You are on page 1of 1

16Nm3/h Onsite hydrogen production alkaline electrolysis

Main Features & Options Available


Water purification system 200L Purified water buffer storage tank Alkaline electrolysis system Integrated Hydrogen purification system o Deoxygenation to achieve up to 99.995% o o Drier to achieve up to -45 C average dew point Power conditioning and control Multipoint active hydrogen detection Integration into complete turn-key solution

TECHNOLOGY & SYSTEM LAYOUT


Hydrogen is produced using state of the art alkaline electrolysis of water to produce hydrogen & oxygen gases through the use of electricity. Equipment is provided with all necessary auxiliary items to provide safe reliable onsite hydrogen production

ELECTROLYSIS TECHNICAL SPECIFICATIONS


Maximum Hydrogen Production 16 Nm /hour Maximum Electricity consumption / supply 81 kW @ 400VAC 50Hz Transformer position Internal Control panel position Internal Production variation range 20% to 100% of maximum capacity Deionised water consumption at full power 13.6 litre/hour Hydrogen purity (before purifier) 99.3%-99.8% Outlet gas dew point (before drier) Saturated at ambient temperature Outlet gas Pressure up to 12 bar o Environment temperature range 5-35 C Valves actuation Pneumatic Cooling system Air or Liquid Dimensions (Length X Depth X Height) 1650 mm X 2400 mm X 2150 mm Weight 2450 kg Certification CE approved Additional Configuration Options Parallel connection of several units to increase production capacity remote surveillance control system through Internet full service contract compression & buffer storage allowing for flexible supply independent from production purchase of green electricity to eliminate CO2 emissions from the production process
3

Disclaimer: This Note is for advice only. Please note that legislation, guidance and practical methods are continually subject to change. Please take note of prevailing legislation and guidance, as amended, whether mentioned here or not. Where legislation and documents are summarised, this is for general advice and convenience, and must not be relied upon as a comprehensive or authoritative interpretation. It is the responsibility of the person/company involved in the assessment, development and operation of potential installations to ensure up to date working practices are applied to determine the status of a site and the requirements needed. Note: Technical specifications are subject to change

AN-005

Page 1 of 1