Professional Documents
Culture Documents
OFC Power Point
OFC Power Point
BSNL
Chennai-600027
Email rgm_cttc@sancharnet.in
G. Shankar, Faculty, RGM TTC
RGM TTC
BSNL
RGM TTC
Objectives
BSNL
BSNL
Maintenance difficult
Vulnerable for EMI.
RGM TTC
BSNL
RGM TTC
BSNL
What is OFC ?
Fibre Optic cable functions as a
LIGHT GUIDE, guiding the light introduced at one end of the cable through to the other end.
RGM TTC
BSNL
Higher Security
RGM TTC
BSNL
OFC Applications
Telecommunication Network Junction Network & Long Distance Network Submarine cable High EMI areas
Explosive environment
Computer links & Local Area Network Cable television Medical Field , Automobile Field
RGM TTC
OFC Construction
BSNL
Construction of Fibre
Centre Core Glass More RI 8-10 micrometer
Light is transmitted through the core
Principle of Working
BSNL
TIR is achieved since Core and Cladding having different Refractive Indices. Core RI 1.48 Cladding RI 1.47
RGM TTC
BSNL
Construction of Cable
Fibres are placed inside the Buffers along with Jelly to prevent moisture entry.
Centre Strengthening Member GRP, FRP Loose Tube Buffers 2.4 mm Dia
RGM TTC
Construction of Cable
BSNL
Centre Strengthening Member GRP, FRP Loose Tube Buffers 2.4 mm Dia, Fibres are placed inside along with jelly. Primary Strength Member Aramid Yarn Inner Sheath Black Outer Nylon Sheath Orange
RGM TTC
BSNL
Construction Of Cable
BSNL
RGM TTC
These are tight Buffered cable Has only one fibre per cable Connector ended
BSNL
Parameters of Cabling
Tensile Strength ( Pull)
Crushing Resistance
Protection from Excess Bending
Abrasion Protection
Anti-Twist Chemical protection
RGM TTC
Specification Of OFC
BSNL
Fibre Core 8-10 Microns (Single Mode) 50 - 100Microns (Multimode) Cladding - 125 Microns (overall Dia) Attenuation - better than 0.5 db /KM Primary Coating 250 Microns UV cured Acrylate Secondary Coating 2.4 mm nylon PE Jelly filled tube Central Strength Member Fibre Reinforced Plastic (FRP) Moisture Barrier- non metallic polythylene sheet free from pinholes and other defects Polythene sheath Polythene free from pin holes
RGM TTC
Specification Of OFC
BSNL
Nylon Outer Sheath (0.7mm thickness)- Protective sheath against termite & partially against rodent Strength to withstand a load - 3X9.8 W Newtons, where W is weight of O/F cable per KM in Kg MAX Strain allowed in fibre - 0.25%
MAX attenuation variation - Permissible + 0.02 dB normal 20 degree centigrade to 60 degree centigrade
from
Flexibility Maximum bending radius allowed 24d, d is the diameter of OF cable Cable drum lengths - 2 KM +10% Cable ends - one end fitted with grip Other end sealed with cap
RGM TTC
BSNL
RGM TTC
BSNL
OFC types
Single Mode Fibre
Multi Mode Fibre
RGM TTC
Multimode
BSNL
Has a large Core Diameter Core Diameter - 50, 62.5, 100 Micro meter Cladding dia - 125 Micro meter
RGM TTC
BSNL
OFC Sizes
BSNL
6 Fibre
12 Fibre 24 Fibre 48 Fibre 96 Fibre
BSNL
OFC LAYING
1. 1Pulling Method
HDPE pipe laying ( High density Poly ethylene ) OFC Pulling
2. Blowing Method
BSNL
Specification of Trench
Depth 165CM
Top Width 45CM
BSNL
RGM TTC
Standard length of the pipe 5 M Diameter of the pipe - 50mm, 75mm, 110mm The work is taken up in sections of 200M and pipes are buried . Between two sections a gap of 2M is left known as intermediate manhole
RGM TTC
BSNL
End Caps
4mm Nylon Rope
- 2 Numbers
- one coil of 205 to 210M
RGM TTC
BSNL
RGM TTC
BSNL
At Road Crossings
RCC pipes should be used The RCC pipe should extend 3M on either side from the edge of the road.
BSNL
At Culverts / Bridges
Galvanised iron pipes are used on the wheel guard / footpath Gradual sloping to be given on either side of the bridge by reducing the depth of the trench to achieve the zero depth at bridges. For depths less than one meter, GI pipe should be provided and cement concreted.
BSNL
At Railway Crossing
BSNL
Use cable grip along with anti twist device while pulling the cable
RGM TTC
BSNL
RGM TTC
BSNL
RGM TTC
BSNL
1. Survey of Cable Route (Route PLG & SELECTION) 2. Testing of OFC in drums before laying
BSNL
RGM TTC
BSNL
Pipe Laying
HDPE pipes laid with couplings inserting 4mm Nylon rope inside the pipe. 9.Distance between the Intermediate Man Holes 200m
BSNL
BSNL
RGM TTC
BSNL
BLOWING METHOD
through pre prepared, pressurized, integral OFC ducts with the help of heavy air blowing pressure at 10 bar plus. The main driving force in the technology is blowing of air at high penetrating pressure.
RGM TTC
BSNL
BSNL
ADVANTAGES
tensile forces.
RGM TTC
BSNL
PLB-HDPE Ducts
Standard length - 200M, 1000M
Diameter - 32/26mm, 40/33mm, 50/42mm Couplers will be placed for jointing two lengths Nylon rope approximately 4mm dia is placed inside the ducts.
RGM TTC
BSNL
Duct Laying
RGM TTC
PREREQUISITE
BSNL
Duct integrity
Duct uniformity
RGM TTC
BSNL
Cable Blowing
Cable jet blowing machine with compressor is used Air is blown into the Duct at high pressure & distributed along the entire cable through Duct
The cable should be pushed from the blowing end to achieve more blowable length.
RGM TTC
Make: SWITZERLAND
Cable jet machine comes with appropriate spacers. These spacers range from 11 mm to 18.5 mm to suit different makes of OFC. The spacer suitable for sterlite 2001 make is 11 to12.5, 14-15.5 and 15-18.5.
RGM TTC
PROCEDURE
BSNL
section. Prepare stringent drum planning for entire route with ear marked below Points(B1, B2..etc,) Transport the ear marked drums to the specified below points and uncoil the drums into figure 8 formation.
RGM TTC
BSNL
Prepare the cable end suitable for blowing by adding a spacer heading bullet.
Place cable jet machine inside the blow pit and fix the top cover of the jet machine.
RGM TTC
PROCEDURE CONTD
BSNL
Insert sponge into the duct and fix the top cover
of the jet machine. Fix the air blowing hose pipe to the cable jet machine.
RGM TTC
BSNL
PROCEDURE CONTD
BSNL
Remove the jet machine and carefully normal the loop by lowering the duct. Tighten the coupler
RGM TTC
PRECAUTIONS
BSNL
Provisioning for extra cable length for bends and shrinkage of duct during drum planning.
Care to be taken while lowering the duct at the end of blowing operation. Personnel must be beware of high operating air pressures
RGM TTC
BSNL
RGM TTC
Factors Influencing
BSNL
Blowable length
BSNL
Blowing Chamber
Chambers are placed at a distance of one KM Size of the blowing chamber is 3M X 1MX 1.5M(LXWXD )
These are temporary chambers and refilled after accomplishing blowing operation
Average blowable length is 700M to 2000M depending upon the factors
RGM TTC
Cable Laying
RGM TTC
BSNL
RGM TTC
BSNL
THANK YOU
RGM TTC