5a1)

d = 15cm
cost = 12
#die = 84
defects = 0.02/cm2
die Area = 177/84 = 2.11
Y = 1 / (1+(0.02*(2.11/2)))^2 = .959 = 96%
Cost per die = 12 / (84 * .96) = 0.137
5a2)
#die = 84 + 84*.1 = 92
defects = .02 + .02*.15 = .023
die Area = 177/92 = 1.92
Y = 1 / (1+(0.023*(1.92/2)))^2 = 0.957 = 96%
5b1)
d = 20cm
cost = 15
#die = 100
defects = 0.031/cm2
die Area = 314/100 = 3.14
Y = 1 / (1+(0.031*(3.14/2)))^2 = 0.91
Cost per die = (15 / 100 * .91) = 0.137
5b2)
#die = 100 + 100*.1 = 110
defects = .031 + .031*.15 = .0341
die Area = 314/110 = 2.85
Y = 1 / (1+(0.0341*(2.85/2)))^2 = 0.0909 = 0.91

4a)
CL = 30W / (.9V * 3.4 Ghz) = 9.80
CL = 40W / (.9V * 3.4 Ghz) = 13.07
Avg = (9.80+13.07)/2 = 11.43
Total power dissipated = 30 + 40 = 70
% static = 30 / 70 = .428 = 42%
LC = 30W/.9V = 33.3A
SP I = 70W 70W *.1 = 63W
LC = 27W/V = 33.3A
V = .81
Voltage should be reduced by .9-.81 = .09V
4b)
CL = 10W / (.1.25V * 3.6 Ghz) = 2.22
CL = 90W / (1.25V * 3.6 Ghz) = 20
Avg = (2.22+20)/2 = 11.11
Total power dissipated = 10 + 90 = 100
% static = 10 / 100 = .1= 10%
LC = 10W/1.25V = 8A
SP I = 100W 100W *.1 = 90W
LC = 9W/V = 8A
V = 1.125
Voltage should be reduced by 1.25-1.125 = .125V