Professional Documents
Culture Documents
10 Double Layer Lap Winding Scheme
10 Double Layer Lap Winding Scheme
Scheme
Double Layer Lap Winding Scheme (1)
The relative electrical angle (expressed in the range of -180
o
to 180
o
)
of the kthslot is:
( ) mod ( 1) 180,360 180
slot
k k u ( = +
Of course, the relative electrical angle of In slot of the kthcoil is also:
( ) mod ( 1) 180,360 180
coil
k k u ( = +
Step 1. Find the nominal coil span in slots
max fix ,1
c
S
S
P
| |
| |
=
| |
\ .
\ .
Step 2. Calculate the relative electric angle of In slot of all coils
Step 3. Readjust In slot angles if their magnitude are greater than 90
o
For coil angles having a magnitude greater than 90
o
, the coil
direction is reversed; thereby changing the angle by 180
o
.
1
c
S
S
P
= If S/P is an integer
If S/P is not an integer
Double Layer Lap Winding Scheme (2)
For the angles calculated in last step, pick up those (S/m) close to 0
o
as phase A coils.
360
mod ,360
off
S
m
( =