Climaveneta Technical Bulletin

NECS 0202T - 0612T_201606_EN HCF R410A


ELCA_Engine ver.3.4.0.1

NECS 0202T - 0612T


47,8-159 kW
Chiller, air source for outdoor installation

(The photo of the unit is indicative and may vary depending on the model)

EXCHANGER
MAXIMUM RELIABILITY
INTEGRATED HYDRONIC MODULE
CERTIFICATIONS

Product certifications

Voluntary product certifications

Check ongoing validity of certificate:


www.eurovent-certification.com
or
www.certiflash.com

System certifications

Climaveneta S.p.A.:

Quality System complying with the requirements of UNI EN ISO9001:2008 regulation

Environmental Management System complying with the requirements of UNI EN


ISO14001:2004 regulation
INDEX NECS 0202T - 0612T

1.1 PRODUCT PRESENTATION pg.1.1.1 / 1.1.3


2.1 UNIT STANDARD COMPOSITION pg.2.1.1 / 2.1.2
3.1 ACCESSORIES pg.3.1.1 / 3.1.3
4.1 GENERAL TECHNICAL DATA pg.4.1.1 / 4.1.4
5.1 OPERATING LIMITS pg.5.1.1 / 5.1.3
6.1 HYDRAULIC DATA pg.6.1.1 / 6.1.1
7.1 ELECTRICAL DATA pg.7.1.1 / 7.1.4
8.1 FULL LOAD SOUND LEVEL pg.8.1.1 / 8.1.4
9.1 DIMENSIONAL DRAWINGS pg.9.1.1 / 9.1.3
10.1 HYDRONIC GROUP pg.10.1.1 /
10.1.10

Liability disclaimer
The present publication is drawn up by of information only and does not constitute an offer binding upon Climaveneta.
Climaveneta has compiled the content of this publication to the best of its knowledge. The data contained herein are subject to change without
notice. Climaventa explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or
interpretation of this publication. All content is copyrighted by Climaveneta.

ELCA_Engine ver.3.4.0.1 NECS 0202T - 0612T_201606_EN HCF R410A


LEGEND CS

Functions

Cooling

Refrigerant

R-410A

Compressors

Scroll compressor

Fan

Axial fan

Exchangers

Shell & Tubes

Other features

Eurovent

ELCA_Engine ver.3.4.0.1 NECS 0202T - 0612T_201606_EN HCF R410A


1.1 PRODUCT PRESENTATION

2.1 GREEN CERTIFICATION RELEVANT

Climaveneta as a major player in the world HVAC market and a


leading manufacturer of energy efficient, sustainable HVAC solutions,
recognizes and supports the diffusion of green certification systems, as
an effective way to deliver high performance buildings and improve the
quality and the sustainability of the built environment.

Since the first certification system was introduced at the beginning of


the 1990s, the demand for certified buildings has grown considerably,
as well as the number of standards, rating and certification programs.
Operating worldwide Climaveneta has extensive experience with many
of them and is active member of Green Building Council Italy.

Climaveneta commitment to develop responsible and sustainable


HVAC solutions, is reflected by a full range of premium efficiency
products and systems, designed with special care to improve building
energy performance ratings, according to major certification protocols,
including LEED, BREAM, GREENSTAR, BCA, NABERS, DNGB, HQE
and BEAM.

To find out more about how our products contribute to enhanced green
certification rating and energy performance of a building, please refer
to:
http://www.climaveneta.com/GLOBAL/Company/Green-Certifications/
QR code

ELCA_Engine ver.3.4.0.1 1.1.1 NECS 0202T - 0612T_201606_EN HCF R410A


PRODUCT PRESENTATION

Outdoor unit for the production of chilled water with hermetic rotary Scroll
compressors, axialflow fans, shell and tubes exchanger and thermostatic
expansion valve. External panels in Peraluman and structure in
aluminium sections. The range is equipped with two compressors on two
independent refrigerant circuits.

1.3 EXCHANGER
The shell and tube exchanger allows to achieve the highest flexibility on
the unit’s installation, keeping on the hydronic side the pressure drops at
the minimum level, thus representing the best choice for all the hydronic
applications on the residential, commercial and industrial markets.

1.4 MAXIMUM RELIABILITY


Unit with two independent refrigerant circuit, designed to ensure
maximum efficiency at full load, ensuring uninterrupted operation even in
the event of temporary stop of one of the two circuits.

1.5 INTEGRATED HYDRONIC MODULE


The built-in hydronic module includes the main water circuit components;
it is available in various configurations with one or two pumps with high or
low head.

ELCA_Engine ver.3.4.0.1 1.1.3 NECS 0202T - 0612T_201606_EN HCF R410A


2.1 UNIT STANDARD COMPOSITION

2.2 Chiller, air source for outdoor installation - electronic controller


Outdoor unit for the production of chilled water with hermetic rotary Scroll - Power supply: 400V~ ±10% 3ph 50Hz + N
compressors, axialflow fans, shell and tubes exchanger and thermostatic
expansion valve. External panels in Peraluman and structure in 2.11 Certification and applicable directives
aluminium sections. The range is equipped with two compressors on two The unit complies with the following directives and relative amendments:
independent refrigerant circuits. - EUROVENT Certification program
- The unit is supplied fully refrigerant charged and factory tested. On site - CE Declaration of conformity certificate for the European Union
- EAC Product quality certificate for Russian Federation
installation only requires power and hydraulic connection. - Machine directive 2006/42/EC
- ElectroMagnetic compatibility directive 89/336/EEC + 2004/108/EC
2.3 Structure - Low Voltage directive 2006/95/EC
Frame in polyester-painted galvanized steel. The self-supporting frame is - PED Directive 2014/68/EC
built to guarantee maximum accessibility for servicing and maintenance - ISO 9001 Company´s Quality Management System certification
operations. - ISO 14001 Company´s Environmental Management System
- Compressors fastened to unit's frame with ani-vibration mountings. certification
- Compressor compartment separated from ventilation section.
- Compressor compartment with soundproofing anclosure (thickness of 2.12 Tests
30 mm on sides and on top) (versions LN, SL). Tests performed throughout the production process, as indicated in
ISO9001.
2.4 Panelling Performance or noise tests can be performed by highly qualified staff in
Specific panelling for outdoor installation in aluminium alloy which
the presence of customers.
ensures total resistance to atmospheric agents, easily removable, made
Performance tests comprise the measurement of:
in such a way as to allow total access to the internal components to
- electrical data
facilitate inspection and maintenance work.
- water flow rates
2.5 Compressor - working temperatures
Hermetic scroll compressors complete with an oil sump heater, electronic - power input
overheating protection with centralised manual reset and a two-pole - power output
electric motor. - pressure drops on the water-side exchanger both at full load (at the
conditions of selection and at the most critical conditions for the
2.6 Plant side heat exchanger condenser) and at part load conditions.
Direct expansion multi-circuit shell and tube exchanger with asymmetric During performance testing it is also possible to simulate the main alarm
side coolant flows for maintaining the coolant at the correct speed inside states.
the tubes when passing from the liquid to the gas phase. The shell & tube Noise tests are performed to check noise emissions according to
is manufactured using copper tubes with internal grooves for favouring ISO9614.
heat exchange and mechanically expanded onto the tube plates. The
heat exchanger may be inspected to facilitate cleaning operations when
using particularly hard water (limestone). The heat exchanger is lined on 2.13 Electronic control W3000
the outside with 9 mm thick closed-cell neoprene lagging to prevent The W3000 controller offers advanced functions and algorithms.
condensation, with a thermal conductivity of 0,33 W/mK at 0°C. The heat The Base keyboard features an easy-to-use interface that allows
exchanger is fitted with a differential pressure switch to monitor the consulting and intervening on the unit by means of a multi-level menu.
correct flow of water when the unit is operating, thus preventing ice form The Compact keyboard (optional) has a complete LCD display with an
forming inside. An electric antifreeze heater prevents the ice from forming interface available in three languages: Italian, English and a further
inside the exchanger when the unit is not working but connected to the language among French, Spanish, German, Russian and Swedish. The
electrical supply. alarm history display function can be enable by installing a real-time clock
(optional) (only with Compact keyboard).
2.7 Source side heat exchanger
Finned coil exchanger made by copper tubes mechanically bounded to The regulation is based on the patented “Quickmind” water temperature
aluminium fins. The aluminium fins are correctly spaced to guarantee regulation logic uses self-adapting control to maintain flow temperatures
optimum heat exchange efficiency. and optimise performance even in low water content scenarios. As an
alternative, the proportional or proportional-integral regulations are also
2.8 Fan section source side available.
Axial electric fans, protected to IP 54, with external rotor and Optional proprietary devices can perform the adjustment of the resources
plastic-coated aluminium blades. Housed in aerodynamic hoods complete in systems made of several units. Consumption metering and
with safety grille. 4-pole electric motor with built-in overload protection. performance measurement are possible as well.
Fan diameter of 450 mm. Separated ventilation control with inactive circuit Supervision can be easily developed via proprietary devices or the
fan disabling. Fan speed adjusted by phase-cut devices. integration in third party systems by means of the most common protocols
as ModBus, Bacnet, LonWorks.
2.9 Refrigerant circuit Compatibility with the remote keyboard (up to 8 units) (only with Compact
Main components of the cooling circuit: keyboard).
- two independent circuits The defrosting (air source reversible unit only) follows a proprietary
- R410A refrigerant self-adaptive logic, which features the monitoring of several operational
- shell and tube exchanger
- drier filter with replaceable cartridge parameters. This allows to reduce the number and duration of the defrost
- refrigerant line sight glass with humidity indicator cycles, with a benefit for the overall energy efficiency.
- mechanical thermostatic expansion valves
- high and low pressure transducers
- high and low pressure safety valve
- safety switching device for limiting the pressure
- crankcase heater on each compressor

2.10 Electrical and control panel


Electrical and control panel built to EN60204-1 and EC204-1 standards,
complete with:
- general door lock isolator
- control circuit transformer
- IP44 XW protection
- numbered cables
- electric circuit breakers for compressors and fans
- remote ON/OFF terminals
- terminals for cumulative alarm block
- relays for remote pump(s) activation for both circuits (only for units
without hydronic pumps)
- antifreeze electric heater for heat exchanger
2.14 Versions

ELCA_Engine ver.3.4.0.1 2.1.1 NECS 0202T - 0612T_201606_EN HCF R410A


2.14 UNIT STANDARD COMPOSITION

/B – Basic version
Standard unit

/LN - Low Noise


This configuration features a special soundproofing for the compressor
compartment and the pumps (if present), a reduced fan speed and an
oversized condensing section.
The fan speed is automatically increased in case of particularly tough
environmental conditions.

/SL - Super Low noise


This configuration features a special soundproofing for the compressor
compartment and the pumps (if present), a reduced fan speed and an
oversized condensing section.
The fan speed is automatically increased in case of particularly tough
environmental conditions.

/HT - High efficiency, High outdoor Temperature


Version suitable for operation with high air temperatures at the condeser
inlet.
This version features an oversized condensing section in order to ensure
that heat is correctly exchanged even in particularly tough environmental
conditions. As a result, when working at normal air temperatures, an
increase in cooling capacity and a decrease in power input is obtained,
hence improving the cooling efficiency ratio (EER).

2.15 Configurations
< >, Standard unit
Standard unit for production of chilled water

ELCA_Engine ver.3.4.0.1 2.1.2 NECS 0202T - 0612T_201606_EN HCF R410A


3.1 ACCESSORIES

ACCESSORIES DESCRIPTIONS BENEFITS AVAILABLE FOR MODELS


PF410
ANTI-VIBRANT MOUNTINGS KIT (RUBBER ISOLATORS)
F4005030 For the correct match between ALL
Anti-Vibration mountings unit model and anti-vibration
Kit (rubber isolators) mounting kit please refer to the
price list
F4005040 For the correct match between ALL
Anti-Vibration mountings unit model and anti-vibration
Kit (rubber isolators) mounting kit please refer to the
price list
PF417
LIFTINGS SPREAD BAR
F4005292 ALL
Lifting bars
380
NUMBERED WIRING
381 ALL
NUMBERED WIRING ON
EL. BOARD
2410
PHASE SEQUENCE RELAY
2411 Relay for checking mains Protects loads against faults due ALL
WITH EXTERNAL PHASE phase-sequence to incorrect connection of mains
SEQUENCE RELAY
3410
AUTOMATIC CIRCUIT BREAKERS
3412 Over-current switch on the major In case of overcurrent allows ALL
AUTOM. CIRCUIT electrical loads. resetting of the switch without the
BREAK. ON LOADS replacement of relative fuses.
3600
ON/OFF COMPRESSOR SIGNAL
3601 Auxiliary contacts providing a Allows remote signalling of ALL
COMPRESSOR voltage-free signal. compressor's activation or remote
OPERATION SIGNAL control of any auxiliary loads.
4180
REMOTE CONNECTION ARRANGEMENT
4181 Interface module for ModBUS Allows integration with BMS ALL
SERIAL CARD MODBUS protocols. operating with ModBUS protocol.
4182 Interface module for Echelon Allows integration with BMS ALL
SERIAL CARD FOR systems. operating with LonWorks
LONWORKS protocols
4184 Interface module for BACnet Allows integration with BMS ALL
SERIAL CARD BACNET protocols. operating with BACnet protocol.
MS/TP RS485
6160
AUXILIARY INPUT
6163 4-20 mA analog input + demand The 4-20 mA analog input allows ALL
AUX 4-20mA REMOTE D limit remote input to change the operating set-point
L.C. according to the value of current
applied to the analogue input. The
demand limit remote input permits
to limit the unit's power absorption
for safety reasons
6190
TYPE OF VISUAL DISPLAY
6192 Keyboard with LCD display Features a multi-language menu ALL
W3000 COMPACT (with the W3000 software there
VISUAL DISPLAY are 3 languages available).
Allows the connection of the
remote keyboard.
When equipped with a real time
clock (optional), enables the alarm
history display function.

ELCA_Engine ver.3.4.0.1 3.1.1 NECS 0202T - 0612T_201606_EN HCF R410A


ACCESSORIES

ACCESSORIES DESCRIPTIONS BENEFITS AVAILABLE FOR MODELS


1510
SOFT-STARTER
1511 Electronic device adopted to Break down of the inrush current ALL
SOFT-STARTER FOR manage the inrush current. compared to the direct motor
THREE-PHASE POWER start, lower motor windings’
SUPPLY mechanical wear, avoidance of
mains voltage fluctuations during
starting, favourable sizing for the
electrical system.
1400
HP AND LP GAUGES
1401 High and low pressure gauges Allows immediate reading of the ALL
HP AND LP GAUGES pressure values on both low and
high pressure circuits
1900
COMPRESSOR SUCTION VALVE
1901 Shut-off valve on compressor's Simplifies maintenance activities ALL
COMPRESSOR SUCTION suction circuit.
VALVE
1910
COMPRESSOR DISCHARGE VALVE
1911 Shut-off solenoid valve on Simplifies maintenance activities ALL
COMPR. DISCHARGE compressor discharge circuit
LINE VALVE
890
CONDENSING COIL
881 Finned coil heat exchanger made Provide a very high resistance ALL
Cu/Cu EXTERNAL COIL from copper tubes and aluminum against corrosion, also in very
fins with chemical cleaning aggressive environment.
treatment to remove impurities, For further information please
and then coated with protective refer to the Guidelines “Finned
paint with the following coil heat exchangers and
characteristics: protection against corrosion”,
- fins treated with protective available in the download section
polyester resin paint; of the website
- over 1000 hours of salt spray www.climaveneta.com, or contact
protection as per ASTM B117 our sales department.
(fins without cross and protected
edges);
- excellent resistance to UV rays.
894 Finned coil heat exchanger made Provide a good resistance against ALL
Cu PIPES/PREPAINTED from copper tubes and aluminum corrosion.
ALL. FINS fins with chemical cleaning For further information please
treatment to remove impurities, refer to the Guidelines “Finned
and then coated with protective coil heat exchangers and
paint with the following protection against corrosion”,
characteristics: available in the download section
- fins treated with protective of the website
polyester resin paint; www.climaveneta.com, or contact
- over 1000 hours of salt spray our sales department.
protection as per ASTM B117
(fins without cross and protected
edges);
- excellent resistance to UV rays.
895 Copper-aluminum heat exchanger Provide a very high resistance ALL
FIN GUARD SILVER coils with polyurethane paint Fin against corrosion, also in very
TREATM Guard Silver SB. Coil completely aggressive environment.
coated by a protective layer of For further information please
polyurethane paint with the refer to the Guidelines “Finned
following characteristics: coil heat exchangers and
- polyurethane paint with metallic protection against corrosion”,
emulsion; available in the download section
- over 3000 hours of salt spray of the website
protection as per ASTM B117; www.climaveneta.com, or contact
- excellent resistance to UV rays; our sales department.
- high-pressure spray painting
system.

ELCA_Engine ver.3.4.0.1 3.1.2 NECS 0202T - 0612T_201606_EN HCF R410A


ACCESSORIES
ACCESSORIES DESCRIPTIONS BENEFITS AVAILABLE FOR MODELS
2030
PROTECTION GRILL
2032 Covering metal net on the coil Finned coil protection ALL
COND. COIL
PROTECTION NET
820
LOW AMBIENT CONTROL
802 Fan speed control according to Extension of the unit operating ALL
VAR.FAN SPEED LOW the condensing pressure; the use range (see the section dedicated
AMB.CONTROL of this device is mandatory in to the operating limits). The
case the unit operates with low device allows the unit to operate
evaporator leaving water in the most extreme conditions
temperature combined with low avoiding any risk of low pressure
outdoor air temperatures alarm intervention. The enhanced
air flow management delivers also
benefits in terms of both efficiency
and quietness.
3330
HYDRONIC GROUP
3342 Hydronic group (see dedicated ALL
KIT 1 CENTRIF. PUMP 2P section).
L.H.
3343 Hydronic group (see dedicated ALL
KIT 1 CENTRIF. PUMP 2P section).
H.H.
3345 Hydronic group (see dedicated ALL
KIT 2 CENTRIF. PUMPS section).
2P L.H.
3346 Hydronic group (see dedicated ALL
KIT 2 CENTRIF. PUMPS section).
2P H.H.
2620
ACOUSTICAL ENCLOSURE
2621 Increased soundproofing Noise emission reduction of 4 ALL
EXTRA INSUL.ON enclosure for compressor section dB(A)
COMPR. SECTION
9970
PACKING
9968 Unit provided plastic supports, ALL
NYLON, SUPP., COIL with polypropylene panels for coils
PROT. PACK. protection and covered with nylon
9972 Unit provided with wooden box ALL
WOODEN BOX PACKING
9973 Unit provided with wooden cage ALL
WOODEN CAGE
PACKING
9974 Unit provided with barrier bag and ALL
MARINE PACKING wooden cage
9977 Unit provided plastic supports and ALL
SUPPORTS + COILS covered with nylon
PROTECTION
9979 Unit provided with container slides ALL
CONTAINER PACKING and covered with nylon
PF0
Generic accessory
C5140131 Flow switch with stainless Signaling of lack of or excessi- NX /K: 0614P, 0714P, 0814P, 0914P.
Evaporator water flow scoop AISI 316L and IP65 ve reduction of fl ow, it genera- NX /LN-K: 0614P, 0714P, 0814P,
protection suitable for installa- tes an alarm that is in automa- 0914P.
switch tion in industrial plant pipes. It tic or manual reset depending NX /SL-K: 0614P, 0714P, 0814P, 0914P.
should be installed in a straight on n ° alarms per hour and NX / D /K: 0614P, 0714P, 0814P, 0914P.
pipe without fi lters, valves, the maximum time of operation NX / D /LN-K: 0614P, 0714P, 0814P,
etc., long at least 5 times its of the pump under conditions 0914P.
diameter, both upstream and of low fl ow rate. NX / D /SL-K: 0614P, 0714P, 0814P,
downstream. 0914P.
ADVANTAGES: signaling of
lack of or
ACCESSORY NOTES
381 – Numbered wiring on electrical board 3412 – Automatic circuit breakers
Standard feature Standard feature

ELCA_Engine ver.3.4.0.1 3.1.3 NECS 0202T - 0612T_201606_EN HCF R410A


4.1 GENERAL TECHNICAL DATA NECS / B
[ SI System ]

NECS / B 0202T 0252T 0302T 0352T 0412T 0452T 0512T 0552T 0612T
Power supply V/ph/Hz - - - - - - - - -
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 53,0 58,1 76,0 86,8 96,9 112 127 145 159
Total power input (1) kW 18,3 21,5 27,8 31,9 36,3 39,7 43,7 50,2 58,6
EER (1) kW/kW 2,90 2,70 2,73 2,72 2,67 2,83 2,90 2,89 2,71
ESEER (1) kW/kW 3,72 3,47 3,52 3,49 3,41 3,59 3,65 3,66 3,44
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 52,9 58,0 75,8 86,5 96,7 112 126 144 158
EER (1)(2) kW/kW 2,88 2,68 2,71 2,69 2,65 2,80 2,87 2,85 2,67
ESEER (1)(2) kW/kW 3,68 3,41 3,45 3,40 3,36 3,51 3,59 3,58 3,37
Cooling energy class C D C D D C C C D
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 2,54 2,78 3,63 4,15 4,63 5,37 6,06 6,93 7,58
Pressure drop (1) kPa 6,25 7,64 13,1 17,2 12,8 17,2 15,7 21,7 25,9
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2 2 2 2 2 2 2 2
Number of capacity N° 2 2 2 2 2 2 2 2 2
No. Circuits N° 2 2 2 2 2 2 2 2 2
Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS
Min. capacity step % 50 50 50 50 50 50 50 50 50
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant charge kg 10 10 13 14 16 18 21 25 23
Oil charge kg 6 6 6 8 9 11 14 13 13
Rc (ASHRAE) (3) kg/kW 0,196 0,179 0,167 0,159 0,169 0,160 0,170 0,175 0,146
FANS
Quantity N° 6 6 6 6 6 8 10 10 10
Air flow m³/s 7,92 7,92 7,63 7,35 7,85 9,88 13,09 12,77 12,77
Fans power input kW 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25
NOISE LEVEL
Noise Pressure (4) dB(A) 53 53 53 54 54 54 55 55 55
Sound power level in cooling (5)(6) dB(A) 85 85 85 86 86 86 87 87 87
SIZE AND WEIGHT
A (7) mm 2195 2195 2195 2195 2745 2745 3245 3245 3245
B (7) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120
H (7) mm 1465 1465 1465 1465 1465 1465 1665 1665 1665
Operating weight (7) kg 625 625 665 765 920 990 1135 1180 1155

Notes:
1 Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511-3:2013.
3 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
4 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
5 Sound power on the basis of measurements made in compliance with ISO 9614.
6 Sound power level in cooling, outdoors.
7 Unit in standard configuration/execution, without optional accessories.
- Unavailable
Certified data in EUROVENT

ELCA_Engine ver.3.4.0.1 4.1.1 NECS 0202T - 0612T_201606_EN HCF R410A


GENERAL TECHNICAL DATA NECS / LN
[ SI System ]

NECS / LN 0202T 0252T 0302T 0352T 0412T 0452T 0512T 0552T 0612T
Power supply V/ph/Hz - - - - - - - - -
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 50,7 57,6 74,2 84,4 96,4 109 122 139 151
Total power input (1) kW 18,9 21,2 28,6 33,7 37,1 41,4 45,9 53,1 62,4
EER (1) kW/kW 2,68 2,72 2,59 2,50 2,60 2,63 2,66 2,61 2,42
ESEER (1) kW/kW 3,50 3,51 3,37 3,22 3,33 3,36 3,38 3,34 3,11
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 50,6 57,5 74,0 84,2 96,2 108 122 138 150
EER (1)(2) kW/kW 2,67 2,70 2,57 2,48 2,58 2,60 2,64 2,59 2,39
ESEER (1)(2) kW/kW 3,46 3,46 3,30 3,17 3,27 3,30 3,32 3,28 3,04
Cooling energy class D C D E D D D D E
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 2,42 2,75 3,55 4,04 4,61 5,20 5,83 6,64 7,21
Pressure drop (1) kPa 5,70 7,50 12,5 16,3 12,7 16,2 14,6 19,9 23,5
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2 2 2 2 2 2 2 2
Number of capacity N° 2 2 2 2 2 2 2 2 2
No. Circuits N° 2 2 2 2 2 2 2 2 2
Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS
Min. capacity step % 50 50 50 50 50 50 50 50 50
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant charge kg 10 13 12 15 18 20 21 25 23
Oil charge kg 6 6 6 8 9 11 14 13 13
Rc (ASHRAE) (3) kg/kW 0,205 0,221 0,162 0,177 0,186 0,182 0,177 0,182 0,153
FANS
Quantity N° 6 6 8 8 8 8 10 10 10
Air flow m³/s 6,04 5,73 8,16 9,03 8,77 8,55 10,96 10,69 10,69
Fans power input kW 0,16 0,16 0,16 0,25 0,25 0,25 0,25 0,25 0,25
NOISE LEVEL
Noise Pressure (4) dB(A) 48 48 49 51 51 51 52 52 52
Sound power level in cooling (5)(6) dB(A) 80 80 81 83 83 83 84 84 84
SIZE AND WEIGHT
A (7) mm 2195 2195 2745 2745 2745 2745 3245 3245 3245
B (7) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120
H (7) mm 1465 1465 1465 1665 1665 1665 1665 1665 1665
Operating weight (7) kg 625 650 715 840 965 1025 1135 1180 1155

Notes:
1 Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511-3:2013.
3 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
4 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
5 Sound power on the basis of measurements made in compliance with ISO 9614.
6 Sound power level in cooling, outdoors.
7 Unit in standard configuration/execution, without optional accessories.
- Unavailable
Certified data in EUROVENT

ELCA_Engine ver.3.4.0.1 4.1.2 NECS 0202T - 0612T_201606_EN HCF R410A


GENERAL TECHNICAL DATA NECS / SL
[ SI System ]

NECS / SL 0202T 0252T 0302T 0352T 0412T 0452T 0512T


Power supply V/ph/Hz - - - - - - -
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 47,8 55,5 69,9 85,4 96,8 106 117
Total power input (1) kW 20,3 22,6 30,9 33,6 37,3 43,2 48,1
EER (1) kW/kW 2,35 2,46 2,26 2,54 2,60 2,46 2,44
ESEER (1) kW/kW 3,13 3,19 3,00 3,25 3,30 3,14 3,14
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 47,7 55,4 69,7 85,2 96,6 106 117
EER (1)(2) kW/kW 2,34 2,44 2,25 2,52 2,57 2,43 2,42
ESEER (1)(2) kW/kW 3,09 3,14 2,93 3,19 3,25 3,09 3,09
Cooling energy class E E F D D E E
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 2,29 2,65 3,34 4,08 4,63 5,07 5,62
Pressure drop (1) kPa 5,08 6,95 11,1 16,7 12,8 15,4 13,5
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2 2 2 2 2 2
Number of capacity N° 2 2 2 2 2 2 2
No. Circuits N° 2 2 2 2 2 2 2
Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS
Min. capacity step % 50 50 50 50 50 50 50
Refrigerant R410A R410A R410A R410A R410A R410A R410A
Refrigerant charge kg 13 12 15 17 21 21 21
Oil charge kg 6 6 6 8 9 11 14
Rc (ASHRAE) (3) kg/kW 0,266 0,216 0,215 0,201 0,214 0,195 0,184
FANS
Quantity N° 6 8 8 10 10 10 10
Air flow m³/s 3,98 5,73 5,42 9,03 8,81 8,81 8,59
Fans power input kW 0,16 0,16 0,16 0,25 0,25 0,25 0,25
NOISE LEVEL
Noise Pressure (4) dB(A) 45 46 46 49 49 49 50
Sound power level in cooling (5)(6) dB(A) 77 78 78 81 81 81 82
SIZE AND WEIGHT
A (7) mm 2195 2745 2745 3245 3245 3245 3245
B (7) mm 1100 1100 1100 1100 1100 1100 1100
H (7) mm 1465 1465 1465 1665 1665 1665 1665
Operating weight (7) kg 650 700 750 915 1050 1075 1115

Notes:
1 Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511-3:2013.
3 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
4 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
5 Sound power on the basis of measurements made in compliance with ISO 9614.
6 Sound power level in cooling, outdoors.
7 Unit in standard configuration/execution, without optional accessories.
- Unavailable
Certified data in EUROVENT

ELCA_Engine ver.3.4.0.1 4.1.3 NECS 0202T - 0612T_201606_EN HCF R410A


GENERAL TECHNICAL DATA NECS / HT
[ SI System ]

NECS / HT 0202T 0252T 0302T 0352T 0412T 0452T 0512T


Power supply V/ph/Hz - - - - - - -
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 55,0 61,6 80,6 91,4 104 116 130
Total power input (1) kW 17,3 20,3 25,9 30,5 33,7 38,6 42,2
EER (1) kW/kW 3,18 3,03 3,11 3,00 3,09 3,00 3,08
ESEER (1) kW/kW 4,07 3,81 3,93 3,76 3,87 3,76 3,86
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 54,9 61,5 80,4 91,1 104 115 130
EER (1)(2) kW/kW 3,16 3,01 3,08 2,96 3,06 2,96 3,05
ESEER (1)(2) kW/kW 3,99 3,75 3,85 3,67 3,78 3,69 3,79
Cooling energy class A B B B B B B
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 2,63 2,94 3,86 4,37 4,99 5,53 6,21
Pressure drop (1) kPa 6,72 8,58 14,7 19,1 14,9 18,3 16,5
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2 2 2 2 2 2
Number of capacity N° 2 2 2 2 2 2 2
No. Circuits N° 2 2 2 2 2 2 2
Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS
Min. capacity step % 50 50 50 50 50 50 50
Refrigerant R410A R410A R410A R410A R410A R410A R410A
Refrigerant charge kg 13 12 15 17 21 21 21
Oil charge kg 6 6 6 8 9 11 14
Rc (ASHRAE) (3) kg/kW 0,231 0,195 0,186 0,188 0,198 0,179 0,166
FANS
Quantity N° 6 8 8 10 10 10 10
Air flow m³/s 7,63 10,60 10,22 13,46 13,09 13,09 12,77
Fans power input kW 0,25 0,25 0,25 0,25 0,25 0,25 0,25
NOISE LEVEL
Noise Pressure (4) dB(A) 53 54 54 55 55 55 55
Sound power level in cooling (5)(6) dB(A) 85 86 86 87 87 87 87
SIZE AND WEIGHT
A (7) mm 2195 2745 2745 3245 3245 3245 3245
B (7) mm 1120 1120 1120 1120 1120 1120 1120
H (7) mm 1465 1465 1465 1665 1665 1665 1665
Operating weight (7) kg 650 700 750 915 1050 1075 1115

Notes:
1 Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511-3:2013.
3 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
4 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
5 Sound power on the basis of measurements made in compliance with ISO 9614.
6 Sound power level in cooling, outdoors.
7 Unit in standard configuration/execution, without optional accessories.
- Unavailable
Certified data in EUROVENT

ELCA_Engine ver.3.4.0.1 4.1.4 NECS 0202T - 0612T_201606_EN HCF R410A


5.1 OPERATING LIMITS

(* if present)

ELCA_Engine ver.3.4.0.1 5.1.1 NECS 0202T - 0612T_201606_EN HCF R410A


OPERATING LIMITS NECS 0202T - 0612T

SIZE
NECS /B 0202T
NECS /B 0252T
NECS /B 0302T
NECS /B 0352T
NECS /B 0412T
NECS /B 0452T
NECS /B 0512T
NECS /B 0552T
NECS /B 0612T
NECS /LN 0202T
NECS /LN 0252T
NECS /LN 0302T
NECS /LN 0352T
NECS /LN 0412T
NECS /LN 0452T
NECS /LN 0512T
NECS /LN 0552T
NECS /LN 0612T
NECS /SL 0202T
NECS /SL 0252T
NECS /SL 0302T
NECS /SL 0352T
NECS /SL 0412T
NECS /SL 0452T
NECS /SL 0512T
NECS /HT 0202T
NECS /HT 0252T
NECS /HT 0302T
NECS /HT 0352T
NECS /HT 0412T
NECS /HT 0452T
NECS /HT 0512T

ELCA_Engine ver.3.4.0.1 5.1.2 NECS 0202T - 0612T_201606_EN HCF R410A


OPERATING LIMITS NECS 0202T - 0612T

5.2 ETHYLENE GLYCOL MIXTURE


Ethylene glycol and water mixture, used as a heat-conveying fluid, cause a variation in unit performance. For correct data, use the factors
indicated in the following tabel.
Freezing point (°C)
0 -5 -10 -15 -20 -25 -30 -35
Ethylene glycol percentage by weight
0% 12% 20% 30% 35% 40% 45% 50%
cPf 1 0,985 0,98 0,974 0,97 0,965 0,964 0,96
cQ 1 1,02 1,04 1,075 1,11 1,14 1,17 1,2
cdp 1 1,07 1,11 1,18 1,22 1,24 1,27 1,3

cPf: cooling power correction factor For data concerning other kind of anti-freeze solutions (e,g, propylene
cQ: flow correction factor glycol) please contact our Sale Department.
cdp: pressure drop correction factor

5.3 FOULING FACTORS


Performances are based on clean condition of tubes (fouling factor = 1). For different fouling values, performance should be adjusted using the
correction factors shown in the following table.
FOULING FACTORS EVAPORATOR CONDENSER/RECOVERY DESUPERHEATER
SERIES ff KE KC
F1 FK1 F2 FK2 R3
(m² °CW) [°C] [°C]
VARIOUS 0 1,000 1,000 0,0 1,000 1,000 0,0 1,000
VARIOUS 1,80 x 10 -5 1,000 1,000 0,0 1,000 1,000 0,0 1,000
VARIOUS 4,40 x 10 -5
1,000 1,000 0,0 0,990 1,030 1,0 0,990
VARIOUS 8,80 x 10 -5 0,960 0,990 0,7 0,980 1,040 1,5 0,980
VARIOUS 13,20 x 10 -5 0,944 0,985 1,0 0,964 1,050 2,3 0,964
VARIOUS 17,20 x 10 -5
0,930 0,980 1,5 0,950 1,060 3,0 0,950

ff: fouling factors


F1 - F2: potential correction factors
FK1 - FK2: compressor power input correction factors
R3: capacity correction factors
KE: minimum evaporator outlet temperature increase
KC: maximum condenser outlet temperature decrease

ELCA_Engine ver.3.4.0.1 5.1.3 NECS 0202T - 0612T_201606_EN HCF R410A


6.1 HYDRAULIC DATA
[ SI System ]
Water flow and pressure drop
Water flow in the plant (side) exchanger is given by:
Q=P/(4,186 x Dt)
Q: water flow (l/s)
Dt: difference between inlet and outlet water temp. (°C)
P: heat exchanger capacity (kW)

Pressure drop is given by:


Dp= K x (3,6 x Q)^2/1000
Q: water flow (l/s)
Dp: pressure drop (kPa)
K: unit size ratio
HEAT EXCHANGER USER SIDE
Power
SIZE supply Q min Q max C.A.S. C.a. min
V/ph/Hz K
l/s l/s l l

NECS /B 0202T - 75,0 2,08 4,25 - 130


NECS /B 0252T - 76,3 2,19 4,67 - 150
NECS /B 0302T - 76,5 2,25 6,08 - 190
NECS /B 0352T - 77,1 2,56 6,94 - 220
NECS /B 0412T - 46,1 3,56 7,75 - 240
NECS /B 0452T - 46,1 3,56 8,97 - 280
NECS /B 0512T - 33,1 3,75 10,1 - 320
NECS /B 0552T - 34,9 4,31 11,6 - 360
NECS /B 0612T - 34,8 4,69 12,7 - 400
NECS /LN 0202T - 75,0 2,08 4,25 - 130
NECS /LN 0252T - 76,3 2,19 4,67 - 150
NECS /LN 0302T - 76,5 2,25 6,08 - 190
NECS /LN 0352T - 77,1 2,56 6,94 - 220
NECS /LN 0412T - 46,1 3,56 7,75 - 240
NECS /LN 0452T - 46,1 3,56 8,97 - 280
NECS /LN 0512T - 33,1 3,75 10,1 - 320
NECS /LN 0552T - 34,9 4,31 11,6 - 360
NECS /LN 0612T - 34,8 4,69 12,7 - 400
NECS /SL 0202T - 75,0 2,08 4,25 - 130
NECS /SL 0252T - 76,3 2,19 4,67 - 150
NECS /SL 0302T - 76,5 2,25 6,08 - 190
NECS /SL 0352T - 77,1 2,56 6,94 - 220
NECS /SL 0412T - 46,1 3,56 7,75 - 240
NECS /SL 0452T - 46,1 3,56 8,97 - 280
NECS /SL 0512T - 33,1 3,75 10,1 - 320
NECS /HT 0202T - 75,0 2,08 4,25 - 130
NECS /HT 0252T - 76,3 2,19 4,67 - 150
NECS /HT 0302T - 76,5 2,25 6,08 - 190
NECS /HT 0352T - 77,1 2,56 6,94 - 220
NECS /HT 0412T - 46,1 3,56 7,75 - 240
NECS /HT 0452T - 46,1 3,56 8,97 - 280
NECS /HT 0512T - 33,1 3,75 10,1 - 320

Q min: minimum water flow admitted to the heat exchanger


Q max: maximum water flow admitted to the heat exchanger
C.a. min: minimum water content admitted in the plant
C.A.S.: Exchanger water content

ELCA_Engine ver.3.4.0.1 6.1.1 NECS 0202T - 0612T_201606_EN HCF R410A


7.1 ELECTRICAL DATA NECS / B
[ SI System ]

Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202T - 2 2x11.8 2x20.4 2x118 0,25 1 25,1 47 145
0252T - 2 2x13.2 2x22.6 2x118 0,25 1 27,9 52 147
0302T - 2 2x17 2x30.5 2x173 0,25 1 35,5 68 210
0352T - 2 17+22.3 30.5+36.1 173+225 0,25 1 40,8 73 262
0412T - 2 2x22.3 2x36.1 2x225 0,25 1 46,1 79 268
0452T - 2 22.3+27.4 36.1+45.8 225+272 0,25 1 51,7 91 317
0512T - 2 2x27.4 2x45.8 2x272 0,25 1 57,3 103 329
0552T - 2 27.4+35.8 45.8+58.9 272+310 0,25 1 65,7 116 367
0612T - 2 2x35.8 2x58.9 2x310 0,25 1 74,1 129 380

F.L.I.: Full load power


F.L.A.: Full load current
L.R.A.: Locked rotor amperes for single compressor
S.A.: Inrush current

(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections

Electrical data valid for standard units without any additional option

Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.

Voltage tolerance: 10%


Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

ELCA_Engine ver.3.4.0.1 7.1.1 NECS 0202T - 0612T_201606_EN HCF R410A


ELECTRICAL DATA NECS / LN
[ SI System ]

Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202T - 2 2x11.8 2x20.4 2x118 0,16 1 24,6 45 143
0252T - 2 2x13.2 2x22.6 2x118 0,16 1 27,4 49 145
0302T - 2 2x17 2x30.5 2x173 0,16 1 35,3 67 209
0352T - 2 17+22.3 30.5+36.1 173+225 0,25 1 41,3 75 264
0412T - 2 2x22.3 2x36.1 2x225 0,25 1 46,6 81 270
0452T - 2 22.3+27.4 36.1+45.8 225+272 0,25 1 51,7 91 317
0512T - 2 2x27.4 2x45.8 2x272 0,25 1 57,3 103 329
0552T - 2 27.4+35.8 45.8+58.9 272+310 0,25 1 65,7 116 367
0612T - 2 2x35.8 2x58.9 2x310 0,25 1 74,1 129 380

F.L.I.: Full load power


F.L.A.: Full load current
L.R.A.: Locked rotor amperes for single compressor
S.A.: Inrush current

(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections

Electrical data valid for standard units without any additional option

Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.

Voltage tolerance: 10%


Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

ELCA_Engine ver.3.4.0.1 7.1.2 NECS 0202T - 0612T_201606_EN HCF R410A


ELECTRICAL DATA NECS / SL
[ SI System ]

Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202T - 2 2x11.8 2x20.4 2x118 0,16 1 24,6 45 143
0252T - 2 2x13.2 2x22.6 2x118 0,16 1 27,7 51 146
0302T - 2 2x17 2x30.5 2x173 0,16 1 35,3 67 209
0352T - 2 17+22.3 30.5+36.1 173+225 0,25 1 41,8 78 267
0412T - 2 2x22.3 2x36.1 2x225 0,25 1 47,1 83 272
0452T - 2 22.3+27.4 36.1+45.8 225+272 0,25 1 52,2 93 319
0512T - 2 2x27.4 2x45.8 2x272 0,25 1 57,3 103 329

F.L.I.: Full load power


F.L.A.: Full load current
L.R.A.: Locked rotor amperes for single compressor
S.A.: Inrush current

(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections

Electrical data valid for standard units without any additional option

Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.

Voltage tolerance: 10%


Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

ELCA_Engine ver.3.4.0.1 7.1.3 NECS 0202T - 0612T_201606_EN HCF R410A


ELECTRICAL DATA NECS / HT
[ SI System ]

Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202T - 2 2x11.8 2x20.4 2x118 0,25 1 25,1 47 145
0252T - 2 2x13.2 2x22.6 2x118 0,25 1 28,4 54 149
0302T - 2 2x17 2x30.5 2x173 0,25 1 36,0 70 212
0352T - 2 17+22.3 30.5+36.1 173+225 0,25 1 41,8 78 267
0412T - 2 2x22.3 2x36.1 2x225 0,25 1 47,1 83 272
0452T - 2 22.3+27.4 36.1+45.8 225+272 0,25 1 52,2 93 319
0512T - 2 2x27.4 2x45.8 2x272 0,25 1 57,3 103 329

F.L.I.: Full load power


F.L.A.: Full load current
L.R.A.: Locked rotor amperes for single compressor
S.A.: Inrush current

(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections

Electrical data valid for standard units without any additional option

Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.

Voltage tolerance: 10%


Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

ELCA_Engine ver.3.4.0.1 7.1.4 NECS 0202T - 0612T_201606_EN HCF R410A


8.1 FULL LOAD SOUND LEVEL NECS / B

SOUND POWER
Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202T 84 82 86 83 79 77 70 69 85
0252T 84 82 86 83 79 77 70 69 85
0302T 84 82 86 83 79 77 70 69 85
0352T 85 83 87 84 80 78 71 70 86
0412T 85 83 87 84 80 78 71 70 86
0452T 85 83 87 84 80 78 71 70 86
0512T 86 84 88 85 81 79 72 71 87
0552T 86 84 88 85 81 79 72 71 87
0612T 86 84 88 85 81 79 72 71 87

Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.

SOUND PRESSURE LEVEL


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound pressure level dB
0202T 52 50 54 51 47 45 38 37 53
0252T 52 50 54 51 47 45 38 37 53
0302T 52 50 54 51 47 45 38 37 53
0352T 53 51 55 52 48 46 39 38 54
0412T 53 51 55 52 48 46 39 38 54
0452T 53 51 55 52 48 46 39 38 54
0512T 54 52 56 53 49 47 40 39 55
0552T 54 52 56 53 49 47 40 39 55
0612T 54 52 56 53 49 47 40 39 55

Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.

ELCA_Engine ver.3.4.0.1 8.1.1 NECS 0202T - 0612T_201606_EN HCF R410A


FULL LOAD SOUND LEVEL NECS / LN

SOUND POWER
Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202T 81 79 82 79 74 70 62 60 80
0252T 81 79 82 79 74 70 62 60 80
0302T 82 80 83 80 75 71 63 61 81
0352T 82 80 84 81 77 75 68 67 83
0412T 82 80 84 81 77 75 68 67 83
0452T 82 80 84 81 77 75 68 67 83
0512T 83 81 85 82 78 76 69 68 84
0552T 83 81 85 82 78 76 69 68 84
0612T 83 81 85 82 78 76 69 68 84

Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.

SOUND PRESSURE LEVEL


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound pressure level dB
0202T 49 47 50 47 42 38 30 28 48
0252T 49 47 50 47 42 38 30 28 48
0302T 50 48 51 48 43 39 31 29 49
0352T 50 48 52 49 45 43 36 35 51
0412T 50 48 52 49 45 43 36 35 51
0452T 50 48 52 49 45 43 36 35 51
0512T 51 49 53 50 46 44 37 36 52
0552T 51 49 53 50 46 44 37 36 52
0612T 51 49 53 50 46 44 37 36 52

Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.

ELCA_Engine ver.3.4.0.1 8.1.2 NECS 0202T - 0612T_201606_EN HCF R410A


FULL LOAD SOUND LEVEL NECS / SL

SOUND POWER
Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202T 81 76 74 76 73 67 61 58 77
0252T 83 77 75 77 74 68 62 59 78
0302T 83 77 75 77 74 68 62 59 78
0352T 81 79 81 79 76 72 67 64 81
0412T 81 79 81 79 76 72 67 64 81
0452T 81 79 81 79 76 72 67 64 81
0512T 82 80 82 80 77 73 68 65 82

Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.

SOUND PRESSURE LEVEL


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound pressure level dB
0202T 49 44 42 44 41 35 29 26 45
0252T 51 45 43 45 42 36 30 27 46
0302T 51 45 43 45 42 36 30 27 46
0352T 49 47 49 47 44 40 35 32 49
0412T 49 47 49 47 44 40 35 32 49
0452T 49 47 49 47 44 40 35 32 49
0512T 50 48 50 48 45 41 36 33 50

Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.

ELCA_Engine ver.3.4.0.1 8.1.3 NECS 0202T - 0612T_201606_EN HCF R410A


FULL LOAD SOUND LEVEL NECS / HT

SOUND POWER
Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202T 84 82 86 83 79 77 70 69 85
0252T 85 83 87 84 80 78 71 70 86
0302T 85 83 87 84 80 78 71 70 86
0352T 86 84 88 85 81 79 72 71 87
0412T 86 84 88 85 81 79 72 71 87
0452T 86 84 88 85 81 79 72 71 87
0512T 86 84 88 85 81 79 72 71 87

Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.

SOUND PRESSURE LEVEL


Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound pressure level dB
0202T 52 50 54 51 47 45 38 37 53
0252T 53 51 55 52 48 46 39 38 54
0302T 53 51 55 52 48 46 39 38 54
0352T 54 52 56 53 49 47 40 39 55
0412T 54 52 56 53 49 47 40 39 55
0452T 54 52 56 53 49 47 40 39 55
0512T 54 52 56 53 49 47 40 39 55

Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.

ELCA_Engine ver.3.4.0.1 8.1.4 NECS 0202T - 0612T_201606_EN HCF R410A


ELCA_Engine ver.3.4.0.1
9.1 DIMENSIONAL DRAWINGS

9.1.1
NECS 0202T - 0612T

"REMARKS:
For installation purposes, please refer to the documentation sent after the purchase-contract. This technical data should be considered as indicative. CLIMAVENETA may modify them at any moment."

NECS 0202T - 0612T_201606_EN HCF R410A


DIMENSIONAL DRAWINGS NECS 0202T - 0612T
[ SI System ]

DIMENSIONS AND HEAT EXCHANGER


CLEARANCE
WEIGHTS USER SIDE
SIZE
A B H WEIGHT R1 R2 R3 R4 IN/OUT
[mm] [mm] [mm] [kg] [mm] [mm] [mm] [mm] TYPE Ø
NECS /B 0202T 2195 1120 1465 625 1000 1000 600 600 B 2"
NECS /B 0252T 2195 1120 1465 625 1000 1000 600 600 B 2"
NECS /B 0302T 2195 1120 1465 665 1000 1000 600 600 B 2"
NECS /B 0352T 2195 1120 1465 765 1000 1000 600 600 B 2"
NECS /B 0412T 2745 1120 1465 920 1000 1000 600 600 B 2"1/2
NECS /B 0452T 2745 1120 1465 990 1000 1000 600 600 B 2"1/2
NECS /B 0512T 3245 1120 1665 1135 1000 1000 600 600 B 2"1/2
NECS /B 0552T 3245 1120 1665 1180 1000 1000 600 600 B 2"1/2
NECS /B 0612T 3245 1120 1665 1155 1000 1000 600 600 B 2"1/2
NECS /LN 0202T 2195 1120 1465 625 1000 1000 600 600 B 2"
NECS /LN 0252T 2195 1120 1465 650 1000 1000 600 600 B 2"
NECS /LN 0302T 2745 1120 1465 715 1000 1000 600 600 B 2"
NECS /LN 0352T 2745 1120 1665 840 1000 1000 600 600 B 2"
NECS /LN 0412T 2745 1120 1665 965 1000 1000 600 600 B 2"1/2
NECS /LN 0452T 2745 1120 1665 1025 1000 1000 600 600 B 2"1/2
NECS /LN 0512T 3245 1120 1665 1135 1000 1000 600 600 B 2"1/2
NECS /LN 0552T 3245 1120 1665 1180 1000 1000 600 600 B 2"1/2
NECS /LN 0612T 3245 1120 1665 1155 1000 1000 600 600 B 2"1/2
NECS /SL 0202T 2195 1100 1465 650 1000 1000 600 600 B 2"
NECS /SL 0252T 2745 1100 1465 700 1000 1000 600 600 B 2"
NECS /SL 0302T 2745 1100 1465 750 1000 1000 600 600 B 2"
NECS /SL 0352T 3245 1100 1665 915 1000 1000 600 600 B 2"
NECS /SL 0412T 3245 1100 1665 1050 1000 1000 600 600 B 2"1/2
NECS /SL 0452T 3245 1100 1665 1075 1000 1000 600 600 B 2"1/2
NECS /SL 0512T 3245 1100 1665 1115 1000 1000 600 600 B 2"1/2
NECS /HT 0202T 2195 1120 1465 650 1000 1000 600 600 B 2"
NECS /HT 0252T 2745 1120 1465 700 1000 1000 600 600 B 2"
NECS /HT 0302T 2745 1120 1465 750 1000 1000 600 600 B 2"
NECS /HT 0352T 3245 1120 1665 915 1000 1000 600 600 B 2"
NECS /HT 0412T 3245 1120 1665 1050 1000 1000 600 600 B 2"1/2
NECS /HT 0452T 3245 1120 1665 1075 1000 1000 600 600 B 2"1/2
NECS /HT 0512T 3245 1120 1665 1115 1000 1000 600 600 B 2"1/2

ELCA_Engine ver.3.4.0.1 9.1.2 NECS 0202T - 0612T_201606_EN HCF R410A


DIMENSIONAL DRAWINGS NECS 0202T - 0612T

LEGEND OF PIPE CONNECTIONS

TYPE = B
Male threaded pipe

LEGEND OF PIPE CONNECTIONS


UNI ISO 228/1
Pipe threads where pressure-tight joints are not made on the threads - Designation, dimensions and tolerances
Used terminology:
G: Pipe threads where pressure-tight joints are not made on the threads
A: Close tolerance class for external pipe threads where pressure-tight joints are not made on the threads
B: Wider tolerance class for external pipe threads where pressure-tight joints are not made on the threads
Internal threads: G letter followed by thread mark (only tolerance class)
External threads: G letter followed by thread mark and by A letter for A class external threads or by B letter for B class external threads.

UNI EN 10226-1
Pipe threads where pressure-tight joints are made on the threads - Designation, dimensions and tolerances
Used terminology:
Rp: Internal cylindrical threads where pressure-tight joints are made on the threads
Rc: Internal conical threads where pressure-tight joints are made on the threads
R: External conical threads where pressure-tight joints are made on the threads
Internal cylindrical threads: R letter followed by p letter
Internal conical threads: R letter followed by c letter
External conical threads: R letter

Designation Description
Internal cylindrical threads where pressure-tight joints are made on the threads, defined by standard
UNI EN 10226-1 - Rp 1 1/2 UNI ISO 7/1
Conventional ø 1 1/2”
Internal cylindrical threads where pressure-tight joints are made on the threads, defined by standard
UNI EN 10226-1 - Rp 2 1/2 UNI ISO 7/1
Conventional ø 2 1/2”
Internal cylindrical threads where pressure-tight joints are made on the threads, defined by standard
UNI EN 10226-1 - Rp 3 UNI ISO 7/1
Conventional ø 3”
External conical threads where pressure-tight joints are made on the threads, defined by standard
UNI EN 10226-1 - R 3 UNI ISO 7/1
Conventional ø 3”
Internal cylindrical threads where pressure-tight joints are not made on the threads, defined by standard UNI ISO 228/1
UNI ISO 228/1 - G 4 B Tolerance class B for external thread
Conventional ø 4”
Flange Nominal Diameter: 80 mm
DN 80 PN 16
Nominal Pressure: 16 bar

Notes:
Conventional diameter value [in inches] identifies short thread designation, based upon the relative standard.
All relative values are defined by standards.
As example, here below some values:
UNI EN 10226-1 UNI ISO 228/1
Conventional ø 1" 1"
Pitch 2.309 mm 2.309 mm
External ø 33.249 mm 33.249 mm
Core ø 30.291 mm 30.291 mm
Thread height 1.479 mm 1.479 mm

ELCA_Engine ver.3.4.0.1 9.1.3 NECS 0202T - 0612T_201606_EN HCF R410A


10.1 HYDRONIC GROUP

10.1 HYDRONIC GROUP


The hydronic group consisting of:
- 1 or 2 pumps, 2 poles, low or high head
- 10 mm insulation lining on pumps and pipes
- pump inlet / oulet valves
- check valves (only for twin end-suction pumps)
- drain valve
- air vent

Each of the components of the hydraulic group has been designed to


optimise hydraulic and electrical installation space,
time and costs.
The hydronic group is protected by a special casing ventilating
(versions LN and SL).
In case of twin pump version, the second pump operates in stand-by
to the first. The relative operating hours of the two pumps are
balanced. In case the operating
pump breaks down, the reserve pump is automatically enabled.
The electrical panel of the unit is protected with fuses and contactors
with thermals cut-out.
The hydronic kit of this family includes end-suction pumps.

10.2 END-SUCTION PUMP SPECIFICATION


low or high head pump
Horizontal one-piece centrifuge pump, normalised to EN 733, axial
suction and radial delivery, in single or twin version. Pump with cast
iron body and AISI 316L stainless steel impeller. The section of the
shaft in contact with the liquid is made from stainless steel.
Mechanical seal with components in: ceramic/carbon/EPDM.
Three-phase electric motor protected to IP55, insulation class F,
suitable for continuous service.

10.3 SPECIAL PUMPS


For pumps with different configurations, please contact our sales
department.

10.4 OTHER COMPONENTS


The hydronic kits do not include the following accessories though
these are recommended to ensure correct system operation:
- Flow-out switch
- Pressure gauges upline and downline from the unit
- Flexible joints on piping
- On-off valves
- Outlet control thermometer
- Mains filter.

Possible configuration
Versions
PUMPS GROUP
B HT LN SL
KIT IDRONICO - 1
POMPA CENTRIF. 2P X X X X
BP(3342)
KIT IDRONICO - 1
POMPA CENTRIF. 2P X X X X
AP(3343)
KIT IDRONICO - 2
POMPE CENTRIF. 2P X X X X
BP(3345)
KIT IDRONICO - 2
POMPE CENTRIF. 2P X X X X
AP(3346)

ELCA_Engine ver.3.4.0.1 10.1.1 NECS 0202T - 0612T_201606_EN HCF R410A


HYDRONIC GROUP

ELCA_Engine ver.3.4.0.1 10.5.1 NECS 0202T - 0612T_201606_EN HCF R410A


HYDRONIC GROUP

Hydronic kit positioning

KIT IDRONICO - 1 POMPA KIT IDRONICO - 1 POMPA KIT IDRONICO - 2 POMPE KIT IDRONICO - 2 POMPE
CENTRIF. 2P BP (3342) CENTRIF. 2P AP (3343) CENTRIF. 2P BP (3345) CENTRIF. 2P AP (3346)
Version
extra L extra W extra H extra
extrawgt
H extra L extra W extra H extra
extrawgt
H extra L extra W extra H extra
extrawgt
H extra L extra W extra H extra
extrawgt
H
[mm] [mm] [mm] [mm]
[kg] [mm] [mm] [mm] [mm]
[kg] [mm] [mm] [mm] [mm]
[kg] [mm] [mm] [mm] [mm]
[kg]

B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0202T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0252T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0302T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0352T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0412T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0452T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0512T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
0552T
LN / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
0612T
LN / / / / / / / / / / / / / / / /

extra L Unit's extra length


extra W Unit's extra operating width (NOT to be considered for transport)
extra H Unit's extra height
extra H
extra wgt Unit's extra weight (pumps and piping)
KIT IDRONICO - 1 POMPA HYDRONIC KIT 1 CENTRIFUG. PUMP 2 POLES LH
CENTRIF. 2P BP
KIT IDRONICO - 1 POMPA HYDRONIC KIT 1 CENTRIFUG. PUMP 2 POLES HH
CENTRIF. 2P AP
KIT IDRONICO - 2 POMPE HYDRONIC KIT 2 CENTRIFUG. PUMPS 2 POLES LH
CENTRIF. 2P BP
KIT IDRONICO - 2 POMPE HYDRONIC KIT 2 CENTRIFUG. PUMPS 2 POLES HH
CENTRIF. 2P AP
- Unavailable

ELCA_Engine ver.3.4.0.1 10.5.3 NECS 0202T - 0612T_201606_EN HCF R410A


HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 1 CENTRIFUG. PUMP 2 POLES HH


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
B 53,0 2,54 208
HT 55,0 2,63 206
0202T LN 50,7 2,42 A1 210
SL 47,8 2,29 213
B 58,1 2,78 DWC-V 300/1,5 2 4 1,50 202
HT 61,6 2,94 198
0252T A2
LN 57,6 2,75 203
SL 55,5 2,65 205
B 76,0 3,63 209
HT 80,6 3,86 204
0302T LN 74,2 3,55 B1 210
SL 69,9 3,34 214
B 86,8 4,15 198
HT 91,4 4,37 193
0352T LN 84,4 4,04 B2 DWC-V 500/2,2 2 5 2,20 201
SL 85,4 4,08 200
B 96,9 4,63 206
HT 104 4,99 200
0412T B3
LN 96,4 4,61 206
SL 96,8 4,63 206
B 112 5,37 204
HT 116 5,53 201
0452T LN 109 5,20 C1 207
SL 106 5,07 209
B 127 6,06 DWC-V 500/3 2 6 3,00 197
HT 130 6,21 195
0512T C2
LN 122 5,83 201
SL 117 5,62 205
B 145 6,93 216
0552T LN 139 6,64 D1 222
3D 40-160/3 2 6 3,00
B 159 7,58 201
0612T D2
LN 151 7,21 209

(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)

ELCA_Engine ver.3.4.0.1 10.5.3 NECS 0202T - 0612T_201606_EN HCF R410A


HYDRONIC GROUP

ELCA_Engine ver.3.4.0.1 10.5.4 NECS 0202T - 0612T_201606_EN HCF R410A


HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 1 CENTRIFUG. PUMP 2 POLES LH


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
B 53,0 2,54 116
HT 55,0 2,63 114
0202T LN 50,7 2,42 A1 119
SL 47,8 2,29 122
B 58,1 2,78 110
HT 61,6 2,94 106
0252T A2 DWC-V 300/1,1( R ) 2 3 1,10
LN 57,6 2,75 111
SL 55,5 2,65 113
B 76,0 3,63 85,8
HT 80,6 3,86 78,6
0302T LN 74,2 3,55 A3 88,5
SL 69,9 3,34 94,6
B 86,8 4,15 123
HT 91,4 4,37 115
0352T LN 84,4 4,04 B1 127
SL 85,4 4,08 125
B 96,9 4,63 124
HT 104 4,99 113
0412T B2 DWC-V 300/1,1 2 3 1,10
LN 96,4 4,61 124
SL 96,8 4,63 124
B 112 5,37 99,8
HT 116 5,53 94,3
0452T LN 109 5,20 B3 106
SL 106 5,07 110
B 127 6,06 129
HT 130 6,21 124
0512T C1 DWC-V 300/1,5 2 4 1,50
LN 122 5,83 135
SL 117 5,62 142
B 145 6,93 103
0552T LN 139 6,64 D1 DWC-V 500/1,5 2 4 1,50 109
B 159 7,58 91,8
0612T E1 3D 40-125/1.5 2 3 1,50
LN 151 7,21 101

(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)

ELCA_Engine ver.3.4.0.1 10.5.5 NECS 0202T - 0612T_201606_EN HCF R410A


HYDRONIC GROUP

ELCA_Engine ver.3.4.0.1 10.5.6 NECS 0202T - 0612T_201606_EN HCF R410A


HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 2 CENTRIFUG. PUMPS 2 POLES HH


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
B 53,0 2,54 208
HT 55,0 2,63 206
0202T LN 50,7 2,42 A1 210
SL 47,8 2,29 213
B 58,1 2,78 DWC-V 300/1,5 2 4 1,50 202
HT 61,6 2,94 198
0252T A2
LN 57,6 2,75 203
SL 55,5 2,65 205
B 76,0 3,63 209
HT 80,6 3,86 204
0302T LN 74,2 3,55 B1 210
SL 69,9 3,34 214
B 86,8 4,15 198
HT 91,4 4,37 193
0352T LN 84,4 4,04 B2 DWC-V 500/2,2 2 5 2,20 201
SL 85,4 4,08 200
B 96,9 4,63 206
HT 104 4,99 200
0412T B3
LN 96,4 4,61 206
SL 96,8 4,63 206
B 112 5,37 204
HT 116 5,53 201
0452T LN 109 5,20 C1 207
SL 106 5,07 209
B 127 6,06 DWC-V 500/3 2 6 3,00 197
HT 130 6,21 195
0512T C2
LN 122 5,83 201
SL 117 5,62 205
B 145 6,93 216
0552T LN 139 6,64 D1 222
3D 40-160/3 2 6 3,00
B 159 7,58 201
0612T D2
LN 151 7,21 209

(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)

ELCA_Engine ver.3.4.0.1 10.5.7 NECS 0202T - 0612T_201606_EN HCF R410A


HYDRONIC GROUP

ELCA_Engine ver.3.4.0.1 10.5.8 NECS 0202T - 0612T_201606_EN HCF R410A


HYDRONIC GROUP

HEAT EXCHANGER USER SIDE - HYDRONIC KIT 2 CENTRIFUG. PUMPS 2 POLES LH


CH PUMP CH
SIZE Pfgross Qfgross N. F.L.A. F.L.I. HU
Rif. Model
[kW] (1) [l/s] (1) Pole [A] [kW] [kPa]
B 53,0 2,54 116
HT 55,0 2,63 114
0202T LN 50,7 2,42 A1 119
SL 47,8 2,29 122
B 58,1 2,78 110
HT 61,6 2,94 106
0252T A2 DWC-V 300/1,1( R ) 2 3 1,10
LN 57,6 2,75 111
SL 55,5 2,65 113
B 76,0 3,63 85,8
HT 80,6 3,86 78,6
0302T LN 74,2 3,55 A3 88,5
SL 69,9 3,34 94,6
B 86,8 4,15 123
HT 91,4 4,37 115
0352T LN 84,4 4,04 B1 127
SL 85,4 4,08 125
B 96,9 4,63 124
HT 104 4,99 113
0412T B2 DWC-V 300/1,1 2 3 1,10
LN 96,4 4,61 124
SL 96,8 4,63 124
B 112 5,37 99,8
HT 116 5,53 94,3
0452T LN 109 5,20 B3 106
SL 106 5,07 110
B 127 6,06 129
HT 130 6,21 124
0512T C1 DWC-V 300/1,5 2 4 1,50
LN 122 5,83 135
SL 117 5,62 142
B 145 6,93 103
0552T LN 139 6,64 D1 DWC-V 500/1,5 2 4 1,50 109
B 159 7,58 91,8
0612T E1 3D 40-125/1.5 2 3 1,50
LN 151 7,21 101

(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)

ELCA_Engine ver.3.4.0.1 10.5.9 NECS 0202T - 0612T_201606_EN HCF R410A


HYDRONIC GROUP

ELCA_Engine ver.3.4.0.1 10.5.10 NECS 0202T - 0612T_201606_EN HCF R410A


Climaveneta S.p.A.

Via Sarson 57/c


36061 Bassano del Grappa (VI)
Italy
Tel +39 0424 509 500
Fax +39 0424 509 509
info@climaveneta.com
www.climaveneta.com

Subsidiaries

France
www.climaveneta.fr

Spain
www.climaveneta.es

Poland
www.climaveneta.pl

Germany
www.climaveneta.de

Great Britain
www.climaveneta.co.uk

Russia
ru.climaveneta.com

China
www.climaveneta.com.cn

India
www.climaveneta.in

Middle East
ae.climaveneta.com

Southeast Asia
www.climaveneta.com

Hong Kong
www.climaveneta.com

For more information:


www.climaveneta.com

You might also like