7/30/2004

DATA SHEET FOR ATMOSPHERIC TANK - API 650 - METHOD BY PIE PIE 1-Fluid: Name: Water Cp (cal / g C) 0.238 Vapor Pressure @ 200 F, psia 11.53 SG 1 Viscosity @ 130 F (centistokes) 0.55 PM 18 r @ 200 F (lbm/pie3) 60.13 2-Tank Dimensions: Nominal Diameter Nominal Height Liquid Height Nominal Capacity 3-Tuberias asociadas al Tanque: NOZZLE N1 N2 N3 N6 N4 N5 N8 N7 N9 A/B N10 Service Water Inlet Water Outlet Water Service Fire Water Output Fire Water Recirculation Entry Vent Manhole Overflow Drainage Stand Pipe Low Level Switch TOTALS = Number 1 1 1 1 1 2 1 1 2 1 Diameter (in.) 8 4 16 8 12 24 10 4 2 2

35 feet (10.7 meters) 40 feet (12.2 meters) 39 feet (11.9 meters) 1000 cubic meters

4-Details of Operation: Design Temperature, T1 Design Pressure (Feet of Water Column) Air Pressure (psia) Altitude (m.s.n.m.) Check-N1 Pressure (Psig) N1 Entrance Flow (GPM) Adduction allowable speed in N1 (m / sec) 5-Boquillas y Conexiones: Nozzle N1 N2 N3 N6 N4 N5 N8 N7 N9 A/B N10

200F (93 C) 492 14.7 350

Service Water Inlet Water Outlet Water Service Fire Water Output Fire Water Recirculation Entry Vent Manhole Overflow Drainage Stand Pipe Low Level Switch TOTALS =

Number 1 1 1 1 1 2 1 1 2 1

Diameter (in.) 8 4 16 8 12 24 10 4 2 2

Schedule 40 40 40 40 40 40 40

Length (m)

Weight (lb)

Weight (kg)

Material

0.00

0.00

Weight (lb) 48.50 20.00 173.00 48.50 100.00 662.00 70.00 20.00 15.00 7.50 1164.50

Weight (kg) 31.75 9.07 78.47 22.00 45.35 300.27 31.75 9.07 6.80 3.40 537.93

Material A-105 A-105 A-105 A-105 A-105 A-105 A-105 A-105 A-105 A-105

Only enter data in unshaded cells


Module 14 Calculate Calculates atmospheric tanks CALCULATION ACCORDING TO API 650 - METHOD BY PIE PIE TICKETS GENERAL INFORMATION PCA Design Pressure = Height of tank (filled with water) 12 PCA 396.00 Design Temperature, C 93.00 Tank Diameter, ft 60.00 Tank Height (Limit Calculation = 80 ft), ft 32.00 Stored Fluid Specific Gravity (Water = 1) 1.00 Allowable stress for the Status of Design, Psi 23,200.00 Corrosion Thickness, in. 0.0625 Roof inclination angle to the horizontal, degrees 25.00 Required Tank Capacity, cubic meters Standard blade Blade length, feet 20.00 Blade width, feet 8.00 Standard Print Area, m2 Density of Steel Plate, Kg/m3 OUTPUTS Rings = Aa= NLanillo= Tpared-A1 = Tpared-A1n = Tpared-A2 = Tpared-A2n = Tpared-A3 = Tpared-A3n = Tpared-A4 = Tpared-A4n = Tpared-A5 = Tpared-A5n = Tpared-A6 = Tpared-A6n = Tpared-A7 = Tpared-A7n = Tpared-A8 = Tpared-A8n = Tpared-A9 = Tpared-A9n = Tpared-A10 = Tpared-A10n = Vct= Pct= Thickness: Wall Plates Number Plates Standard Rings One Ring Area, m2 Required Number of Prints per ring Minimum thickness of plate in Ring 1, mm Plate thickness Ring 1 Nominal, mm Minimum thickness of plate in Ring 2 mm Plate thickness Ring 2 Nominal, mm Minimum thickness of plate in Ring 3 mm Plate thickness Ring 3 Nominal, mm Minimum thickness of plate in Ring 4 mm Plate thickness Ring 4 Nominal, mm Minimum thickness of plate in Ring 5 mm Ring thicknesses 5 Nominal, mm Minimum thickness of plate in Ring 6 mm Ring thicknesses 6 Nominal, mm Minimum thickness of plate in Ring 7 mm Ring thicknesses 7 Nominal, mm Minimum thickness of plate in Ring 8 mm Plate thickness Ring 8 Nominal, mm Minimum thickness of plate in Ring 9 mm Plate thickness Ring 9 Nominal, mm Minimum thickness of plate in Ring 10 mm Ring Thickness 10 Print Nominal, mm Tank Corps Volume, m3 Tank Body Weight, kg 4 140.09 10 6.8821 5.00 5.5157 4.00 4.1494 4.00 2.7831 4.00 N/A 0.00 N/A 0.00 N/A 0.00 N/A 0.00 N/A 0.00 N/A 0.00 2.53 19,965.94 14.86 7,901.42

Pd Td D H G Sd C.A. q CAPt LARGO ANCHO AreaLE DENSIDAD

Thickness: Tapered Roof Sheets NLtecho= Number of Plates Required for Roof Ttecho = Minimum thickness of roof plate required INCHES Minimum thickness of roof plate required, mm Ttecho n = Nominal Thickness of Roof Plate, mm Vtt= Roof Tank volume, m3 Ptt= Roof Tank Weight, kg Thickness: Flat sheets NLpiso= Number Plates Wanted for Apartment Tpiso= Minimum thickness of flat sheet required INCHES Minimum thickness of sheet required Floor, mm Tpiso n = Flat Blade Thickness Nominal, mm Vpt= Tank Floor Volume, m3 Ppt= Tank Floor Weight, kg Totals: Volume= Total stored water volume, m3 In ft3 In gallons In barrels (U. S. Liquid) Total Weight = Vacuum Tank Total Weight, Kilograms Total weight of the tank filled with water, Kilograms Nominal Tank Capacity (Barrels) Nominal Tank Capacity (Gallons): Nominal Tank Capacity (Liters): Nominal Tank Capacity (mts3): Volume of Air in the tank (%): Tank Net Capacity (Barrels) Net Tank Capacity (Gallons): Net Tank Capacity (Liters): Net Capacity Tank (mts3):

18.00 0.35 9.02 6.35 1.70 13,424.16 18.00 0.31 7.94 10.00 2.68 21,140.41 2,562.34 90,476.20 676,970.02 21,491.11 54,530.51 2,616,869.73 16,117.17 676,921.19 2,562,146.71 2,562.15 2.50 15,714.24 659,998.16 2,498,093.04 2,498.09