(The photo of the unit is indicative and may vary depending on the model)
EXCHANGER
MAXIMUM RELIABILITY
INTEGRATED HYDRONIC MODULE
CERTIFICATIONS
Product certifications
System certifications
Climaveneta S.p.A.:
Liability disclaimer
The present publication is drawn up by of information only and does not constitute an offer binding upon Climaveneta.
Climaveneta has compiled the content of this publication to the best of its knowledge. The data contained herein are subject to change without
notice. Climaventa explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or
interpretation of this publication. All content is copyrighted by Climaveneta.
Functions
Cooling
Refrigerant
R-410A
Compressors
Scroll compressor
Fan
Axial fan
Exchangers
Other features
Eurovent
To find out more about how our products contribute to enhanced green
certification rating and energy performance of a building, please refer
to:
http://www.climaveneta.com/GLOBAL/Company/Green-Certifications/
QR code
Outdoor unit for the production of chilled water with hermetic rotary Scroll
compressors, axialflow fans, shell and tubes exchanger and thermostatic
expansion valve. External panels in Peraluman and structure in
aluminium sections. The range is equipped with two compressors on two
independent refrigerant circuits.
1.3 EXCHANGER
The shell and tube exchanger allows to achieve the highest flexibility on
the unit’s installation, keeping on the hydronic side the pressure drops at
the minimum level, thus representing the best choice for all the hydronic
applications on the residential, commercial and industrial markets.
/B – Basic version
Standard unit
2.15 Configurations
< >, Standard unit
Standard unit for production of chilled water
NECS / B 0202T 0252T 0302T 0352T 0412T 0452T 0512T 0552T 0612T
Power supply V/ph/Hz - - - - - - - - -
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 53,0 58,1 76,0 86,8 96,9 112 127 145 159
Total power input (1) kW 18,3 21,5 27,8 31,9 36,3 39,7 43,7 50,2 58,6
EER (1) kW/kW 2,90 2,70 2,73 2,72 2,67 2,83 2,90 2,89 2,71
ESEER (1) kW/kW 3,72 3,47 3,52 3,49 3,41 3,59 3,65 3,66 3,44
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 52,9 58,0 75,8 86,5 96,7 112 126 144 158
EER (1)(2) kW/kW 2,88 2,68 2,71 2,69 2,65 2,80 2,87 2,85 2,67
ESEER (1)(2) kW/kW 3,68 3,41 3,45 3,40 3,36 3,51 3,59 3,58 3,37
Cooling energy class C D C D D C C C D
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 2,54 2,78 3,63 4,15 4,63 5,37 6,06 6,93 7,58
Pressure drop (1) kPa 6,25 7,64 13,1 17,2 12,8 17,2 15,7 21,7 25,9
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2 2 2 2 2 2 2 2
Number of capacity N° 2 2 2 2 2 2 2 2 2
No. Circuits N° 2 2 2 2 2 2 2 2 2
Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS
Min. capacity step % 50 50 50 50 50 50 50 50 50
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant charge kg 10 10 13 14 16 18 21 25 23
Oil charge kg 6 6 6 8 9 11 14 13 13
Rc (ASHRAE) (3) kg/kW 0,196 0,179 0,167 0,159 0,169 0,160 0,170 0,175 0,146
FANS
Quantity N° 6 6 6 6 6 8 10 10 10
Air flow m³/s 7,92 7,92 7,63 7,35 7,85 9,88 13,09 12,77 12,77
Fans power input kW 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25
NOISE LEVEL
Noise Pressure (4) dB(A) 53 53 53 54 54 54 55 55 55
Sound power level in cooling (5)(6) dB(A) 85 85 85 86 86 86 87 87 87
SIZE AND WEIGHT
A (7) mm 2195 2195 2195 2195 2745 2745 3245 3245 3245
B (7) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120
H (7) mm 1465 1465 1465 1465 1465 1465 1665 1665 1665
Operating weight (7) kg 625 625 665 765 920 990 1135 1180 1155
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511-3:2013.
3 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
4 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
5 Sound power on the basis of measurements made in compliance with ISO 9614.
6 Sound power level in cooling, outdoors.
7 Unit in standard configuration/execution, without optional accessories.
- Unavailable
Certified data in EUROVENT
NECS / LN 0202T 0252T 0302T 0352T 0412T 0452T 0512T 0552T 0612T
Power supply V/ph/Hz - - - - - - - - -
PERFORMANCE
COOLING ONLY (GROSS VALUE)
Cooling capacity (1) kW 50,7 57,6 74,2 84,4 96,4 109 122 139 151
Total power input (1) kW 18,9 21,2 28,6 33,7 37,1 41,4 45,9 53,1 62,4
EER (1) kW/kW 2,68 2,72 2,59 2,50 2,60 2,63 2,66 2,61 2,42
ESEER (1) kW/kW 3,50 3,51 3,37 3,22 3,33 3,36 3,38 3,34 3,11
COOLING ONLY (EN14511 VALUE)
Cooling capacity (1)(2) kW 50,6 57,5 74,0 84,2 96,2 108 122 138 150
EER (1)(2) kW/kW 2,67 2,70 2,57 2,48 2,58 2,60 2,64 2,59 2,39
ESEER (1)(2) kW/kW 3,46 3,46 3,30 3,17 3,27 3,30 3,32 3,28 3,04
Cooling energy class D C D E D D D D E
EXCHANGERS
HEAT EXCHANGER USER SIDE IN REFRIGERATION
Water flow (1) l/s 2,42 2,75 3,55 4,04 4,61 5,20 5,83 6,64 7,21
Pressure drop (1) kPa 5,70 7,50 12,5 16,3 12,7 16,2 14,6 19,9 23,5
REFRIGERANT CIRCUIT
Compressors nr. N° 2 2 2 2 2 2 2 2 2
Number of capacity N° 2 2 2 2 2 2 2 2 2
No. Circuits N° 2 2 2 2 2 2 2 2 2
Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS
Min. capacity step % 50 50 50 50 50 50 50 50 50
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant charge kg 10 13 12 15 18 20 21 25 23
Oil charge kg 6 6 6 8 9 11 14 13 13
Rc (ASHRAE) (3) kg/kW 0,205 0,221 0,162 0,177 0,186 0,182 0,177 0,182 0,153
FANS
Quantity N° 6 6 8 8 8 8 10 10 10
Air flow m³/s 6,04 5,73 8,16 9,03 8,77 8,55 10,96 10,69 10,69
Fans power input kW 0,16 0,16 0,16 0,25 0,25 0,25 0,25 0,25 0,25
NOISE LEVEL
Noise Pressure (4) dB(A) 48 48 49 51 51 51 52 52 52
Sound power level in cooling (5)(6) dB(A) 80 80 81 83 83 83 84 84 84
SIZE AND WEIGHT
A (7) mm 2195 2195 2745 2745 2745 2745 3245 3245 3245
B (7) mm 1120 1120 1120 1120 1120 1120 1120 1120 1120
H (7) mm 1465 1465 1465 1665 1665 1665 1665 1665 1665
Operating weight (7) kg 625 650 715 840 965 1025 1135 1180 1155
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511-3:2013.
3 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
4 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
5 Sound power on the basis of measurements made in compliance with ISO 9614.
6 Sound power level in cooling, outdoors.
7 Unit in standard configuration/execution, without optional accessories.
- Unavailable
Certified data in EUROVENT
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511-3:2013.
3 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
4 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
5 Sound power on the basis of measurements made in compliance with ISO 9614.
6 Sound power level in cooling, outdoors.
7 Unit in standard configuration/execution, without optional accessories.
- Unavailable
Certified data in EUROVENT
Notes:
1 Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
2 Values in compliance with EN14511-3:2013.
3 Rated in accordance with AHRI Standard 550/590 (2011 with addendum 1).
4 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
5 Sound power on the basis of measurements made in compliance with ISO 9614.
6 Sound power level in cooling, outdoors.
7 Unit in standard configuration/execution, without optional accessories.
- Unavailable
Certified data in EUROVENT
(* if present)
SIZE
NECS /B 0202T
NECS /B 0252T
NECS /B 0302T
NECS /B 0352T
NECS /B 0412T
NECS /B 0452T
NECS /B 0512T
NECS /B 0552T
NECS /B 0612T
NECS /LN 0202T
NECS /LN 0252T
NECS /LN 0302T
NECS /LN 0352T
NECS /LN 0412T
NECS /LN 0452T
NECS /LN 0512T
NECS /LN 0552T
NECS /LN 0612T
NECS /SL 0202T
NECS /SL 0252T
NECS /SL 0302T
NECS /SL 0352T
NECS /SL 0412T
NECS /SL 0452T
NECS /SL 0512T
NECS /HT 0202T
NECS /HT 0252T
NECS /HT 0302T
NECS /HT 0352T
NECS /HT 0412T
NECS /HT 0452T
NECS /HT 0512T
cPf: cooling power correction factor For data concerning other kind of anti-freeze solutions (e,g, propylene
cQ: flow correction factor glycol) please contact our Sale Department.
cdp: pressure drop correction factor
Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202T - 2 2x11.8 2x20.4 2x118 0,25 1 25,1 47 145
0252T - 2 2x13.2 2x22.6 2x118 0,25 1 27,9 52 147
0302T - 2 2x17 2x30.5 2x173 0,25 1 35,5 68 210
0352T - 2 17+22.3 30.5+36.1 173+225 0,25 1 40,8 73 262
0412T - 2 2x22.3 2x36.1 2x225 0,25 1 46,1 79 268
0452T - 2 22.3+27.4 36.1+45.8 225+272 0,25 1 51,7 91 317
0512T - 2 2x27.4 2x45.8 2x272 0,25 1 57,3 103 329
0552T - 2 27.4+35.8 45.8+58.9 272+310 0,25 1 65,7 116 367
0612T - 2 2x35.8 2x58.9 2x310 0,25 1 74,1 129 380
(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections
Electrical data valid for standard units without any additional option
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.
(*) for the unit’s operating limits, see “selection limits” section
Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202T - 2 2x11.8 2x20.4 2x118 0,16 1 24,6 45 143
0252T - 2 2x13.2 2x22.6 2x118 0,16 1 27,4 49 145
0302T - 2 2x17 2x30.5 2x173 0,16 1 35,3 67 209
0352T - 2 17+22.3 30.5+36.1 173+225 0,25 1 41,3 75 264
0412T - 2 2x22.3 2x36.1 2x225 0,25 1 46,6 81 270
0452T - 2 22.3+27.4 36.1+45.8 225+272 0,25 1 51,7 91 317
0512T - 2 2x27.4 2x45.8 2x272 0,25 1 57,3 103 329
0552T - 2 27.4+35.8 45.8+58.9 272+310 0,25 1 65,7 116 367
0612T - 2 2x35.8 2x58.9 2x310 0,25 1 74,1 129 380
(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections
Electrical data valid for standard units without any additional option
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.
(*) for the unit’s operating limits, see “selection limits” section
Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202T - 2 2x11.8 2x20.4 2x118 0,16 1 24,6 45 143
0252T - 2 2x13.2 2x22.6 2x118 0,16 1 27,7 51 146
0302T - 2 2x17 2x30.5 2x173 0,16 1 35,3 67 209
0352T - 2 17+22.3 30.5+36.1 173+225 0,25 1 41,8 78 267
0412T - 2 2x22.3 2x36.1 2x225 0,25 1 47,1 83 272
0452T - 2 22.3+27.4 36.1+45.8 225+272 0,25 1 52,2 93 319
0512T - 2 2x27.4 2x45.8 2x272 0,25 1 57,3 103 329
(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections
Electrical data valid for standard units without any additional option
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.
(*) for the unit’s operating limits, see “selection limits” section
Maximum values
Power
Compressor Fans (1) Total (1)(2)
SIZE supply
V/ph/Hz F.L.I. F.L.A. L.R.A. F.L.I. F.L.A. F.L.I. F.L.A. S.A.
n [kW] [A] [A] [kW] [A] [kW] [A] [A]
0202T - 2 2x11.8 2x20.4 2x118 0,25 1 25,1 47 145
0252T - 2 2x13.2 2x22.6 2x118 0,25 1 28,4 54 149
0302T - 2 2x17 2x30.5 2x173 0,25 1 36,0 70 212
0352T - 2 17+22.3 30.5+36.1 173+225 0,25 1 41,8 78 267
0412T - 2 2x22.3 2x36.1 2x225 0,25 1 47,1 83 272
0452T - 2 22.3+27.4 36.1+45.8 225+272 0,25 1 52,2 93 319
0512T - 2 2x27.4 2x45.8 2x272 0,25 1 57,3 103 329
(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current
(1)(2) Safety values to be considered when cabling the unit for power supply and line-protections
Electrical data valid for standard units without any additional option
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes:
- climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and
a maximum solar radiation of 1120 W/m2
- special climatic conditions negligible
- biological conditions class 4B1 and 4C2: locations in a generic urban area
- mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas
- mechanical conditions class 4M1: locations protected from significant vibrations or shocks
The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with
diameter larger than 1 mm and rain).
The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.
(*) for the unit’s operating limits, see “selection limits” section
SOUND POWER
Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202T 84 82 86 83 79 77 70 69 85
0252T 84 82 86 83 79 77 70 69 85
0302T 84 82 86 83 79 77 70 69 85
0352T 85 83 87 84 80 78 71 70 86
0412T 85 83 87 84 80 78 71 70 86
0452T 85 83 87 84 80 78 71 70 86
0512T 86 84 88 85 81 79 72 71 87
0552T 86 84 88 85 81 79 72 71 87
0612T 86 84 88 85 81 79 72 71 87
Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.
Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
SOUND POWER
Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202T 81 79 82 79 74 70 62 60 80
0252T 81 79 82 79 74 70 62 60 80
0302T 82 80 83 80 75 71 63 61 81
0352T 82 80 84 81 77 75 68 67 83
0412T 82 80 84 81 77 75 68 67 83
0452T 82 80 84 81 77 75 68 67 83
0512T 83 81 85 82 78 76 69 68 84
0552T 83 81 85 82 78 76 69 68 84
0612T 83 81 85 82 78 76 69 68 84
Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.
Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
SOUND POWER
Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202T 81 76 74 76 73 67 61 58 77
0252T 83 77 75 77 74 68 62 59 78
0302T 83 77 75 77 74 68 62 59 78
0352T 81 79 81 79 76 72 67 64 81
0412T 81 79 81 79 76 72 67 64 81
0452T 81 79 81 79 76 72 67 64 81
0512T 82 80 82 80 77 73 68 65 82
Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.
Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
SOUND POWER
Octave band [Hz]
Total sound
SIZE 63 125 250 500 1000 2000 4000 8000 level
dB(A)
Sound power level dB
0202T 84 82 86 83 79 77 70 69 85
0252T 85 83 87 84 80 78 71 70 86
0302T 85 83 87 84 80 78 71 70 86
0352T 86 84 88 85 81 79 72 71 87
0412T 86 84 88 85 81 79 72 71 87
0452T 86 84 88 85 81 79 72 71 87
0512T 86 84 88 85 81 79 72 71 87
Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Sound power on the basis of measurements made in compliance with ISO 9614.
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Sound power level in cooling, outdoors.
Working conditions
Plant (side) cooling exchanger water (in/out) 12,0°C/7,0°C; Source (side) heat exchanger air (in) 35,0°C.
Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level.
9.1.1
NECS 0202T - 0612T
"REMARKS:
For installation purposes, please refer to the documentation sent after the purchase-contract. This technical data should be considered as indicative. CLIMAVENETA may modify them at any moment."
TYPE = B
Male threaded pipe
UNI EN 10226-1
Pipe threads where pressure-tight joints are made on the threads - Designation, dimensions and tolerances
Used terminology:
Rp: Internal cylindrical threads where pressure-tight joints are made on the threads
Rc: Internal conical threads where pressure-tight joints are made on the threads
R: External conical threads where pressure-tight joints are made on the threads
Internal cylindrical threads: R letter followed by p letter
Internal conical threads: R letter followed by c letter
External conical threads: R letter
Designation Description
Internal cylindrical threads where pressure-tight joints are made on the threads, defined by standard
UNI EN 10226-1 - Rp 1 1/2 UNI ISO 7/1
Conventional ø 1 1/2”
Internal cylindrical threads where pressure-tight joints are made on the threads, defined by standard
UNI EN 10226-1 - Rp 2 1/2 UNI ISO 7/1
Conventional ø 2 1/2”
Internal cylindrical threads where pressure-tight joints are made on the threads, defined by standard
UNI EN 10226-1 - Rp 3 UNI ISO 7/1
Conventional ø 3”
External conical threads where pressure-tight joints are made on the threads, defined by standard
UNI EN 10226-1 - R 3 UNI ISO 7/1
Conventional ø 3”
Internal cylindrical threads where pressure-tight joints are not made on the threads, defined by standard UNI ISO 228/1
UNI ISO 228/1 - G 4 B Tolerance class B for external thread
Conventional ø 4”
Flange Nominal Diameter: 80 mm
DN 80 PN 16
Nominal Pressure: 16 bar
Notes:
Conventional diameter value [in inches] identifies short thread designation, based upon the relative standard.
All relative values are defined by standards.
As example, here below some values:
UNI EN 10226-1 UNI ISO 228/1
Conventional ø 1" 1"
Pitch 2.309 mm 2.309 mm
External ø 33.249 mm 33.249 mm
Core ø 30.291 mm 30.291 mm
Thread height 1.479 mm 1.479 mm
Possible configuration
Versions
PUMPS GROUP
B HT LN SL
KIT IDRONICO - 1
POMPA CENTRIF. 2P X X X X
BP(3342)
KIT IDRONICO - 1
POMPA CENTRIF. 2P X X X X
AP(3343)
KIT IDRONICO - 2
POMPE CENTRIF. 2P X X X X
BP(3345)
KIT IDRONICO - 2
POMPE CENTRIF. 2P X X X X
AP(3346)
KIT IDRONICO - 1 POMPA KIT IDRONICO - 1 POMPA KIT IDRONICO - 2 POMPE KIT IDRONICO - 2 POMPE
CENTRIF. 2P BP (3342) CENTRIF. 2P AP (3343) CENTRIF. 2P BP (3345) CENTRIF. 2P AP (3346)
Version
extra L extra W extra H extra
extrawgt
H extra L extra W extra H extra
extrawgt
H extra L extra W extra H extra
extrawgt
H extra L extra W extra H extra
extrawgt
H
[mm] [mm] [mm] [mm]
[kg] [mm] [mm] [mm] [mm]
[kg] [mm] [mm] [mm] [mm]
[kg] [mm] [mm] [mm] [mm]
[kg]
B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0202T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0252T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0302T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0352T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0412T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0452T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
HT / / / / / / / / / / / / / / / /
0512T
LN / / / / / / / / / / / / / / / /
SL / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
0552T
LN / / / / / / / / / / / / / / / /
B / / / / / / / / / / / / / / / /
0612T
LN / / / / / / / / / / / / / / / /
(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)
(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)
(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)
(1) Values refer to nominal conditions Q Plant (side) exchanger water flow
CH Cooling mode F.L.I. Pump power input
Pf Cooling capacity unit (Cooling mode) F.L.A. Pump running current
Pt Heating capacity unit (Heating mode) HU Pump residual pressure head (Units with hydronic group without mains filter)
Subsidiaries
France
www.climaveneta.fr
Spain
www.climaveneta.es
Poland
www.climaveneta.pl
Germany
www.climaveneta.de
Great Britain
www.climaveneta.co.uk
Russia
ru.climaveneta.com
China
www.climaveneta.com.cn
India
www.climaveneta.in
Middle East
ae.climaveneta.com
Southeast Asia
www.climaveneta.com
Hong Kong
www.climaveneta.com