You are on page 1of 9

http://www7.nationalacademies.org/spanishbeyonddiscovery/bio_007590-03.html http://www.investigacionesmedicas.com/estudios_rnm_campoalto.php http://estaticos.elmundo.es/elmundosalud/documentos/2003/10/mri.swf http://www.amdsalud.com.ar/departamentos.php http://www.cis.rit.edu/htbooks/mri/chap-8/chap-8-s.htm (libro muy utli) http://www.cis.rit.edu/htbooks/mri/chap-7/chap-7-s.htm http://www.cis.rit.edu/htbooks/mri/chap-5/chap-5-s.htm#5.8 http://www.cis.rit.edu/htbooks/mri/chap-2/chap-2-s.htm#2.

http://www.cis.rit.edu/htbooks/mri/index.html

http://www.cis.rit.edu/htbooks/mri/inside.htm

References

E. Fukushima and S.B.W. Roeder, Experimental Pulse NMR, Addison-Wesley, Reading, MA 1981. T.C. Farrar, An Introduction To Pulse NMR Spectroscopy, Farragut Press, Chicago, 1987. R.C. Jennison, Fourier Transforms and Convolutions, Pergamon Press, NY 1961. E.O.Brigham, The Fast Fourier Transform, Prentice-Hall, Englewood Cliffs, NJ 1974. A. Carrington and A.D. McLachlan, Introduction To Magnetic Resonance, Chapman and Hall, London 1967. B. Noble and J.W. Daniel, Applied Linear Algebra, Prentice-Hall Englewood Cliffs, NJ. G.B. Thomas, Calculus, Addison-Wesley, Reading, MA 1969. D.D. Stark and W.G. Bradley, Magnetic Resonance Imaging, C.V. Mosby Co., St. Louis, MO 1988. R.K. Harris, Nuclear Magnetic Resonance Spectroscopy, Pitman, London 1983. T.C. Farrar and E.D. Becker, Pulse And Fourier Transform NMR, Academic Press, 1971. D. Shaw, Fourier Transform NMR Spectroscopy, Elsevier, NY 1976. J.W.Akitt, NMR and Chemistry, An Introduction to the Fourier Transform - Multinuclear Era. Chapman and Hall, London, 1983.

R. Freeman, A Handbook of Nuclear Magnetic Resonance, Longman Scientific & Technical, Essex, England, 1988. J.S. Leigh, FDA Safety Guidelines for MRI Devices." Resonance Newsletter SMRM 20:9 (1990) S.R. Deans, S. Roderick, The Radon Transform and Some of its Applications. Wilwy, NY 1983. L.M. Fletcher, J.B. Barsotti, J.P. Hornak, "A Multispectral Analysis of Brain Tissues." Magn. Reson. Med. 29:623-630 (1993). J. Szumowski, D. B. Plewes, "Separation of Lipid and Water MR Imaging Signals by Chopper Averaging in the Time Domain." Radiology 165:247-250 (1987). P.G. Lauterbur, Nature 242:190-191 (1973). A. Kumar, D. Welti, R.R. Ernst, J. Magn. Reson. 18:69-83 (1975); Naturwissenschaften 62: 34 (1975) D.G. Nishimura, Magn. Reson. Med. 14:194-201 (1990). C.L. Dumoulin, S.P. Souza, M.F. Walker, W. Wagle, Magn. Reson. Med. 9:139-149 (1989). F. Forzaneh, S.J. Riederer, N.J. Pelc, Magn. Reson. Med. 14:123-139 (1990). H. Bruder, H. Fischer, H.E. Reinfelder, F. Schmitt, Magn. Reson. Med. 23:311-323 (1992). P.A. Bandettini, A. Jesmanowicz, E.C. Wong, J.S. Hyde, Magn. Reson. Med. 30:161-173 (1993). S.L. Smith, Anal. Chem. 57:A595-A607 (1985). C.E. Hayes, W.A. Edelstein, J.F. Schenck, "Radio Frequency Resonators." in Magnetic Resonance Imaging, ed. by C.L. Partain, R.R. Price, J.A. Patton, M.V. Kulkarni, A.E. James, Saunders, Philadelphia, 1988. G.M. Bydder, "Clinical Applications of Gadolinium-DTPA." in in Magnetic Resonance Imaging, ed. by D.D. Stark and W.G. Bradley, C.V. Mosby Co., St. Louis, MO 1988. J. Granot, "Selected volume excitation using stimulated echoes (VEST). Applications to spatially localized spectroscopy and imaging." J. Magn. Reson. 70:488-492 (1986). S.R. Thomas, L.J. Busse, J.F. Schenck, "Gradient Coil Technology." in Magnetic Resonance Imaging, ed. by C.L. Partain, R.R. Price, J.A. Patton, M.V. Kulkarni, A.E. James, Saunders, Philadelphia, 1988. M.R. Bendall, "Surface Coil Technology." in Magnetic Resonance Imaging, ed. by C.L. Partain, R.R. Price, J.A. Patton, M.V. Kulkarni, A.E. James, Saunders, Philadelphia, 1988. C.E. Hayse, W.A. Edelstein, J.F. Schenck, O.M. Mueller, M. Eash, "An Efficient Highly Homogeneous Radiofrequency Coil for Whole-Body NMR Imaging at 1.5T." J. Magn. Reson. 63:622-628 (1985). J.P. Hornak, J. Szumowski, R.G. Bryant, "Elementary Single Turn Solenoids Used in the Transmitter and Receiver in Magnetic Resonance Imaging." Magn. Reson. Imag. 5: 233237(1987). J. Eng, T.L. Ceckler, R.S. Balaban, Magn. Reson. Med. 17:304-314 (1991). J. Gong and J.P. Hornak, "A Fast T1 Algorithm." Magn. Reson. Imaging 10:623-626 (1992). X. Li and J.P. Hornak, "T2 Calculations in MRI: Linear versus Nonlinear Methods." J. Imag. Sci. & Technol. 38:154-157 (1994). Y. Chen, E. Dougherty, S.M. Totterman, J.P. Hornak, "Classification of Trabecular Structure in Magnetic Resonance Images Based on Morphological Granulometries." Magn. Reson. Med. 29:358-370 (1993). M.S. Albert, G.D. Cates, B. Driehuys, W. Happer, B. Saam, C.S. Springer Jr., A. Wishnia, "Biological magnetic resonance imaging using laser-polarized 129Xe." Nature 370:199-201 (1994).

S.D. Swanson, M.S. Rosen, B.W. Agranoff, K.P. Coulter, R.C. Welsh, T.E. Chupp, "Brain MRI with Laser-Polarized 129Xe." Magn. Reson. Med. 38:695-698 (1997). Handbook of Chemistry and Physics, 53 ed., ed. by R.C. Weast, Chemical Rubber Company, Cleveland, Ohio, 1972. M.A. Foster, Magnetic Resonance in Medicine and Biology, Pergamon Press, New York, 1984. J.E. Roe, W.E. Prenttice, J.P. Hornak, A Multipurpose MRI Phantom Based on a Reverse Micelle Solution. Magn. Reson. Med. 35:136-141 (1996). J.P. Hornak, J. Szumowski, R.G. Bryant, Magnetic Field Mapping. Magn. Reson. Med. 6:158163 (1988). J.P. Hornak, E. Marshall, J. Szumowski, R.G. Bryant, MRI of Extremities using Perforated Single Turn Solenoids, Magn. Reson. Med. 7:442-448 (1988). J.P. Hornak, J. Szumowski, D. Rubens, J. Janus, R.G. Bryant, Breast MR Imaging With LoopGap Resonators, Radiology 161:832-834 (1986). E.A. Marshall, J.J. Listinsky, T.L. Ceckler, J. Szumowski, R.G. Bryant, J.P. Hornak, Magnetic Resonance Imaging Using a Ribbonator: Hand and Wrist, Magn. Reson. Med. 9:369-378 (1989). S.D. Szeglowski, J.P. Hornak, Asymmetric Single-Turn Solenoid for MRI of the Wrist, Magn. Reson. Med.30:750-753 (1993). T.J. Meade, W.-h. Li, S.E. Fraser, A Calcium-Sensitive Magnetic Resonance Imaging Contrast Agent, >J. Am. Chem. Soc. 121:1413 (1999). J. Frahm, K.D. Merboldt, W. Hanicke; "Localized proton spectroscopy using stimulated echoes." J. Magn. Reson.72:502 (1987). P.A. Bottomley; "Spatial localization in NMR spectroscopy in vivo." Ann. NY Acad. Sci.508:333 (1987). R.J. Ordidge, A. Connelly, J.A.B. Lohman; "Image-selected in vivo spectroscopy (ISIS): a new technique for spatially selective NMR spectroscopy." J. Magn. Reson.66:283 (1986). P.A. Bottomley, T.B. Foster, R.D. Darrow; "Depth-resolved surface coil spectroscopy (DRESS) for in vivo 1H, 31P, and 13C NMR." J. Magn. Reson.59:338 (1984).< T.R. Brown, B.M. Kincaid, K. Ugurbil; "NMR chemical shift imaging in three dimensions." Proc. Natl. Acad. Sci. USA, 79:3523 (1982). R.E. Gordon, P.E. Hanley, D. Shaw; "Topical Magnetic Resonance." Prog. NMR Spect. 15:1 (1982). J.P. Hornak, J.K. Moscicki, D.J. Schneider, J.H. Freed; "Diffusion coefficients in anisotropic fluids by ESR imaging." J. Chem. Phys. 84:3387-3395 (1986). G.B. Matson, M.W. Weiner; "Spectroscopy", Chapter 15, Pages 438-477 In: Magnetic Resonance Imaging, D.D. Stark & W.G. Bradley, Jr., Mosby Year Book, St. Louis, 1992. J.J.H. Ackerman, T.H. Grove, G.G. Wong, et al.; "Mapping of metabolites in whole animals by 31P NMR using surface coils." Nature 283: 167 (1980) W. Chen, J.J.H. Ackerman; "Surface coil single-pulse localization in vivo via inhomogeneous surface spoiling magnetic gradient." NMR Biomed. 4: 205 (1989) Y. Geoffrion, M. Rydzy, K.W. Butler, et al.; "The use of immobilized ferrite to enhance the depth selectivity of in vivo surface coil NMR spectroscopy." NMR Biomed. 1: 205 (1988) P.C. Lauterbur, D.N. Levin, R.B. Marr; "Theory and Simulation of NMR Spectroscopic Imaging and Field Plotting by Projection Reconstruction Involving an Intrinsic Frequency Dimension." J. Magn. Reson. 59: 536-541 (1984).

T.G. Servoss, J.P. Hornak; "Spatial-spatia-spectral imaging using a clinical MRI." Experimental NMR Conference, Asilomar, CA, April 2000. G.N. Hounsfield; "Computerized transverse axial scanning (tomography)." Br. J. Radiol. 46:1016-1022 (1973). R.V. Damadian; "Tumor Detection by Nuclear Magnetic Resonance." Science 171:1151 (March 19, 1971). P Mansfield; "Multi-planar image formation using NMR spin-echos." J. Phys. C: Solid State Physics 10:L55-L58 (1977). J. Frahm, K.D. Merboldt, W. Hanicke; "Functional MRI of Human Brain Activation at High Spatial Resolution." Magn. Reson. Med. 29:139-144 (1993). B. Chapman, R. Turner, R.J. Ordidge, M. Doyle, M. Cawley, R. Coxon, P. Glover, P. Mansfield; "Readl-Time Movie Imaging from a Single Cardiac Cycle by NMR." Magn. Reson. Med. 5:246-254 (1987). C.L. Dumoulin, S.P. Souza, H.R. Hart; "Rapid Scan Magnetic Resonance Angiography." Magn. Reson. Med. 5:238-245 (1987). Guidance for the Submission Of Premarket Notifications for Magnetic Resonance Diagnostic Devices; November 14, 1998; (Supersedes the Guidance for the Content and Review Of a Magnetic Resonance Diagnostic Device 510(k) Application (8/2/88).); U.S. Department Of Health and Human Services, Food and Drug Administration; Document 340 Criteria for Significant Risk Investigations of Magnetic Resonance Diagnostic Devices; July 14, 2003; (Supersedes Guidance for Magnetic Resonance Diagnostic Devices Criteria for Significant Risk Investigations (9/29/1997).); U.S. Department of Health and Human Services, Food and Drug Administration; Document 793 G. Morrow; "Progress In MRI Magnets"; Intermagnetics General Corporation, Latham, New York, USA http://www.igc.com/mbg/rd/Mt16paper1Color.pdf Jaques-Arsne d' Arsonval; 1896 R. D. Watkins; "Quadrature Coil Postion Invariant to Bo"; Proceeding of the ISMRM, 11th Scientific Meeting; Toronto, Ontario, Canada, July 2003; #2361 M.L. Buess, A.N. Garroway, J.B. Miller; "Detection of explosives by nuclear quadrupole resonance." US Patent 5,206,592; May 18, 1999 E.A. Marshall, J.J. Listinsky, T.L. Ceckler, J. Szumowski, R.G. Bryant, J.P. Hornak; "Magnetic Resonance Imaging Using a Ribbonator: Hand and Wrist."; Magn. Reson. Med. 9:369-378 (1989). T. Munsat, W. M. Hooke, S. P. Bozeman, S. Washburnd; "Two new planar coil designs for a high pressure radio frequency plasma source." Appl. Phys. Lett. 66 :2180-2182 (1995). D.W. Alderman, D.M. Grant; "An efficient decoupler coil design which reducesheating in conductive samples in superconducting spectrometers." J. Magn. Reson. 36 :447-451 (1979). H.J. Schneider, P. Dullenkopf; "Slotted tube resonator: A new NMR probe head at high observing frequencies." Rev. Sci. Instrum. 48:68-73 (1977). D. Belohrad, http://www.isibrno.cz/~belohrad/ ; "Large Saddle Coil Design." In Proceedings of the 10th International Conference Radioelectronics 2000; Bratislava, Slovak Republic, 2000. http://www.isibrno.cz/~belohrad/poster2000-poster-coil.pdf D. Belohrad, M. Kasal; "Saddle Coil for MRI"; In Proceedings of the 10th International Conference Radioelectronics 2000Bratislava, Slovak Republic, 2000. http://www.isibrno.cz/~belohrad/radioelektronika2000-saddlecoilformri.pdf F.D. Doty, G. Entzminger, C.D. Hauck; "Error-Tolerant RF Litz Coils for NMR/MRI." J. Magn. Reson. 140:17-31 (1999).

F.D. Doty; "Low Inductance Transverse Litz Foil Coils." U.S. Patent #6,060,882 F.D. Doty, G. Entzminger, Z. Rafique, L. Holte, T. Welsh; "The Litzcage - a High-field Circular-polarized RF Coil with Improved Tunability, B1 Homogeneity, and S/N." http://www.dotynmr.com/images/documents/RFLC__000.pdf T.M. Grist, J.S. Hyde; "Resonators for in-vivo phosphorous-31 NMR at 1.5 T." J. Magn. Reson. 61:571-578 (1985). J.B. Kneeland, A. Jesmanowicz, W. Froncisz, T.M. Grist, J.S. Hyde; "High-resolution localized magnetic resonance imaging using loop-gap resonator pairs."Radiology 158:247-250 (1986). T.M. Grist, A. Jesmanowicz, J.S. Hyde; Magn. Reson. Med. 3:135 (1986). A.J. Martin, D.B. Plewes, R.M. Henkelman; "MR imaging of blood vessels with an intravascular coil." J. Magn. Reson. Imag. 2:421-429 (1992). E. Atalar, P.A. Bottomley, O. Ocali, L.C.L Coreia, M.D. Kelemen, J.A.C. Lima, E.A. Zerhouni; "High Resolution Intravascular MRI and MRS by Using a Catheter Receiver Coil."Magn. Reson. Med. 36:596-605 (1996). O. Ocali, E. Atalar; "Intravascular Magnetic Resonance Imaging Using a Loopless Catheter Antenna." Magn. Reson. Med. 37:112-118 (1997). K.L. Meyer, D. Ballon;"A 3x3 mesh two-dimensional ladder resonator for MRI of the human head." J. Magn. Reson. 107B:19-24 (1995). K.L. Meyer, K. Kim, T.Li, P.K. Tulipano, K.-M. Lee, R. DeLaPaz, J. Hirsch, D. Ballon; "Sensitivity-enhanced echo-planat MRI at 1.5T using a 5x5 mesh dome resonator." Magn. Reson. Med. 36:606-612 (1996). R. Black, T. Early, P. Roemer, O. Mueller, A. Mogro-Campero, L. Turner, G. Johnson; "A High-Temperature Superconducting Receiver for Nuclear Magnetic Resonance Microscopy." Science 259: 793 (1993). R. S. Withers, B. F. Cole, M. E. Johansson, G.-C. Liang, G. Zaharczuk; "High-Temperature Superconductor Receiver Coils for Magnetic-Resonance Instruments." SPIE Proc., High-Tc Microwave Superconductors and Applications 2156: 27-35 (1994). S. E. Hurlston, W. W. Brey, S. A. Suddarth, G. A. Johnson; "A High-Temperature Superconducting Helmholtz Probe for Microscopy at 9.4 T," Magn. Reson. Med. 41:1032 (1999). J. Wosik, K. Nesteruk, F. Wang, L.-M. Xie, M. Strikovski, M. Kamel, M. Bilgen, P. A. Narayana; "High-Tc Superconducting rf Receiver Coils for Magnetic Resonance Imaging of Small Animals." Physica C 341-348:2561-2564 (2000). Schlumberger Limited, Houston, TX, http://www.slb.com/seed/en/watch/nmr/tool.htm" R.L. Kleinberg, D.D. Griffin, M. Fukuhara, A. Sezginer, and Schlumberger Technology Corporation (New York, NY); Borehole measurement of NMR characteristics of earth formations. U.S. Patent #5,055,788; 8 October 1991 C.A. Meriles, D. Sakellariou, H. Heise, A.J. Moul, A. Pines; "Approach to High-Resolution ex Situ NMR Spectroscopy." Science 293: 82-85 (2001). NMRMOUSE is a trademark of the RWTH-Aachen, Germany. See also: http://www.mpipmainz.mpg.de/~bluemler/mouse/ G. Eidmann, R. Savelsberg, P. Blmler, B. Blmich; "The NMR MOUSE, a Mobile Universal Surface Explorer." J. Magn. Reson. 122:104-109 (1996). P. J. Prado, B. Blmich, U. Schmitz; "One-Dimensional Imaging with a Palm-Size Probe." J. Magn. Reson. 144:200-206 (2000).

S. Anferova, V. Anferov, M. Adams, P. Blmler , N. Routley, K. Hailu, K. Kupferschlger, M. J. D. Mallett, G. Schroeder, S. Sharma, B. Blmich; "Construction of an NMR-MOUSE With Short Dead Times." Concepts in Magn. Reson. (Magn. Reson. Eng.) 15:15-25 (2002). Y. Zhu, C. Hardy, R. Giaquinto, K. Rohling, C. Dumoulin, D. Sodickson, M. Ohliger, R. Darrow, G. Kenwood; "Highly Parallel Volumetric Imaging with Accelerated Spatial Encoding along Two Dimensions." Proceedings of the 11th ISMRM, Toronto, Ontario, Cnada (2003) P.B. Roemer, W.A. Edelstein, C.E. Hayes, A.P. Souza, O.M. Mueller; "The NMR Phased Array" Magn. Reson. Med. 16:192-225 (1990). D.K. Sodickson, W.J. Manning; "Simultaneous acquisition of spatial harmonics (SMASH) Fast imaging with radiofrequency coil arrays." Magn. Reson. Med. 38:591-603 (1997). Y. Zhu, C.J. Hardy, R.O. Giaquinto, K.W. Rohling, C.L. Dumoulin, D.K. Sodickson, M.A. Ohliger, R.D. Darrow, G. Kenwood; Highly parallel volumetric imaging with accelerated spatial encoding along two dimensions. Proceedings of the ISMRM, 11th Scientific Meeting, p. 22, 2003. W.A. Wagle; "Tattoo-Induced Burn During MR Imaging." Amer. J. of Roentgenology 174:1795 (2000). M.L. Kreidstein, et al; "MRI Interaction with Tattoo Pigments: Case Report, Pathophysiology, and Management." Plast. Reconstr. Surg. 99:117-1720 (1997). M. Vahlensieck; "Tattoo-related cutaneous inflammation (burn grade I) in mid-field MR scanner." European Radiology 10:197 (2000). W.D. Tope, F.G. Shellock; "Magnetic Resonance Imaging and Permanent Cosmetics (tattoos): Survey of Complications and Adverse Events." J. Magn. Reson. Imaging. 15:180184 (2002). "MRI Facts." The Society of Permanent Cosmetic Professionals (2002). http://www.spcp.org/MRIinfo.htm E. Kanal, F.G. Shellock; "Burns Associated with Clinical MR Examinations." Radiology 175:585 (1990). G. Lund, et al; "Tattooing of Eyelids: Magnetic Resonance Imaging Artifacts." Ophthalmic Surgery 17:550-553 (1986). R.A. Weiss, et al; "Mascara and Eyelining Tattoos: MRI artifacts." Annals of Ophthalmology. 21:129-131 (1989). D.K. Sodickson, W.J. Manning; "Simultaneous acquisition of spatial harmonics (SMASH) Fast imaging with radiofrequency coil arrays." Magn. Reson. Med. 38:591-603 (1997). T. Wu, J.P. Felmlee, J.F. Greenleaf, S.J. Riederer, R.L. Ehman; "MR imaging of shear waves generated by focused ultrasound." Magn. Reson. Med. 43:111-5 (2000). R. Muthupillai, R.L. Ehman; "Magnetic resonance elastography." Nature Medicine 2:601-3 (1996). R. Muthupillai, D.J. Lomas, P.J. Rossman, J.F. Greenleaf, A. Manduca, R.L. Ehman; "Magnetic resonance elastography by direct visualization of propagating acoustic strain waves." Science 269:1854-7 (1995). J.E. Wertz, J.R. Bolton; "Electron Spin Resonance Elementary Theory and Practical Applications." Chapman and Hall, NY (1986). C.P. Poole, Jr.; "Electron Spin Resonance." John Wiley & Sons, NY (1983). H.B. Suits, A.N. Garroway; Optimizing surface coils and the self-shielded gradiometer. Journal of Applied Physics, 94:4170-4178 (2003). B.H. Suits, A.N. Garroway, J.B. Miller; Noise-imune coil for unshielded magnetic resonance measurements. J. Magn. Reson., 131:154-158 (1998).

N. Baril, E. Thiaudiere, B. Quesson, C. Delalande, P. Canioni, J.-M. Franconi; Surface-coil surface imaging using a radiofrequency field gradient.J. Magn. Reson., 146:223-227 (2000). V.S. Grechishkin; NQR Device for detecting plastic explosives, mines, and drugs. Appl. Phys., A55:505-507 (1992). M.C.K.Wiltshire, J.B. Pendry, I.R. Young, D.J. Larkman, D.J. Gilderdale, J.V. Hajnal; Microstructured magnetic materials for RF flux guides in magnetic resonance imaging.Science, 291:849-851 (2001). L. Renaud, M. Armenean, L. Berry, P. Kleimann, P. Morin, M. Pitaval, J. OBrien, M. Brunet, H. Saint-Jalmes; Implantable planar rf microcoils for NMR microspectroscopy. Sensors and Actuators, A99:244-248 (2002). M.A. Foster; Magnetic Resonance in Medicine and Biology, Pergamon Press Oxford, 1984. B.Halliwell, J.M.C. Gutteridge; Free Radicals in Biology and Medicine, Clarendon Press, Oxford, 1989. J.B. Ra, C.Y. Rim; "Fast imaging using subencoding data sets from multiple detectors." Magn. Reson. Med. 30:142145 (1993). M. Hutchinson, U. Raff; "Fast MRI data acquisition using multiple detectors." Magn. Reson. Med. 6:8791 (1988). K.P. Pruessmann, M. Weiger, M.B. Scheidegger, P. Boesiger; "SENSE: sensitivity encoding for fast MRI." Magn. Reson. Med. 42:952962 (1999). D. Larkman, J. Hajnal, A. Herlihy, G. Coutts, I. Young, G. Ehnholm; "Use of multicoil arrays for separation of signal from multiple slices simultaneously excited." J Magn Reson Imag 13:313317 (2001). D.K. Sodickson, W.J. Manning; "Simultaneous acquisition of spatial harmonics (SMASH): ultra-fast imaging with radiofrequency coil arrays." Magn. Reson. Med. 38:591603 (1997). D.K. Sodickson; Tailored SMASH image reconstructions for robust in vivo parallel MR imaging. Magn. Reson. Med. 44:243251 (2000). P.M. Jakob, M.A.Griswold, R.R Edelman, D.K. Sodickson; AUTO-SMASH: a self-calibrating technique for SMASH imaging. Simultaneous acqui-sition of spatial harmonics. MAGMA 7:4254 (1998). W.E. Kyriakos, L.P. Panych, D.F. Kacher, C.F. Westin, S.M. Bao, R.V. Mulkern, F.A. Jolesz; "Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP)." Magn. Reson. Med. 44:301308 (2000).

K.K Kwong, J.W. Belliveau, D.A. Chesler, I.E. Goldberg, R.M. Weisskoff, B.P. Poncelet, D.N. Kennedy, B.E. Hoppel, M.S. Cohen, R. Turner, H.-M Cheng, T.J. Brady, B.R. Rosen; Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation. Proc. Natl. Acad. Sci. (USA) , 89:5675 (1992).
P.A. Bandettini, E.C. Wong, R.S. Hinks, R.S. Tikofsky, J.S. Hyde; "Time course EPI of human brain function during task activation." Magn. Reson. Med. 25:390-397 (1992). H.E. Mller, D.Y. von Cramon, "Survey of risks related to static magnetic fields in ultra high field MRI." Rofo. 180(4):293-301 (2008). M.I. Weintraub, A. Khoury, S.P. Cole; "Biologic Effects of 3 Tesla (T) MR Imaging Comparing Traditional 1.5 T and 0.6 T in 1023 Consecutive Outpatients." Journal of Neuroimaging 17:241-245 (2007). J.F. Schenk, "Physical interactions of static magnetic fields with living tissues." Progress in Biophysics and Molecular Biology 87:185-204 (2005).

F. de Vocht, H. van Drooge, H. Engels, H. Kromhout; "Exposure, health complaints and cognitive performance among employees of an MRI scanners manufacturing department." Journal of Magnetic Resonance Imaging 23:197-204 (2006). P.M. Glover, I. Cavin, W. Qian, R. Bowtell, P.A. Gowland; "Magnetic-field-induced vertigo: a theoretical and experimental investigation." Bioelectromagnetics 28(5):349-61 (2007). A.K. Silva, E.L. Silva, E.S. Egito, A.S. Carrio; "Safety concerns related to magnetic field exposure." Radiat Environ Biophys 45(4):245-52 (2006). J.A. Stringer, C.E. Bronnimann, C.G. Mullen, D.H. Zhou, S.A. Stellfox, Y. Li, E.H. Williams, C.M. Rienstr; "Reduction of RF-induced sample heating with a scroll coil resonator structure for solid-state NMR probes." J. Magn. Reson. 173(4):40-48 (2005). W. Krause, Contrast Agents I: Magnetic Resonance Imaging, Springer, Berlin 2001. D.H. Gultekin, T.E. Raidy, J.C. Gore; "Effects of radiation on the NMR relaxation effects of aqueous solutions of gadolinium contrast agents." Contrast Media Mol Imaging 4:3336 (2009) M.F. Tweedle; "The ProHance story: the making of a novel MRI contrast agent." European Radiology 7:S225-S230 (1997) Omniscan Data Sheet, Nycomed - GE Healthcare C. de Han, M. Cabrini, L. Akhnana, D. Ratti, L. Calabi, L. Gozzini, "Gadobenate dimeglumine 0.5 M solution for injection (MultiHance): pharmaceutical formulation and physicochemical properties of a new magnetic resonance imaging contrast medium." J Comput Assist Tomogr 23(suppl 1):S161-S168 (1999) S.Y. Moon, J.P. Hornak; "A volume resolution phantom for MRI." Magnetic Resonance Imaging 28:286-289 (2010). P. S. Tofts, "Standing waves in uniform water phantoms." Magn. Reson. Imaging 104B:143-147 (1994). P.S.Tofts, D. Lloyd, C.A. Clark, G.J. Barker, G.J.M. Parker, P. McConville, C. Baldock, J.M. Pope; "Test Liquids for quantitative MRI measurements of self-diffusion coefficient in vivo." Magnetic Resonance in Medicine 43:368-374 (2000). C. Poupon, B. Rieul, I. Kezel, M. Perrin, F. Poupon, J.-F. Magin; "New Diffusion Phantoms Dedicated to the Study and Validation of High-Angular-Restricted Diffusion Imaging (HARDI) Models." Magnetic Resonance in Medicine 60:1276-1283 (2008). H. Kim, S.E. Taksali, S. Dufour, D. Befroy, T.R. Goodman, K.F. Petersen, G.I. Shulman, S. Caprio, R.T. Constable; "Comparative MR Study of Hepatic Fat Quantification Using SingleVoxel Proton Spectroscopy, Two-Point Dixon and Three-Point IDEAL." Magnetic Resonance in Medicine 59:521-527 (2000).

Copyright 1996-2010 J.P. Hornak. All Rights Reserved.

http://science.howstuffworks.com/mri.htm http://www.healthcare.philips.com/mx_es/products/mri/education/online/ http://www.apple.com/uk/itunes/affiliates/download/?id=673865417

You might also like