You are on page 1of 6

Discharge Rate (Design)

W=

106.67 Kg/sec

Bulk Density of Material

r=

800 Kg/m

Accleration due to gravity

g=

9.81 m/sec2

Constant

K=

384 TPH
0.8 T/m3

1.4

Lump Size / Particle Size

dp =

0.05 m

50 mm

Outlet size

B=

0.70 m

700 mm

Angle of Hopper from Vertical

q=

30 deg.

Beverloo Eqn. for Funnel Flow

W = 0.58 . r . g 0.5 . ( B - K . Dp ) 2.5

W=

457.8 Kg/sec

Johanson Eqn. for Mass Flow for Circular Outlet

W = r . p / 4 . B 2 . ( g . B / 4 . tan q ) 0.5

W=

530.9 Kg/sec

30 deg.

D1 = 18000 mm dia

6302 mm
35.0 deg

H1

12000 mm
H2
33241 mm

14939 mm
60.0 deg

D2 =

Capacity =

750 mm dia
0.8 T/m3

Bulk Density =
Volume =

H3

1
2
3

1/3 x (p/4 x D2) x H1 =


(p/4 x D2) x H2 =
2
2
0.262 x (D1 + D2 + D1 x D2) x H3 =
Total Volume =
3929.04 Ton

534.49
3053.64
1323.18
4911.30

m3
m3
m3
m3

B1=

6000 mm

L1=

6000 mm

2101 mm
35.0 deg

H1

0 mm
H2
5671 mm

3570 mm
55.0 deg

B2=

Capacity =

L2=

1000 mm

0.8 T/m3

Bulk Density =
Volume =

1000 mm

H3

1
2
3

1/3 x B1 x L1 x H1=
B2 x L2 x H2 =
H/6.(2.B1.L1 + 2.L2.B2 + B1.L2 + B2.L1) =
Total Volume =
56.78 Ton

19.80
0.00
51.18
70.97

m3
m3
m3
m3

B1=

6000 mm

L1=

5000 mm

4201 mm
35.0 deg

H1

0 mm
H2
7772 mm

3570 mm
55.0 deg

B2=

Capacity =

L2=

1000 mm

0.8 T/m3

Bulk Density =
Volume =

1000 mm

H3

1
2
3

1/3 x B1 x L1 x H1=
B2 x L2 x H2 =
H/6.(2.B1.L1 + 2.L2.B2 + B1.L2 + B2.L1) =
Total Volume =
66.43 Ton

39.59
0.00
43.44
83.03

m3
m3
m3
m3

D1 = 18000 mm dia

12000 mm
H1
27155 mm

15155 mm
60.0 deg

D2 =

Volume =

1
2

H2

500 mm dia

(p/4 x D12) x H1 =
0.262 x (D12 + D22 + D1 x D2) x H2 =
Total Volume =

3053.64 m3
1323.24 m3
4376.88 m3

B1 =

18000 mm

L1 =

18000 mm

12000 mm
H1
27155 mm

15155 mm
60.0 deg

B2 =

Volume =

1
2

500 mm

L2 =

H2

500 mm

B1 x L1 x H1 =
H/6.(2.B1.L1 + 2.L2.B2 + B1.L2 + B2.L1) =
Total Volume =

3888.00 m3
1683.52 m3
5571.52 m3

You might also like