Design of Slab

Here the aspect ratio Ly/Lx is greater than 2 hence the slab is designed as a one way slab.
TwoLongEdgesDiscontinuous:
Basic dimensions of slab = Lx Ly
15 8
Basic Ly/Lx ratio = 0.533 >2
Hence designed as an one way slab
Clear cover to reinforcement d' = 25 mm
Provided overall depth D = 150.00 mm
Effective depth d = 120.00 mm
Diameter of bar f = 10 mm
Select Grade of Concrete fck = 20 N/mm
Select Grade of Steel fy = 415 N/mm
Load calculation :
Dead load of the slab DL = 3.750 kN/m
Floor finish(Roof finish) FF = 1.9 kN/m
Live load LL = 1.5 kN/m
Total load TL = 7.150 kN/m
Moment and Area of Steel calculations:
Mu Mu/bd Pt Ast reqd Min Ast Dia of barSpacing Ast pro
kN.m N/mm
2
% mm mm mm mm mm
301.64 0.00 ###### ###### 144 10 200 392.70 ######
-0.08
0.05
0.03
Check for Deflection
The effective depth provided = 120.000 mm
From figure 3 of I.S 456:1978 modification factor is
Modification factor = 1.36
Required depth under deflection consideration = 45.87 mm
HENCE SAFE
Design of Slab
Here the aspect ratio Ly/Lx is less than 2 hence the slab is designed as a two way slab.
TwoAdjacentEdgesDisContinuous:
Basic dimensions of slab = Lx Ly
4 6
Basic Ly/Lx ratio = 1.500 <2
Hence designed as two way slab
Clear cover to reinforcement d' = 15 mm
Provided overall depth D = 150.00 mm
Effective depth d = 130.00 mm
Diameter of bar f = 10 mm
Select Grade of Concrete fck = 20 N/mm
Select Grade of Steel fy = 415 N/mm
Load calculation :
Dead load of the slab DL = 3.750 kN/m
Floor finish(Roof finish) FF = 1.9 kN/m
Live load LL = 1.5 kN/m
Total load TL = 7.150 kN/m
Moment and Area of Steel calculations:
Span Mu Mu/bd Pt Ast reqd Min Ast Dia of bar Spacing Ast pro
kN.m N/mm
2
% mm mm mm mm mm
shorter a
x neg
0.078 13.39 0.79 0.23% 299.50 156 10 200 392.70 safe
a
x pos
0.059 10.04 0.59 0.17% 221.73 156 10 200 392.70 safe
longer a
y neg
0.045 7.78 0.46 0.13% 170.37 156 10 200 392.70 safe
a
y pos
0.034 5.83 0.35 0.10% 126.87 156 10 200 392.70 safe
Check for Deflection
The effective depth provided = 130.000 mm
From figure 3 of I.S 456:1978 modification factor is
Modification factor = 1.55
Required depth under deflection consideration = 92.41 mm
HENCE SAFE
Moment
Coefficient
F:\USER\RAM\3990\241431229.xls.ms_office RR/ST 8/16/2014