You are on page 1of 4

CELINE POWER INTERNATIONAL S.L.

CELINE POWER INTERNATIONAL S.L.


Plaza Sierra Castilla 33 03177 San Fulgencio-Spain www.celine-photovoltaic-power.com info@celine-power.com

Plug & Save: Connect it and Save. It is that simple to convert sunlight into electricity, with the first worldwide mobile solar system with integrated energy storage from Sun Invention. Electricity flows directly from the solar panel into your socket and can reduce the electricity bill by approximately 25 per cent. You simply plug the outgoing power cable of the system into a socket. Several panels can be connected in between each other. In addition, the integrated energy storage ensures that electricity produced during the day is available at night. Whether you are a tenant or an owner you will always find a sunny place for the panels in the garden, on the terrace or the roof, on the faade or on the balcony. The corresponding mounting accessories are part of the complete system, with three years guarantee.

Model Optimus (PS195mS1.3), with integrated energy storage: Dimensions: 808mm x 1580mm x 60mm (W x H x D), double wall aluminium frame Solar Panel: Pmax 195 W Voc 45,52 V lsc 5,58 A Vmpp 37,44 V lmpp 5,21 A Inverter: V-DC mpp V-OC l-DC max V-AC nom f-AC nom P-AC nom l-AC nom Efficiency 24-40 V 50 V 10,4 A 184-264 V 47-51 Hz 235 W 1,07 A 95,2%

Model Light (PS195oS1.3)&Basic (PS195BASIC), without energy storage: Dimensions: 808mm x 1580mm x 60mm (W x H x D), double wall aluminium frame Panel: Pmax Voc lsc Vmpp lmpp 195 W 45,52 V 5,58 A 37,44 V 5,21 A

Inverter (only included in Light version): V-DC mpp 24-40 V V-OC 50 V l-DC max 10,4 A V-AC nom 184-264 V f-AC nom 47-51 Hz P-AC nom 235 W l-AC nom 1,07 A Efficiency 95,2% Manufacturer warranty: Complete system: 3 years Solar panel: 10 years Inverter: 10 years (only included in light version) Performance warranty 80% Pmax (panel): 25 years Protection class IP65 EN 50438 - ENEL - UL1741 - CQC VDE0126-1-1 - IEEE1547 - AS4777 EN 62109 - IEC 62109-1/-2 - SEMKO

Energy Storage: Lithium-Ion batteries Block 8 batteries with BMS 8x3,2 V/15 Ah Charge 430 Wh Discharge 250 Wh Manufacturer warranty: Complete system: 3 years Solar panel: 10 years Inverter: 10 years Performance warranty 80% Pmax (panel): 25 years

Performance curve Model Optimus, Light as well as Basic at 20 inclination


TRI-KA Measuring Messung 1
Start measuring: 21.08.2012 10:50:01 Messung Start:21.08.2012 10:50:01 End measuring: 21.08.2012 10:50:13 10:50:13 Messung Ende:21.08.2012 Client: Balcony module/Installation: Installation 1/Inverter: Inverter 1/String: 1 String 1 Kunde: Balkon Modul / Anlage: Anlage 1 / Wechselrichter: Wechselrichter 1 String / String:

Temperatur = Measured = gemessen temperature


Measured == Bestrahlung radiation gemessen Measured Neigung = = inclination gemessen

32,3 C

720 W/m

20

ISC Roh = ISC STC = ISC NOM =


Current [A] Power [W]

4,225 A 5,87 A 5,58 A 3,666 A 5,09 A 5,24 A 42,58 V 44,66 V 45,4 V 34,35 V 36,44 V 37,2 V 125,9 W 185,5 W 195 W 0,70 0,71 0,77

IMPP Roh = IMPP STC = IMPP NOM = UOC Roh = UOC STC = UOC NOM = UMPP Roh = UMPP STC = UMPP NOM = P Roh = P STC = P NOM = FF Roh = FF STC = FF NOM =

Voltage [V]

21.08.2012 11:07

Performance curve Model Optimus, Light as well as Basic at 70 inclination


TRI-KA Measuring Messung 11 Messung Start:21.08.2012 10:53:02 Start measuring: 21.08.2012 10:53:02 Messung Ende:21.08.2012 End measuring: 21.08.2012 10:53:16 10:53:16 Kunde: Balkon Modul / Anlage: Anlage 1 / Wechselrichter: Wechselrichter 1 String / String: String 2 70 Client: Balcony module/Installation: Installation 1/Inverter: Inverter 1/String: 2 70 Temperatur = Measured = gemessen temperature
Measured == Bestrahlung gemessen radiation Measured Neigung = = inclination gemessen

29,4 C

790 W/m

66

ISC Roh = ISC STC = ISC NOM =


Current [A] Power [W]

4,239 A 5,37 A 5,58 A 3,909 A 4,95 A 5,24 A 41,59 V 42,91 V 45,4 V 33,25 V 34,57 V 37,2 V 130 W 171,1 W 195 W 0,74 0,74 0,77

IMPP Roh = IMPP STC = IMPP NOM = UOC Roh = UOC STC = UOC NOM = UMPP Roh = UMPP STC = UMPP NOM = P Roh = P STC = P NOM = FF Roh = FF STC = FF NOM =

Voltage [V]

21.08.2012 11:09

CELINE POWER INTERNATIONAL S.L.


Plaza Sierra Castilla 33 03177 San Fulgencio-Spain www.celine-photovoltaic-power.com info@celine-power.com

Available at: