipped with a thermostat sensor in
the remote controller that makes
possible more comfortable room
temperature control.

Wired remote controller

Constantly monitors malfunctions in


the system for 80 items, and is
equipped with a "self-diagnosis
function" that lets you know by
message immediately when a
malfunction occurs.
Lets you carry out various field
settings by remote controller.

64 groups (zones) of indoor units can be


controlled individually same as LCD Remote controller.
Max.64 groups (128 indoor units controllable)
Max. 128 groups (128 indoor units) are controllable by using 2 central remote controllers,
which can control from 2 different places.
Zone control
Malfunction code display
Max. wiring length 1,000 m (Total : 2,000 m)

DCS302C61

Combination with Unified ON/OFF controller, schedule timer and BMS system
Airflow volume and direction can be controlled individually for indoor units in each group operation.
Ventilation volume and mode can be controlled for Heat Reclaim Ventilation (HRV).

Enables you to select cool/heat/fan


operation mode with the indoor
remote controller of your choice
without using the cool/heat selector.

Up to 4 Operation/Stop pairs can be set per day by connecting a schedule timer.

Set back time clock (Optional)

Unified ON/OFF controller (Optional)


Connected to LCD wired remote controller(BRC type), this time clock can set 2 sets
of on/off times in an increment of 30 minutes within a day. For each on/off setting a

16 groups of indoor units can be operated


simultaneously/individually.

temperature setting is also possible.

Max. 16 groups (128 indoor units) controllable


2 remote controllers can be used to control from 2 different places.
Operating status indication (Normal operation, Alarm)
Centralized control indication
Max. wiring length 1,000 m (Total : 2,000 m)
Compact size casing (Thickness : 16 mm)
Combination with Central Remote controller, Schedule timer and BMS system

DCS301B61

Schedule timer (Optional)

Set back time clock

Wireless remote controller (Optional)

Max.128 indoor units can be operated as


programed schedule.

The same operation modes and settings as with wired remote controllers are
possible.

Max. 128 indoor units controllable


When used in combination with a central remote controller, a maximum of 8 weekly schedule
patterns can be set, while the central controller can be used to select desired zones. Up to 4
Operation/Stop pairs can be set per day.
Max. 48 hours back up power supply
Max. wiring length 1,000 m (Total : 2,000 m)
Compact size casing (Thickness : 16 mm)
Combination with Central Remote controller, Unified ON/OFF controller and BMS system

A light receiving unit for a ceiling-mounted cassette (double-flow, multi-flow) type,


ceiling-suspended type and wall-mounted type is mounted into the indoor unit.
Signal receiving unit can be
installed on the panel
ex. Ceiling mounted cassette (multi-flow) type

DST301B61

Signal receiver unit


(Separate type)

Signal receiver unit

Wireless remote
controller

(Installed type)

Part name

Model No.

Simple remote controller (Optional)


Unification adaptor for computerized control

The remote controller has


centralized its frequently used
operation selectors and
switches (on/off, operation
mode, temperature setting and
airflow volume), making itself
suitable for use in hotel rooms
or conference rooms.

DCS302A52

DTA102A52

Interface adaptor for SkyAir series

For SkyAir, FD(Y)M-FA, FDYB-KA, FDY-KA


FVY(P)J-A, FXUQ-MH, FXLQ-MH

DTA107A55

Central control adaptor kit

For UAT(Y)-K(A), FD-K

Concealed type

Exposed type

29

Adaptors required to connect products other than those of


the VRV System to the high-speed DIII-NET
communication system adopted for the VRV System.
* To use any of the above optional controllers, an appropriate adaptor must be
installed on the product unit to be controlled.

DTA103A51

Wiring adaptor for other air-conditioner

(For hotel use)

Function
Interface between the central monitoring board and central
control units. Combined with the central remote controller,
this adaptor enables the central monitoring board to
centralize such functions as the on/off control, operation
status monitoring, and normal/malfunction monitoring.(*1)

For air conditioners other than mentioned above.


Note : 1. Installation box for

adaptor must be procured on site.

The concealed-type remote controller smartly fits into a


night table or console panel in a hotel room.

30

Control Systems
Daikin's advanced air-conditioning control systems
New

New
Function 4

Air Conditioning
Network Service System
modem for connections

Unification adaptor
for computerized control
[DCS302A52]

Unified ON/OFF and


status monitoring from
the central monitoring panel

Forced OFF contact input

Public phone line


ACC center
Air Conditioning Network Service System
CSV output of power
proportional distribution
results (Optional)

Forced OFF from the fire alarm


Dio Unit

PCMCIA
Flash
Memory

New
Function 2

Pi Port

DCS601C51

RS-232C

New
Function 5

D -NET

New
Function 3

Remote monitoring and control

Trouble reports

Trouble reports

Mobile Phone

New
Function 3

DIII-NET
Plus Adapter
(option)

Indoor Unit

Via
internet

e
rad
Upg New

Wiring adaptor required for connection with


other equipment not compatible with D -NET

Ai unit

D -NET

Dio unit

DAM602A51/52/53

New

Contact signal

Remote PC

Light/Fan
Daikin Central
Air Conditioning
System

Fire alarm Security

Ethernet

D -NET

VRV System

Local
monitoring
& control

Sub PC

Color LCD touch panel icon display


Small manageable size
Simplified engineering
Multi language (English, French, Italian, German, Spanish and Chinese)
Yearly schedule
P.P.D. (Power Proportinal Distribution function) (Optional)
Auto heat/cool change-over
Temperature limitation
History of 500 actions
Air Conditioning Network Service System (Optional Maintenance Service)
Simple Interlock Function

HRV

New
Function 2

Doubling of number of control points


by adding a D -NET Plus Adapter (Optional)
Support for centralized control from elsewhere
using a PC with a Web browser (Optional)

New
Function 3

Sending of e-mail alerts to a specified address


when malfunctions occur (Optional)

New
Function 4

Built-in modem for connecting to


Airnet Service System (Optional)

New
Function 5

Built-in Ethernet port for connecting to


the Internet or an intranet
Management of facilities / equipment
other than A/C units(Compatible with Dio unit and Di unit)

New
Function 1

New
Function 6
e
rad
Upg New

Function 7

Simple Interlock Function

Centralized control system for easy provision of effective control and


monitoring of VRV system functions
Floor visual navigation
Graphical report

New

D -NET

Multi-PC

New
Function 6

Simple Interlock Function

Function 7

Air Conditioning
1
Network Service System
(Optional Maintenance Service)
D -NET

*2

Monitoring of room
enter/exit sign

Di Unit

HRV

Number of indoor unit expanded from 64 to 128.

WatchDOG
Remote

Control pump,
lighting

New
Function 1

Connection to power consumption


meter when using power proportional
distribution function. (Optional)

New communication functions in the user-friendly icon-based multilingual


controller simplify centralized control of the VRV system.
N e w F u n c t io n s

Remote intelligent manager


Multi-PC access
Watch dog function for remote error monitoring
Power limit control
Sliding temperature <optional (DAM101A51) unit required>
Automatic heat/cool change-over
ECO mode
Temperature limitation

N e w F u n c t io n s
Features control and monitoring functions for central
A/C products and an Air Conditioning Network
Service function.
Using an external contact via DIII-NET, monitors and
controls equipment such as lighting, fans, or
building security systems.

Air Conditioning Network Service System (Optional Maintenance Service)


Interfacing requirements vary depending on model, and some systems may not be suitable. Please contact your distributor for details.

Interface for

BACnet and LONWORKS


Integrated control systems that recognize the trend of open control systems

Ethernet
BMS

Compatibility with BMS enhanced by utilizing the international communication standards,


BACnet or LONWORKS.

VRV System

Fire alarm

Security

Elevator
Pump
Lighting
...etc
Power supply facility

HRV
DMS502A51

DMS504B51

(Interface for use in BACnet ) (Interface for use in LONWORKS )

Local Controller

DMS504B51 Interface for use in LONWORKS


XIF file for confirming of specifications of the units.
Connectable up to 10 outdoor units and 64 indoor unit groups.

Please contact Daikin for compatibility with BMS system

DMS502A51 Interface for use in BACnet


Air Conditioning
Network Service System

*5

I/F unit

Maintenance services that boost profits


and customer satisfaction
24 hour on-line diagnostic system
Energy saving and extention of aircon operating life
Maintenance management via A/C network service system reports
Reliable service at shortest lead time

Conformance class 3 (ASHRAE 1351995)


Standard BACnet Device B-ASC (ASHRAE 1352001)

Automatic data transfer

BACnet OPC server compatibility


BACnet /IP over Ethernet

INTERNET
ACC center

Mainfunction information
by E-mail

Up to 40 outdoor units and 256 indoor uit groups on one gateway. (optional adapter)
Local dealers

are restrictions in applicable areas and release times, therefore please consult us separately for details.
*1.2. There
name varies upon the system size.
*3. Model
trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
* BACnet is aisregistered
a registered trade mark of Echelon Corporation.
*4.5. LForONWanORKS
one of the following can be selected: L oc al C ontroller, intelligent touch Controller, or intelligent Manager II.
*6. EthernetI/Fisunit,
a registered trademark of Xerox Corporation.
*

31

32

PACKAGEDAIR CONDITIONERS
Note: Availability of the products shown in this catalogue varies by country.

Packaged air conditioners


Air Cooled Packaged Air Conditioners
Duct Connection Series....................................... 35
Air Cooled Single Packaged Air Conditioners...... 41
Air Cooled Packaged Water Chillers....................42

Line Up
Daikins duct connection type packaged air conditioners are the best choice
for stores and offices. By placing the air conditioner in the ceiling, the design
and finish of all areas remain attractive and unblemished. With minimal
operating sound, people nearby are almost unaware of the units presence.
And simultaneous operation of 2 to 4 indoor units with a single outdoor unit is
possible. When indoor units are distributed taking sunlight and human
occupation patterns into consideration, a comfortable air flow is effectively
spread throughout the room.
Air cooled packaged water chillers are also available.
Such systems can easily meet all the air-conditioning requirements of
factories and other large areas.

Type

Model Name

Air cooled
packaged
duct connection
series
Low static
pressure type

FDBG

Air cooled
packaged
duct connection
series
Middle static
pressure type

FDMG

Air cooled
packaged
duct connection
series
High static
pressure type
Air cooled
single packaged
air conditioners
Roof top type

FDB

Capacity

PACKAGEDAIR CONDITIONERS
RT
Btu
kW
HP

1.6
1.8
2.3
3.2
4.1
4.5
6.8
8.3
13.6 16.6 27.5
19100 22200 27600 38900 48800 53900 81900 99600 163400 199300 331000
5.6
6.5
8.1
11.4 14.3 15.8 24.0 29.2 47.9 58.4 97.1
2
2.5
3
4
5
6
8
10
15
20
30

50 Hz
C/O

60 Hz
50 Hz

FDYB

FD(Y)M

H/P

60 Hz
50 Hz

C/O

Simultaneous
operation
system

60 Hz
50 Hz

FDM

H/P

FD

C/O

FDY

H/P

UAT

C/O 50 Hz
60 Hz

UATY

H/P 50 Hz
60 Hz

60 Hz
50 Hz
60 Hz
50 Hz
60 Hz

Note: Specifications for RT, Btu and kW are based on the following conditions; Power supply: 60 Hz; Cooling: Indoor temp. of 27CDB, 19.0CWB, and outdoor temp. of 35.0CDB.
The values given for 2 HP to 3 HP are for the FDB model, 4 HP to 6 HP are for the FDM model and 8 HP to 20 HP are for the FD model.
The values given for 30 HP are for the UAT model and based on the following conditions; Power supply: 50 Hz; Cooling: Indoor temp. of 27C DB, 19.5C WB, and outdoor temp. of 35.0C DB.

WATER CHILLERS
Type

Air cooled
packaged
water chillers

33

HP
kW

Model Name

2
50

2.5
100

3
150

4
200

5
250

6
300

7.5
400

10
500

15
600

20
700

30
800

50 Hz
UWA

C/O
60 Hz

34

PACKAGEDAIR CONDITIONERS
Air Cooled Packaged Air ConditionersFD(Y)B(G) Series

Air Cooled Packaged Air ConditionersFD(Y)M Series

Duct Connection Series Low Static Pressure Type

Duct Connection Series Middle Static Pressure Type

Perfect for quiet, beautiful, living spaces


like condominiums and apartments,
houses and hotels, and similar living areas

Main unit can be mounted


in the ceiling, and air can be
delivered freely by duct.

Whisper Quiet

Durable

Indoor unit with the industry's lowest level of sound

Handy

FDBG60/71AVE
FDB60/71KVE

FDBG50AVE
FDB50KVE

Small, lightweight and easy-to-install outdoor unit

FDMG71AV1

Durable
The special acryl precoated fin (PE fin) for anti-corrosion
treatment on the outdoor unit heat exchanger ensures
greater resistance against salt damage and atmospheric
pollution than ever.

Easy to read LCD wired remote


controller. (Optional accessory)
(FDYM only)
FDYB50KAVE

R emote C ontroller
For FDMG models

Outdoor Unit
For FD(Y)M models

Central control

FDYB60/71KAVE

Many options are available for use with


large-scale and advanced-function
centrally controlled systems.
(FDYM only)

Easy to read LCD wired remote controller (Optional


accessory for heat pump type) (FDYB only)

R emote C ontroller

FD(Y)M04FAVAL
FDYM05/06FAVAL

FD(Y)M03FAVAL

Easy to Use

Easy to Use

FDMG100/125AV1

The special acryl precoated fin (PE fin)


for anti-corrosion treatment on the
outdoor unit heat exchanger ensures
greater resistance against salt damage
and atmospheric pollution than ever.

LCD wired
remote
controller

Digital Remote
Controller

Signal
Receiver
Unit

Outdoor Unit

For Cooling Only Type

Remote
Controller

For Heat Pump Type

Wireless Remote
Controller

Cooling Only (50 Hz)

Digital Remote
Controller

Remote
Controller

LCD Wired
Remote
Controller

Signal
Receiver
Unit

Indoor unit
Model

Wireless Remote Controller


(Only for Heat Pump)

Cooling Only (50 Hz)


50

60

71

Indoor unit

FDBG50AVE

FDBG60AVE

FDBG71AVE

Outdoor unit

R50GV1

R60GV1K

Cooling capacity
*1 (1)/(2)

Power comsumption *1 (1)/(2)


COP *1 (1)/(2)
Operation range (Outdoor temp.)

CDB

Cooling Only (60 Hz)

Model

Outdoor unit

Power Supply

*1 (2)/(3)

Heating capacity
*2 (1)/(2)

Power comsumption
COP
Operation range
(Outdoor temp.)

Cooling*1 (2)/(3)
Heating*2 (1)/(2)
Cooling*1 (2)
Heating *2 (1)
Cooling
Heating

R71FUV1

RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW

CDB
CWB

Model

R100FUV1

R125FUV1

R71AY1

R100FUY1

2.5/2.5
30,000/29,700
7,600/7,500
8.80/8.7
3.15/3.13
2.79/2.78

V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz


3.0/3.0
36,200/35,800
9,100/9,000
10.6/10.5
4.08/4.04
2.60/2.60
21 to 52

CDB

3.7/3.7
44,700/44,000
11,200/11,000
13.1/12.9
4.89/4.85
2.68/2.66

71

100

125

140

Indoor unit

FDM03FAVAL

FDM04FAVAL

FDM05FAVAL

FDYM06FAVAL

Outdoor unit

R71FUVAL

R100FUVAL

R125FUTAL

R140KUTALK

Power Supply
Cooling capacity
*1 (2)/(3)

Power comsumption *1 (2)/(3)


COP *1 (2)
Operation range (Outdoor temp.)

50

60

71

50

60

71

FDB60KVE

FDB71KVE

FDYB50KAVE

FDYB60KAVE

FDYB71KAVE

R50GVAL

R60GVAL

R71FUVAL

RY50GVAL

RY60GVAL

RY71FUVAL

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz


1.6/1.5
1.8/1.6
2.3/2.0
19,800/17,400
21,800/19,500
27,600/24,600
4,990/4,390
5,500/4,910
7,000/6,200
5.80/5.11
6.40/5.71
8.10/7.20
1.8/1.8
2.0/2.0
2.6/2.6
21,500/21,300
24,500/24,300
30,700/30,700
5,420/5,370
6,180/6,140
7,700/7,700
6.30/6.25
7.19/7.13
9.00/9.00
2.20/2.50
2.70/3.30
3.50/4.20
2.00/2.02
2.44/2.50
3.30/3.30
2.64
2.37
2.31
3.15
2.95
2.73
19.4 to 54
-5 to 54
-10 to 15
-10 to 15.5

Notes: *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27CDB, 19.5CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Shows net capacities. When cooling it is the value minus the heat of the indoor unit fan motor. When heating, the heat of the fan motor is added.

35

R71AV1

Cooling Only (60 Hz)

FDB50KVE

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/VAL: 1 phase, 220 V, 60 Hz


1.8/1.6
2.3/1.9
1.6/1.4
19,100/17,100
22,200/19,100
27,600/22,900
4,820/4,300
5,590/4,800
7,000/5,800
5.60/5.0
6.50/5.6
8.10/6.7

2.10/2.41
2.70/3.29
3.30/3.78

2.67
2.41
2.45

19.4 to 54
21 to 54

RT
Btu/h
kcal/h
kW
kW

R71FUY1

Heat Pump (60 Hz)

Indoor unit

Cooling capacity

Power comsumption *1 (1)/(2)


COP *1 (1)/(2)
Operation range (Outdoor temp.)

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
1.5/1.5
2.0/2.0
2.2/2.2
18,200/18,100
24,000/23,800
26,600/26,300
4,590/4,560
6,050/6,000
6,700/6,600
5.34/5.30
7.03/6.97
7.80/7.70
2.06/2.05
2.76/2.75
2.82/2.8
2.59/2.59
2.55/2.53
2.77/2.75
19.4 to 54
21 to 52

RT
Btu/h
kcal/h
kW
kW

125
FDMG125AV1

Outdoor unit

*1 (1)/(2)

Power Supply

100
FDMG100AV1

Power Supply
Cooling capacity

Model

71
FDMG71AV1

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

RT
Btu/h
kcal/h
kW
kW

2.3/1.9
27,600/22,900
7,000/5,800
8.10/6.7
3.44/3.92
2.35

CDB

VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz


3.2/2.6
4.1/3.6
38,900/30,700
48,800/42,700
9,800/7,700
12,300/10,800
11.40/9.0
14.3/12.5
4.61/5.27
6.25/7.10
2.47
2.29
21 to 54

4.5/4.0
53,900/47,800
13,500/12,000
15.8/14.0
5.80/7.00
2.72

Heat Pump (60 Hz)

Model

71

100

125

140

Indoor unit

FDYM03FAVAL

FDYM04FAVAL

FDYM05FAVAL

FDYM06FAVAL

Outdoor unit

RY71FUVAL

RY100FUVAL

RY125FUTAL

RY140KUTALK

Power Supply
Cooling capacity
*1 (2)/(3)

Heating capacity
*2(1)/(2)

RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW

2.3/1.9
27,600/22,900
7,000/5,800
8.1/6.7
2.6/2.4
30,700/29,000
7,700/7,300
9.00/8.50
3.82/4.37
3.57/3.59
2.12
2.52

VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz


3.2/2.6
4.1/3.6
38,900/30,700
48,800/42,700
9,800/7,700
12,300/10,800
11.4/9.0
14.3/12.5
3.6/3.4
4.6/4.3
43,700/40,300
55,300/51,200
11,000/10,100
13,900/12,900
12.80/11.80
16.20/15.00
4.76/5.25
6.05/6.71
4.49/4.51
5.56/5.60
2.39
2.36
2.85
2.91
-5 to 54
-10 to 15.5

Cooling*1 (2)/(3)
Heating*2 (1)/(2)
Cooling *1 (2)
COP
Heating *2 (1)
Operation range Cooling
CDB
(Outdoor temp.) Heating
CWB
Notes: *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27CDB, 19.5CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
*2:Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Shows net capacities. When cooling it is the value minus the heat of the indoor unit fan motor. When heating, the heat of the fan motor is added.
For FDMG models, capacities show gross capacities which do not include a deduction for evaporator fan motor heat.

Power comsumption

4.5/4.0
53,900/47,800
13,500/12,000
15.8/14.0
5.1/4.8
61,800/58,000
15,600/14,600
18.10/17.00
5.80/7.00
5.80/5.90
2.72
3.12
-10 to 15

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

36

PACKAGEDAIR CONDITIONERS
Air Cooled Packaged Air ConditionersFD(Y) Series

Duct Connection Series High Static Pressure Type

Heat Pump (50 Hz)

Recommended for spacious and large-volume areas because of


its flexible installation. Suitable for large stores, factories, and
other large areas, and for use with housing ducts in homes.

Model

200

250

Indoor unit

FDY08KAY1

FDY10KAY1

FDY15KAY1

FDY20KAY1

Outdoor unit

RY200KUY1

RY250KUY1

RY200KUY1X 2

RY250KUY1X 2

76,800/75,700
6.4/6.3
76,800/75,700
19,300/19,100
22.5/22.2
23.2
6.6
79,200
20,000
23.2
7.2/7.1
76,800/75,700
6.1
19,300/19,100
3.13/3.13
23.2
3.8

Y1: 3 phase, 380-415 V (4 wires), 50 Hz


94,200/92,500
7.8/7.7
150,000/148,000
12.5/12.4
94,200/92,500
150,000/148,000
150,100/148,400
23,700/23,300
37,800/37,400
27.6/27.1
44.0/43.5
29.5
8.4
44.8
12.7
100,700
153,000
152,900
25,400
38,500
29.5
44.8
9.3/9.2
14.4/14.2
94,200/92,500
8.8
150,000/148,000
12.2
23,700/23,300
2.97/2.95
37,800/37,400
3.06/3.06
29.5
3.35
44.8
3.67

184,000/181,000
15.3/15.1
184,000/181,000
183,900/180,800
46,400/45,600
53.9/53.0
56.8
16.1
194,000
193,800
48,800
56.8
18.5/18.3
184,000/181,000
17.6
46,400/45,600
2.91/2.90
56.8
3.23

Power Supply

Highly Adaptable Installation

Cooling capacity

High static pressure and long piping enable flexible


installation and use wherever the unit is placed.

*1 (1)/(2)

Compact

FD03KY1
FD03KVAL

Space-saving outdoor unit also enables lateral


connection.

FD04KY1
FD04KVAL

FD05KY1
FD05KTAL

Heating capacity
*2(1)

Durable

Power comsumption

Highly durable outdoor unit employs PE fins, resists


salt damage and atmospheric pollution.

COP

Cooling*1 (2)/(3)
Heating*2 (1)
Cooling*1 (1)/(2)
Heating *2 (1)/(2)

RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW

400

500

Super Quiet
Indoor unit with the industry's lowest level of sound.

FD06KY1
FD06KTAL

Central control

FD(Y)08K(A)Y1
FD(Y)08K(A)TALYAL

FD(Y)10K(A)Y1
FD(Y)10K(A)TALYAL

Heat Pump (60 Hz)

Many options are available for use with large-scale


and advanced-function centrally controlled
systems.

Indoor unit
Model
Outdoor unit

200

250

FDY08KATAL

FDY10KATAL

FDY15KATAL

FDY20KATAL

FDY08KAYAL

FDY10KAYAL

FDY15KAYAL

FDY20KAYAL

RY200KUTAL
RY200KUYAL

Power Supply

FD(Y)15KAY1
FD(Y)15KATALYAL

R emote C ontroller

Cooling capacity

FD(Y)20KAY1
FD(Y)20KATALYAL

*1 (2)/(3)

Outdoor Unit

Heating capacity
*2(1)/(2)

Power comsumption

Signal
Receiver
Unit

COP

LCD wired
remote controller
(Only for Heat Pump)

Wireless Remote Controller


(Only for Heat Pump)

Operation range
(Outdoor temp.)

Remote
Controller
(Only for Cooling Only)

Cooling Only (50 Hz)


Model

71

100

125

140

200

250

400

500

Indoor unit

FD03KY1

FD04KY1

FD05KY1

FD06KY1

FD08KY1

FD10KY1

FD15KY1

FD20KY1

Outdoor unit

R71FUY1

R100FUY1

R125FUY1

RU06KY1

RU08K(U)Y1

RU10K(U)Y1

RU08K(U)Y1X 2 RU10K(U)Y1X 2

2.3/2.2
27,600/27,000
7,000/6,800
8.1/7.9
2.5/2.48
3.24/3.19

3.1/3.1
37,500/36,800
9,500/9,300
11.0/10.8
3.52/3.48
3.13/3.10

4.0/3.9
47,800/47,100
12,000/11,800
14.0/13.8
4.19/4.15
3.34/3.33

8.4/8.3
101,300/99,600
25,500/25,100
29.7/29.2
9.9/9.8
3.00/2.98

13.8/13.6
16.8/16.6
165,800/163,400 202,300/199,300
41,800/41,200
51,000/50,200
48.6/47.9
59.3/58.4
15.0/14.8
19.8/19.6
3.24/3.24
2.99/2.98

Power Supply
Cooling capacity
*1 (1)/(2)

Power comsumption *1 (1)/(2)


COP *1 (1)/(2)
Operation range (Outdoor temp.)

RT
Btu/h
kcal/h
kW
kW
CDB

Y1: 3 phase, 380-415 V, 50 Hz


4.9/4.9
6.9/6.8
59,400/58,700
82,900/81,900
15,000/14,800
20,900/20,600
17.4/17.2
24.3/24.0
5.7/5.7
7.5/7.4
3.05/3.02
3.24/3.24
21 to 52

Cooling*1 (2)/(3)
Heating*2 (1)/(2)
Cooling*1 (2)
Heating *2 (1)
Cooling
Heating

RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW

CDB
CWB

6.3/5.6
75,700/67,600
19,100/17,000
22.2/19.8
6.6/6.5
79,200/78,100
20,000/19,700
23.2/22.9
7.7/9.4
6.6/6.7
2.88
3.52

400

500

RY250KUTAL

RY200KUTALX 2

RY250KUTALX 2

RY250KUYAL

RY200KUYALX 2

RY250KUYALX 2

TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz


7.7/6.9
12.4/11.0
92,500/82,900
148,400/132,000
23,300/20,900
37,400/33,300
27.1/24.3
43.5/38.7
8.4/8.3
12.7/12.7
100,700/99,300
152,900/152,200
25,400/25,000
38,500/38,400
29.5/29.1
44.8/44.6
9.7/11.9
15.3/18.8
9.3/9.5
13.2/13.4
2.79
2.84
3.17
3.39
0 to 54
-10 to 15

Notes: *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27CDB, 19.5CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

15.1/13.4
180,800/161,400
45,600/40,700
53.0/47.3
16.1/16.1
193,800/193,100
48,800/48,700
56.8/56.6
19.4/23.8
18.6/19.0
2.73
3.05

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

Cooling Only (60 Hz)


71
Model

100

125

140

200

Indoor unit

FD03KVAL

FD04KVAL

FD05KTAL

FD06KTAL

FD08KTAL

Outdoor unit

R71FUVAL

R100FUVAL

R125FUTAL

RU06KTAL

RU08K(U)TAL

2.4/2.0
29,000/24,200
7,300/6,100
8.5/7.1
3.22/3.70
2.64

3.4/2.6
40,600/30,700
10,200/7,700
11.9/9.0
4.37/5.02
2.72
21 to 54

Power Supply
Cooling capacity
*1 (2)/(3)

Power comsumption *1 (2)/(3)


COP *1 (2)
Operation range (Outdoor temp.)

RT
Btu/h
kcal/h
kW
kW
CDB

250

400

500

FD10KTAL

FD15KTAL

FD20KTAL

RU10K(U)TAL RU08K(U)TALX 2 RU10K(U)TALX 2

VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz


4.3/4.0
4.9/4.5
6.8/6.2
8.3/7.6
51,900/48,100
59,000/53,600
81,900/74,700
99,600/91,100
13,100/12,100
14,900/13,500
20,600/18,800
25,100/23,000
15.2/14.1
17.3/15.7
24.0/21.9
29.2/26.7
5.88/6.73
6.50/7.90
8.30/10.10
10.30/12.60
2.59
2.66
2.89
2.83

Notes: *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27CDB, 19.5CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

37

13.6/12.4
16.6/15.1
163,400/149,400 199,300/181,900
41,200/37,700
50,200/45,800
47.9/43.8
58.4/53.3
16.60/20.20
20.60/25.30
2.89
2.83

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

38

PACKAGEDAIR CONDITIONERS
Simultaneous Operation SystemTwin, Triple & Double Twin Multi Application Operation

Simultaneously operates 2 to 4 indoor units using


a single outdoor unit.

Heat Pump (50 Hz)


Model

Indoor unit

FDYM04FAV1X 2

FDYM05FAV1X 2

FDYM03FAV1X 3

Outdoor unit

RY200KUY1

RY250KUY1

RY200KUY1

Power Supply

In large interior spaces a single indoor unit may not be able to provide uniform comfort. Installation of 2 to 4 units, distributed to
consider sun light and human gathering patterns, can provide an effective solution.

Installing multiple units is economical and ensures comfort

Cooling capacity
*1(1)/(2)

Heating capacity

In a single-floor restaurant, for example, positioning 4 units at strategic locations achieves comfortable air flow that reaches
every inch of the room.
Lower cost of installation than for individual pair type

*2(1)

Power comsumption
COP

Less space needed for outdoor units

Cooling*1 (1)/(2)
Heating*2 (1)
Cooling*1 (1)/(2)
Heating *2 (1)

RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
6.4/6.3
7.7/7.6
6.4/6.3
76,800/75,700
92,500/90,800
76,800/75,700
19,400/19,100
23,300/22,900
19,400/19,100
22.5/22.2
27.1/26.6
22.5/22.2
6.4
8.1
6.4
77,500
96,900
77.500
19,500
24,400
19,500
22.7
28.4
22.7
7.7/7.6
9.9/9.9
8.0/7.9
6.5
9.4
6.8
2.92/2.92
2.69/2.74
2.81/2.81
3.49
3.02
3.34

Enhanced comfort from distributed indoor units


Cooling Only (60 Hz)

Note: This type of system does not allow individual control or independent operation of indoor units. It is not the best choice for large rooms with partitions.

Indoor unit
Model

Twin Multi Application

Triple Multi Application

Double Twin Multi Application

Outdoor unit

*1(2)/(3)

Branch piping kit

Branch piping kit

250

200

FDYM05FAVALX 2

FDYM03FAVALX 3

R200KUTAL

R250KUTAL

R200KUTAL

R200KUYAL

R250KUYAL

R200KUYAL

6.3/5.7
75,700/68,200
19,100/17,200
22.0/20.0
8.2/10.0
2.71

VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz


7.6/6.8
90,800/82,200
22,900/20,700
26.6/24.1
10.4/12.7
2.56
-5 to 54

6.3/5.7
75,700/68,200
19,100/17,200
22.2/20.0
8.5/10.3
2.61

Power Supply
Cooling capacity

Power comsumption *1 (2)/(3)


COP *1 (2)
Operation range (Outdoor temp.)

Branch piping kit

200
FDYM04FAVALX 2

RT
Btu/h
kcal/h
kW
kW

CDB

Branch piping kit

Heat Pump (60 Hz)


200
Model

FDYB60KAVEX 4

FDYB71KAVEX 3

RY250KUTALYAL

RY200KUTALYAL

Cooling capacity

Model

*1(2)/(3)

200

250

200

Indoor unit

FDYM04FAV1X 2

FDYM05FAV1X 2

FDYM03FAV1X 3

Outdoor unit

R200KUY1

R250KUY1

R200KUY1

6.4/6.3
76,800/75,700
19,400/19,100
22.5/22.2
7.7/7.6
2.92/2.92

V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz


7.7/7.6
92,500/90,800
23,300/22,900
27.1/26.6
9.9/9.9
2.74/2.69
-5 to 52

6.4/6.3
76,800/75,700
19,400/19,100
22.5/22.2
8.0/7.9
2.81/2.81

Power Supply
RT
Btu/h
kcal/h
kW
kW

Cooling capacity
*1(1)/(2)

Power comsumption *1 (1)/(2)


COP *1 (1)/(2)
Operation range (Outdoor temp.) CDB

200

FDYB50KAVEX 4
RY200KUTALYAL

Power Supply

Cooling Only (50 Hz)

250

Indoor unit
Outdoor unit

Heating capacity
*2(1)/(2)

Power comsumption Cooling*1 (2)/(3)


Heating*2 (1)/(2)
COP
Cooling*1 (2)
Heating *2 (1)
Operation range Cooling
(Outdoor temp.) Heating

RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW

CDB
CWB

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz
6.3/5.7
7.6/6.8
6.3/5.7
75,700/68,200
90,800/82,200
75,700/68,200
19,100/17,200
22,900/20,700
19,100/17,200
22.2/20.0
26.6/24.1
22.2/20.0
6.4/6.4
8.1/8.0
6.4/6.4
77,500/76,400
96,900/95,500
77,500/76,400
19,500/19,300
24,400/24,100
19,500/19,300
22.7/22.4
28.4/28.0
22.7/22.4
8.2/10.0
10.2/12.6
8.20/10.00
7.0/7.1
9.7/10.0
7.0/7.1
2.71
2.61
2.71
3.24
2.93
3.24
0 to 54
-10 to 15

Heat Pump (60 Hz)


Heat Pump (50 Hz)
Model

Indoor unit

FDYB50KAVEX 4

FDYB71KAVEX 3

FDYB60KAVEX 4

Outdoor unit

RY200KUY1

RY200KUY1

RY250KUY1

Power Supply
Cooling capacity
*1(1)/(2)

Heating capacity
*2(1)

Power comsumption
COP

Cooling*1 (1)/(2)
Heating*2 (1)
Cooling*1 (1)/(2)
Heating *2 (1)

RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW

VE: 1 phase, 220-240 V/220 V, 50/60 Hz/V1: 1 phase, 220-240 V, 50 Hz/Y1: 3 phase, 380-415 V, 50 Hz
6.4/6.3
6.4/6.3
7.7/7.6
76,800/75,700
76,800/75,700
92,500/90,800
19,400/19,100
19,400/19,100
23,300/22,900
22.5/22.2
22.5/22.2
27.1/26.6
6.4
6.4
8.1
77,500
77,500
96,900
19,500
19,500
24,400
22.7
22.7
28.4
7.7/7.6
7.7/7.6
9.7/9.7
6.5
6.5
9.2
2.92/2.92
2.92/2.92
2.79/2.74
3.49
3.49
3.09

Notes: *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27CDB, 19.5CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

39

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

Model

200

250

200

Indoor unit

FDYM04FAVALX 2

FDYM05FAVALX 2

FDYM03FAVALX 3

Outdoor unit

RY200KUTALYAL

RY250KUTALYAL

RY200KUTALYAL

Power Supply
Cooling capacity
*1(2)/(3)

Heating capacity
*2(1)/(2)

RT
Btu/h
kcal/h
kW
RT
Btu/h
kcal/h
kW
kW
kW

Power comsumption Cooling*1 (2)/(3)


Heating*2 (1)/(2)
COP
Cooling*1 (2)
Heating *2 (1)
Operation range Cooling
CDB
(Outdoor temp.) Heating
CWB

6.3/5.7
75,700/68,200
19,100/17,200
22.2/20.0
6.4/6.4
77,500/76,400
19,500/19,300
22.7/22.4
8.2/10.0
7.0/7.1
2.71
3.24

VAL: 1 phase, 220 V, 60 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz


7.6/6.8
90,800/82,200
22,900/20,700
26.6/24.1
8.1/8.0
96,900/95,500
24,400/24,100
28.4/28.0
10.4/12.5
9.9/10.1
2.56
2.87
0 to 54
-10 to 15

Notes: *1: Nominal cooling capacities are based on the following conditions:
(1) Return air temperature: 27CDB, 19.5CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 27CDB, 19.0CWB, Outdoor temperature: 35CDB Equivalent ref. piping: 5 m (Horizontal)
(3) Return air temperature: 29CDB, 19.0CWB, Outdoor temperature: 46CDB, 24CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
*2: Nominal heating capacities are based on the following conditions:
(1) Return air temperature: 20CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 5 m (Horizontal)
(2) Return air temperature: 21CDB, Outdoor temperature: 7CDB, 6CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)

6.3/5.7
75,700/68,200
19,100/17,200
22.2/20.0
6.4/6.4
77,500/76,400
19,500/19,300
22.7/22.4
8.5/10.3
7.3/7.4
2.61
3.11

Conversion rates
kcal/h = kW x 860
Btu/h = kW x 3412
RT = kW x 0.284

40

PACKAGEDAIR CONDITIONERS

WATER CHILLERS

Air Cooled Single Packaged Air ConditionersUAT(Y) Series

Air Cooled Packaged Water ChillersUWA Series

Roof Top Type


Easy to install on rooftop or veranda, requiring only ducting,
power line and drain piping.
In addition to its high efficiency, the scroll compressor is 10%
lighter and 30% more compact than conventional
reciprocating compressors. This makes this series among the
industry's most lightweight and compact than previous models.
Also, since the scroll compressor generates less vibration, this
series has greatly improved its durability and achieved the
industry's lowest operation sound. (UAT(Y)-K Series)

UAT08 09 1012KA
UATY08 09 1012K

UAT06KA
UATY06K

Efficient cross fin coils are used: the unique waffle louver
fins*1 maximize heat exchange efficiency, while the Hi-XA
copper tube*2, featuring an inner spiral groove, fully exploits
refrigerant turbulence to help increase heat exchange
efficiency. The result is substantial energy savings.

UWA55JAY1

UWA138JY1

Wide Operation Range:

UWA80JATJ

Energy saving.

U.S. PAT. *1; No.4,434,844 *2; No.4,480,684

R emote C ontroller

Digital Remote Controller

UAT30H

UAT15 1821KA
UATY15 1821K

Remote Controller
(Only for Cooling Only)

Cooling Only (50 Hz/60 Hz)


UAT06KAY1 UAT08KAY1 UAT09KAY1
UAT06KATAL UAT08KATAL UAT09KATAL
UAT06KAYAL UAT08KAYAL UAT09KAYAL

Model

UAT12KATAL UAT15KAY1 UAT18KAY1 UAT21KAY1


UAT10KAY1
UAT12KAYAL UAT15KATAL UAT18KATAL UAT21KATAL
(50 Hz Only)
(60 Hz Only) UAT15KAYAL UAT18KAYAL UAT21KAYAL

UAT30HY1
UAT30HTO

Power Supply

Y1: 3 phase, 380-415 V, 50 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz/TO: 3 phase, 200/200-220 V, 50/60 Hz
RT
5
6
7.5
9
10
12.5
15
17.5
27.5/30
Cooling capacity *1
Btu/h
60,300
75,000
90,000
107,200
120,000
150,000
180,000
210,400
331,000/368,000
(50/60 Hz)
kcal/h
15,200
18,900
22,700
27,000
30,200
37,800
45,300
53,000
83,500/92,600
kW
17.7
22.0
26.4
31.4
35.1
43.9
52.7
61.6
97.1/107.7
Btu/h
52,900
67,600
81,200
96,600
107,800
135,200
162,100
189,400
284,000/330,700
Cooling capacity *2
(50/60 Hz)
kW
15.5
19.8
23.8
28.3
31.6
39.6
47.5
55.5
83.1/96.9
TAL
8.26
9.74
9.18

8.86
9.52
8.64
8.98

EER *3
(Cooling)
YAL
8.28
9.78
9.21

8.94
9.52
8.64
9.00

Operation range (Outdoor temp.)


CDB
21 to 52 (UAT06KAY1/TAL/YALUAT21KAY1/TAL/YAL, UAT30HY1)
Notes: 1. The above data marked with *1 are rated in accordance with JIS C-9612. 27CDB (80FDB)/ 19.5CWB (67FWB) indoor temp. And 35CDB (95FDB) outdoor temp.
2. The above data marked with *2 are rated in accordance with SSA-385/386, 29CDB (84FDB)/ 19CWB (66FWB) indoor temp. And 46CDB (115FDB) outdoor temp.
3. The figures of *2 are reference value.
Net capacity (Btu/h)
4. Capacity (*1, 2) is gross capacity which does not include a deduction for evaporator fan motor heat.
EER =
5. *3: EER conditions: 27CDB (80FDB) and 19.5CWB (67FWB) for indoor temp. 35CDB (95FDB) for outdoor temp.
Unit power comsumption (W)
(Compressor + Outdoor fan motor)

UATY06KY1
UATY06KTAL
UATY06KYAL

Model
Power Supply

Cooling capacity *2
(50/60 Hz)
Heating capacity *3
(50/60 Hz)
EER *3
(Cooling)
EER *4
(Heating)
Power comsumption *1
(Cooling)
Power comsumption
(Heating)

RT
Btu/h
kcal/h
kW
Btu/h
kW
Btu/h
kcal/h
kW
TAL
YAL
TAL
YAL
Y1
kW
TAL
YAL
Y1
TAL
YAL

kW

5
60,300
15,200
17.7
52,900
15.5
62,000
15,600
18.1
8.26
8.28
9.45
9.47
5.8
6.8
6.8
5.3
6.2
6.2

UATY08KY1
UATY08KTAL
UATY08KYAL

UATY09KY1
UATY09KTAL
UATY09KYAL

UATY10KY1
(50 Hz Only)

UATY12KTAL
UATY12KYAL
(60 Hz Only)

UATY15KY1
UATY15KTAL
UATY15KYAL

UATY18KY1
UATY18KTAL
UATY18KYAL

Y1: 3 phase, 380-415 V, 50 Hz/TAL: 3 phase, 220 V, 60 Hz/YAL: 3 phase, 380 V, 60 Hz


6
7.5
9
10
12.5
15
75,000
90,000
107,200
120,000
150,000
180,000
18,900
22,700
27,000
30,200
37,800
45,300
22.0
26.4
31.4
35.1
43.9
52.7
67,600
81,200
96,600
107,800
135,200
162,100
19.8
23.8
28.3
31.6
39.6
47.5
78,600
91,700
109,600
123,000
157,200
185,000
19,800
23,100
27,600
31,000
39,600
46,600
23.0
26.9
32.1
36.1
46.1
54.2
9.74
9.18

8.86
9.52
8.64
9.78
9.21

8.94
9.52
8.64
11.44
10.22

9.81
11.23
9.74
11.49
10.25

9.87
11.24
9.74
6.3
8.2
9.9

13.0
17.1
6.8
8.9

11.8
13.6
18.6
6.8
8.9

11.8
13.6
18.6
5.7
7.7
9.4

11.8
15.8
5.7
8.3

11.3
12.4
17.4
5.7
8.3

11.3
12.4
17.4

UATY21KY1
UATY21KTAL
UATY21KYAL

Two independent refrigerant circuit.


(UWA63JAY1109JAY1, UWA70JATJ122JATJ, UWA120JY1270JY1)
The selector switch makes it possible to operate only one refrigerant circuit
while one need repairing.

Cooling Only (50 Hz)


Model

UWA37JAY1

UWA47JAY1

Power supply
Cooling capacity *1

Cooling capacity *2

kW
Btu/h
USRT
kW
Btu/h
USRT

Model

UWA75JAY1

UWA80JAY1

Power supply
Cooling capacity *1

Cooling capacity *2

kW
Btu/h
USRT
kW
Btu/h
USRT

17.5
210,400
53,000
61.6
189,400
55.5
214,400
54,000
62.8
8.98
9.00
9.99
10.01
19.8
20.6
20.6
18.5
19.4
19.4

2. Cooling capacities marked with *2 are based on 29CDB (84FDB) 19.0CWB (66FWB) indoor temp. and 46CDB (115FDB) outdoor temp.
3. Heating capacities are based on 21CDB for indoor temp. 7CDB/6CWB for outdoor temp.
Net capacity (Btu/h)
4. The figures of *2 is reference value.
EER =
5. *3: EER Cooling conditions: 27CDB (80FDB) and 19.5CWB (67FWB) for indoor temp. 35CDB (95FDB) for outdoor temp.
Unit power comsumption (W)
6. *4: EER Heating conditions: 20CDB for indoor temp. 7CDB/6CWB for outdoor temp.
(Compressor + Outdoor fan motor)

UWA55JAY1

UWA63JAY1

3 phase, 380-415 V, 50 Hz
137.2
161.3
468,200
550,400
39.0
45.8
124.8
149.9
425,800
511,500
35.4
42.6

108.4
369,800
30.8
97.4
332,500
27.7

186.0
634,900
52.9
167.4
571,400
47.6

UWA93JAY1

UWA109JAY1

3 phase, 380-415 V, 50 Hz
250.6
272.7
855,100
930,500
71.2
77.5
225.5
250.8
769,400
855,900
64.1
71.3

219.1
747,600
62.3
197.1
672,600
56.0

319.2
1,089,200
90.7
290.5
991,200
82.6

Cooling Only (50 Hz)


Model

UWA120JY1

UWA138JY1

Power supply

Operation range
5 to 52
Cooling CDB
(Outdoor temp.)
Heating CWB
-10 to 15.5
Notes: 1. Cooling capacities marked with *1 are based on 27CDB (80FDB) 19.5CWB (67FWB) indoor temp. and 35CDB (95FDB) outdoor temp.

41

Capacity can be controlled in multiple steps from 3 to 7 steps to save


energy.

Equipped with a compact and


powerful semi-hermetically sealed
reciprocating compressor.

Heat Pump (50 Hz/60 Hz)

Cooling capacity *1
(50/60 Hz)

(UWA37JAY1109JAY1, UWA43JATJ122JATJ, UWA120JY1270JY1)

Operative high outdoor temperature.


UWA37JAY1109JAY1: 5 to 52C
UWA27JATJ, 37JATJ: 15 to 49C
UWA43JATJ122JATJ: 5 to 49C
UWA120JY1270JY1: 5 to 49C

Cooling capacity *1

kW
Btu/h
USRT

351.6
1,201,500
99.9

404.4
1,380,800
115.0

UWA162JY1

UWA192JY1

3 phase, 380-415 V, 50 Hz
474.7
562.8
1,620,600
1,921,500
135.0
160.0

UWA228JY1

UWA270JY1

667.9
2,280,400
189.9

791.0
2,700,800
224.7

Cooling Only (60 Hz)


Model

UWA27JATJ

UWA32JATJ

UWA43JATJ

UWA53JATJ

UWA62JATJ

79.0
269,800
22.4
71.0
242,000
20.1

94.3
320,600
26.7
82.0
280,900
23.4

3 phase, 208-230 V, 60 Hz
125.0
426,600
35.5
111.0
378,900
31.5

162.0
553,500
46.1
145.0
494,000
41.0

185.0
632,100
52.6
171.0
584,100
48.6

UWA70JATJ

UWA80JATJ

UWA90JATJ

UWA108JATJ

UWA122JATJ

253.0
865,000
72.0
219.0
746,400
62.1

3 phase, 208-230 V, 60 Hz
274.0
936,400
78.0
248.0
845,200
70.4

324.0
1,107,000
92.2
285.0
972,200
81.0

370.0
1,262,000
105.0
335.0
1,145,000
95.3

Power supply
Cooling capacity *1

Cooling capacity *2

kW
Btu/h
USRT
kW
Btu/h
USRT

Model
Power supply
Cooling capacity *1

Cooling capacity *2

kW
Btu/h
USRT
kW
Btu/h
USRT

212.0
722,200
60.0
191.0
653,100
54.2

Notes : *1 Cooling capacity is based on the following conditions: Leaving chilled water temp. 6.7C (44F), entering water temp. 12.2C (54F) outdoor temp. 35C (95FDB).
*2 Cooling capacity is based on the following conditions: Leaving chilled water temp. 6.7C (44F), entering water temp. 12.2C (54F) outdoor temp. 46.0C (115FDB).

42