You are on page 1of 1

Analysis using Hanger - Intergraph CADWorx & Analysis

Page 1 of 1

You are not logged in. [Log Home Page Forums Analysis Solutions CAESAR II Analysis using Hanger
Register User Forum List Calendar Active Topics FAQ

Topic Options Analysis using Hanger #37449 - 08/16/10 02:28 AM Engr_mech


Member Registered: 06/01/10 Posts: 64 Loc: Australia

Who's Online 0 registered (), 5 Guests and 1 Spider online.


Key: Admin, Global Mod Mod

Hi i am new to CAESAR In my model i have one spring hanger vertical at one node. When i view my results , it shows in load case analyzed 1) (HGR) CASE NOT ACTIVE 2) (HGR) CASE NOT ACTIVE whats the meaning of this "(HGR) CASE NOT ACTIVE" Regards

September Su M Tu W Th F 1 8 2 3 4 5 6 9 10 11 12 13

15 16 17 18 19 20 22 23 24 25 26 27 29 30 Forum Stats 9395 Members 13 Forums 11968 Topics 54219 Posts


Max Online: 57 @

Top

Re: Analysis using Hanger [Re: Engr_mech] Nald


Member

#37450 - 08/16/10 02:38 AM

12/06/09 11:14 AM

It means hanger load cases are not viewable in the report. If you want it to be Registered: viewable, go to Load Case Options in 02/20/09 Static Load Case Editor, and under Output Posts: 119 Loc: Status column, change it to "keep".
Malaysia

Edited by Nald (08/16/10 02:39 AM)

_________________________ Regards, Nald


Top

Re: Analysis using Hanger [Re: Nald] Engr_mech


Member Registered: 06/01/10 Posts: 64 Loc: Australia

#37452 - 08/16/10 03:06 AM

Nald Thank you very much. Regards