Design of spread footing

F7 Working column load Footing weight (Percent of column load) Allowable bearing capacity Column length Column width length-width = = = = = = 441.4 0.05 20 80 80 0 ton (0.05-0.10) t/m2 cm cm m

Area of Plain Footing Width of footing Length of footing Chosen width of foorting Chosen length of foorting Thickness of plain concrete

= = = = = =

23.1735 4.813886 4.813886 4.9 4.9 0.4

m2 m m m m m

Reinforced Concrete footing Width of footing Length of footing contact stress Minimum thickness of footing Chosen thickness of footing Net stress on soil Fs allowable As long Moment Total As long choose phi # of bars/meter spacing between bars As short Moment Total As short choose phi # of bars/meter spacing between bars Check one way shear Shear stress in long direction Shear stress in short direction Check two way shear perimeter area punched shear stress

= = = = = = =

4.1 4.1 26.25818 56.71821 60 18.83806 2200

m m t/m2 < cm cm t/m2 kg/cm2

50 t/m2

= = = = = = = = = =

35.74395 36.06492 2.5 7.4 13.60394 35.74395 36.06492 2.2 9.5 10.5

mt cm2 cm 0 cm mt cm2 cm bars cm

= =

70.2 70.2

ton/m2 ton/m2

= = =

5.28 1.7424 74.9

m m2 ton/m2