Fenix Process Technologies Pvt. Ltd.

Description : Ethyl acetate (EA)-Water-Ethanol Separation System

Process Flow Diagram

COL1 DIST1 FEED COL2 DIST2

BOT1

BOT2

Process Description Ethyl acetate (EA), water and ethanol mixture is fed to first column and EA is removed in this column. Bottom product of first column is fed to second column to remove ethanol at azeotropic composition. The required ethanol purity is 94.5 % (wt). The typical feed condition is Ethyl Acetate Water Ethanol Operating Conditions Pressure : Both columns are operating under atmospheric pressure : 1-5 % (wt) : 45-55 % (wt) : 45-55% (wt)

Column Internals :Structured packing for first column (Type 2.5L) Wire mesh packing for second column (Type WM) Experience Fenix Process Technologies Pvt. Ltd. has supplied separating systems involving azeotropic distillation. EAWater-Ethanol is typical system involving EA-Water and Ethanol-Water azeotrope. The design involves prediction of azeotrope of EA-Water and Ethanol-Water.