You are on page 1of 7

Question 1 of 25.

The IQI is normally placed _____________.




on the film side

on the source side

film side with a letter F

at the discretion of the radiographer

Mark for follow up


Question 2 of 25.
Where must the required RT location markers be placed?


On the film holder/cassette.

On the part.

They can be scribed on the film after developing.

Location markers are optional unless required by the referencing code.

Mark for follow up


Question 3 of 25.
After the penetrant dwell time, the maximum emulsification time shall be:


5 min

10 min

15 min

None of the above

Mark for follow up


Question 4 of 25.
For a double wall exposure (DWE) / single wall viewing (SWV) RT Technique, a minimum of
______________exposures is required for complete coverage of circumferential welds.


1

2

3

4

Mark for follow up


Question 5 of 25.
Typical four step and five step UT pulse-echo US Customary calibration blocks for thickness-
measurement equipment have a thickness tolerance of _____________.


0.001mm

0.02mm

0.05 in

0.001 in

Mark for follow up


Question 6 of 25.
__________________can be detected by the Radiographic examination method.


Surface discontinuities

Surface and near surface discontinuities

Subsurface discontinuities

Surface and subsurface discontinuities

Mark for follow up


Question 7 of 25.
Which of the following is not included in ASME V?


Acoustic emission testing

Spark Testing (Positive Material Identification)

Ultrasonic examination

Visual examination

Mark for follow up


Question 8 of 25.
When, during magnetic particle examination, non-magnetic coatings are applied to enhance contrast, it
must be demonstrated that indications ______________________.


can be detected in 20 degrees F weather

cannot be detected through the coating

can be detected through the coating

None of the above

Mark for follow up


Question 9 of 25.
One of the five magnetization techniques used in MT is _________.


Hall-effect Tangential-field

circular

round

shearwave

Mark for follow up


Question 10 of 25.
A full penetration butt weld in a 1/4 inch thick plate with 1/8 inch thick reinforcement is to be radiographed
with the IQI on the film side. The radiographer does not have any hole-type IQIs with a designation of 15.
What other designated hole IQIs can be used instead?


Both 20 and 10

10

20

17

Mark for follow up


Question 11 of 25.
A single film technique was used to make a radiograph using a Cobalt-60 source. The minimum permitted
density in the area of interest is: ____________.


1.3

1.8

4.0

2.0

Mark for follow up


Question 12 of 25.
What is the difference between an inspection and an examination per Section V of the ASME Code?


Inspection is performed by the authorized inspector (AI), whereas examination is performed by the
manufacturers personnel.

Examination is performed on materials whereas inspection is performed on equipment.

Examination is performed by the authorized inspector (AI) whereas inspection is performed by the
manufacturers personnel.

There is no difference between the two.

Mark for follow up


Question 13 of 25.
A written procedure is required by ASME Section V for __________________.


MT and UT only

RT, UT, MT and PT

UT and MT only

RT and MT only

Mark for follow up


Question 14 of 25.
When should PT developer be applied?


As soon as possible after penetrant removal. Not to exceed time in the written procedure.

7 minutes after cleaning

No longer than 4 hours after cleaning

As the job schedule permits

Mark for follow up


Question 15 of 25.
Name one typical discontinuity readily detectable by the liquid penetrant method.


Heat Affected Zone (HAZ) surface cracks on a NPS 2 girth weld

Slag inclusions on a NPS 8 longitudinal weld

Incomplete fusion (I.F.) at the root of an NPS 2 girth weld

Incomplete Penetration (I.P.) on an Nominal Pipe Size (NPS) 2 girth weld

Mark for follow up


Question 16 of 25.
A inch thick material is to be magnetic particle tested with a yoke. The following types of yoke are
acceptable.


Shear wave yokes.

Both alternating current and direct current electromagnetic yokes.

Direct Current electromagnetic yokes.

Alternating current magnetic yokes.

Mark for follow up


Question 17 of 25.
For visible magnetic particles, the minimum light intensity required during examination and evaluation is
________.


1000 Lx

10000 Lx

1000 microns W/cm2

100 Lx

Mark for follow up


Question 18 of 25.
Geometric unsharpness is determined by:


Ug = f d / d

Ug = f t / d

Ug = P D / d

Ug = F d / D

Mark for follow up


Question 19 of 25.
Which of the following is not considered a type of film blemish?


Light letter B on a darker background.

Fogging.

Scratches and finger marks.

Streaks and water marks.

Mark for follow up


Question 20 of 25.
A 4T hole on an ASME SE-1025 number 20 IQI has a diameter of ____________ inches.


0.080

0.070

0.043

0.80

Mark for follow up


Question 21 of 25.
__________________can be detected by the Magnetic particle testing method.


Surface and near surface discontinuities

Surface and subsurface discontinuities

Subsurface discontinuities

Surface discontinuities

Mark for follow up


Question 22 of 25.
Certifications of contaminant content for all liquid penetrant materials used on all nickel base alloys,
austenitic stainless steel and titanium shall include which of the following?


Penetrant Manufacturer's name

Batch Numbers and test results

Technician's name

Penetrant Manufacturer's name, Batch Numbers, and test results

Mark for follow up


Question 23 of 25.
Which of the following discontinuities is typically detected by the magnetic particle method?


Interpass lack of fusion

Slag inclusions

Toe cracks

Lack of penetration

Mark for follow up


Question 24 of 25.
Which of the following methods may be used to remove weld surface irregularities that may mask
indications of unacceptable discontinuities when using RT?


Removal by grinding

Removal by machining

Removal by other methods

All of the above

Mark for follow up


Question 25 of 25.
A pipe weld is to be radiographed using a double wall exposure (DWE) technique with double wall
viewing (DWV). The IQI selection is based on___________.


the sum of the wall thicknesses

the single wall thickness plus any backing ring thickness

the single wall thickness and weld reinforcement

None of the above

Mark for follow up