You are on page 1of 3

COOKING

Range Backguard Control Panel Discoloration

TS
Bulletin

MODELS: JGR8855ADS, JGR8750ADB JGR8850ADB, JGR8750ADQ JGR8850ADQ, JGR8750ADW JGR8850ADW, MGR5870ADB MGR5870ADQ, MGR5870ADW

30 Inch Free Standing Self-Cleaning Gas Range, Cleveland Produced

PRODUCT TYPE:

696
2/01

CONDITION Backguard and control panel discoloration/melting. CAUSE The discoloration is caused by excessive heat vented from the oven to the top surface of the range. The vents are located below the control panel at the front of the lower backguard and control panel. CORRECTION If you should encounter complaints concerning the discoloration/melting of the backguard and control panel, a heat shield is now available to correct this condition. Order appropriate heat shield kit and control panel for corresponding model listed above. For the gray heat shield order part number 12001256 and for the black shield order part number 12001257. NOTE: The heat shield can be ordered separately if needed. The part number is 74002198 for gray, and part number 74002199 for black. Maytag Jenn-Air

Continued...

Instruction Sheet
This instruction sheet is to be used with:

16007570

REPAIR PART NO.: DESCRIPTION:

12001256, 12001257 Heat Shield Kit HEAT SHIELD INSTALLATION INSTRUCTION (BACKGUARDS/CONTROL PANEL DISCOLORATION)

CONTENTS:

74002198 Heat Shield (1)

Control Panel (1 or 2) {Qty. & Style vary by Model & Kit} 16010442 Instruction Sheet

NOTE: Before installing heat shield, replace the backguard control panel. (Due to different clock configurations, some kits may contain more than one control panel.)

1. 2. 3.

Disconnect electrical supply and gas supply before servicing the appliance. Remove (3) screws that secure sight shield to backguard assembly (see illustration next page). Insert right end of heat shield through the sight opening between the backguard assembly and the range main back. Position the heat shield as far right as possible and pivot left end of heat shield into position (as illustrated next page). Align heat shield mounting holes with existing screw holes for sight shield, position sight shield back into place and attach shield to backguard assembly, using existing screws. Reconnect gas supply, and check for gas leaks. Reconnect electrical supply and check range for proper operation. Instruction Sheet 16007570 Reissued 11/95 TS696 Continued...

4.

5. 6.