TURBOMAX (DHW AND BUFFER TANK ) AND MODULATING CONDENSING BOILER

BOILER
COMBUSTION CHAMBER

MODULATING CONDENSING

PRESSURE REDUCING VALVE 15 PSI

BACK FLOW PREVENTER EXPANSION TANK BOILER WATER EXTROL #60 AIR VENT
VACUUM BREAKER

POTABLE COLD WATER 40F ____" DIA.

PUMP ___ GPM @ ___ FTHD __________ #_________ SPACE HEATING ZONE VALVES ____" DIA.

EXPANSION TANK POTABLE WATER THER-X-TROL #ST-5

SPACE HEATING RETURN

CHECK VALVE ____" DIA.


M M M

THERMOSTATIC MIXING VALVE POTABLE HOT WATER 120F HONEYWELL 3/4 INCH #AM-101-US ____" DIA. ____" DIA.

POTABLE HOT WATER

AQ

BUTT TEES TOGETHER

TURBOMAX 33

REQUIREMENTS: 1. THE INSTALLATION MUST CONFORM TO LOCAL, STATE, PROVINCIAL, NATIONAL CODES. IN ANY CASE WHERE INSTRUCTIONS CONFLICT WITH THE ABOVE, LET THOSE CODES TAKE PRECEDENCE. 2. THIS IS A BASIC PIPING SCHEMATIC. PLEASE CONSULT THE INSTALLATION MANUAL. 3. INSTALL A SAFETY VALVE (TEMPERATURE & PRESSURE) ON THE DOMESTIC HOT WATER LINE, THE NEAREST POSSIBLE TO THE HOT WATER HEATER CONNECTION AND BEFORE ANY SHUT OFF VALVE. 4. PIPE ALL THE SAFETY VALVES AND DRAIN VALVES TO THE DRAIN OR ACCORDINGLY TO THE CODE. 5. WHEN A BACK FLOW PREVENTER OR WATER METER OR A PRESSURE REDUCING VALVE IS USED ON THE DOMESTIC COLD WATER SUPPLY LINE, THEN A THERMAL EXPANSION TANK MUST BE INSTALLED BETWEEN THE WATER HEATER AND THIS DEVICE. 6. AUTOMATIC AIR VENT MUST BE INSTALLED ON BOILER WATER PIPING WHEREVER PIPING TURNS DOWNWARD FOLLOWING AN UPWARD OR A HORIZONTAL RUN.

DRAWING: 1T_1B_ZONE VALVES

THERMOSTATIC MIXING VALVE VALVE DRAIN COCK UNION AQ

CHECK VALVE BACK FLOW PREVENTER TURBOMAX AQUASTAT

AUTOMATIC AIR VENT T THERMOMETER PRESSURE RELIEF VALVE

THERMO 2000 INC. 500, 9TH AVENUE RICHMOND (QC) JOB 2H0 TEL: 819 826-5613 FAX: 819 826-6370