Professional Documents
Culture Documents
VMStar Catalog
VMStar Catalog
Rev 05.2011
Introduction 3
Materials Properties
Premium Products
13
Premium Services
19
Premium Connections
23
33
37
61
81
91
All tabulated values for minimum performance properties do not include design
safety factors.
Material properties change with increasing temperatures. Tabulated values are based
on room temperature.
Minimum internal pressure is the lowest of internal yield pressure of the pipe, internal yield
pressure of the coupling and internal pressure leak resistance for round thread casing or for
buttress thread casing.
V & M Tubes assumes no responsibility for the results obtained through the use of this
material. No expressed or implied warranty is intended and V & M TUBES EXPRESSLY
DISCLAIMS ALL EXPRESSED AND IMPLIED WARRANTIES, INCLUDING BUT
NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE, TITLE OR NON-INFRINGEMENT. In no event is
V & M Tubes responsible for any actual, consequential, incidental, special, punitive, or
indirect damages related to this catalog or information herein, (including, without limitation,
loss of profit, lost production, lost revenue, lost product, or lost business or business
interruptions, whether or not such damages are foreseeable or V & M Tubes was advised
of the possibility of such damages).
Rev 05.2011
This catalog is for informational purposes only. All data presented in this catalog must
be supplemented by the professional judgment of qualified personnel. While every
effort has been made to ensure the accuracy of all data and that the information
contained herein is correct, this material is presented as a reference guide only.
Information in this catalog may be altered at any time by V & M Tubes without notice
to users. Anyone using or relying on general information presented in this catalog
does so at their own risk and assumes any and all liability.
INTRODUCTION
V & M TUBES
North America
Rev 05.2011
Rev 05.2011
Brief History
p
pp
pt
pp
p
p
p
VAM Norge
p
p
n
lt
VAM Canada
V & M STAR
t
n
pp
pp pp
TCA npppppppp
p
p
t pppp
l n
VAM USA
V & M USA Corp
V & M Tube Alloy
V & M STAR
lt
p
pn
pp
p p
nl V
p pp
p
p ppp p pppH
p
p
V & M Rus
& M Deutschland
Hnl
p
p VAM
tp
ppp
p
pp
p
p
pp
V & M Kazakhstan
Caspian
V & M Beijing
p
p
p
pl
p
p
t
ln
p
p
p
p
VAM
p
pt
pl p
p
tl
pp
VAM Changzhou np
Dubai
p
p
p
p
VAM Mexico
p
p
p p
pp
tl
p p
p VMOG
p
p
p
ppp
ptl
np
pp
Nigeria
p
p
p
PT Citra Tubindo
Rev 05.2011
p
p
p
p
n p
H pp
plt
pp
t VAM Angola
p
p
p
V & M do Brasil
l Sales Offices
Steelmaking Plants
n Manufacturing Plants
p Accessories and Repair
p
p
Our comprehensive Research & Development policy aims to provide innovative solutions
to our customers. The objective is to create,
improve and promote products, services,
materials and processes for the future.
Attuned to actual market needs and working
in close cooperation with marketing and plant
teams, our R&D staff have access to substantial
resources for putting this policy into effect:
Over 500 employees dedicated to R&D
An R&D budget that averages 2% of sales
Five research centers in four countries
dedicated to OCTG product development:
Germany
VALLOUREC Research Dsseldorf - Rolling
Competence Center
VALLOUREC Research Riesa - Rolling
Laboratory
France
VALLOUREC Research Aulnoye
Brazil
VALLOUREC Research Belo Horizonte
USA
VAM Research Houston
Rev 05.2011
An Integrated &
Competitive Process
These centers, equipped with high-performance investigative and modeling tools, provide
expertise to VALLOURECs core competencies,
including metallurgy, heat transfer technology,
non-destructive testing, corrosion, surface
treatment, premium connection technology and
product and process simulations.
Customized Solutions to Service
Long Term Partnerships
Quality
Rev 05.2011
Environmental Preservation
Rev 05.2011
Environment
Material Properties
API 5CT Grades
V & M supplies the full range of API 5CT standard grades and grades with enhanced performances. All Product Specification Levels (PSL) and
Special Requirements (SR) from API 5CT can be delivered, with PSL 2 standardized on all quenched and tempered grades.
Yield Strength (ksi)
Grade
J55
80
75
55
80
95
80
110
100
80
95
95
23.0
80
95
95
23.0
L80 HCE a
87.5
95
95
23.0
L80 IRP
80
95
95
23.0
L80 1Cr
80
95
95
23.0
C90
90
105
100
25.4
90
105
100
25.4
C95/R95
95
110
105
T95
95
110
105
25.4
T95 HC a
95
110
105
25.4
100
110
105
25.4
100
110
105
25.4
110
120
115
30
110
125
125
29
110
140
125
125
140
135
125
140
135
125
150
135
C90 HC
T95 E
T95 HCE
C110
Rev 05.2011
55
HRC
K55
L80 HC
P110 MS
P110
P110 EC
a, b
P110 HCE
a, b
Q125
Q125 HC
Q125 HCE a
b
Maximum
N80
L80
Minimum
125
150
135
135
150
140
API grades with enhanced performance are supplied with API couplings produced from standard API grades, unless a premium connection is specified.
Properties are only valid for products manufactured in the U.S. mills.
Material Properties
V&M Proprietary Grades
V & M proprietary grades offer solutions for grades or requirements not covered by API 5CT. They also offer greater performances (e.g. High Collapse
grades) and higher reliability (e.g. Sour Service grades) thanks to stringent internal requirements in quality and process control, mechanical properties and
material testing.
HPHT grades are used when high strength is required with limited resistance to sour service conditions within the guidelines of NACE MR0175.
Grade
VM125CY
HRC
135
35
175F
125
140
VM130CY
130
140
135
35
175F
VM125HY
140
150
145
36
225F
Deep Well
Deep Well grades are used where high yield strength is required while maintaining ductility and fracture toughness.
Minimum
Maximum
VM140
140
165
150
38 ft-lbs
VM150
150
175
160
30 ft-lbs
Grade
High Collapse
High Collapse grades for casing are used in high pressure wells. They offer an average of 25% and up to 40% extra performance over API collapse
ratings. As mechanical properties and pipe dimensions are major factors in collapse resistance, the following parameters have been optimized to guarantee
high collapse pressure: D/t ratio, yield strength, ovality, wall thickness and residual stresses.
Grade
VM80HC
Maximum
80
110
100
VM95HC
95
125
110
VM110HC
110
140
125
VM125HC
125
150
135
VM140HC
140
165
150
10
Collapse Resistance
Rev 05.2011
Material Properties
Sour Service
Sour Service grades for tubing and casing are used in wells where H2S is present. The threshold stresses have been determined according to Method A
of NACE TM0177 standard. Upon request, Sour Service grades are also tested according to Method D (DCB test).
Grade
Threshold stress
Minimum
HRC
VM80S
80
95
95
22
85% SMYS
VM80SS
80
95
95
22
90% SMYS
VM90S
90
105
100
24
85% SMYS
VM90SS
90
105
100
24
90% SMYS
VM95S
95
110
105
25
85% SMYS
VM95SS
95
110
105
25
90% SMYS
VM100SS
100
115
110
28
85% SMYS
VM110SS
110
120
120
30
85% SMYS
VM125SS
125
135
130
34
High Collapse and Sour Service grades for casing are used in high pressure wells where H2S is present.
Rev 05.2011
Grade
HRC
Threshold stress
Minimum
VM80HCS
80
95
95
22
85% SMYS
VM80HCSS
80
95
95
22
90% SMYS
VM90HCS
90
105
100
24
85% SMYS
VM90HCSS
90
105
100
24
90% SMYS
VM95HCS
95
110
105
25
85% SMYS
VM95HCSS
95
110
105
25
90% SMYS
VM110HCSS
110
125
120
30
85% SMYS
11
Collapse Resistance
Minimum guaranteed
collapse pressures are
available upon request
Material Properties
Sweet Corrosion
Martensitic grades (13Cr and Super 13Cr) are used in wells with CO2, chlorides and/or some H2S up to 365F.
Type
13% Chrome
Grade
HRC
VM80 13CR
80
95
95
23
VM85 13CR
85
100
100
24
VM90 13CR
90
105
100
26
VM95 13CR
95
110
105
28
VM95 13CRSS
95
110
105
30
VM110 13CRSS
110
125
120
34
HRC
140
115
36
Highly Corrosive
Ferritic-austenitic grades are used in wells with CO2, chlorides and/or some H2S up to 480F.
Type
Grade
VM22 110
Duplex
Super
Duplex
VM22 125
125
150
130
37
VM22 140
140
160
145
38
VM25 125
125
150
130
37
VM25 140
140
160
145
38
VM25S 125
125
150
130
37
VM25S 140
140
160
145
38
HRC
Austenitic grades are used in wells where high concentration of H2S, CO2 and chlorides are present.
Yield Strength (ksi)
Minimum
Maximum
Type
Grade
VM28 110
110
140
115
35
Super Austenitic
VM28 125
125
150
130
37
Nickel
Base Alloys
VM28 135
135
155
140
38
VM825 110
110
135
115
35
VM825 120
120
145
125
37
VM G3 110
110
130
115
35
VM G3 125
125
145
130
37
VM G50 110
110
130
115
35
VM G50 125
125
145
130
37
12
Rev 05.2011
Premium Products
Premium Tubular Solutions
Rev 05.2011
13
14
Rev 05.2011
Rev 05.2011
15
Thermocase Vacuum
Insulated Tubing
Cold Startups
Well Testing
Steam Flooding
Monobore
Recompletion
Zonal Isolation
Sidetrack
16
Casing Remediation
Case Off
Liner Hanger
Rev 05.2011
17
18
Rev 05.2011
Premium Services
Services for a Demanding
Industry
Rev 05.2011
19
Accessories Management
20
Assembly Makeup
p
pp
pt
pp
p
p
ltppp
p
pp
lV
p pp pp
p pp p p ppp
p
p
VAM Norge
p
p
lt
VAM Canada
V&M
V & M STAR
VAM USA
V & M USA Corp
V & M Tube-Alloy
V & M STAR
V & M Rus
& M Deutschland
p
pp
V & M Kazakhstan
tpVAM Caspian
ppp
p
pp
p
p
V & M Beijing
p
p
p
pl
p
p
t
l
p
p
p
p
VAM
p
pt
pl p
p
tl
pp
VAM Changzhou
Dubai
p
p
p
p
p p
pp
tl
p p
VAM Mexico
Rev 05.2011
p VMOG
p
p
p
ppp
ptl
p
pp
Nigeria
p
p
p
PT Citra Tubindo
t VAM Angola
p
p
p
p
pp
p
p
p t
pp
V & M do Brasil
l Sales Offices
p
International
21
p
p
22
22
Rev 05.2011
Premium CONNECTIONS
World Leader for Premium
Connections
Rev 05.2011
23
Sample Preparation
Bending
Elevated Temperature
Fatigue Life
VAM USA:
A Comprehensive
Range of Equipment
24
Sour Service
Rev 05.2011
25
CONNECTION
VAM TOP
CONNECTION
VAM 21
TYPE
Threaded & Coupled
TYPE
Threaded & Coupled
SIZE RANGE
2 3/8 to 16
SIZE RANGE
9 5/8 to 14
APPLICATIONS
Production casing and tubing
Tie-backs
Intermediate casing
Rotating liner
Rotation during cementation
Wells with extreme compression
loads
APPLICATIONS
Production casing
Intermediate casing
BENEFITS
Excellent gas-tight sealing under
combined loads
Reversed angle torque shoulder
provides excellent resistance to
bending, compression and torque
Seal protected from rough
handling
Reduced drilling wear
susceptibility
Extreme compression and torque
resistance
BENEFITS
Excellent gas-tight sealing under
combined loads
Reversed angle torque shoulder
provides excellent resistance to
bending, compression and torque
Thread geometry optimized by
size to minimize the risk of galling
Connection options allow for
greater torque and compression
Internal Pressure
100%
RATINGS
Internal Pressure
100%
External Pressure
100%
External Pressure
100%
26
Rev 05.2011
RATINGS
Rev 05.2011
CONNECTION
VAM HP
CONNECTION
VAM HW-ST
TYPE
Threaded & Coupled
TYPE
Threaded & Coupled
SIZE RANGE
7 5/8 to 10 3/4
SIZE RANGE
5 to 14
APPLICATIONS
Heavy wall casing for HPHT
Production liners
Tie-backs
APPLICATIONS
Heavy wall casing for HPHT
Production liners
Tie-backs
BENEFITS
Dual gas-tight metal-to-metal
seals
Reversed angle torque shoulder
provides excellent resistance to
bending, compression and torque
BENEFITS
Excellent gas-tight sealing under
combined loads
Reversed angle torque shoulder
provides excellent resistance to
bending, compression and torque
RATINGS
Internal Pressure
100%
RATINGS
Internal Pressure
100%
External Pressure
100%
External Pressure
70%
27
CONNECTION
VAM SLIJ-II
CONNECTION
VAM SG
TYPE
Semi Flush
TYPE
Semi Flush
SIZE RANGE
4 1/2 to 16
SIZE RANGE
4 1/2 to 5 1/2
APPLICATIONS
Production casing
Intermediate casing
Drilling liners
Drilling with casing
Tie-backs
APPLICATIONS
Production casing
Highly deviated wells
Long laterals
BENEFITS
Specifically tested for Shale Well
design applications
Gas-tight metal seal protected by
mid-shoulder from handling
damage
Deep stabbing two-step thread
BENEFITS
Optimized clearance with high
tensile efficiency
Dual gas-tight metal-to-metal
seals
Expanded box (2-3% over
nominal pipe OD)
Deep stabbing two-step thread
RATINGS
Internal Pressure
100%
External Pressure
50%
External Pressure
100%
28
Rev 05.2011
RATINGS
Internal Pressure
100%
CONNECTION
ST-L
CONNECTION
HD-L
TYPE
Flush
TYPE
Flush
SIZE RANGE
2 3/8 to 14
SIZE RANGE
2 3/8 to 20
APPLICATIONS
Drilling liners
Moderate depth casing
Tight hole tubing strings
Tie-backs
APPLICATIONS
Drilling liners
Moderate depth casing
Tight hole tubing strings
Tie-backs
Deviated wells with severe
compression and bending
RATINGS
Internal pressure
Dual gas-tight metal-to-metal
seals
Twin-lead thread for fast makeup
Maximum clearance - OD flush
with the pipe
RATINGS
Internal pressure
Gas-tight metal-to-metal internal
seal
External metal seal up to 13 5/8
Maximum clearance - OD flush
with the pipe
High compression rating
Rev 05.2011
RATINGS
Internal Pressure
100%
External Pressure
100%
RATINGS
Internal Pressure
100%
External Pressure
100%
29
CONNECTION
VAM HTF
TYPE
Threaded & Coupled
TYPE
Flush
SIZE RANGE
3 1/2 to 13 3/8
SIZE RANGE
4 1/2 to 9 7/8
APPLICATIONS
Drilling with casing
Production casing
Tubing
APPLICATIONS
Drilling liners
Drilling with casing
Production liners
Rotation during cementation
BENEFITS
Pin-to-pin torque shoulder
Excellent torque, compression
and bending resistance
Improved thread sealing
compared to buttress
Fatigue enhancements for drilling
through a dogleg
BENEFITS
Dual gas-tight metal-to-metal
seals
Maximum clearance - OD flush
with the pipe
Dovetail thread form for extremely
high torque capacity
RATINGS
Internal Pressure
100%
RATINGS
Internal Pressure
100%
External Pressure
100%
External Pressure
100%
30
Rev 05.2011
CONNECTION
DWC/C
CONNECTION
VAM BOLT
CONNECTION
BIG OMEGA
TYPE
Flush
TYPE
Threaded & Coupled
SIZE RANGE
16 and 18
SIZE RANGE
14 to 26
APPLICATIONS
Surface casing with tight
clearance requirements
Ideal for running inside Big Bore
wellhead systems
APPLICATIONS
Surface casing
BENEFITS
Coarse rugged three-pitch thread
form
Excellent stabbing and anti-cross
threading
Improved thread sealing
compared to buttress
BENEFITS
Dual gas-tight metal-to-metal
seals
Dovetail thread form for excellent
jump-out resistance
Twin-lead thread for quick
makeup
Flush OD
External torque shoulder
RATINGS
Internal Pressure
100%
Tension (% of Pipe Body)
100%
Rev 05.2011
RATINGS
Internal Pressure
100%
External Pressure
100%
Tension (% of Pipe Body)
60%
Compression (% of Pipe Body)
60%
31
32
Rev 05.2011
PErformance Data
Tubing Dimensions & Minimum Performance Properties
Weight
OD
NU
T&C
(in)
EU
T&C
Pipe Body
Drift
Wall
Area
PE
(lb/ft)
(in)
(in2)
Grade
API
ALT.
(in)
(in)
J55
4.60
5.80
4.70
5.95
4.44
5.76
0.190
0.254
1.304
1.692
1.901
1.773
N/A
N/A
Rev 05.2011
2 3/8
6.60
7.35
2 7/8
EU
NU
ALT
IP
PBYS
6.40
7.45
6.50
6.56
7.32
6.17
0.295
0.336
0.217
1.928
2.152
1.812
1.691
1.609
2.347
N/A
N/A
N/A
Collapse
IP
(Barlow)
IP
(Lam capped)
PBYS
JT
Strength
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
8,100
7,700
7,600
8,250
7,880
72
7,700
49
7,700
72
K55
8,100
7,700
7,600
8,250
9,980
72
7,700
49
7,700
72
N80
11,780
11,200
11,060
12,000
10,630
104
11,200
72
11,200
104
L80
11,780
11,200
11,060
12,000
12,250
104
11,200
72
11,200
104
C90
13,250
12,600
12,440
13,500
12,960
117
12,600
81
12,600
117
C95/R95
13,980
13,300
13,140
14,250
13,610
124
13,300
85
13,300
124
T95
13,980
13,300
13,140
14,250
13,640
124
13,300
85
13,300
124
P110
16,130
15,400
15,210
16,500
16,370
143
15,400
99
15,400
143
N80
15,280
14,970
14,640
15,640
14,470
135
14,970
103
14,850
135
L80
15,280
14,970
14,640
15,640
16,740
135
14,970
103
14,850
135
C90
17,190
16,840
16,470
17,590
17,710
152
16,840
116
16,710
152
C95/R95
18,150
17,780
17,390
18,570
18,590
161
17,780
122
17,630
161
T95
18,150
17,780
17,390
18,570
18,640
161
17,780
122
17,630
161
P110
21,010
20,590
20,130
21,500
22,360
186
20,590
142
20,420
186
N80
17,410
17,390
16,870
17,860
17,010
154
L80
17,410
17,390
16,870
17,860
19,720
154
C90
19,580
19,560
18,980
20,090
20,860
173
C95/R95
20,670
20,650
20,040
21,210
21,900
183
T95
20,670
20,650
20,040
21,210
21,960
183
P110
23,930
23,910
23,200
24,560
26,340
212
N80
19,430
19,810
19,050
20,000
19,600
172
14,850
172
L80
19,430
19,810
19,050
20,000
22,790
172
14,850
172
C90
21,860
22,280
21,430
22,500
24,100
194
16,710
194
C95/R95
23,080
23,520
22,620
23,750
25,310
204
17,630
204
T95
23,080
23,520
22,620
23,750
25,370
204
17,630
204
P110
26,720
27,230
26,190
27,500
30,430
237
20,420
237
J55
7,680
7,260
7,180
7,820
7,410
100
7,260
73
7,260
100
K55
7,680
7,260
7,180
7,820
9,390
100
7,260
73
7,260
100
N80
11,170
10,570
10,450
11,370
10,000
145
10,570
106
10,570
145
L80
11,170
10,570
10,450
11,370
11,520
145
10,570
106
10,570
145
C90
12,380
11,890
11,760
12,790
12,190
163
11,890
119
11,890
163
C95/R95
12,940
12,550
12,410
13,500
12,790
172
12,550
125
12,550
172
T95
12,940
12,550
12,410
13,500
12,830
172
12,550
125
12,550
172
P110
14,550
14,530
14,370
15,630
15,380
199
14,530
145
14,530
199
external upset
non-upset
alternate drift
internal pressure
pipe body yield strength
IP
(Lam open)
Connection
IP
(Lam ductile
rupture)
33
PErformance Data
Tubing Dimensions & Minimum Performance Properties
OD
NU
T&C
(in)
EU
T&C
Wall
7.90
Area
PE
(lb/ft)
7.80
Pipe Body
Drift
(in)
7.67
0.276
(in2)
2.254
Grade
API
ALT.
(in)
(in)
2.229
N/A
2 7/8
8.60
9.20
8.70
9.30
8.45
8.81
0.308
0.254
2.484
2.590
2.165
2.867
N/A
N/A
3 1/2
10.20
12.70
EU
NU
ALT
IP
PBYS
12.95
9.92
12.53
0.289
0.375
2.915
3.682
2.797
2.625
N/A
N/A
Collapse
IP
(Barlow)
IP
(Lam capped)
PBYS
JT
Strength
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
N80
13,890
13,440
13,200
14,190
12,900
180
13,440
141
13,440
180
L80
13,890
13,440
13,200
14,190
14,890
180
13,440
141
13,440
180
C90
15,620
15,120
14,850
15,960
15,760
203
15,120
158
15,120
203
C95/R95
16,490
15,960
15,680
16,840
16,540
214
15,960
167
15,960
214
T95
16,490
15,960
15,680
16,840
16,580
214
15,960
167
15,960
214
P110
19,090
18,480
18,150
19,500
19,890
248
18,480
194
18,480
248
N80
15,300
15,000
14,670
15,660
14,500
199
15,000
159
14,940
199
L80
15,300
15,000
14,670
15,660
16,770
199
15,000
159
14,940
199
C90
17,220
16,870
16,500
17,620
17,740
224
16,870
179
16,810
224
C95/R95
18,170
17,810
17,420
18,600
18,630
236
17,810
189
17,750
236
T95
18,170
17,810
17,420
18,600
18,680
236
17,810
189
17,750
236
P110
21,040
20,620
20,170
21,540
22,400
273
20,620
219
20,550
273
142
J55
7,400
6,990
6,910
7,540
7,110
142
6,990
109
6,990
K55
7,400
6,990
6,910
7,540
9,010
142
6,990
109
6,990
142
N80
10,540
10,160
10,060
10,960
9,600
207
10,160
159
10,160
207
L80
10,540
10,160
10,060
10,960
11,050
207
10,160
159
10,160
207
C90
11,570
11,430
11,310
12,330
11,690
233
11,430
179
11,430
233
C95/R95
12,080
12,070
11,940
13,020
12,270
246
12,070
189
12,070
246
T95
12,080
12,070
11,940
13,020
12,300
246
12,070
189
12,070
246
P110
13,530
13,970
13,830
15,070
14,760
285
13,970
219
13,970
285
N80
12,120
11,560
11,410
12,360
11,000
233
11,560
185
L80
12,120
11,560
11,410
12,360
12,670
233
11,560
185
C90
13,640
13,010
12,830
13,900
13,410
262
13,010
208
C95/R95
14,390
13,730
13,550
14,670
14,080
277
13,730
220
T95
14,390
13,730
13,550
14,670
14,110
277
13,730
220
P110
16,670
15,900
15,690
16,990
16,930
321
15,900
255
N80
15,310
15,000
14,670
15,660
14,500
295
15,000
246
15,000
295
L80
15,310
15,000
14,670
15,660
16,770
295
15,000
246
15,000
295
C90
17,220
16,880
16,500
17,620
17,740
331
16,880
277
16,880
331
C95/R95
18,180
17,810
17,420
18,600
18,630
350
17,810
293
17,810
350
T95
18,180
17,810
17,420
18,600
18,680
350
17,810
293
17,810
350
P110
21,050
20,630
20,170
21,540
22,400
405
20,630
339
20,630
405
external upset
non-upset
alternate drift
internal pressure
pipe body yield strength
IP
(Lam open)
Connection
IP
(Lam ductile
rupture)
34
Rev 05.2011
Weight
Performance Data
Tubing Dimensions & Minimum Performance Properties
Weight
OD
NU
T&C
(in)
EU
T&C
Pipe Body
Drift
Wall
Area
PE
(lb/ft)
(in)
(in2)
Grade
API
ALT.
(in)
(in)
J55
9.50
9.12
0.226
2.680
3.423
N/A
4
11.00
10.47
0.262
3.077
3.351
N/A
Rev 05.2011
10.70
13.20
12.60
12.75
12.95
12.25
0.330
0.271
3.805
3.600
3.215
3.833
N/A
N/A
4 1/2
15.20
EU
NU
ALT
IP
PBYS
15.00
0.337
4.407
3.701
N/A
Collapse
IP
(Barlow)
IP
(Lam capped)
PBYS
IP
JT
Strength
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
5,110
5,440
5,400
5,960
5,480
147
5,440
99
K55
5,110
5,440
5,400
5,960
6,940
147
5,440
99
N80
6,590
7,910
7,860
8,660
7,400
214
7,910
144
L80
6,590
7,910
7,860
8,660
8,490
214
7,910
144
C90
7,080
8,900
8,840
9,740
8,990
241
8,900
162
C95/R95
7,310
9,390
9,340
10,290
9,440
255
9,390
171
T95
7,310
9,390
9,340
10,290
9,460
255
9,390
171
P110
7,910
10,880
10,810
11,910
11,350
295
10,880
198
J55
6,590
6,300
6,250
6,850
6,390
169
6,300
169
N80
8,800
9,170
9,090
9,960
8,620
246
9,170
246
L80
8,800
9,170
9,090
9,960
9,920
246
9,170
246
C90
9,590
10,320
10,230
11,200
10,490
277
10,320
277
C95/R95
9,980
10,890
10,800
11,830
11,020
292
10,890
292
T95
9,980
10,890
10,800
11,830
11,040
292
10,890
292
P110
11,060
12,610
12,500
13,690
13,250
338
12,610
338
N80
12,110
11,550
11,400
12,350
10,990
304
L80
12,110
11,550
11,400
12,350
12,660
304
C90
13,620
12,990
12,820
13,890
13,390
342
C95/R95
14,380
13,720
13,530
14,660
14,060
361
T95
14,380
13,720
13,530
14,660
14,100
361
P110
16,650
15,880
15,670
16,980
16,910
419
J55
5,730
5,800
5,760
6,330
5,850
198
5,800
144
5,800
198
K55
5,730
5,800
5,760
6,330
7,410
198
5,800
144
5,800
198
N80
7,500
8,430
8,370
9,200
7,900
288
8,430
209
8,430
288
L80
7,500
8,430
8,370
9,200
9,080
288
8,430
209
8,430
288
C90
8,120
9,490
9,420
10,350
9,610
324
9,490
235
9,490
324
C95/R95
8,410
10,010
9,940
10,930
10,090
342
10,010
248
10,010
342
T95
8,410
10,010
9,940
10,930
10,110
342
10,010
248
10,010
342
396
P110
9,210
11,590
11,510
12,650
12,130
396
11,590
287
11,590
N80
11,080
10,480
10,370
11,290
9,920
353
L80
11,080
10,480
10,370
11,290
11,420
353
C90
12,220
11,800
11,670
12,700
12,080
397
C95/R95
12,760
12,450
12,310
13,400
12,690
419
T95
12,760
12,450
12,310
13,400
12,720
419
P110
14,340
14,420
14,260
15,520
15,260
485
external upset
non-upset
alternate drift
internal pressure
pipe body yield strength
IP
(Lam open)
Connection
IP
(Lam ductile
rupture)
35
36
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
4 1/2
9.50
4 1/2 10.50
9.41
10.24
11.36
(in)
0.205
0.224
0.250
(in2)
2.766
3.009
3.338
API
ALT.
(in)
(in)
3.965
3.927
3.875
Rev 05.2011
4 1/2 11.60
Area
PE
(lb/ft)
4 1/2 13.50
13.05
Pipe Body
Drift
0.290
3.836
3.795
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
N/A
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
3,310
4,380
4,370
4,850
4,400
152
4,380
101
K55
3,310
4,380
4,370
4,850
5,570
152
4,380
112
J55
4,010
4,790
4,770
5,280
4,820
166
4,790
132
4,790
203
K55
4,010
4,790
4,770
5,280
6,100
166
4,790
146
4,790
249
J55
4,960
5,350
5,320
5,860
5,400
184
5,350
154
5,350
162
1,610
5,350
225
K55
4,960
5,350
5,320
5,860
6,840
184
5,350
170
5,350
180
1,790
5,350
277
J55
N/A
8rd STC
N80
6,360
7,780
7,730
8,520
7,290
267
7,780
216
7,780
223
2,220
7,780
304
L80
6,360
7,780
7,730
8,520
8,370
267
7,780
212
7,780
212
2,110
7,780
291
L80 1Cr
6,360
7,780
7,730
8,520
8,370
267
7,780
212
7,780
212
2,110
7,780
291
291
L80 HC
7,720
7,780
7,730
8,520
8,370
267
7,780
212
7,780
212
2,110
7,780
L80 IRP
6,360
7,780
7,730
8,520
8,370
267
7,780
212
7,780
212
2,110
7,780
291
L80 HCE
7,720
8,510
8,460
9,320
8,370
292
8,510
212
8,510
212
2,110
8,510
291
C90
6,810
8,750
8,700
9,590
9,730
300
8,750
223
8,750
223
2,220
8,750
309
C95/R95
7,030
9,240
9,180
10,120
9,310
317
9,240
234
9,240
234
2,340
9,240
325
T95
7,030
9,240
9,180
10,120
10,280
317
9,240
234
9,240
234
2,340
9,240
325
T95 HC
8,550
9,240
9,180
10,120
10,280
317
9,240
234
9,240
234
2,340
9,240
325
T95 E
7,030
9,720
9,660
10,660
10,280
334
9,720
234
9,720
234
2,340
9,720
325
T95 HCE
8,550
9,720
9,660
10,660
10,280
334
9,720
234
9,720
234
2,340
9,720
325
P110
7,580
10,690
10,630
11,720
12,320
367
10,690
279
10,690
279
2,780
10,690
385
P110 MS
7,580
10,690
10,630
11,720
11,150
367
10,690
279
10,690
279
2,780
10,690
385
N/A
P110 EC
8,860
12,150
12,080
13,320
13,300
417
12,150
279
12,150
279
2,780
12,150
385
P110 HCE
9,590
12,150
12,080
13,320
13,300
417
12,150
279
12,150
279
2,780
12,150
385
Q125
8,000
12,150
12,080
13,320
13,300
417
12,150
301
12,150
301
3,000
12,150
420
Q125 HC
9,870
12,150
12,080
13,320
13,300
417
12,150
301
12,150
301
3,000
12,150
420
Q125 HCE
9,870
13,130
13,050
14,390
13,880
451
13,130
301
13,130
301
3,000
13,130
420
N80
8,540
9,020
8,950
9,810
8,500
307
9,020
270
2,700
9,020
349
L80
8,540
9,020
8,950
9,810
9,780
307
9,020
257
2,560
9,020
334
L80 1Cr
8,540
9,020
8,950
9,810
9,780
307
9,020
257
2,560
9,020
334
L80 HC
9,560
9,020
8,950
9,810
9,780
307
9,020
257
2,560
9,020
334
L80 IRP
8,540
9,020
8,950
9,810
9,780
307
9,020
257
2,560
9,020
334
9,560
9,870
9,790
10,730
9,780
336
9,870
257
2,560
9,790
334
C90
9,300
10,150
10,070
11,030
11,380
345
10,150
270
2,700
10,150
355
C95/R95
9,660
10,710
10,630
11,650
10,870
364
10,710
284
2,830
10,710
374
T95
9,660
10,710
10,630
11,650
12,020
364
10,710
284
2,830
10,710
374
T95 HC
10,850
10,710
10,630
11,650
12,020
364
10,710
284
2,830
10,710
374
T95 E
9,660
11,280
11,190
12,260
12,020
384
11,280
284
2,830
11,280
374
37
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
4 1/2 13.50
4 1/2 15.10
Area
PE
(lb/ft)
13.05
15.00
Pipe Body
Drift
(in)
0.290
0.337
(in2)
3.836
4.407
API
ALT.
(in)
(in)
3.795
3.701
16.54
0.375
4.860
3.625
N/A
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
10,850
11,280
11,190
12,260
12,020
384
11,280
284
2,830
11,280
374
P110
443
10,690
12,410
12,310
13,490
14,400
422
12,410
338
3,370
12,410
P110 MS 10,690
12,410
12,310
13,490
14,400
422
12,410
338
3,370
12,410
443
P110 EC
14,100
13,980
15,320
15,550
479
14,100
338
3,370
13,470
443
443
11,600
14,100
13,980
15,320
15,550
479
14,100
338
3,370
13,470
C110
10,690
12,410
12,310
13,490
13,250
422
12,410
311
3,100
12,410
413
Q125
11,600
14,100
13,980
15,320
15,550
479
14,100
365
3,640
14,100
482
Q125 HC
13,810
14,100
13,980
15,320
15,550
479
14,100
365
3,640
14,100
482
15,230
15,100
16,550
16,220
518
15,230
365
3,640
15,230
482
N80
11,080
10,480
10,370
11,290
9,950
353
10,480
325
3,240
9,790
401
L80
11,080
10,480
10,370
11,290
11,450
353
10,480
308
3,080
9,790
384
L80 1Cr
11,080
10,480
10,370
11,290
11,450
353
10,480
308
3,080
9,790
384
L80 HC
11,950
10,480
10,370
11,290
11,450
353
10,480
308
3,080
9,790
384
L80 IRP
11,080
10,480
10,370
11,290
11,450
353
10,480
308
3,080
9,790
384
L80 HCE
11,950
11,470
11,340
12,350
11,450
386
10,650
308
3,080
9,790
384
C90
12,220
11,800
11,670
12,700
13,340
397
11,800
325
3,240
11,020
408
C95/R95
12,760
12,450
12,310
13,400
12,740
419
12,450
341
3,400
11,630
429
T95
12,760
12,450
12,310
13,400
14,100
419
12,450
341
3,400
11,630
429
T95 HC
13,300
12,450
12,310
13,400
14,100
419
12,450
341
3,400
11,630
429
T95 E
12,760
13,110
12,960
14,110
14,100
441
12,650
341
3,400
11,630
429
T95 HCE
13,300
13,110
12,960
14,110
14,100
441
12,650
341
3,400
11,630
429
P110
14,340
14,420
14,260
15,520
16,880
485
14,420
406
4,050
13,470
509
P110 MS 14,340
14,420
14,260
15,520
16,880
485
14,420
406
4,050
13,470
509
P110 EC
4 1/2 16.60
8rd STC
T95 HCE
N/A
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
15,830
16,380
16,200
17,640
18,230
551
14,640
406
4,050
13,470
509
16,380
16,200
17,640
18,230
551
14,640
406
4,050
13,470
509
C110
14,340
14,420
14,260
15,520
15,530
485
14,420
373
3,730
13,470
475
Q125
15,830
16,380
16,200
17,640
18,230
551
16,380
438
4,380
15,300
554
Q125 HC
17,330
16,380
16,200
17,640
18,230
551
16,380
438
4,380
15,300
554
554
17,690
17,500
19,050
19,030
595
16,640
438
4,380
15,300
N80
12,220
11,670
11,510
12,460
11,130
389
L80
12,220
11,670
11,510
12,460
12,830
389
L80 1Cr
12,220
11,670
11,510
12,460
12,830
389
L80 HC
13,370
11,670
11,510
12,460
12,830
389
L80 IRP
12,220
11,670
11,510
12,460
12,830
389
L80 HCE
13,370
12,760
12,590
13,630
12,830
425
C90
13,750
13,130
12,950
14,020
14,960
437
38
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
C95/R95
4 1/2 16.60
16.54
0.375
4.860
3.625
21.38
0.430
0.500
5.498
6.283
3.515
3.375
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
13,850
13,670
14,800
14,270
462
T95
14,510
13,850
13,670
14,800
15,800
462
T95 HC
15,280
13,850
13,670
14,800
15,800
462
T95 E
14,510
14,580
14,390
15,580
15,800
486
T95 HCE
15,280
14,580
14,390
15,580
15,800
486
P110
16,810
16,040
15,830
17,130
18,930
535
N/A P110 MS
16,810
16,040
15,830
17,130
18,930
535
P110 EC
17,710
18,230
17,980
19,470
20,440
607
18,230
17,980
19,470
20,440
607
Rev 05.2011
4 1/2 21.50
18.71
8rd STC
14,510
C110
16,810
16,040
15,830
17,130
17,410
535
Q125
19,100
18,230
17,980
19,470
20,440
607
Q125 HC
20,510
18,230
17,980
19,470
20,440
607
4 1/2 18.90
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
N/A
19,690
19,420
21,030
21,330
656
N80
13,830
13,380
13,140
14,130
12,870
440
L80
13,830
13,380
13,140
14,130
14,860
440
L80 1Cr
13,830
13,380
13,140
14,130
14,860
440
L80 HC
15,170
13,380
13,140
14,130
14,860
440
L80 IRP
13,830
13,380
13,140
14,130
14,860
440
L80 HCE
15,170
14,630
14,370
15,450
14,860
481
C90
15,560
15,050
14,780
15,890
17,340
495
C95/R95
16,420
15,890
15,610
16,770
16,520
522
T95
16,420
15,890
15,610
16,770
18,320
522
T95 HC
17,560
15,890
15,610
16,770
18,320
522
T95 E
16,420
16,720
16,430
17,660
18,320
550
T95 HCE
17,560
16,720
16,430
17,660
18,320
550
P110
19,010
18,390
18,070
19,420
21,940
605
P110 MS
19,010
18,390
18,070
19,420
21,940
605
P110 EC
21,610
20,900
20,530
22,070
23,700
687
20,900
20,530
22,070
23,700
687
C110
19,010
18,390
18,070
19,420
20,190
605
Q125
21,610
20,900
20,530
22,070
23,700
687
Q125 HC
23,370
20,900
20,530
22,070
23,700
687
22,580
22,180
23,840
24,730
742
N80
15,800
15,560
15,180
16,180
15,120
503
L80
15,800
15,560
15,180
16,180
17,500
503
L80 1Cr
15,800
15,560
15,180
16,180
17,500
503
N/A
39
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
21.38
0.500
6.283
3.375
15.00
14.88
0.296
4.374
4.283
IP
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
15,560
15,180
16,180
17,500
503
L80 IRP
15,800
15,560
15,180
16,180
17,500
503
L80 HCE
17,900
17,010
16,610
17,700
17,500
550
C90
17,780
17,500
17,080
18,210
20,450
565
C95/R95
18,770
18,470
18,030
19,220
19,460
597
T95
18,770
18,470
18,030
19,220
21,600
597
T95 HC
20,750
18,470
18,030
19,220
21,600
597
18,770
19,440
18,980
20,230
21,600
628
20,750
19,440
18,980
20,230
21,600
628
P110
21,730
21,390
20,880
22,250
25,870
691
P110 MS
21,730
21,390
20,880
22,250
25,870
691
P110 EC
24,690
24,310
23,730
25,280
27,940
785
24,310
23,730
25,280
27,940
785
C110
21,730
21,390
20,880
22,250
23,800
691
Q125
24,690
24,310
23,730
25,280
27,940
785
Q125 HC
27,780
24,310
23,730
25,280
27,940
785
26,250
25,620
27,310
29,160
848
293
J55
5,560
5,700
5,660
6,220
5,770
241
5,700
207
5,700
223
2,220
5,700
K55
5,560
5,700
5,660
6,220
7,300
241
5,700
228
5,700
246
2,460
5,700
359
N80
7,250
8,290
8,230
9,050
7,780
350
8,290
291
8,290
311
3,100
8,290
396
L80
7,250
8,290
8,230
9,050
8,940
350
8,290
286
8,290
295
2,950
8,290
379
L80 1Cr
7,250
8,290
8,230
9,050
8,940
350
8,290
286
8,290
295
2,950
8,290
379
L80 HC
8,510
8,290
8,230
9,050
8,940
350
8,290
286
8,290
295
2,950
8,290
379
L80 IRP
7,250
8,290
8,230
9,050
8,940
350
8,290
286
8,290
295
2,950
8,290
379
L80 HCE
8,510
9,070
9,000
9,900
8,940
383
9,070
286
9,070
295
2,950
9,070
379
C90
7,830
9,320
9,260
10,190
10,400
394
9,320
311
9,320
311
3,100
9,320
404
8,110
9,840
9,780
10,750
9,950
416
9,840
326
9,840
326
3,260
9,840
424
T95
8,110
9,840
9,780
10,750
10,990
416
9,840
326
9,840
326
3,260
9,840
424
T95 HC
9,540
9,840
9,780
10,750
10,990
416
9,840
326
9,840
326
3,260
9,840
424
T95 E
8,110
10,360
10,290
11,320
10,990
437
10,360
326
10,360
326
3,260
10,360
424
T95 HCE
9,540
10,360
10,290
11,320
10,990
437
10,360
326
10,360
326
3,260
10,360
424
N/A C95/R95
P110
8,850
11,400
11,320
12,450
13,170
481
11,400
387
11,400
388
3,880
11,400
503
P110 MS
8,850
11,400
11,320
12,450
13,170
481
11,400
387
11,400
388
3,880
11,400
503
P110 EC
9,480
12,950
12,860
14,150
14,220
547
12,950
387
12,950
388
3,880
12,950
503
12,950
12,860
14,150
14,220
547
12,950
387
12,950
388
3,880
12,950
503
12,950
12,860
14,150
14,220
547
12,950
420
12,950
420
4,190
12,950
548
Q125
STC short round thread casing
LC long round thread casing
BC buttress thread casing
8rd LC
JT
Strength
17,900
8rd STC
L80 HC
T95 E
4 1/2 21.50
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
9,480
40
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
5
18.00
14.88
17.95
(in)
0.296
0.362
(in2)
4.374
5.275
API
ALT.
(in)
(in)
4.283
4.151
N/A
N/A
Rev 05.2011
15.00
Area
PE
(lb/ft)
Pipe Body
Drift
21.40
21.32
0.437
6.264
4.001
N/A
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
11,400
12,950
12,860
14,150
14,220
547
12,950
420
12,950
420
4,190
12,950
548
Q125 HC
13,990
13,890
15,280
14,840
591
13,990
420
13,990
420
4,190
13,990
548
N80
10,500
10,140
10,030
10,940
9,600
422
10,140
396
3,960
9,910
477
L80
10,500
10,140
10,030
10,940
11,050
422
10,140
376
3,760
9,910
457
L80 1Cr
10,500
10,140
10,030
10,940
11,050
422
10,140
376
3,760
9,910
457
L80 HC
11,400
10,140
10,030
10,940
11,050
422
10,140
376
3,760
9,910
457
L80 IRP
10,500
10,140
10,030
10,940
11,050
422
10,140
376
3,760
9,910
457
L80 HCE
11,400
11,090
10,970
11,960
11,050
462
10,810
376
3,760
9,910
457
C90
11,520
11,400
11,290
12,310
12,870
475
11,400
396
3,960
11,150
487
C95/R95
12,020
12,040
11,910
12,990
12,290
501
12,040
416
4,160
11,770
512
T95
12,020
12,040
11,910
12,990
13,600
501
12,040
416
4,160
11,770
512
T95 HC
12,670
12,040
11,910
12,990
13,600
501
12,040
416
4,160
11,770
512
T95 E
12,020
12,670
12,540
13,670
13,600
527
12,670
416
4,160
11,770
512
T95 HCE
12,670
12,670
12,540
13,670
13,600
527
12,670
416
4,160
11,770
512
P110
13,470
13,940
13,800
15,040
16,290
580
13,940
495
4,950
13,630
606
P110 MS
13,470
13,940
13,800
15,040
16,290
580
13,940
495
4,950
13,630
606
P110 EC
14,820
15,840
15,680
17,090
17,590
659
14,870
495
4,950
13,630
606
15,840
15,680
17,090
17,590
659
14,870
495
4,950
13,630
606
C110
13,470
13,940
13,800
15,040
14,980
580
13,940
456
4,550
13,630
566
Q125
14,820
15,840
15,680
17,090
17,590
659
15,840
535
5,340
15,490
661
Q125 HC
15,670
15,840
15,680
17,090
17,590
659
15,840
535
5,340
15,490
661
17,100
16,930
18,460
18,350
712
15,990
535
5,340
15,490
661
12,240
12,060
13,020
11,710
501
10,810
490
4,900
9,910
537
N80
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
12,760
L80
12,760
12,240
12,060
13,020
13,500
501
10,810
466
4,650
9,910
510
L80 1Cr
12,760
12,240
12,060
13,020
13,500
501
10,810
466
4,650
9,910
510
L80 HC
13,960
12,240
12,060
13,020
13,500
501
10,810
466
4,650
9,910
510
L80 IRP
12,760
12,240
12,060
13,020
13,500
501
10,810
466
4,650
9,910
510
L80 HCE
13,960
13,380
13,190
14,240
13,500
548
10,810
466
4,650
9,910
510
C90
14,360
13,770
13,560
14,650
15,740
564
12,170
490
4,900
11,150
537
C95/R95
15,150
14,530
14,320
15,460
15,010
595
12,840
515
5,140
11,770
564
T95
15,150
14,530
14,320
15,460
16,630
595
12,840
515
5,140
11,770
564
T95 HC
15,950
14,530
14,320
15,460
16,630
595
12,840
515
5,140
11,770
564
T95 E
15,150
15,300
15,070
16,270
16,630
626
12,840
515
5,140
11,770
564
T95 HCE
15,950
15,300
15,070
16,270
16,630
626
12,840
515
5,140
11,770
564
P110
17,550
16,820
16,580
17,900
19,920
689
14,870
613
6,120
13,630
671
P110 MS
17,550
16,820
16,580
17,900
19,920
689
14,870
613
6,120
13,630
671
41
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
P110 EC
21.40
21.32
0.437
6.264
4.001
23.20
24.10
23.11
24.05
0.478
0.500
6.791
7.069
3.919
3.875
N/A
IP
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
19,120
18,840
20,340
21,520
783
14,870
613
6,120
13,630
671
671
19,120
18,840
20,340
21,520
783
14,870
613
6,120
13,630
17,550
16,820
16,580
17,900
18,330
689
14,870
564
5,630
13,630
617
Q125
19,940
19,120
18,840
20,340
21,520
783
15,990
662
6,610
15,490
725
Q125 HC
21,540
19,120
18,840
20,340
21,520
783
15,990
662
6,610
15,490
725
20,650
20,340
21,970
22,450
846
15,990
662
6,610
15,490
725
13,380
13,150
14,130
12,870
543
10,810
540
5,400
9,910
537
N/A
N/A
8rd LC
JT
Strength
C110
N80
8rd STC
19,940
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
13,830
L80
13,830
13,380
13,150
14,130
14,870
543
10,810
513
5,130
9,910
510
L80 1Cr
13,830
13,380
13,150
14,130
14,870
543
10,810
513
5,130
9,910
510
L80 HC
15,130
13,380
13,150
14,130
14,870
543
10,810
513
5,130
9,910
510
L80 IRP
13,830
13,380
13,150
14,130
14,870
543
10,810
513
5,130
9,910
510
L80 HCE
15,130
14,640
14,380
15,460
14,870
594
10,810
513
5,130
9,910
510
C90
15,560
15,060
14,790
15,900
17,350
611
12,170
540
5,400
11,150
537
C95/R95
16,430
15,890
15,610
16,780
16,530
645
12,840
567
5,670
11,770
564
T95
16,430
15,890
15,610
16,780
18,330
645
12,840
567
5,670
11,770
564
T95 HC
17,570
15,890
15,610
16,780
18,330
645
12,840
567
5,670
11,770
564
T95 E
16,430
16,730
16,430
17,660
18,330
679
12,840
567
5,670
11,770
564
T95 HCE
17,570
16,730
16,430
17,660
18,330
679
12,840
567
5,670
11,770
564
P110
19,020
18,400
18,080
19,430
21,950
747
14,870
675
6,750
13,630
671
P110 MS
19,020
18,400
18,080
19,430
21,950
747
14,870
675
6,750
13,630
671
P110 EC
21,840
20,910
20,540
22,080
23,710
849
14,870
675
6,750
13,630
671
20,910
20,540
22,080
23,710
849
14,870
675
6,750
13,630
671
18,400
18,080
19,430
20,200
747
14,870
621
6,210
13,630
617
C110
19,020
Q125
21,620
20,910
20,540
22,080
23,710
849
15,990
729
7,290
15,490
725
Q125 HC 23,340
20,910
20,540
22,080
23,710
849
15,990
729
7,290
15,490
725
22,590
22,190
23,850
24,740
917
15,990
729
7,290
15,490
725
N80
14,400
14,000
13,730
14,720
13,510
565
10,810
567
5,660
9,910
537
L80
14,400
14,000
13,730
14,720
15,610
565
10,810
538
5,380
9,910
510
L80 1Cr
14,400
14,000
13,730
14,720
15,610
565
10,810
538
5,380
9,910
510
L80 HC
15,750
14,000
13,730
14,720
15,610
565
10,810
538
5,380
9,910
510
L80 IRP
14,400
14,000
13,730
14,720
15,610
565
10,810
538
5,380
9,910
510
L80 HCE
15,750
15,310
15,020
16,100
15,610
619
10,810
538
5,380
9,910
510
C90
16,200
15,750
15,450
16,560
18,220
636
12,170
567
5,660
11,150
537
C95/R95
17,100
16,630
16,300
17,480
17,360
672
12,840
595
5,950
11,770
564
T95
17,100
16,630
16,300
17,480
19,250
672
12,840
595
5,950
11,770
564
T95 HC
18,470
16,630
16,300
17,480
19,250
672
12,840
595
5,950
11,770
564
42
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
T95 E
24.10
15.36
0.500
0.275
7.069
4.514
3.875
4.825
N/A
5 1/2 17.00
5 1/2 20.00
16.89
19.83
0.304
0.361
4.962
5.828
4.767
4.653
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
17,100
17,500
17,160
18,400
19,250
707
12,840
595
5,950
11,770
564
564
T95 HCE
18,470
17,500
17,160
18,400
19,250
707
12,840
595
5,950
11,770
P110
19,800
19,250
18,880
20,240
23,050
778
14,870
708
7,080
13,630
671
P110 MS 19,800
19,250
18,880
20,240
23,050
778
14,870
708
7,080
13,630
671
22,500
21,880
21,450
23,000
24,900
884
14,870
708
7,080
13,630
671
P110 EC
21,880
21,450
23,000
24,900
884
14,870
708
7,080
13,630
671
19,250
18,880
20,240
21,210
778
14,870
652
6,510
13,630
617
C110
19,800
Q125
22,500
21,880
21,450
23,000
24,900
884
15,990
765
7,650
15,490
725
Q125 HC
24,300
21,880
21,450
23,000
24,900
884
15,990
765
7,650
15,490
725
Rev 05.2011
5 1/2 15.50
24.05
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
23,630
23,170
24,840
25,980
954
15,990
765
7,650
15,490
725
J55
4,040
4,810
4,790
5,300
4,840
248
4,810
202
4,810
217
2,170
4,810
300
K55
4,040
4,810
4,790
5,300
6,130
248
4,810
222
4,810
239
2,390
4,810
366
J55
4,910
5,320
5,290
5,830
5,370
273
5,320
229
5,320
247
2,460
5,320
329
K55
4,910
5,320
5,290
5,830
6,800
273
5,320
252
5,320
272
2,710
5,320
402
N80
6,290
7,740
7,690
8,480
7,250
397
7,740
323
7,740
348
3,470
7,740
446
L80
6,290
7,740
7,690
8,480
8,320
397
7,740
317
7,740
338
3,380
7,740
428
L80 1Cr
6,290
7,740
7,690
8,480
8,320
397
7,740
317
7,740
338
3,380
7,740
428
428
L80 HC
6,630
7,740
7,690
8,480
8,320
397
7,740
317
7,740
338
3,380
7,740
L80 IRP
6,290
7,740
7,690
8,480
8,320
397
7,740
317
7,740
338
3,380
7,740
428
L80 HCE
6,630
8,460
8,410
9,280
8,320
434
8,460
317
8,460
338
3,380
8,460
428
C90
6,730
8,710
8,650
9,540
9,680
447
8,710
349
8,710
356
3,550
8,710
456
C95/R95
6,940
9,190
9,130
10,070
9,260
471
9,190
368
9,190
374
3,730
9,190
480
T95
6,940
9,190
9,130
10,070
10,230
471
9,190
368
9,190
374
3,730
9,190
480
N/A
T95 HC
8,470
9,190
9,130
10,070
10,230
471
9,190
368
9,190
374
3,730
9,190
480
T95 E
6,940
9,670
9,620
10,600
10,230
496
9,670
368
9,670
374
3,730
9,670
480
T95 HCE
8,470
9,670
9,620
10,600
10,230
496
9,670
368
9,670
374
3,730
9,670
480
P110
7,480
10,640
10,580
11,660
12,250
546
10,640
430
10,640
445
4,440
10,640
568
P110 MS
7,480
10,640
10,580
11,660
12,250
546
10,640
430
10,640
445
4,440
10,640
568
P110 EC
8,840
12,090
12,020
13,260
13,230
620
12,090
430
12,090
445
4,440
12,090
568
P110 HCE
9,040
12,090
12,020
13,260
13,230
620
12,090
430
12,090
445
4,440
12,090
568
Q125
7,890
12,090
12,020
13,260
13,230
620
12,090
481
12,090
481
4,800
12,090
620
Q125 HC
9,110
12,090
12,020
13,260
13,230
620
12,090
481
12,090
481
4,800
12,090
620
Q125 HCE
9,110
13,060
12,980
14,320
13,800
670
13,060
481
13,060
481
4,800
13,060
620
N80
8,830
9,190
9,110
9,980
8,670
466
9,190
428
4,270
8,990
524
L80
8,830
9,190
9,110
9,980
9,970
466
9,190
416
4,160
8,990
503
L80 1Cr
8,830
9,190
9,110
9,980
9,970
466
9,190
416
4,160
8,990
503
N/A
43
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
5 1/2 20.00
Area
PE
(lb/ft)
19.83
Pipe Body
Drift
(in)
0.361
(in2)
5.828
API
ALT.
(in)
(in)
4.653
22.56
0.415
6.630
4.545
IP
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
9,190
9,110
9,980
9,970
466
9,190
416
4,160
8,990
503
L80 IRP
8,830
9,190
9,110
9,980
9,970
466
9,190
416
4,160
8,990
503
L80 HCE
9,850
10,050
9,970
10,910
9,970
510
9,870
416
4,160
8,990
503
C90
9,630
10,340
10,250
11,230
11,600
525
10,340
438
4,380
10,120
536
C95/R95
10,020
10,910
10,820
11,850
11,080
554
10,910
460
4,600
10,680
563
T95
10,020
10,910
10,820
11,850
12,250
554
10,910
460
4,600
10,680
563
T95 HC
11,130
10,910
10,820
11,850
12,250
554
10,910
460
4,600
10,680
563
T95 E
10,020
11,490
11,390
12,470
12,250
583
11,490
460
4,600
10,680
563
11,130
11,490
11,390
12,470
12,250
583
11,490
460
4,600
10,680
563
667
P110
11,110
12,640
12,530
13,720
14,680
641
12,640
548
5,470
12,360
P110 MS
11,110
12,640
12,530
13,720
14,680
641
12,640
548
5,470
12,360
667
P110 EC
12,090
14,360
14,240
15,590
15,850
729
13,160
548
5,470
12,360
667
667
14,360
14,240
15,590
15,850
729
13,160
548
5,470
12,360
C110
11,110
12,640
12,530
13,720
13,500
641
12,640
504
5,030
12,360
624
Q125
12,090
14,360
14,240
15,590
15,850
729
13,160
592
5,910
14,050
728
Q125 HC
13,320
14,360
14,240
15,590
15,850
729
13,160
592
5,910
14,050
728
15,510
15,380
16,840
16,540
787
13,160
592
5,910
14,050
728
N80
11,160
10,560
10,450
11,370
10,030
530
9,870
502
5,020
8,990
580
L80
11,160
10,560
10,450
11,370
11,550
530
9,870
489
4,880
8,990
551
L80 1Cr
11,160
10,560
10,450
11,370
11,550
530
9,870
489
4,880
8,990
551
551
L80 HC
12,210
10,560
10,450
11,370
11,550
530
9,870
489
4,880
8,990
L80 IRP
11,160
10,560
10,450
11,370
11,550
530
9,870
489
4,880
8,990
551
L80 HCE
12,210
11,550
11,430
12,430
11,550
580
9,870
489
4,880
8,990
551
C90
12,380
11,880
11,750
12,790
13,450
597
11,110
514
5,140
10,120
580
C95/R95
12,930
12,540
12,410
13,500
12,840
630
11,730
540
5,400
10,680
609
609
T95
12,930
12,540
12,410
13,500
14,210
630
11,730
540
5,400
10,680
T95 HC
13,480
12,540
12,410
13,500
14,210
630
11,730
540
5,400
10,680
609
T95 E
12,930
13,200
13,060
14,210
14,210
663
11,730
540
5,400
10,680
609
T95 HCE
13,480
13,200
13,060
14,210
14,210
663
11,730
540
5,400
10,680
609
P110
14,540
14,530
14,360
15,630
17,020
729
13,160
643
6,420
12,360
725
P110 MS 14,540
14,530
14,360
15,630
17,020
729
13,160
643
6,420
12,360
725
P110 EC
8rd LC
JT
Strength
9,850
N/A
8rd STC
L80 HC
5 1/2 23.00
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
16,220
16,510
16,320
17,760
18,380
829
13,160
643
6,420
12,360
725
16,510
16,320
17,760
18,380
829
13,160
643
6,420
12,360
725
C110
14,540
14,530
14,360
15,630
15,660
729
13,160
592
5,910
12,360
667
Q125
16,060
16,510
16,320
17,760
18,380
829
13,160
694
6,940
14,050
783
Q125 HC
17,610
16,510
16,320
17,760
18,380
829
13,160
694
6,940
14,050
783
17,830
17,630
19,180
19,180
895
13,160
694
6,940
14,050
783
44
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
5 1/2 26.00
Area
PE
(lb/ft)
25.56
Pipe Body
Drift
(in)
0.476
(in2)
7.513
API
ALT.
(in)
(in)
4.423
N/A
Rev 05.2011
0.500
7.854
4.375
N/A
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
12,650
12,120
11,940
12,900
11,590
601
L80
12,650
12,120
11,940
12,900
13,360
601
L80 1Cr
12,650
12,120
11,940
12,900
13,360
601
L80 HC
13,830
12,120
11,940
12,900
13,360
601
L80 IRP
12,650
12,120
11,940
12,900
13,360
601
L80 HCE
13,830
13,250
13,060
14,110
13,360
657
C90
14,230
13,630
13,430
14,520
15,580
676
C95/R95
15,020
14,390
14,180
15,320
14,860
714
T95
15,020
14,390
14,180
15,320
16,460
714
T95 HC
15,810
14,390
14,180
15,320
16,460
714
T95 E
15,020
15,150
14,930
16,130
16,460
751
T95 HCE
15,810
15,150
14,930
16,130
16,460
751
P110
17,390
16,660
16,420
17,740
19,710
826
P110 MS
17,390
16,660
16,420
17,740
19,710
826
P110 EC
19,760
18,930
18,660
20,160
21,290
939
18,930
18,660
20,160
21,290
939
17,390
16,660
16,420
17,740
18,140
826
Q125
19,760
18,930
18,660
20,160
21,290
939
Q125 HC
21,340
18,930
18,660
20,160
21,290
939
20,450
20,150
21,770
22,220
1,014
C110
26.73
8rd STC
N80
5 1/2 26.80
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
N80
13,220
12,730
12,520
13,500
12,200
628
L80
13,220
12,730
12,520
13,500
14,080
628
L80 1Cr
13,220
12,730
12,520
13,500
14,080
628
L80 HC
14,460
12,730
12,520
13,500
14,080
628
L80 IRP
13,220
12,730
12,520
13,500
14,080
628
L80 HCE
14,460
13,920
13,700
14,760
14,080
687
C90
14,880
14,320
14,090
15,190
16,430
707
C95/R95
15,700
15,110
14,870
16,030
15,660
746
T95
15,700
15,110
14,870
16,030
17,360
746
T95 HC
16,600
15,110
14,870
16,030
17,360
746
T95 E
15,700
15,910
15,650
16,870
17,360
785
T95 HCE
16,600
15,910
15,650
16,870
17,360
785
P110
18,180
17,500
17,220
18,560
20,790
864
P110 MS
18,180
17,500
17,220
18,560
20,790
864
P110 EC
20,660
19,890
19,570
21,090
22,450
982
19,890
19,570
21,090
22,450
982
45
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
5 1/2 26.80
5 1/2 29.70
5 1/2 32.60
Area
PE
(lb/ft)
26.73
29.67
32.57
Pipe Body
Drift
(in)
0.500
0.562
0.625
(in2)
7.854
8.718
9.572
API
ALT.
(in)
(in)
4.375
4.251
4.125
N/A
N/A
N/A
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
C110
18,180
17,500
17,220
18,560
19,130
864
Q125
20,660
19,890
19,570
21,090
22,450
982
Q125 HC
22,310
19,890
19,570
21,090
22,450
982
21,480
21,130
22,780
23,430
1,060
N80
14,680
14,310
14,020
15,010
13,820
697
L80
14,680
14,310
14,020
15,010
15,970
697
L80 1Cr
14,680
14,310
14,020
15,010
15,970
697
L80 HC
16,050
14,310
14,020
15,010
15,970
697
L80 IRP
14,680
14,310
14,020
15,010
15,970
697
L80 HCE
16,050
15,650
15,330
16,420
15,970
763
C90
16,510
16,090
15,770
16,890
18,650
785
C95/R95
17,430
16,990
16,640
17,820
17,770
828
T95
17,430
16,990
16,640
17,820
19,710
828
T95 HC
18,920
16,990
16,640
17,820
19,710
828
T95 E
17,430
17,880
17,520
18,760
19,710
872
T95 HCE
18,920
17,880
17,520
18,760
19,710
872
P110
20,180
19,670
19,270
20,640
23,600
959
P110 MS
20,180
19,670
19,270
20,640
23,600
959
P110 EC
22,940
22,350
21,900
23,450
25,490
1,090
22,350
21,900
23,450
25,490
1,090
C110
20,180
19,670
19,270
20,640
21,720
959
Q125
22,940
22,350
21,900
23,450
25,490
1,090
Q125 HC
25,260
22,350
21,900
23,450
25,490
1,090
24,140
23,650
25,330
26,600
1,177
N80
16,120
15,910
15,510
16,510
15,490
766
L80
16,120
15,910
15,510
16,510
17,930
766
L80 1Cr
16,120
15,910
15,510
16,510
17,930
766
L80 HC
18,340
15,910
15,510
16,510
17,930
766
L80 IRP
16,120
15,910
15,510
16,510
17,930
766
L80 HCE
18,340
17,400
16,970
18,060
17,930
838
C90
18,130
17,900
17,450
18,570
20,960
861
C95/R95
19,140
18,890
18,420
19,610
19,940
909
T95
19,140
18,890
18,420
19,610
22,140
909
T95 HC
21,270
18,890
18,420
19,610
22,140
909
T95 E
19,140
19,890
19,390
20,640
22,140
957
T95 HCE
21,270
19,890
19,390
20,640
22,140
957
46
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
32.57
(in)
0.625
(in2)
9.572
API
ALT.
(in)
(in)
4.125
N/A
Rev 05.2011
5 1/2 32.60
Area
PE
(lb/ft)
Pipe Body
Drift
5 1/2 35.70
35.35
N/A
0.352
6.937
5.796
N/A
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
22,160
21,880
21,330
22,700
26,520
1,053
P110 MS
22,160
21,880
21,330
22,700
26,520
1,053
P110 EC
25,180
24,860
24,240
25,800
28,640
1,197
24,860
24,240
25,800
28,640
1,197
C110
22,160
21,880
21,330
22,700
24,400
1,053
Q125
25,180
24,860
24,240
25,800
28,640
1,197
Q125 HC
28,490
24,860
24,240
25,800
28,640
1,197
26,850
26,180
27,860
29,890
1,292
N80
17,490
17,490
16,960
17,950
17,160
831
L80
17,490
17,490
16,960
17,950
19,890
831
L80 1Cr
17,490
17,490
16,960
17,950
19,890
831
L80 HC
20,320
17,490
16,960
17,950
19,890
831
L80 IRP
17,490
17,490
16,960
17,950
19,890
831
L80 HCE
20,320
19,130
18,550
19,630
19,890
909
C90
19,680
19,670
19,080
20,190
23,280
935
C95/R95 20,770
20,770
20,140
21,320
22,120
987
20,770
20,140
21,320
24,590
987
T95
20,770
T95 HC
23,580
20,770
20,140
21,320
24,590
987
T95 E
20,770
21,860
21,200
22,440
24,590
1,039
T95 HCE
23,580
21,860
21,200
22,440
24,590
1,039
P110
24,050
24,050
23,320
24,680
29,460
1,143
P110 MS
24,050
24,050
23,320
24,680
29,460
1,143
P110 EC
27,330
27,320
26,500
28,050
31,810
1,298
27,320
26,500
28,050
31,810
1,298
24,050
24,050
23,320
24,680
27,100
1,143
Q125
27,330
27,320
26,500
28,050
31,810
1,298
Q125 HC
31,650
27,320
26,500
28,050
31,810
1,298
29,510
28,620
30,290
33,190
1,402
C110
23.60
8rd STC
P110
6 5/8 24.00
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
J55
4,560
5,110
5,090
5,620
5,160
382
5,110
314
5,110
340
3,400
5,110
453
K55
4,560
5,110
5,090
5,620
6,530
382
5,110
342
5,110
372
3,720
5,110
548
N80
5,760
7,440
7,400
8,170
6,960
555
7,440
443
7,440
481
4,800
7,440
615
L80
5,760
7,440
7,400
8,170
7,990
555
7,440
436
7,440
473
4,720
7,440
592
L80 1Cr
5,760
7,440
7,400
8,170
7,990
555
7,440
436
7,440
473
4,720
7,440
592
L80 HC
7,170
7,440
7,400
8,170
7,990
555
7,440
436
7,440
473
4,720
7,440
592
L80 IRP
5,760
7,440
7,400
8,170
7,990
555
7,440
436
7,440
473
4,720
7,440
592
L80 HCE
7,170
8,140
8,090
8,940
7,990
607
8,140
436
8,140
473
4,720
8,140
592
47
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
C90
6 5/8 24.00
6 5/8 28.00
23.60
27.67
0.352
0.417
6.937
8.133
5.796
5.666
N/A
N/A
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
6,140
8,370
8,320
9,190
9,290
624
8,370
481
8,370
520
5,190
8,370
633
C95/R95
6,310
8,830
8,780
9,700
8,880
659
8,830
507
8,830
546
5,450
8,830
665
T95
6,310
8,830
8,780
9,700
9,810
659
8,830
507
8,830
546
5,450
8,830
665
T95 HC
7,850
8,830
8,780
9,700
9,810
659
8,830
507
8,830
546
5,450
8,830
665
T95 E
6,310
9,300
9,250
10,210
9,810
694
9,300
507
9,300
546
5,450
9,300
665
T95 HCE
7,850
9,300
9,250
10,210
9,810
694
9,300
507
9,300
546
5,450
9,300
665
P110
6,730
10,230
10,170
11,230
11,750
763
10,230
592
10,230
641
6,410
10,230
786
P110 MS
6,730
10,230
10,170
11,230
11,750
763
10,230
592
10,230
641
6,410
10,230
786
P110 EC
7,580
11,620
11,560
12,770
12,690
867
11,620
592
11,620
641
6,410
11,620
786
786
P110 HCE
7,980
11,620
11,560
12,770
12,690
867
11,620
592
11,620
641
6,410
11,620
C110
6,730
10,230
10,170
11,230
10,810
763
10,230
577
10,230
598
5,970
10,230
739
Q125
7,020
11,620
11,560
12,770
12,690
867
11,620
662
11,620
702
7,010
11,620
860
Q125 HC
8,850
11,620
11,560
12,770
12,690
867
11,620
662
11,620
702
7,010
11,620
860
Q125 HCE
8,850
12,550
12,480
13,790
13,250
936
11,820
662
11,820
702
7,010
12,550
860
J55
6,170
6,060
6,010
6,600
6,150
447
6,060
415
4,140
6,060
531
K55
6,170
6,060
6,010
6,600
7,790
447
6,060
454
4,530
6,060
643
N80
8,170
8,810
8,740
9,590
8,300
651
8,810
586
5,850
8,810
721
L80
8,170
8,810
8,740
9,590
9,540
651
8,810
576
5,760
8,810
693
L80 1Cr
8,170
8,810
8,740
9,590
9,540
651
8,810
576
5,760
8,810
693
L80 HC
9,260
8,810
8,740
9,590
9,540
651
8,810
576
5,760
8,810
693
L80 IRP
8,170
8,810
8,740
9,590
9,540
651
8,810
576
5,760
8,810
693
L80 HCE
9,260
9,640
9,560
10,490
9,540
712
9,640
576
5,760
9,640
693
C90
8,880
9,910
9,840
10,790
11,100
732
9,910
633
6,330
9,910
742
C95/R95
9,220
10,460
10,380
11,390
10,610
773
10,460
665
6,640
10,460
780
T95
9,220
10,460
10,380
11,390
11,720
773
10,460
665
6,640
10,460
780
T95 HC
10,490
10,460
10,380
11,390
11,720
773
10,460
665
6,640
10,460
780
T95 E
9,220
11,020
10,930
11,990
11,720
813
11,020
665
6,640
11,020
780
T95 HCE
10,490
11,020
10,930
11,990
11,720
813
11,020
665
6,640
11,020
780
922
P110
10,160
12,120
12,020
13,190
14,040
895
11,820
781
7,810
12,120
P110 MS
10,160
12,120
12,020
13,190
14,040
895
11,820
781
7,810
12,120
922
P110 EC
11,000
13,770
13,660
14,990
15,170
1,017
11,820
781
7,810
13,500
922
13,770
13,660
14,990
15,170
1,017
11,820
781
7,810
13,500
922
12,120
12,020
13,190
12,920
895
11,820
728
7,280
12,120
866
1,008
C110
10,160
Q125
11,000
13,770
13,660
14,990
15,170
1,017
11,820
855
8,540
13,770
Q125 HC
12,920
13,770
13,660
14,990
15,170
1,017
11,820
855
8,540
13,770
1,008
14,870
14,760
16,190
15,830
1,098
11,820
855
8,540
14,780
1,008
48
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
N80
6 5/8 32.00
31.23
0.475
9.177
5.550
N/A
Rev 05.2011
34.23
N/A
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
10,320
10,040
9,940
10,840
9,500
734
10,040
678
6,770
9,810
814
L80
10,320
10,040
9,940
10,840
10,940
734
10,040
666
6,660
9,810
783
L80 1Cr
10,320
10,040
9,940
10,840
10,940
734
10,040
666
6,660
9,810
783
L80 HC
11,080
10,040
9,940
10,840
10,940
734
10,040
666
6,660
9,810
783
L80 IRP
10,320
10,040
9,940
10,840
10,940
734
10,040
666
6,660
9,810
783
L80 HCE
11,080
10,980
10,870
11,860
10,940
803
10,660
666
6,660
9,810
783
C90
11,330
11,290
11,180
12,190
12,740
826
11,290
732
7,320
11,040
837
C95/R95
11,820
11,920
11,800
12,870
12,160
872
11,820
769
7,690
11,660
880
T95
11,820
11,920
11,800
12,870
13,460
872
11,820
769
7,690
11,660
880
T95 HC
12,520
11,920
11,800
12,870
13,460
872
11,820
769
7,690
11,660
880
T95 E
11,820
12,550
12,420
13,550
13,460
918
11,820
769
7,690
11,660
880
T95 HCE
12,520
12,550
12,420
13,550
13,460
918
11,820
769
7,690
11,660
880
P110
13,230
13,800
13,660
14,900
16,120
1,010
11,820
904
9,030
13,500
1,040
P110 MS
13,230
13,800
13,660
14,900
16,120
1,010
11,820
904
9,030
13,500
1,040
P110 EC
14,540
15,680
15,530
16,940
17,410
1,147
11,820
904
9,030
13,500
1,040
6 5/8 35.00
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
15,680
15,530
16,940
17,410
1,147
11,820
904
9,030
13,500
1,040
C110
13,230
13,800
13,660
14,900
14,830
1,010
11,820
842
8,420
13,500
977
Q125
14,540
15,680
15,530
16,940
17,410
1,147
11,820
989
9,880
14,780
1,138
Q125 HC
15,800
15,680
15,530
16,940
17,410
1,147
11,820
989
9,880
14,780
1,138
16,940
16,770
18,290
18,160
1,239
11,820
989
9,880
14,780
1,138
N80
11,670
11,090
10,960
11,900
10,560
805
L80
11,670
11,090
10,960
11,900
12,160
805
L80 1Cr
11,670
11,090
10,960
11,900
12,160
805
L80 HC
12,770
11,090
10,960
11,900
12,160
805
L80 IRP
11,670
11,090
10,960
11,900
12,160
805
L80 HCE
12,770
12,130
11,990
13,010
12,160
880
C90
13,130
12,480
12,330
13,380
14,170
905
C95/R95 13,860
13,170
13,010
14,130
13,530
956
T95
13,860
13,170
13,010
14,130
14,970
956
T95 HC
14,590
13,170
13,010
14,130
14,970
956
T95 E
13,860
13,870
13,700
14,870
14,970
1,006
T95 HCE
14,590
13,870
13,700
14,870
14,970
1,006
P110
15,870
15,250
15,070
16,360
17,930
1,107
P110 MS
15,870
15,250
15,070
16,360
17,930
1,107
P110 EC
17,600
17,330
17,120
18,590
19,370
1,258
17,330
17,120
18,590
19,370
1,258
49
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
20.00
23.00
26.00
34.23
19.56
22.65
25.69
0.272
0.317
0.362
5.749
6.655
7.549
6.331
N/A
6.151
N/A
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
15,250
15,070
16,360
16,500
1,107
Q125
17,600
17,330
17,120
18,590
19,370
1,258
Q125 HC
18,700
17,330
17,120
18,590
19,370
1,258
18,720
18,490
20,070
20,210
1,358
N/A
6.241 6.250
8rd STC
15,870
C110
6 5/8 35.00
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
J55
2,270
3,740
3,730
4,160
3,740
316
3,740
234
K55
2,270
3,740
3,730
4,160
4,730
316
3,740
254
J55
3,270
4,360
4,340
4,820
4,370
366
4,360
284
4,360
313
3,120
4,360
432
K55
3,270
4,360
4,340
4,820
5,540
366
4,360
309
4,360
341
3,410
4,360
522
N80
3,830
6,340
6,310
7,010
5,900
532
6,340
402
6,340
442
4,410
6,340
588
L80
3,830
6,340
6,310
7,010
6,770
532
6,340
396
6,340
435
4,340
6,340
565
L80 1Cr
3,830
6,340
6,310
7,010
6,770
532
6,340
396
6,340
435
4,340
6,340
565
L80 HC
3,920
6,340
6,310
7,010
6,770
532
6,340
396
6,340
435
4,340
6,340
565
565
L80 IRP
3,830
6,340
6,310
7,010
6,770
532
6,340
396
6,340
435
4,340
6,340
L80 HCE
3,920
6,930
6,910
7,670
6,770
582
6,930
396
6,930
435
4,340
6,930
565
C90
4,030
7,130
7,100
7,890
7,860
599
7,130
437
7,130
479
4,790
7,130
605
C95/R95
4,150
7,530
7,500
8,330
7,530
632
7,530
460
7,530
505
5,050
7,530
636
T95
4,150
7,530
7,500
8,330
8,310
632
7,530
460
7,530
505
5,050
7,530
636
T95 HC
5,440
7,530
7,500
8,330
8,310
632
7,530
460
7,530
505
5,050
7,530
636
T95 E
4,150
7,930
7,890
8,770
8,310
666
7,930
460
7,930
505
5,050
7,930
636
T95 HCE
5,440
7,930
7,890
8,770
8,310
666
7,930
460
7,930
505
5,050
7,930
636
P110
4,440
8,720
8,680
9,640
9,950
732
8,720
537
8,720
590
5,890
8,720
752
P110 MS
4,440
8,720
8,680
9,640
9,950
732
8,720
537
8,720
590
5,890
8,720
752
P110 EC
5,690
9,910
9,870
10,960
10,750
832
9,520
537
9,520
590
5,890
9,910
752
P110 HCE
5,690
9,910
9,870
10,960
10,750
832
9,520
537
9,520
590
5,890
9,910
752
C110
4,440
8,720
8,680
9,640
9,150
732
8,720
524
8,720
558
5,570
8,720
707
Q125
4,650
9,910
9,870
10,960
10,750
832
9,520
601
9,520
655
6,540
9,910
823
Q125 HC
5,760
9,910
9,870
10,960
10,750
832
9,520
601
9,520
655
6,540
9,910
823
Q125 HCE
5,760
10,700
10,660
11,840
11,210
898
9,520
601
9,520
655
6,540
10,700
823
490
J55
4,330
4,980
4,950
5,470
5,010
415
4,980
334
4,980
367
3,670
4,980
K55
4,330
4,980
4,950
5,470
6,350
415
4,980
364
4,980
401
4,000
4,980
592
N80
5,410
7,240
7,200
7,960
6,770
604
7,240
472
7,240
519
5,190
7,240
667
L80
5,410
7,240
7,200
7,960
7,770
604
7,240
465
7,240
511
5,100
7,240
641
L80 1Cr
5,410
7,240
7,200
7,960
7,770
604
7,240
465
7,240
511
5,100
7,240
641
L80 HC
5,520
7,240
7,200
7,960
7,770
604
7,240
465
7,240
511
5,100
7,240
641
L80 IRP
5,410
7,240
7,200
7,960
7,770
604
7,240
465
7,240
511
5,100
7,240
641
L80 HCE
5,520
7,920
7,880
8,710
7,770
661
7,920
465
7,920
511
5,100
7,920
641
50
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
26.00
25.69
(in)
0.362
(in2)
7.549
API
ALT.
(in)
(in)
6.151
N/A
Rev 05.2011
Area
PE
(lb/ft)
Pipe Body
Drift
29.00
28.75
0.408
8.449
6.059 6.125
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
C90
5,740
8,150
8,100
8,960
9,030
679
8,150
513
8,150
563
5,630
8,150
687
C95/R95
5,890
8,600
8,550
9,460
8,640
717
8,600
541
8,600
593
5,930
8,600
722
T95
5,890
8,600
8,550
9,460
9,540
717
8,600
541
8,600
593
5,930
8,600
722
T95 HC
7,420
8,600
8,550
9,460
9,540
717
8,600
541
8,600
593
5,930
8,600
722
T95 E
5,890
9,050
9,000
9,950
9,540
755
9,050
541
9,050
593
5,930
9,050
722
T95 HCE
7,420
9,050
9,000
9,950
9,540
755
9,050
541
9,050
593
5,930
9,050
722
P110
6,230
9,960
9,900
10,950
11,430
830
9,520
631
9,520
693
6,920
9,960
853
P110 MS
6,230
9,960
9,900
10,950
11,430
830
9,520
631
9,520
693
6,920
9,960
853
P110 EC
8,030
11,310
11,250
12,440
12,340
944
9,520
631
9,520
693
6,920
11,310
853
P110 HCE
8,260
11,310
11,250
12,440
12,340
944
9,520
631
9,520
693
6,920
11,310
853
C110
6,230
9,960
9,900
10,950
10,510
830
9,520
616
9,520
655
6,550
9,960
802
Q125
6,450
11,310
11,250
12,440
12,340
944
9,520
707
9,520
769
7,690
11,310
934
Q125 HC
8,260
11,310
11,250
12,440
12,340
944
9,520
707
9,520
769
7,690
11,310
934
Q125 HCE
8,260
12,220
12,150
13,440
12,880
1,019
9,520
707
9,520
769
7,690
11,790
934
N80
7,030
8,160
8,110
8,920
7,660
676
8,160
597
5,970
8,160
746
L80
7,030
8,160
8,110
8,920
8,800
676
8,160
587
5,870
8,160
718
L80 1Cr
7,030
8,160
8,110
8,920
8,800
676
8,160
587
5,870
8,160
718
718
L80 HC
7,300
8,160
8,110
8,920
8,800
676
8,160
587
5,870
8,160
L80 IRP
7,030
8,160
8,110
8,920
8,800
676
8,160
587
5,870
8,160
718
L80 HCE
7,300
8,930
8,870
9,760
8,800
739
8,930
587
5,870
8,460
718
C90
7,580
9,180
9,120
10,040
10,230
760
9,180
648
6,470
9,180
768
C95/R95
7,840
9,690
9,630
10,590
9,780
803
9,520
683
6,820
9,690
808
T95
7,840
9,690
9,630
10,590
10,810
803
9,520
683
6,820
9,690
808
T95 HC
9,300
9,690
9,630
10,590
10,810
803
9,520
683
6,820
9,690
808
T95 E
7,840
10,200
10,130
11,150
10,810
845
9,520
683
6,820
10,040
808
T95 HCE
9,300
10,200
10,130
11,150
10,810
845
9,520
683
6,820
10,040
808
P110
8,530
11,220
11,150
12,270
12,950
929
9,520
797
7,960
11,220
955
P110 MS
8,530
11,220
11,150
12,270
12,950
929
9,520
797
7,960
11,220
955
955
P110 EC
9,580
12,750
12,670
13,940
13,990
1,056
9,520
797
7,960
11,630
P110 HCE
9,760
12,750
12,670
13,940
13,990
1,056
9,520
797
7,960
11,630
955
C110
8,530
11,220
11,150
12,270
11,920
929
9,520
754
7,530
11,220
898
Q125
9,110
12,750
12,670
13,940
13,990
1,056
9,520
885
8,840
11,790
1,045
Q125 HC
9,760
12,750
12,670
13,940
13,990
1,056
9,520
885
8,840
11,790
1,045
Q125 HCE
9,760
13,770
13,680
15,050
14,600
1,141
9,520
885
8,840
11,790
1,045
51
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
N80
32.00
31.70
0.453
9.317
5.969 6.000
34.61
N/A
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
9,060
8,990
9,850
8,540
745
9,060
672
6,720
8,460
823
L80
8,610
9,060
8,990
9,850
9,820
745
9,060
661
6,610
8,460
791
L80 1Cr
8,610
9,060
8,990
9,850
9,820
745
9,060
661
6,610
8,460
791
L80 HC
9,610
9,060
8,990
9,850
9,820
745
9,060
661
6,610
8,460
791
L80 IRP
8,610
9,060
8,990
9,850
9,820
745
9,060
661
6,610
8,460
791
L80 HCE
9,610
9,910
9,830
10,770
9,820
815
9,240
661
6,610
8,460
791
C90
9,370
10,190
10,110
11,080
11,430
839
9,520
729
7,290
9,510
847
C95/R95
9,740
10,760
10,670
11,690
10,920
885
9,520
768
7,680
10,040
891
T95
9,740
10,760
10,670
11,690
12,070
885
9,520
768
7,680
10,040
891
T95 HC
10,910
10,760
10,670
11,690
12,070
885
9,520
768
7,680
10,040
891
T95 E
9,740
11,330
11,230
12,310
12,070
932
9,520
768
7,680
10,040
891
T95 HCE
10,910
11,330
11,230
12,310
12,070
932
9,520
768
7,680
10,040
891
1,053
P110
10,780
12,460
12,360
13,540
14,460
1,025
9,520
897
8,970
11,630
P110 MS
10,780
12,460
12,360
13,540
14,460
1,025
9,520
897
8,970
11,630
1,053
P110 EC
11,710
14,160
14,040
15,390
15,620
1,165
9,520
897
8,970
11,630
1,053
14,160
14,040
15,390
15,620
1,165
9,520
897
8,970
11,630
1,053
10,780
12,460
12,360
13,540
13,300
1,025
9,520
848
8,480
11,630
990
Q125
11,710
14,160
14,040
15,390
15,620
1,165
9,520
996
9,960
11,790
1,152
Q125 HC
12,620
14,160
14,040
15,390
15,620
1,165
9,520
996
9,960
11,790
1,152
15,290
15,160
16,620
16,300
1,258
9,520
996
9,960
11,790
1,152
C110
35.00
8rd STC
8,610
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
N80
10,190
9,960
9,860
10,760
9,430
814
9,240
746
7,460
8,460
876
L80
10,190
9,960
9,860
10,760
10,850
814
9,240
734
7,340
8,460
832
L80 1Cr
10,190
9,960
9,860
10,760
10,850
814
9,240
734
7,340
8,460
832
L80 HC
11,330
9,960
9,860
10,760
10,850
814
9,240
734
7,340
8,460
832
L80 IRP
10,190
9,960
9,860
10,760
10,850
814
9,240
734
7,340
8,460
832
L80 HCE
11,330
10,890
10,790
11,770
10,850
890
9,240
734
7,340
8,460
832
C90
11,170
11,210
11,100
12,110
12,630
916
9,520
809
8,090
9,510
876
C95/R95
11,650
11,830
11,710
12,780
12,060
966
9,520
853
8,520
10,040
920
T95
11,650
11,830
11,710
12,780
13,350
966
9,520
853
8,520
10,040
920
T95 HC
12,390
11,830
11,710
12,780
13,350
966
9,520
853
8,520
10,040
920
T95 E
11,650
12,450
12,330
13,450
13,350
1,017
9,520
853
8,520
10,040
920
T95 HCE
12,390
12,450
12,330
13,450
13,350
1,017
9,520
853
8,520
10,040
920
P110
13,030
13,700
13,560
14,800
15,990
1,119
9,520
996
9,950
11,630
1,095
P110 MS
13,030
13,700
13,560
14,800
15,990
1,119
9,520
996
9,950
11,630
1,095
P110 EC
14,310
15,560
15,410
16,810
17,270
1,272
9,520
996
9,950
11,630
1,095
15,560
15,410
16,810
17,270
1,272
9,520
996
9,950
11,630
1,095
52
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
C110
38.00
34.61
37.29
N/A
N/A
Rev 05.2011
35.00
41.00
40.43
N/A
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
13,030
13,700
13,560
14,800
14,710
1,119
9,520
942
9,410
11,630
1,008
1,183
Q125
14,320
15,560
15,410
16,810
17,270
1,272
9,520
1,106
11,050
11,790
Q125 HC
15,500
15,560
15,410
16,810
17,270
1,272
9,520
1,106
11,050
11,790
1,183
16,810
16,640
18,160
18,020
1,373
9,520
1,106
11,050
11,790
1,183
N80
11,390
10,800
10,680
11,600
10,260
877
9,240
814
8,140
8,460
876
L80
11,390
10,800
10,680
11,600
11,820
877
9,240
801
8,010
8,460
832
L80 1Cr
11,390
10,800
10,680
11,600
11,820
877
9,240
801
8,010
8,460
832
L80 HC
13,090
10,800
10,680
11,600
11,820
877
9,240
801
8,010
8,460
832
L80 IRP
11,390
10,800
10,680
11,600
11,820
877
9,240
801
8,010
8,460
832
L80 HCE
13,090
11,810
11,680
12,690
11,820
959
9,240
801
8,010
8,460
832
C90
12,810
12,150
12,010
13,050
13,770
986
9,520
883
8,830
9,510
876
C95/R95
13,430
12,830
12,680
13,780
13,140
1,041
9,520
931
9,300
10,040
920
T95
13,430
12,830
12,680
13,780
14,550
1,041
9,520
931
9,300
10,040
920
T95 HC
13,700
12,830
12,680
13,780
14,550
1,041
9,520
931
9,300
10,040
920
T95 E
13,430
13,500
13,340
14,500
14,550
1,096
9,520
931
9,300
10,040
920
T95 HCE
13,700
13,500
13,340
14,500
14,550
1,096
9,520
931
9,300
10,040
920
P110
15,130
14,850
14,680
15,950
17,430
1,206
9,520
1,087
10,860
11,630
1,095
P110 MS
15,130
14,850
14,680
15,950
17,430
1,206
9,520
1,087
10,860
11,630
1,095
P110 EC
16,740
16,880
16,680
18,130
18,820
1,370
9,520
1,087
10,860
11,630
1,095
16,880
16,680
18,130
18,820
1,370
9,520
1,087
10,860
11,630
1,095
C110
15,130
14,850
14,680
15,950
16,030
1,206
9,520
1,028
10,270
11,630
1,008
Q125
16,740
16,880
16,680
18,130
18,820
1,370
9,520
1,207
12,060
11,790
1,183
Q125 HC
17,770
16,880
16,680
18,130
18,820
1,370
9,520
1,207
12,060
11,790
1,183
18,230
18,010
19,580
19,640
1,479
9,520
1,207
12,060
11,790
1,183
N80
12,350
11,800
11,640
12,590
11,270
950
L80
12,350
11,800
11,640
12,590
12,990
950
L80 1Cr
12,350
11,800
11,640
12,590
12,990
950
L80 HC
13,510
11,800
11,640
12,590
12,990
950
L80 IRP
12,350
11,800
11,640
12,590
12,990
950
L80 HCE
13,510
12,910
12,730
13,770
12,990
1,040
C90
13,890
13,280
13,090
14,170
15,140
1,069
C95/R95 14,660
14,010
13,820
14,950
14,440
1,129
14,010
13,820
14,950
16,000
1,129
T95
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
14,660
T95 HC
15,440
14,010
13,820
14,950
16,000
1,129
T95 E
14,660
14,750
14,550
15,740
16,000
1,188
T95 HCE
15,440
14,750
14,550
15,740
16,000
1,188
53
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
41.00
Area
PE
(lb/ft)
40.43
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
N/A
7 5/8 26.40
42.59
25.59
0.328
7.519
6.844
N/A
N/A
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
16,980
16,230
16,000
17,320
19,160
1,307
P110 MS
16,980
16,230
16,000
17,320
19,160
1,307
P110 EC
19,300
18,440
18,180
19,680
20,690
1,485
18,440
18,180
19,680
20,690
1,485
C110
16,980
16,230
16,000
17,320
17,630
1,307
Q125
19,300
18,440
18,180
19,680
20,690
1,485
Q125 HC 20,840
18,440
18,180
19,680
20,690
1,485
19,910
19,640
21,250
21,590
1,604
12,500
12,310
13,280
11,970
1,001
N80
42.70
8rd STC
P110
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
13,010
L80
13,010
12,500
12,310
13,280
13,810
1,001
L80 1Cr
13,010
12,500
12,310
13,280
13,810
1,001
L80 HC
14,230
12,500
12,310
13,280
13,810
1,001
L80 IRP
13,010
12,500
12,310
13,280
13,810
1,001
L80 HCE
14,230
13,670
13,460
14,520
13,810
1,095
C90
14,640
14,060
13,850
14,940
16,110
1,127
C95/R95
15,450
14,840
14,610
15,770
15,360
1,189
T95
15,450
14,840
14,610
15,770
17,020
1,189
T95 HC
16,260
14,840
14,610
15,770
17,020
1,189
T95 E
15,450
15,630
15,380
16,600
17,020
1,252
T95 HCE
16,260
15,630
15,380
16,600
17,020
1,252
P110
17,890
17,190
16,920
18,260
20,390
1,377
P110 MS
17,890
17,190
16,920
18,260
20,390
1,377
P110 EC
20,330
19,530
19,230
20,750
22,020
1,565
19,530
19,230
20,750
22,020
1,565
17,190
16,920
18,260
18,760
1,377
C110
17,890
Q125
20,330
19,530
19,230
20,750
22,020
1,565
Q125 HC
21,950
19,530
19,230
20,750
22,020
1,565
21,090
20,770
22,410
22,980
1,690
J55
2,890
4,140
4,130
4,590
4,150
414
4,140
315
4,140
346
3,460
4,140
483
K55
2,890
4,140
4,130
4,590
5,250
414
4,140
342
4,140
377
3,760
4,140
581
N80
3,400
6,020
6,000
6,680
5,600
602
6,020
446
6,020
490
4,890
6,020
659
L80
3,400
6,020
6,000
6,680
6,420
602
6,020
440
6,020
482
4,810
6,020
635
L80 1Cr
3,400
6,020
6,000
6,680
6,420
602
6,020
440
6,020
482
4,810
6,020
635
635
L80 HC
3,520
6,020
6,000
6,680
6,420
602
6,020
440
6,020
482
4,810
6,020
L80 IRP
3,400
6,020
6,000
6,680
6,420
602
6,020
440
6,020
482
4,810
6,020
635
L80 HCE
3,520
6,590
6,560
7,300
6,420
658
6,590
440
6,590
482
4,810
6,590
635
54
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
C90
25.59
0.328
7.519
6.844
N/A
Rev 05.2011
7 5/8 26.40
7 5/8 29.70
29.06
0.375
8.541
6.750
N/A
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
3,610
6,780
6,750
7,510
7,450
677
6,780
485
6,780
532
5,310
6,780
681
C95/R95
3,710
7,150
7,130
7,930
7,140
714
7,150
511
7,150
560
5,600
7,150
716
T95
3,710
7,150
7,130
7,930
7,880
714
7,150
511
7,150
560
5,600
7,150
716
T95 HC
4,760
7,150
7,130
7,930
7,880
714
7,150
511
7,150
560
5,600
7,150
716
716
T95 E
3,710
7,530
7,500
8,350
7,880
752
7,530
511
7,530
560
5,600
7,530
T95 HCE
4,760
7,530
7,500
8,350
7,880
752
7,530
511
7,530
560
5,600
7,530
716
P110
3,920
8,280
8,250
9,180
9,430
827
8,280
597
8,280
654
6,540
8,280
845
P110 MS
3,920
8,280
8,250
9,180
9,430
827
8,280
597
8,280
654
6,540
8,280
845
P110 EC
4,900
9,410
9,380
10,430
10,190
940
9,410
597
9,410
654
6,540
9,410
845
P110 HCE
5,210
9,410
9,380
10,430
10,190
940
9,410
597
9,410
654
6,540
9,410
845
C110
3,920
8,280
8,250
9,180
8,680
827
8,280
583
8,280
637
6,360
8,280
797
Q125
4,050
9,410
9,380
10,430
10,190
940
9,410
669
9,410
733
7,320
9,410
926
Q125 HC
5,210
9,410
9,380
10,430
10,190
940
9,410
669
9,410
733
7,320
9,410
926
Q125 HCE
5,210
10,160
10,130
11,270
10,630
1,015
10,160
669
10,160
733
7,320
10,160
926
N80
4,790
6,890
6,850
7,590
6,420
683
6,890
575
5,750
6,890
749
L80
4,790
6,890
6,850
7,590
7,370
683
6,890
567
5,660
6,890
721
L80 1Cr
4,790
6,890
6,850
7,590
7,370
683
6,890
567
5,660
6,890
721
721
L80 HC
4,830
6,890
6,850
7,590
7,370
683
6,890
567
5,660
6,890
L80 IRP
4,790
6,890
6,850
7,590
7,370
683
6,890
567
5,660
6,890
721
L80 HCE
4,830
7,530
7,500
8,300
7,370
747
7,530
567
5,660
7,530
721
C90
5,030
7,750
7,710
8,540
8,570
769
7,750
625
6,250
7,750
773
C95/R95
5,130
8,180
8,140
9,010
8,200
811
8,180
659
6,580
8,180
813
T95
5,130
8,180
8,140
9,010
9,050
811
8,180
659
6,580
8,180
813
T95 HC
6,650
8,180
8,140
9,010
9,050
811
8,180
659
6,580
8,180
813
T95 E
5,130
8,610
8,570
9,490
9,050
854
8,610
659
6,580
8,610
813
T95 HCE
6,650
8,610
8,570
9,490
9,050
854
8,610
659
6,580
8,610
813
P110
5,350
9,470
9,420
10,440
10,840
940
9,470
769
7,680
9,470
960
P110 MS
5,350
9,470
9,420
10,440
10,840
940
9,470
769
7,680
9,470
960
P110 EC
7,360
10,760
10,710
11,860
11,710
1,068
10,760
769
7,680
10,760
960
P110 HCE
7,580
10,760
10,710
11,860
11,710
1,068
10,760
769
7,680
10,760
960
C110
5,350
9,470
9,420
10,440
9,980
940
9,470
748
7,480
9,470
905
Q125
5,670
10,760
10,710
11,860
11,710
1,068
10,760
861
8,610
10,760
1,052
Q125 HC
7,580
10,760
10,710
11,860
11,710
1,068
10,760
861
8,610
10,760
1,052
Q125 HCE
7,580
11,620
11,560
12,810
12,220
1,153
11,620
861
8,610
11,620
1,052
55
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
7 5/8 33.70
7 5/8 39.00
Area
PE
(lb/ft)
33.07
38.08
Pipe Body
Drift
(in)
0.430
(in2)
9.720
API
ALT.
(in)
(in)
6.640
N/A
N/A
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
N80
6,560
7,900
7,850
8,650
7,400
778
7,900
674
6,740
7,900
852
L80
6,560
7,900
7,850
8,650
8,500
778
7,900
664
6,630
7,900
820
L80 1Cr
6,560
7,900
7,850
8,650
8,500
778
7,900
664
6,630
7,900
820
L80 HC
6,930
7,900
7,850
8,650
8,500
778
7,900
664
6,630
7,900
820
L80 IRP
6,560
7,900
7,850
8,650
8,500
778
7,900
664
6,630
7,900
820
L80 HCE
6,930
8,640
8,580
9,460
8,500
850
8,640
664
6,630
8,640
820
C90
7,050
8,880
8,830
9,730
9,890
875
8,880
733
7,320
8,880
880
C95/R95
7,270
9,380
9,320
10,270
9,450
923
9,380
772
7,720
9,380
925
T95
7,270
9,380
9,320
10,270
10,440
923
9,380
772
7,720
9,380
925
T95 HC
8,780
9,380
9,320
10,270
10,440
923
9,380
772
7,720
9,380
925
T95 E
7,270
9,870
9,810
10,810
10,440
972
9,870
772
7,720
9,870
925
T95 HCE
8,780
9,870
9,810
10,810
10,440
972
9,870
772
7,720
9,870
925
1,093
P110
7,870
10,860
10,790
11,890
12,510
1,069
10,860
901
9,010
10,860
P110 MS
7,870
10,860
10,790
11,890
12,510
1,069
10,860
901
9,010
10,860
1,093
P110 EC
9,060
12,340
12,260
13,510
13,510
1,215
11,790
901
9,010
12,340
1,093
P110 HCE
9,330
12,340
12,260
13,510
13,510
1,215
11,790
901
9,010
12,340
1,093
C110
7,870
10,860
10,790
11,890
11,510
1,069
10,860
877
8,770
10,860
1,030
Q125
8,340
12,340
12,260
13,510
13,510
1,215
11,790
1,009
10,090
12,340
1,197
Q125 HC
9,330
12,340
12,260
13,510
13,510
1,215
11,790
1,009
10,090
12,340
1,197
Q125 HCE
9,330
13,320
13,240
14,590
14,100
1,312
11,790
1,009
10,090
12,670
1,197
N80
8,820
9,180
9,100
9,970
8,660
895
9,180
798
7,980
9,180
981
L80
8,820
9,180
9,100
9,970
9,960
895
9,180
786
7,850
9,180
945
L80 1Cr
8,820
9,180
9,100
9,970
9,960
895
9,180
786
7,850
9,180
945
L80 HC
9,420
9,180
9,100
9,970
9,960
895
9,180
786
7,850
9,180
945
L80 IRP
8,820
9,180
9,100
9,970
9,960
895
9,180
786
7,850
9,180
945
L80 HCE
9,420
10,040
9,960
10,900
9,960
979
10,040
786
7,850
9,790
945
C90
9,610
10,330
10,240
11,220
11,590
1,007
10,330
867
8,660
10,330
1,013
C95/R95 10,000
10,900
10,810
11,840
11,070
1,063
10,900
914
9,130
10,900
1,065
T95
10,000
10,900
10,810
11,840
12,240
1,063
10,900
914
9,130
10,900
1,065
T95 HC
11,120
10,900
10,810
11,840
12,240
1,063
10,900
914
9,130
10,900
1,065
T95 E
10,000
11,480
11,380
12,460
12,240
1,119
11,480
914
9,130
11,480
1,065
T95 HCE
11,120
11,480
11,380
12,460
12,240
1,119
11,480
914
9,130
11,480
1,065
P110
11,080
12,620
12,520
13,710
14,660
1,231
11,790
1,066
10,660
12,620
1,258
P110 MS
11,080
12,620
12,520
13,710
14,660
1,231
11,790
1,066
10,660
12,620
1,258
P110 EC
12,180
14,340
14,220
15,580
15,840
1,399
11,790
1,066
10,660
12,670
1,258
14,340
14,220
15,580
15,840
1,399
11,790
1,066
10,660
12,670
1,258
56
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
7 5/8 39.00
38.08
42.43
(in)
(in2)
API
ALT.
(in)
(in)
N/A
N/A
Rev 05.2011
7 5/8 42.80
Area
PE
(lb/ft)
Pipe Body
Drift
N/A
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
11,080
12,620
12,520
13,710
13,490
1,231
11,790
1,038
10,370
12,620
1,186
Q125
12,060
14,340
14,220
15,580
15,840
1,399
11,790
1,194
11,940
12,670
1,379
Q125 HC
13,500
14,340
14,220
15,580
15,840
1,399
11,790
1,194
11,940
12,670
1,379
15,490
15,360
16,820
16,520
1,511
11,790
1,194
11,940
12,670
1,379
N80
10,820
10,320
10,210
11,120
9,780
998
10,320
906
9,050
9,790
1,093
L80
10,820
10,320
10,210
11,120
11,260
998
10,320
891
8,910
9,790
1,053
L80 1Cr
10,820
10,320
10,210
11,120
11,260
998
10,320
891
8,910
9,790
1,053
L80 HC
11,620
10,320
10,210
11,120
11,260
998
10,320
891
8,910
9,790
1,053
L80 IRP
10,820
10,320
10,210
11,120
11,260
998
10,320
891
8,910
9,790
1,053
L80 HCE
11,620
11,290
11,170
12,160
11,260
1,091
10,490
891
8,910
9,790
1,053
C90
11,890
11,610
11,490
12,510
13,120
1,122
11,610
984
9,830
11,010
1,129
C95/R95
12,410
12,250
12,120
13,210
12,520
1,185
11,790
1,037
10,360
11,620
1,187
T95
12,410
12,250
12,120
13,210
13,860
1,185
11,790
1,037
10,360
11,620
1,187
T95 HC
12,960
12,250
12,120
13,210
13,860
1,185
11,790
1,037
10,360
11,620
1,187
T95 E
12,410
12,900
12,760
13,900
13,860
1,247
11,790
1,037
10,360
11,620
1,187
T95 HCE
12,960
12,900
12,760
13,900
13,860
1,247
11,790
1,037
10,360
11,620
1,187
P110
13,930
14,190
14,040
15,290
16,600
1,372
11,790
1,210
12,090
12,670
1,402
P110 MS
13,930
14,190
14,040
15,290
16,600
1,372
11,790
1,210
12,090
12,670
1,402
P110 EC
15,350
16,120
15,950
17,380
17,930
1,559
11,790
1,210
12,090
12,670
1,402
16,120
15,950
17,380
17,930
1,559
11,790
1,210
12,090
12,670
1,402
C110
13,930
14,190
14,040
15,290
15,270
1,372
11,790
1,178
11,770
12,670
1,321
Q125
15,350
16,120
15,950
17,380
17,930
1,559
11,790
1,355
13,550
12,670
1,536
Q125 HC
16,240
16,120
15,950
17,380
17,930
1,559
11,790
1,355
13,550
12,670
1,536
17,410
17,230
18,770
18,710
1,683
11,790
1,355
13,550
12,670
1,536
10,920
10,800
11,730
10,390
1,051
10,490
962
9,610
9,790
1,152
N80
44.71
8rd STC
C110
7 5/8 45.30
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
11,510
L80
11,510
10,920
10,800
11,730
11,960
1,051
10,490
947
9,460
9,790
1,109
L80 1Cr
11,510
10,920
10,800
11,730
11,960
1,051
10,490
947
9,460
9,790
1,109
L80 HC
12,590
10,920
10,800
11,730
11,960
1,051
10,490
947
9,460
9,790
1,109
L80 IRP
11,510
10,920
10,800
11,730
11,960
1,051
10,490
947
9,460
9,790
1,109
L80 HCE
12,590
11,950
11,810
12,830
11,960
1,150
10,490
947
9,460
9,790
1,109
C90
12,950
12,290
12,150
13,190
13,940
1,183
11,790
1,045
10,440
11,010
1,189
C95/R95
13,670
12,970
12,820
13,930
13,310
1,248
11,790
1,101
11,010
11,620
1,251
T95
13,670
12,970
12,820
13,930
14,730
1,248
11,790
1,101
11,010
11,620
1,251
T95 HC
14,290
12,970
12,820
13,930
14,730
1,248
11,790
1,101
11,010
11,620
1,251
T95 E
13,670
13,660
13,490
14,660
14,730
1,314
11,790
1,101
11,010
11,620
1,251
T95 HCE
14,290
13,660
13,490
14,660
14,730
1,314
11,790
1,101
11,010
11,620
1,251
57
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
44.71
N/A
N/A
50.95
N/A
IP
JT
Strength
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
14,840
16,120
17,640
1,445
11,790
1,285
12,850
12,670
1,477
P110 MS 15,440
15,020
14,840
16,120
17,640
1,445
11,790
1,285
12,850
12,670
1,477
P110 EC
17,270
17,070
16,870
18,320
19,050
1,643
11,790
1,285
12,850
12,670
1,477
17,070
16,870
18,320
19,050
1,643
11,790
1,285
12,850
12,670
1,477
C110
15,440
15,020
14,840
16,120
16,230
1,445
11,790
1,251
12,500
12,670
1,392
Q125
17,110
17,070
16,870
18,320
19,050
1,643
11,790
1,439
14,390
12,670
1,619
Q125 HC
18,160
17,070
16,870
18,320
19,050
1,643
11,790
1,439
14,390
12,670
1,619
18,440
18,220
19,790
19,880
1,774
11,790
1,439
14,390
12,670
1,619
11,480
11,330
12,270
10,940
1,100
10,490
1,013
10,120
9,790
1,205
12,040
L80
12,040
11,480
11,330
12,270
12,610
1,100
10,490
997
9,960
9,790
1,160
L80 1Cr
12,040
11,480
11,330
12,270
12,610
1,100
10,490
997
9,960
9,790
1,160
L80 HC
13,170
11,480
11,330
12,270
12,610
1,100
10,490
997
9,960
9,790
1,160
L80 IRP
12,040
11,480
11,330
12,270
12,610
1,100
10,490
997
9,960
9,790
1,160
L80 HCE
13,170
12,550
12,390
13,420
12,610
1,203
10,490
997
9,960
9,790
1,160
C90
13,540
12,910
12,740
13,810
14,690
1,237
11,790
1,100
10,990
11,010
1,239
14,300
13,630
13,450
14,570
14,020
1,306
11,790
1,159
11,590
11,620
1,301
13,630
13,450
14,570
15,520
1,306
11,790
1,159
11,590
11,620
1,301
T95 HC
15,050
13,630
13,450
14,570
15,520
1,306
11,790
1,159
11,590
11,620
1,301
T95 E
14,300
14,340
14,160
15,340
15,520
1,374
11,790
1,159
11,590
11,620
1,301
T95 HCE
15,050
14,340
14,160
15,340
15,520
1,374
11,790
1,159
11,590
11,620
1,301
P110
16,550
15,780
15,570
16,880
18,600
1,512
11,790
1,353
13,520
12,670
1,545
P110 MS
16,550
15,780
15,570
16,880
18,600
1,512
11,790
1,353
13,520
12,670
1,545
P110 EC
18,700
17,930
17,700
19,180
20,080
1,718
11,790
1,353
13,520
12,670
1,545
7 5/8 51.20
IP
(psi)
T95
0.625 13.744 6.250
IP
BC
JT
Opt.
Strength Torque
15,020
C95/R95 14,300
46.77
8rd LC
JT
Strength
(psi)
N80
7 5/8 47.10
8rd STC
15,440
P110
7 5/8 45.30
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
17,930
17,700
19,180
20,080
1,718
11,790
1,353
13,520
12,670
1,545
C110
16,550
15,780
15,570
16,880
17,110
1,512
11,790
1,317
13,160
12,670
1,425
Q125
18,700
17,930
17,700
19,180
20,080
1,718
11,790
1,515
15,150
12,670
1,673
Q125 HC
19,900
17,930
17,700
19,180
20,080
1,718
11,790
1,515
15,150
12,670
1,673
19,360
19,110
20,710
20,960
1,856
11,790
1,515
15,150
12,670
1,673
N80
13,120
12,610
12,420
13,390
12,090
1,198
L80
13,120
12,610
12,420
13,390
13,950
1,198
L80 1Cr
13,120
12,610
12,420
13,390
13,950
1,198
L80 HC
14,350
12,610
12,420
13,390
13,950
1,198
L80 IRP
13,120
12,610
12,420
13,390
13,950
1,198
L80 HCE
14,350
13,800
13,580
14,640
13,950
1,310
C90
14,760
14,190
13,970
15,060
16,270
1,348
C95/R95 15,580
14,980
14,740
15,900
15,510
1,423
58
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
50.95
N/A
Rev 05.2011
7 3/4 46.10
55.12
45.51
N/A
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
14,980
14,740
15,900
17,190
1,423
T95 HC
16,430
14,980
14,740
15,900
17,190
1,423
T95 E
15,580
15,770
15,520
16,730
17,190
1,497
T95 HCE
16,430
15,770
15,520
16,730
17,190
1,497
P110
18,040
17,340
17,070
18,410
20,590
1,647
P110 MS 18,040
17,340
17,070
18,410
20,590
1,647
P110 EC
19,710
19,400
20,920
22,240
1,872
20,500
7 5/8 55.30
8rd STC
15,580
T95
7 5/8 51.20
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
19,710
19,400
20,920
22,240
1,872
C110
18,040
17,340
17,070
18,410
18,940
1,647
Q125
20,500
19,710
19,400
20,920
22,240
1,872
Q125 HC
22,130
19,710
19,400
20,920
22,240
1,872
21,290
20,950
22,590
23,200
2,022
N80
14,190
13,770
13,510
14,500
13,270
1,296
L80
14,190
13,770
13,510
14,500
15,330
1,296
L80 1Cr
14,190
13,770
13,510
14,500
15,330
1,296
L80 HC
15,520
13,770
13,510
14,500
15,330
1,296
L80 IRP
14,190
13,770
13,510
14,500
15,330
1,296
L80 HCE
15,520
15,060
14,780
15,860
15,330
1,417
C90
15,960
15,490
15,200
16,310
17,890
1,458
C95/R95 16,850
16,350
16,050
17,220
17,050
1,539
T95
16,850
16,350
16,050
17,220
18,900
1,539
T95 HC
18,130
16,350
16,050
17,220
18,900
1,539
T95 E
16,850
17,210
16,890
18,130
18,900
1,620
T95 HCE
18,130
17,210
16,890
18,130
18,900
1,620
P110
19,510
18,930
18,580
19,940
22,640
1,782
P110 MS
19,510
18,930
18,580
19,940
22,640
1,782
P110 EC
22,170
21,520
21,110
22,660
24,450
2,025
21,520
21,110
22,660
24,450
2,025
C110
19,510
18,930
18,580
19,940
20,830
1,782
Q125
22,170
21,520
21,110
22,660
24,450
2,025
Q125 HC
23,950
21,520
21,110
22,660
24,450
2,025
23,240
22,800
24,470
25,520
2,187
N80
11,340
10,750
10,630
11,550
10,210
1,070
L80
11,340
10,750
10,630
11,550
11,760
1,070
L80 1Cr
11,340
10,750
10,630
11,550
11,760
1,070
L80 HC
12,400
10,750
10,630
11,550
11,760
1,070
59
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
7 3/4 46.10
Area
PE
(lb/ft)
45.51
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
N/A
IP
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
10,750
10,630
11,550
11,760
1,070
L80 HCE
12,400
11,760
11,620
12,630
11,760
1,170
C90
12,750
12,090
11,950
13,000
13,700
1,204
C95/R95
13,320
12,760
12,620
13,720
13,080
1,271
T95
13,320
12,760
12,620
13,720
14,470
1,271
T95 HC
13,900
12,760
12,620
13,720
14,470
1,271
T95 E
13,320
13,440
13,280
14,440
14,470
1,337
T95 HCE
13,900
13,440
13,280
14,440
14,470
1,337
P110
15,000
14,780
14,610
15,880
17,340
1,471
P110 MS 15,000
14,780
14,610
15,880
17,340
1,471
P110 EC
16,600
16,790
16,600
18,050
18,720
1,672
16,790
16,600
18,050
18,720
1,672
C110
15,000
14,780
14,610
15,880
15,950
1,471
Q125
16,600
16,790
16,600
18,050
18,720
1,672
Q125 HC
17,760
16,790
16,600
18,050
18,720
1,672
18,140
17,930
19,490
19,540
1,806
11,290
11,150
12,090
10,750
1,119
11,860
L80
11,860
11,290
11,150
12,090
12,390
1,119
L80 1Cr
11,860
11,290
11,150
12,090
12,390
1,119
L80 HC
12,970
11,290
11,150
12,090
12,390
1,119
L80 IRP
11,860
11,290
11,150
12,090
12,390
1,119
L80 HCE
12,970
12,350
12,190
13,220
12,390
1,224
C90
13,350
12,700
12,540
13,600
14,440
1,259
C95/R95 14,090
13,410
13,240
14,360
13,780
1,329
14,090
13,410
13,240
14,360
15,260
1,329
T95 HC
14,830
13,410
13,240
14,360
15,260
1,329
T95 E
14,090
14,110
13,940
15,110
15,260
1,399
T95 HCE
14,830
14,110
13,940
15,110
15,260
1,399
P110
16,310
15,520
15,330
16,620
18,270
1,539
P110 MS
16,310
15,520
15,330
16,620
18,270
1,539
P110 EC
18,160
17,640
17,420
18,890
19,740
1,749
17,640
17,420
18,890
19,740
1,749
16,310
15,520
15,330
16,620
16,810
1,539
Q125
18,160
17,640
17,420
18,890
19,740
1,749
Q125 HC
19,320
17,640
17,420
18,890
19,740
1,749
19,050
18,810
20,400
20,590
1,889
C110
IP
BC
JT
Opt.
Strength Torque
(psi)
T95
0.625 13.990 6.375
8rd LC
JT
Strength
11,340
N80
47.60
8rd STC
L80 IRP
7 3/4 47.60
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
60
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
31.13
(in)
0.352
(in2)
9.149
API
ALT.
(in)
(in)
7.796 7.875
8 5/8 36.00
8 5/8 40.00
35.17
39.33
N/A
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
J55
2,530
3,930
3,920
4,360
3,930
503
3,930
372
3,930
417
4,170
3,930
579
690
K55
2,530
3,930
3,920
4,360
4,980
503
3,930
402
3,930
452
4,520
3,930
N80
3,050
5,710
5,700
6,350
5,300
732
5,710
528
5,710
591
5,910
5,710
792
L80
3,050
5,710
5,700
6,350
6,080
732
5,710
521
5,710
583
5,820
5,710
764
L80 1Cr
3,050
5,710
5,700
6,350
6,080
732
5,710
521
5,710
583
5,820
5,710
764
L80 HC
3,180
5,710
5,700
6,350
6,080
732
5,710
521
5,710
583
5,820
5,710
764
L80 IRP
3,050
5,710
5,700
6,350
6,080
732
5,710
521
5,710
583
5,820
5,710
764
L80 HCE
3,180
6,250
6,230
6,940
6,080
801
6,250
521
6,250
583
5,820
6,250
764
C90
3,210
6,430
6,410
7,140
7,060
823
6,430
575
6,430
643
6,430
6,430
822
C95/R95
3,290
6,780
6,760
7,540
6,760
869
6,780
607
6,780
678
6,780
6,780
864
T95
3,290
6,780
6,760
7,540
7,460
869
6,780
607
6,780
678
6,780
6,780
864
T95 HC
4,120
6,780
6,760
7,540
7,460
869
6,780
607
6,780
678
6,780
6,780
864
T95 E
3,290
7,140
7,120
7,930
7,460
915
7,140
607
7,140
678
6,780
7,140
864
T95 HCE
4,120
7,140
7,120
7,930
7,460
915
7,140
607
7,140
678
6,780
7,140
864
J55
3,450
4,460
4,450
4,930
4,480
568
4,460
434
4,460
486
4,850
4,460
654
Rev 05.2011
8 5/8 32.00
Area
PE
(lb/ft)
Pipe Body
Drift
K55
3,450
4,460
4,450
4,930
5,680
568
4,460
468
4,460
526
5,260
4,460
780
N80
4,100
6,490
6,470
7,180
6,050
827
6,490
615
6,490
688
6,880
6,490
895
L80
4,100
6,490
6,470
7,180
6,940
827
6,490
606
6,490
678
6,780
6,490
864
L80 1Cr
4,100
6,490
6,470
7,180
6,940
827
6,490
606
6,490
678
6,780
6,490
864
L80 HC
4,220
6,490
6,470
7,180
6,940
827
6,490
606
6,490
678
6,780
6,490
864
L80 IRP
4,100
6,490
6,470
7,180
6,940
827
6,490
606
6,490
678
6,780
6,490
864
L80 HCE
4,220
7,100
7,070
7,850
6,940
904
7,100
606
7,100
678
6,780
7,100
864
C90
4,250
7,300
7,270
8,070
8,060
930
7,300
670
7,300
749
7,480
7,300
928
C95/R95
4,360
7,710
7,680
8,520
7,710
982
7,710
706
7,710
789
7,890
7,710
976
T95
4,360
7,710
7,680
8,520
8,520
982
7,710
706
7,710
789
7,890
7,710
976
T95 HC
5,780
7,710
7,680
8,520
8,520
982
7,710
706
7,710
789
7,890
7,710
976
T95 E
4,360
8,120
8,080
8,970
8,520
1,034
8,120
706
8,120
789
7,890
8,120
976
T95 HCE
5,780
8,120
8,080
8,970
8,520
1,034
8,120
706
8,120
789
7,890
8,120
976
1,001
N80
5,530
7,300
7,270
8,030
6,830
925
7,300
788
7,880
7,300
L80
5,530
7,300
7,270
8,030
7,840
925
7,300
776
7,760
7,300
966
L80 1Cr
5,530
7,300
7,270
8,030
7,840
925
7,300
776
7,760
7,300
966
L80 HC
5,790
7,300
7,270
8,030
7,840
925
7,300
776
7,760
7,300
966
L80 IRP
5,530
7,300
7,270
8,030
7,840
925
7,300
776
7,760
7,300
966
L80 HCE
5,790
7,990
7,950
8,780
7,840
1,011
7,990
776
7,760
7,990
966
C90
5,870
8,220
8,170
9,030
9,110
1,040
8,220
858
8,570
8,220
1,038
C95/R95
6,020
8,670
8,630
9,540
8,720
1,098
8,670
904
9,030
8,670
1,092
61
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
8 5/8 44.00
9 3/8 39.00
43.43
38.38
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
8,670
8,630
9,540
9,630
1,098
8,670
904
9,030
8,670
1,092
T95 HC
7,560
8,670
8,630
9,540
9,630
1,098
8,670
904
9,030
8,670
1,092
T95 E
6,020
9,130
9,080
10,040
9,630
1,156
9,130
904
9,030
9,130
1,092
T95 HCE
7,560
9,130
9,080
10,040
9,630
1,156
9,130
904
9,030
9,130
1,092
P110
39.33
8rd STC
6,020
T95
8 5/8 40.00
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
6,400
10,040
9,990
11,040
11,530
1,271
10,040
1,055
10,540
10,040
1,288
6,400
10,040
9,990
11,040
11,530
1,271
10,040
1,055
10,540
10,040
1,288
P110 EC
8,140
11,410
11,350
12,550
12,450
1,445
10,370
1,055
10,540
11,230
1,288
P110 HCE
8,380
11,410
11,350
12,550
12,450
1,445
10,370
1,055
10,540
11,230
1,288
Q125
6,640
11,410
11,350
12,550
12,450
1,445
10,370
1,182
11,820
11,230
1,415
N/A
Q125 HC
8,450
11,410
11,350
12,550
12,450
1,445
10,370
1,182
11,820
11,230
1,415
Q125 HCE
8,450
12,330
12,260
13,550
13,000
1,560
10,370
1,182
11,820
11,230
1,415
N80
6,950
8,120
8,060
8,880
7,620
1,021
8,120
887
8,860
8,120
1,105
L80
6,950
8,120
8,060
8,880
8,750
1,021
8,120
874
8,730
8,120
1,066
L80 1Cr
6,950
8,120
8,060
8,880
8,750
1,021
8,120
874
8,730
8,120
1,066
L80 HC
7,360
8,120
8,060
8,880
8,750
1,021
8,120
874
8,730
8,120
1,066
L80 IRP
6,950
8,120
8,060
8,880
8,750
1,021
8,120
874
8,730
8,120
1,066
L80 HCE
7,360
8,880
8,820
9,710
8,750
1,117
8,880
874
8,730
8,880
1,066
C90
7,490
9,130
9,070
9,980
10,180
1,149
9,130
965
9,640
9,130
1,146
C95/R95
7,740
9,640
9,570
10,540
9,730
1,212
9,640
1,017
10,160
9,640
1,206
T95
7,740
9,640
9,570
10,540
10,750
1,212
9,640
1,017
10,160
9,640
1,206
T95 HC
9,210
9,640
9,570
10,540
10,750
1,212
9,640
1,017
10,160
9,640
1,206
T95 E
7,740
10,140
10,080
11,090
10,750
1,276
10,140
1,017
10,160
10,140
1,206
T95 HCE
9,210
10,140
10,080
11,090
10,750
1,276
10,140
1,017
10,160
10,140
1,206
P110
8,420
11,160
11,090
12,200
12,880
1,404
10,370
1,186
11,860
11,160
1,423
P110 MS
8,420
11,160
11,090
12,200
12,880
1,404
10,370
1,186
11,860
11,160
1,423
P110 EC
8,980
12,680
12,600
13,870
13,910
1,595
10,370
1,186
11,860
11,230
1,423
P110 HCE
9,280
12,680
12,600
13,870
13,910
1,595
10,370
1,186
11,860
11,230
1,423
Q125
8,980
12,680
12,600
13,870
13,910
1,595
10,370
1,330
13,290
11,230
1,562
Q125 HC
9,280
12,680
12,600
13,870
13,910
1,595
10,370
1,330
13,290
11,230
1,562
Q125 HCE
9,280
13,700
13,610
14,980
14,510
1,723
10,370
1,330
13,290
11,230
1,562
P110
3,840
8,210
8,180
9,110
9,350
1,241
P110 MS
3,840
8,210
8,180
9,110
9,350
1,241
P110 EC
3,960
9,330
9,300
10,350
10,100
1,410
4,820
9,330
9,300
10,350
10,100
1,410
Q125
3,960
9,330
9,300
10,350
10,100
1,410
Q125 HC
4,860
9,330
9,300
10,350
10,100
1,410
Q125 HCE
4,860
10,080
10,040
11,180
10,540
1,523
62
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
9 5/8 36.00
34.89
38.97
(in)
(in2)
API
ALT.
(in)
(in)
9 5/8 43.50
42.73
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
J55
2,020
3,520
3,510
3,920
3,510
564
3,520
394
3,520
453
4,520
3,520
639
K55
2,020
3,520
3,510
3,920
4,450
564
3,520
423
3,520
489
4,880
3,520
755
N80
2,370
5,120
5,110
5,710
4,740
820
5,120
559
5,120
643
6,420
5,120
877
J55
2,570
3,950
3,940
4,390
3,950
630
3,950
452
3,950
520
5,190
3,950
714
843
K55
2,570
3,950
3,940
4,390
5,000
630
3,950
486
3,950
561
5,610
3,950
N80
3,090
5,750
5,730
6,380
5,330
916
5,750
642
5,750
737
7,370
5,750
979
L80
3,090
5,750
5,730
6,380
6,110
916
5,750
633
5,750
727
7,270
5,750
947
L80 1Cr
3,090
5,750
5,730
6,380
6,110
916
5,750
633
5,750
727
7,270
5,750
947
L80 HC
3,220
5,750
5,730
6,380
6,110
916
5,750
633
5,750
727
7,270
5,750
947
L80 IRP
3,090
5,750
5,730
6,380
6,110
916
5,750
633
5,750
727
7,270
5,750
947
L80 HCE
3,220
6,280
6,260
6,980
6,110
1,002
6,280
633
6,280
727
7,270
6,280
947
C90
3,260
6,460
6,440
7,180
7,100
1,031
6,460
700
6,460
804
8,030
6,460
1,021
C95/R95
3,330
6,820
6,800
7,580
6,800
1,088
6,820
738
6,820
847
8,470
6,820
1,074
T95
3,330
6,820
6,800
7,580
7,500
1,088
6,820
738
6,820
847
8,470
6,820
1,074
T95 HC
4,190
6,820
6,800
7,580
7,500
1,088
6,820
738
6,820
847
8,470
6,820
1,074
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
N/A
Rev 05.2011
9 5/8 40.00
Area
PE
(lb/ft)
Pipe Body
Drift
T95 E
3,330
7,180
7,160
7,980
7,500
1,145
7,180
738
7,180
847
8,470
7,180
1,074
T95 HCE
4,190
7,180
7,160
7,980
7,500
1,145
7,180
738
7,180
847
8,470
7,180
1,074
P110
3,470
7,900
7,870
8,770
8,980
1,260
7,900
861
7,900
988
9,880
7,900
1,266
P110 MS
3,470
7,900
7,870
8,770
8,980
1,260
7,900
861
7,900
988
9,880
7,900
1,266
P110 EC
3,530
8,980
8,950
9,970
9,700
1,432
8,980
861
8,980
988
9,880
8,980
1,266
P110 HCE
3,630
8,980
8,950
9,970
9,700
1,432
8,980
861
8,980
988
9,880
8,980
1,266
Q125
3,530
8,980
8,950
9,970
9,700
1,432
8,980
966
8,980
1,108
11,080
8,980
1,393
Q125 HC
3,630
8,980
8,950
9,970
9,700
1,432
8,980
966
8,980
1,108
11,080
8,980
1,393
Q125 HCE
3,630
9,700
9,660
10,770
10,130
1,546
9,670
966
9,700
1,108
11,080
9,160
1,393
N80
3,810
6,330
6,300
7,000
5,890
1,005
6,330
825
8,240
6,330
1,074
1,038
L80
3,810
6,330
6,300
7,000
6,750
1,005
6,330
813
8,130
6,330
L80 1Cr
3,810
6,330
6,300
7,000
6,750
1,005
6,330
813
8,130
6,330
1,038
L80 HC
3,950
6,330
6,300
7,000
6,750
1,005
6,330
813
8,130
6,330
1,038
L80 IRP
3,810
6,330
6,300
7,000
6,750
1,005
6,330
813
8,130
6,330
1,038
L80 HCE
3,950
6,920
6,890
7,660
6,750
1,099
6,920
813
8,130
6,920
1,038
C90
4,010
7,120
7,090
7,880
7,850
1,130
7,120
899
8,990
7,120
1,119
C95/R95
4,130
7,510
7,480
8,310
7,510
1,193
7,510
948
9,470
7,510
1,178
T95
4,130
7,510
7,480
8,310
8,290
1,193
7,510
948
9,470
7,510
1,178
T95 HC
5,410
7,510
7,480
8,310
8,290
1,193
7,510
948
9,470
7,510
1,178
T95 E
4,130
7,910
7,880
8,750
8,290
1,256
7,910
948
9,470
7,910
1,178
T95 HCE
5,410
7,910
7,880
8,750
8,290
1,256
7,910
948
9,470
7,910
1,178
63
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
9 5/8 43.50
9 5/8 47.00
9 5/8 53.50
Area
PE
(lb/ft)
42.73
46.18
52.90
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
P110
4,420
8,700
8,670
9,630
9,930
1,381
8,700
1,105
11,050
8,700
1,388
P110 MS
4,420
8,700
8,670
9,630
9,930
1,381
8,700
1,105
11,050
8,700
1,388
P110 EC
5,770
9,890
9,850
10,940
10,720
1,570
9,700
1,105
11,050
9,160
1,388
P110 HCE
5,940
9,890
9,850
10,940
10,720
1,570
9,700
1,105
11,050
9,160
1,388
C110
4,420
8,700
8,670
9,630
9,140
1,381
8,700
1,082
10,820
8,700
1,317
Q125
4,620
9,890
9,850
10,940
10,720
1,570
9,700
1,240
12,390
9,160
1,527
Q125 HC
5,940
9,890
9,850
10,940
10,720
1,570
9,700
1,240
12,390
9,160
1,527
Q125 HCE
5,940
10,680
10,640
11,810
11,190
1,695
9,700
1,240
12,390
9,160
1,527
N80
4,760
6,870
6,830
7,570
6,410
1,086
6,870
905
9,050
6,870
1,161
L80
4,760
6,870
6,830
7,570
7,350
1,086
6,870
893
8,920
6,870
1,122
L80 1Cr
4,760
6,870
6,830
7,570
7,350
1,086
6,870
893
8,920
6,870
1,122
L80 HC
4,940
6,870
6,830
7,570
7,350
1,086
6,870
893
8,920
6,870
1,122
1,122
L80 IRP
4,760
6,870
6,830
7,570
7,350
1,086
6,870
893
8,920
6,870
L80 HCE
4,940
7,510
7,470
8,280
7,350
1,188
7,510
893
8,920
7,510
1,122
C90
4,990
7,720
7,690
8,520
8,540
1,222
7,720
987
9,860
7,720
1,210
C95/R95
5,090
8,150
8,110
8,990
8,170
1,289
8,150
1,040
10,400
8,150
1,273
T95
5,090
8,150
8,110
8,990
9,020
1,289
8,150
1,040
10,400
8,150
1,273
T95 HC
6,600
8,150
8,110
8,990
9,020
1,289
8,150
1,040
10,400
8,150
1,273
T95 E
5,090
8,580
8,540
9,460
9,020
1,357
8,460
1,040
10,400
8,580
1,273
T95 HCE
6,600
8,580
8,540
9,460
9,020
1,357
8,460
1,040
10,400
8,580
1,273
P110
5,300
9,440
9,400
10,410
10,810
1,493
9,440
1,213
12,120
9,160
1,500
P110 MS
5,300
9,440
9,400
10,410
10,810
1,493
9,440
1,213
12,120
9,160
1,500
P110 EC
7,310
10,730
10,680
11,830
11,670
1,697
9,700
1,213
12,120
9,160
1,500
P110 HCE
7,530
10,730
10,680
11,830
11,670
1,697
9,700
1,213
12,120
9,160
1,500
C110
5,300
9,440
9,400
10,410
9,950
1,493
9,440
1,188
11,870
9,160
1,423
1,650
Q125
5,630
10,730
10,680
11,830
11,670
1,697
9,700
1,361
13,600
9,160
Q125 HC
7,530
10,730
10,680
11,830
11,670
1,697
9,700
1,361
13,600
9,160
1,650
Q125 HCE
7,530
11,590
11,530
12,770
12,180
1,832
9,700
1,361
13,600
9,160
1,650
N80
6,620
7,930
7,880
8,680
7,430
1,244
7,930
1,062
10,610
7,930
1,329
L80
6,620
7,930
7,880
8,680
8,540
1,244
7,930
1,047
10,460
7,930
1,285
L80 1Cr
6,620
7,930
7,880
8,680
8,540
1,244
7,930
1,047
10,460
7,930
1,285
L80 HC
7,000
7,930
7,880
8,680
8,540
1,244
7,930
1,047
10,460
7,930
1,285
L80 IRP
6,620
7,930
7,880
8,680
8,540
1,244
7,930
1,047
10,460
7,930
1,285
L80 HCE
7,000
8,670
8,620
9,490
8,540
1,360
8,460
1,047
10,460
8,670
1,285
C90
7,110
8,920
8,860
9,760
9,930
1,399
8,460
1,157
11,570
8,920
1,386
C95/R95
7,340
9,410
9,360
10,310
9,490
1,477
8,460
1,220
12,190
9,160
1,458
64
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
52.90
(in)
(in2)
API
ALT.
(in)
(in)
Rev 05.2011
9 5/8 53.50
Area
PE
(lb/ft)
Pipe Body
Drift
9 5/8 58.40
57.44
58.70
N/A
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
T95
7,340
9,410
9,360
10,310
10,490
1,477
8,460
1,220
12,190
9,160
1,458
T95 HC
8,850
9,410
9,360
10,310
10,490
1,477
8,460
1,220
12,190
9,160
1,458
T95 E
7,340
9,910
9,850
10,850
10,490
1,555
8,460
1,220
12,190
9,160
1,458
T95 HCE
8,850
9,910
9,850
10,850
10,490
1,555
8,460
1,220
12,190
9,160
1,458
P110
7,950
10,900
10,830
11,930
12,560
1,710
9,700
1,422
14,220
9,160
1,718
P110 MS
7,950
10,900
10,830
11,930
12,560
1,710
9,700
1,422
14,220
9,160
1,718
P110 EC
9,140
12,390
12,310
13,560
13,570
1,943
9,700
1,422
14,220
9,160
1,718
P110 HCE
9,390
12,390
12,310
13,560
13,570
1,943
9,700
1,422
14,220
9,160
1,718
C110
7,950
10,900
10,830
11,930
11,560
1,710
9,700
1,393
13,920
9,160
1,630
Q125
8,440
12,390
12,310
13,560
13,570
1,943
9,700
1,595
15,950
9,160
1,890
Q125 HC
9,700
12,390
12,310
13,560
13,570
1,943
9,700
1,595
15,950
9,160
1,890
Q125 HCE
9,700
13,380
13,290
14,650
14,160
2,099
9,700
1,595
15,950
9,160
1,890
N80
7,900
8,650
8,590
9,430
8,140
1,350
8,460
1,167
11,670
8,650
1,443
L80
7,900
8,650
8,590
9,430
9,360
1,350
8,460
1,151
11,500
8,650
1,396
L80 1Cr
7,900
8,650
8,590
9,430
9,360
1,350
8,460
1,151
11,500
8,650
1,396
L80 HC
8,400
8,650
8,590
9,430
9,360
1,350
8,460
1,151
11,500
8,650
1,396
L80 IRP
7,900
8,650
8,590
9,430
9,360
1,350
8,460
1,151
11,500
8,650
1,396
L80 HCE
8,400
9,470
9,400
10,320
9,360
1,477
8,460
1,151
11,500
8,830
1,396
C90
8,560
9,740
9,660
10,610
10,890
1,519
8,460
1,272
12,720
9,160
1,505
C95/R95
8,880
10,280
10,200
11,200
10,410
1,604
8,460
1,341
13,400
9,160
1,583
T95
8,880
10,280
10,200
11,200
11,500
1,604
8,460
1,341
13,400
9,160
1,583
T95 HC
10,210
10,280
10,200
11,200
11,500
1,604
8,460
1,341
13,400
9,160
1,583
T95 E
8,880
10,820
10,740
11,790
11,500
1,688
8,460
1,341
13,400
9,160
1,583
T95 HCE
10,210
10,820
10,740
11,790
11,500
1,688
8,460
1,341
13,400
9,160
1,583
P110
9,770
11,900
11,810
12,970
13,780
1,857
9,700
1,564
15,630
9,160
1,865
1,865
P110 MS
9,770
11,900
11,810
12,970
13,780
1,857
9,700
1,564
15,630
9,160
P110 EC
10,540
13,520
13,420
14,740
14,880
2,110
9,700
1,564
15,630
9,160
1,865
13,520
13,420
14,740
14,880
2,110
9,700
1,564
15,630
9,160
1,865
C110
9,770
11,900
11,810
12,970
12,680
1,857
9,700
1,531
15,310
9,160
1,770
Q125
10,540
13,520
13,420
14,740
14,880
2,110
9,700
1,754
17,540
9,160
2,052
Q125 HC
10,980
13,520
13,420
14,740
14,880
2,110
9,700
1,754
17,540
9,160
2,052
14,600
14,500
15,910
15,530
2,279
9,700
1,754
17,540
9,160
2,052
8,860
8,790
9,640
8,340
1,380
N80
9 5/8 59.40
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8,250
L80
8,250
8,860
8,790
9,640
9,590
1,380
L80 1Cr
8,250
8,860
8,790
9,640
9,590
1,380
L80 HC
8,800
8,860
8,790
9,640
9,590
1,380
65
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
9 5/8 59.40
9 7/8 62.80
Area
PE
(lb/ft)
58.70
61.80
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
N/A
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
L80 IRP
8,250
8,860
8,790
9,640
9,590
1,380
L80 HCE
8,800
9,690
9,610
10,540
9,590
1,509
C90
8,970
9,970
9,890
10,850
11,160
1,552
C95/R95
9,320
10,520
10,440
11,450
10,660
1,639
T95
9,320
10,520
10,440
11,450
11,790
1,639
T95 HC
10,570
10,520
10,440
11,450
11,790
1,639
T95 E
9,320
11,070
10,990
12,050
11,790
1,725
T95 HCE
10,570
11,070
10,990
12,050
11,790
1,725
P110
10,280
12,180
12,090
13,260
14,120
1,897
P110 MS 10,280
12,180
12,090
13,260
14,120
1,897
P110 EC
11,130
13,840
13,730
15,060
15,250
2,156
13,840
13,730
15,060
15,250
2,156
C110
10,280
12,180
12,090
13,260
12,990
1,897
Q125
11,130
13,840
13,730
15,060
15,250
2,156
Q125 HC
11,630
13,840
13,730
15,060
15,250
2,156
14,950
14,830
16,270
15,910
2,329
N80
8,260
8,860
8,790
9,640
8,340
1,453
L80
8,260
8,860
8,790
9,640
9,590
1,453
L80 1Cr
8,260
8,860
8,790
9,640
9,590
1,453
L80 HC
8,800
8,860
8,790
9,640
9,590
1,453
L80 IRP
8,260
8,860
8,790
9,640
9,590
1,453
L80 HCE
8,800
9,690
9,620
10,550
9,590
1,589
C90
8,980
9,970
9,890
10,850
11,160
1,635
C95/R95
9,320
10,520
10,440
11,450
10,670
1,725
T95
9,320
10,520
10,440
11,450
11,790
1,725
T95 HC
10,570
10,520
10,440
11,450
11,790
1,725
T95 E
9,320
11,080
10,990
12,050
11,790
1,816
T95 HCE
10,570
11,080
10,990
12,050
11,790
1,816
P110
10,290
12,180
12,090
13,260
14,120
1,998
P110 MS 10,290
12,180
12,090
13,260
14,120
1,998
P110 EC
11,250
13,840
13,740
15,070
15,250
2,270
13,840
13,740
15,070
15,250
2,270
10,290
12,180
12,090
13,260
12,990
1,998
Q125
11,140
13,840
13,740
15,070
15,250
2,270
Q125 HC
11,640
13,840
13,740
15,070
15,250
2,270
14,950
14,840
16,270
15,920
2,452
C110
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
66
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
64.10
(in)
(in2)
API
ALT.
(in)
(in)
Rev 05.2011
9 7/8 65.30
Area
PE
(lb/ft)
Pipe Body
Drift
68.66
N/A
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
N80
8,880
9,220
9,140
10,010
8,690
1,507
L80
8,880
9,220
9,140
10,010
10,000
1,507
L80 1Cr
8,880
9,220
9,140
10,010
10,000
1,507
L80 HC
9,490
9,220
9,140
10,010
10,000
1,507
L80 IRP
8,880
9,220
9,140
10,010
10,000
1,507
L80 HCE
9,490
10,080
9,990
10,940
10,000
1,648
C90
9,680
10,370
10,280
11,260
11,630
1,695
C95/R95
10,070
10,940
10,850
11,880
11,120
1,790
T95
10,070
10,940
10,850
11,880
12,290
1,790
T95 HC
12,040
10,940
10,850
11,880
12,290
1,790
T95 E
10,070
11,520
11,420
12,510
12,290
1,884
T95 HCE
12,040
11,520
11,420
12,510
12,290
1,884
P110
11,170
12,670
12,560
13,760
14,720
2,072
P110 MS
11,170
12,670
12,560
13,760
14,720
2,072
P110 EC
12,160
14,400
14,280
15,630
15,900
2,355
14,400
14,280
15,630
15,900
2,355
11,170
12,670
12,560
13,760
13,540
2,072
Q125
12,160
14,400
14,280
15,630
15,900
2,355
Q125 HC
12,760
14,400
14,280
15,630
15,900
2,355
15,550
15,420
16,880
16,590
2,543
C110
9 7/8 68.90
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
N80
10,120
9,920
9,830
10,720
9,390
1,614
L80
10,120
9,920
9,830
10,720
10,810
1,614
L80 1Cr
10,120
9,920
9,830
10,720
10,810
1,614
L80 HC
10,860
9,920
9,830
10,720
10,810
1,614
L80 IRP
10,120
9,920
9,830
10,720
10,810
1,614
L80 HCE
10,860
10,850
10,750
11,730
10,810
1,765
C90
11,100
11,160
11,060
12,060
12,580
1,816
C95/R95
11,580
11,780
11,670
12,740
12,020
1,917
T95
11,580
11,780
11,670
12,740
13,300
1,917
T95 HC
12,340
11,780
11,670
12,740
13,300
1,917
T95 E
11,580
12,410
12,280
13,410
13,300
2,018
T95 HCE
12,340
12,410
12,280
13,410
13,300
2,018
P110
12,940
13,650
13,510
14,750
15,930
2,219
P110 MS 12,940
13,650
13,510
14,750
15,930
2,219
P110 EC
14,210
15,510
15,360
16,760
17,200
2,522
15,510
15,360
16,760
17,200
2,522
67
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
10 1/8 79.29
10 3/4 40.50
10 3/4 45.50
68.66
79.29
38.91
44.26
N/A
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
12,940
13,650
13,510
14,750
14,650
2,219
Q125
14,210
15,510
15,360
16,760
17,200
2,522
Q125 HC
15,000
15,510
15,360
16,760
17,200
2,522
16,750
16,580
18,100
17,950
2,724
C110
9 7/8 68.90
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
P110
15,610
15,110
14,930
16,220
17,760
2,563
P110 MS
15,610
15,110
14,930
16,220
17,760
2,563
P110 EC
17,300
17,180
16,970
18,430
19,180
2,913
17,180
16,970
18,430
19,180
2,913
15,110
14,930
16,220
16,340
2,563
15,610
Q125
17,300
17,180
16,970
18,430
19,180
2,913
Q125 HC
18,370
17,180
16,970
18,430
19,180
2,913
18,550
18,330
19,900
20,010
3,146
700
J55
1,580
3,130
3,130
3,510
3,120
629
3,130
420
3,130
K55
1,580
3,130
3,130
3,510
3,950
629
3,130
450
3,130
819
J55
2,090
3,580
3,570
3,990
3,570
715
3,580
493
3,580
796
K55
2,090
3,580
3,570
3,990
4,530
715
3,580
528
3,580
931
N80
2,480
5,210
5,200
5,810
4,820
1,040
5,210
701
5,210
1,097
1,063
L80
2,480
5,210
5,200
5,810
5,530
1,040
5,210
692
5,210
L80 1Cr
2,480
5,210
5,200
5,810
5,530
1,040
5,210
692
5,210
1,063
L80 HC
3,140
5,210
5,200
5,810
5,530
1,040
5,210
692
5,210
1,063
L80 IRP
2,480
5,210
5,200
5,810
5,530
1,040
5,210
692
5,210
1,063
L80 HCE
3,140
5,700
5,680
6,350
5,530
1,138
5,700
692
5,700
1,063
C90
2,560
5,860
5,840
6,530
6,420
1,171
5,860
767
5,860
1,149
C95/R95
2,590
6,190
6,170
6,890
6,140
1,236
6,190
808
6,190
1,209
T95
2,590
6,190
6,170
6,890
6,780
1,236
6,190
808
6,190
1,209
T95 HC
3,180
6,190
6,170
6,890
6,780
1,236
6,190
808
6,190
1,209
T95 E
2,590
6,510
6,490
7,260
6,780
1,301
6,510
808
6,510
1,209
T95 HCE
3,180
6,510
6,490
7,260
6,780
1,301
6,510
808
6,510
1,209
P110
2,610
7,160
7,140
7,980
8,120
1,431
7,160
941
7,160
1,423
P110 MS
2,610
7,160
7,140
7,980
8,120
1,431
7,160
941
7,160
1,423
P110 EC
3,450
8,140
8,120
9,070
8,770
1,626
7,890
941
7,440
1,423
P110 HCE
3,450
8,140
8,120
9,070
8,770
1,626
7,890
941
7,440
1,423
Q125
2,610
8,140
8,120
9,070
8,770
1,626
7,890
1,057
7,440
1,570
Q125 HC
3,260
8,140
8,120
9,070
8,770
1,626
7,890
1,057
7,440
1,570
Q125 HCE
3,260
8,790
8,770
9,800
9,150
1,756
7,890
1,057
7,440
1,570
68
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
J55
49.55
Rev 05.2011
10 3/4 51.00
10 3/4 55.50
54.26
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
2,700
4,030
4,020
4,470
4,030
801
4,030
565
4,030
891
K55
2,700
4,030
4,020
4,470
5,110
801
4,030
606
4,030
1,043
N80
3,220
5,860
5,840
6,500
5,440
1,165
5,860
804
5,860
1,228
L80
3,220
5,860
5,840
6,500
6,240
1,165
5,860
794
5,860
1,190
L80 1Cr
3,220
5,860
5,840
6,500
6,240
1,165
5,860
794
5,860
1,190
L80 HC
3,360
5,860
5,840
6,500
6,240
1,165
5,860
794
5,860
1,190
L80 IRP
3,220
5,860
5,840
6,500
6,240
1,165
5,860
794
5,860
1,190
L80 HCE
3,360
6,410
6,390
7,110
6,240
1,274
6,410
794
6,410
1,190
C90
3,400
6,590
6,570
7,320
7,250
1,311
6,590
879
6,590
1,287
C95/R95
3,490
6,960
6,940
7,720
6,940
1,383
6,870
927
6,960
1,354
T95
3,490
6,960
6,940
7,720
7,660
1,383
6,870
927
6,960
1,354
T95 HC
4,420
6,960
6,940
7,720
7,660
1,383
6,870
927
6,960
1,354
N/A
T95 E
3,490
7,330
7,300
8,130
7,660
1,456
6,870
927
7,330
1,354
T95 HCE
4,420
7,330
7,300
8,130
7,660
1,456
6,870
927
7,330
1,354
P110
3,660
8,060
8,030
8,940
9,170
1,602
7,890
1,079
7,440
1,594
P110 MS
3,660
8,060
8,030
8,940
9,170
1,602
7,890
1,079
7,440
1,594
P110 EC
4,510
9,160
9,130
10,160
9,900
1,820
7,890
1,079
7,440
1,594
P110 HCE
4,510
9,160
9,130
10,160
9,900
1,820
7,890
1,079
7,440
1,594
Q125
3,740
9,160
9,130
10,160
9,900
1,820
7,890
1,212
7,440
1,758
Q125 HC
4,600
9,160
9,130
10,160
9,900
1,820
7,890
1,212
7,440
1,758
Q125 HCE
4,600
9,890
9,860
10,970
10,340
1,966
7,890
1,212
7,440
1,758
N80
4,020
6,450
6,420
7,130
6,000
1,276
6,450
895
6,450
1,345
L80
4,020
6,450
6,420
7,130
6,880
1,276
6,450
884
6,450
1,303
L80 1Cr
4,020
6,450
6,420
7,130
6,880
1,276
6,450
884
6,450
1,303
L80 HC
4,130
6,450
6,420
7,130
6,880
1,276
6,450
884
6,450
1,303
1,303
L80 IRP
4,020
6,450
6,420
7,130
6,880
1,276
6,450
884
6,450
L80 HCE
4,130
7,050
7,020
7,800
6,880
1,395
6,870
884
7,050
1,303
C90
4,160
7,250
7,220
8,020
8,000
1,435
6,870
979
7,250
1,409
4,300
7,660
7,620
8,460
7,660
1,515
6,870
1,032
7,440
1,483
T95
4,300
7,660
7,620
8,460
8,450
1,515
6,870
1,032
7,440
1,483
T95 HC
5,670
7,660
7,620
8,460
8,450
1,515
6,870
1,032
7,440
1,483
T95 E
4,300
8,060
8,030
8,910
8,450
1,595
6,870
1,032
7,440
1,483
T95 HCE
5,670
8,060
8,030
8,910
8,450
1,595
6,870
1,032
7,440
1,483
P110
4,610
8,860
8,830
9,800
10,120
1,754
7,890
1,202
7,440
1,745
P110 MS
4,610
8,860
8,830
9,800
10,120
1,754
7,890
1,202
7,440
1,745
P110 EC
6,130
10,070
10,030
11,140
10,930
1,993
7,890
1,202
7,440
1,745
69
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
P110 HCE
10 3/4 55.50
10 3/4 60.70
10 3/4 65.70
54.26
59.45
64.59
N/A
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
6,310
10,070
10,030
11,140
10,930
1,993
7,890
1,202
7,440
1,745
1,662
C110
4,610
8,860
8,830
9,800
9,310
1,754
7,890
1,180
7,440
Q125
4,850
10,070
10,030
11,140
10,930
1,993
7,890
1,350
7,440
1,925
Q125 HC
6,440
10,070
10,030
11,140
10,930
1,993
7,890
1,350
7,440
1,925
Q125 HCE
6,440
10,880
10,830
12,030
11,410
2,153
7,890
1,350
7,440
1,925
N80
5,160
7,100
7,060
7,810
6,630
1,398
6,870
996
7,100
1,473
L80
5,160
7,100
7,060
7,810
7,610
1,398
6,870
983
7,100
1,428
L80 1Cr
5,160
7,100
7,060
7,810
7,610
1,398
6,870
983
7,100
1,428
L80 HC
5,390
7,100
7,060
7,810
7,610
1,398
6,870
983
7,100
1,428
1,428
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
L80 IRP
5,160
7,100
7,060
7,810
7,610
1,398
6,870
983
7,100
L80 HCE
5,390
7,760
7,720
8,550
7,610
1,529
6,870
983
7,440
1,428
C90
5,460
7,980
7,950
8,790
8,840
1,573
6,870
1,089
7,440
1,544
C95/R95
5,580
8,430
8,390
9,280
8,460
1,660
6,870
1,148
7,440
1,625
T95
5,580
8,430
8,390
9,280
9,340
1,660
6,870
1,148
7,440
1,625
T95 HC
7,110
8,430
8,390
9,280
9,340
1,660
6,870
1,148
7,440
1,625
T95 E
5,580
8,870
8,830
9,770
9,340
1,747
6,870
1,148
7,440
1,625
T95 HCE
7,110
8,870
8,830
9,770
9,340
1,747
6,870
1,148
7,440
1,625
P110
5,880
9,760
9,710
10,740
11,190
1,922
7,890
1,337
7,440
1,912
P110 MS
5,880
9,760
9,710
10,740
11,190
1,922
7,890
1,337
7,440
1,912
P110 EC
7,780
11,090
11,030
12,210
12,090
2,184
7,890
1,337
7,440
1,912
P110 HCE
8,010
11,090
11,030
12,210
12,090
2,184
7,890
1,337
7,440
1,912
C110
5,880
9,760
9,710
10,740
10,300
1,922
7,890
1,312
7,440
1,821
Q125
6,070
11,090
11,030
12,210
12,090
2,184
7,890
1,502
7,440
2,109
Q125 HC
8,010
11,090
11,030
12,210
12,090
2,184
7,890
1,502
7,440
2,109
Q125 HCE
8,010
11,980
11,920
13,190
12,610
2,359
7,890
1,502
7,440
2,109
N80
6,310
7,750
7,700
8,490
7,260
1,519
6,870
1,096
7,440
1,600
L80
6,310
7,750
7,700
8,490
8,340
1,519
6,870
1,082
7,440
1,551
L80 1Cr
6,310
7,750
7,700
8,490
8,340
1,519
6,870
1,082
7,440
1,551
L80 HC
6,650
7,750
7,700
8,490
8,340
1,519
6,870
1,082
7,440
1,551
L80 IRP
6,310
7,750
7,700
8,490
8,340
1,519
6,870
1,082
7,440
1,551
6,650
8,480
8,430
9,290
8,340
1,661
6,870
1,082
7,440
1,551
C90
6,760
8,720
8,670
9,560
9,690
1,708
6,870
1,198
7,440
1,677
C95/R95
6,960
9,200
9,150
10,090
9,270
1,803
6,870
1,263
7,440
1,765
T95
6,960
9,200
9,150
10,090
10,240
1,803
6,870
1,263
7,440
1,765
T95 HC
8,490
9,200
9,150
10,090
10,240
1,803
6,870
1,263
7,440
1,765
T95 E
6,960
9,690
9,630
10,620
10,240
1,898
6,870
1,263
7,440
1,765
70
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
T95 HCE
64.59
10 3/4 68.80
10 3/4 73.20
68.76
72.40
N/A
N/A
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
8,490
9,690
9,630
10,620
10,240
1,898
6,870
1,263
7,440
1,765
P110
7,510
10,650
10,590
11,680
12,270
2,088
7,890
1,471
7,440
2,077
P110 MS
7,510
10,650
10,590
11,680
12,270
2,088
7,890
1,471
7,440
2,077
P110 EC
8,900
12,110
12,040
13,270
13,250
2,373
7,890
1,471
7,440
2,077
2,077
Rev 05.2011
10 3/4 65.70
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
9,170
12,110
12,040
13,270
13,250
2,373
7,890
1,471
7,440
C110
7,510
10,650
10,590
11,680
11,290
2,088
7,890
1,444
7,440
1,979
Q125
7,920
12,110
12,040
13,270
13,250
2,373
7,890
1,652
7,440
2,291
Q125 HC
9,170
12,110
12,040
13,270
13,250
2,373
7,890
1,652
7,440
2,291
Q125 HCE
9,170
13,080
13,000
14,330
13,820
2,563
7,890
1,652
7,440
2,291
N80
7,240
8,280
8,230
9,050
7,780
1,617
L80
7,240
8,280
8,230
9,050
8,940
1,617
L80 1Cr
7,240
8,280
8,230
9,050
8,940
1,617
L80 HC
7,680
8,280
8,230
9,050
8,940
1,617
L80 IRP
7,240
8,280
8,230
9,050
8,940
1,617
L80 HCE
7,680
9,060
9,000
9,900
8,940
1,768
C90
7,820
9,320
9,250
10,180
10,400
1,819
C95/R95
8,100
9,840
9,770
10,740
9,940
1,920
T95
8,100
9,840
9,770
10,740
10,980
1,920
T95 HC
9,870
9,840
9,770
10,740
10,980
1,920
T95 E
8,100
10,350
10,280
11,310
10,980
2,021
T95 HCE
9,870
10,350
10,280
11,310
10,980
2,021
P110
8,840
11,390
11,310
12,440
13,160
2,223
P110 MS
8,840
11,390
11,310
12,440
13,160
2,223
P110 EC
9,470
12,940
12,850
14,140
14,210
2,526
P110 HCE
9,810
12,940
12,850
14,140
14,210
2,526
C110
8,840
11,390
11,310
12,440
12,100
2,223
Q125
9,470
12,940
12,850
14,140
14,210
2,526
Q125 HC
9,810
12,940
12,850
14,140
14,210
2,526
Q125 HCE
9,810
13,980
13,880
15,270
14,830
2,728
N80
8,070
8,750
8,690
9,530
8,240
1,702
L80
8,070
8,750
8,690
9,530
9,470
1,702
L80 1Cr
8,070
8,750
8,690
9,530
9,470
1,702
L80 HC
8,590
8,750
8,690
9,530
9,470
1,702
L80 IRP
8,070
8,750
8,690
9,530
9,470
1,702
L80 HCE
8,590
9,570
9,500
10,420
9,470
1,862
C90
8,760
9,850
9,770
10,720
11,020
1,915
71
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
C95/R95
10 3/4 73.20
72.40
10 3/4 85.30
78.59
84.80
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
9,090
10,390
10,310
11,320
10,530
2,021
T95
9,090
10,390
10,310
11,320
11,640
2,021
T95 HC
10,380
10,390
10,310
11,320
11,640
2,021
T95 E
9,090
10,940
10,860
11,910
11,640
2,128
T95 HCE
10,380
10,940
10,860
11,910
11,640
2,128
P110
10,010
12,030
11,940
13,100
13,940
2,340
N/A P110 MS
10,010
12,030
11,940
13,100
13,940
2,340
P110 EC
10,820
13,670
13,570
14,890
15,060
2,660
13,670
13,570
14,890
15,060
2,660
C110
10,010
12,030
11,940
13,100
12,830
2,340
Q125
10,820
13,670
13,570
14,890
15,060
2,660
Q125 HC
11,290
13,670
13,570
14,890
15,060
2,660
14,770
14,660
16,080
15,710
2,872
N80
9,480
9,560
9,470
10,350
9,030
1,848
L80
9,480
9,560
9,470
10,350
10,390
1,848
L80 1Cr
9,480
9,560
9,470
10,350
10,390
1,848
L80 HC
10,290
9,560
9,470
10,350
10,390
1,848
L80 IRP
9,480
9,560
9,470
10,350
10,390
1,848
L80 HCE
10,290
10,460
10,360
11,330
10,390
2,021
C90
10,370
10,750
10,660
11,650
12,090
2,079
C95/R95 10,800
10 3/4 79.20
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
N/A
11,350
11,250
12,300
11,550
2,194
T95
10,800
11,350
11,250
12,300
12,780
2,194
T95 HC
11,750
11,350
11,250
12,300
12,780
2,194
T95 E
10,800
11,950
11,840
12,940
12,780
2,310
T95 HCE
11,750
11,950
11,840
12,940
12,780
2,310
P110
12,030
13,140
13,020
14,240
15,300
2,541
P110 MS
12,030
13,140
13,020
14,240
15,300
2,541
P110 EC
13,160
14,940
14,800
16,180
16,530
2,887
14,940
14,800
16,180
16,530
2,887
C110
12,030
13,140
13,020
14,240
14,080
2,541
Q125
13,160
14,940
14,800
16,180
16,530
2,887
Q125 HC
13,840
14,940
14,800
16,180
16,530
2,887
16,130
15,990
17,470
17,250
3,118
N80
10,920
10,380
10,270
11,180
9,840
1,994
L80
10,920
10,380
10,270
11,180
11,330
1,994
L80 1Cr
10,920
10,380
10,270
11,180
11,330
1,994
N/A
72
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
84.80
11 3/4 60.00
52.62
58.87
IP
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
10,380
10,270
11,180
11,330
1,994
L80 IRP
10,920
10,380
10,270
11,180
11,330
1,994
L80 HCE
11,740
11,350
11,230
12,230
11,330
2,181
C90
12,010
11,680
11,550
12,580
13,200
2,243
12,330
12,190
13,280
12,600
2,367
T95
12,540
12,330
12,190
13,280
13,950
2,367
T95 HC
13,070
12,330
12,190
13,280
13,950
2,367
T95 E
12,540
12,970
12,840
13,980
13,950
2,492
13,070
12,970
12,840
13,980
13,950
2,492
Rev 05.2011
11 3/4 54.00
45.60
8rd LC
JT
Strength
11,740
P110
11 3/4 47.00
8rd STC
L80 HC
C95/R95 12,540
10 3/4 85.30
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
14,080
14,270
14,120
15,380
16,700
2,741
P110 MS 14,080
14,270
14,120
15,380
16,700
2,741
P110 EC
15,530
16,220
16,050
17,470
18,040
3,115
16,220
16,050
17,470
18,040
3,115
C110
14,080
14,270
14,120
15,380
15,370
2,741
Q125
15,530
16,220
16,050
17,470
18,040
3,115
Q125 HC 16,440
16,220
16,050
17,470
18,040
3,115
17,520
17,330
18,870
18,820
3,364
J55
1,510
3,070
3,070
3,440
3,050
737
3,070
477
3,070
807
K55
1,510
3,070
3,070
3,440
3,870
737
3,070
509
3,070
935
J55
2,070
3,560
3,550
3,970
3,560
850
3,560
568
3,560
931
K55
2,070
3,560
3,550
3,970
4,500
850
3,560
606
3,560
1,079
J55
2,660
4,010
3,990
4,450
4,010
951
4,010
649
4,010
1,042
K55
2,660
4,010
3,990
4,450
5,080
951
4,010
693
4,010
1,208
N80
3,180
5,830
5,810
6,470
5,410
1,384
5,810
924
5,830
1,440
L80
3,180
5,830
5,810
6,470
6,200
1,384
5,810
913
5,830
1,399
L80 1Cr
3,180
5,830
5,810
6,470
6,200
1,384
5,810
913
5,830
1,399
L80 HC
4,400
5,830
5,810
6,470
6,200
1,384
5,810
913
5,830
1,399
L80 IRP
3,180
5,830
5,810
6,470
6,200
1,384
5,810
913
5,830
1,399
1,399
4,400
6,370
6,350
7,070
6,200
1,514
5,810
913
6,300
C90
3,360
6,550
6,530
7,280
7,200
1,557
5,810
1,011
6,300
1,517
C95/R95
3,440
6,920
6,900
7,680
6,900
1,643
5,810
1,066
6,300
1,596
T95
3,440
6,920
6,900
7,680
7,610
1,643
5,810
1,066
6,300
1,596
T95 HC
4,350
6,920
6,900
7,680
7,610
1,643
5,810
1,066
6,300
1,596
T95 E
3,440
7,280
7,260
8,080
7,610
1,730
5,810
1,066
6,300
1,596
T95 HCE
4,350
7,280
7,260
8,080
7,610
1,730
5,810
1,066
6,300
1,596
P110
3,610
8,010
7,980
8,890
9,120
1,903
6,670
1,242
6,300
1,877
73
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
P110 MS
11 3/4 60.00
11 3/4 65.00
11 3/4 71.00
58.87
64.03
69.48
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
3,610
8,010
7,980
8,890
9,120
1,903
6,670
1,242
6,300
1,877
P110 EC
4,410
9,100
9,070
10,100
9,850
2,162
6,670
1,242
6,300
1,877
P110 HCE
4,490
9,100
9,070
10,100
9,850
2,162
6,670
1,242
6,300
1,877
Q125
3,680
9,100
9,070
10,100
9,850
2,162
6,670
1,395
6,300
2,074
Q125 HC
4,520
9,100
9,070
10,100
9,850
2,162
6,670
1,395
6,300
2,074
Q125 HCE
4,520
9,830
9,800
10,910
10,270
2,335
6,670
1,395
6,300
2,074
J55
3,290
4,370
4,360
4,840
4,390
1,035
K55
3,290
4,370
4,360
4,840
5,560
1,035
N80
3,870
6,360
6,340
7,040
5,920
1,505
L80
3,870
6,360
6,340
7,040
6,790
1,505
L80 1Cr
3,870
6,360
6,340
7,040
6,790
1,505
L80 HC
5,400
6,360
6,340
7,040
6,790
1,505
L80 IRP
3,870
6,360
6,340
7,040
6,790
1,505
L80 HCE
5,400
6,960
6,930
7,700
6,790
1,646
C90
4,060
7,160
7,130
7,920
7,890
1,693
C95/R95
4,180
7,560
7,530
8,360
7,550
1,788
T95
4,180
7,560
7,530
8,360
8,340
1,788
T95 HC
5,490
7,560
7,530
8,360
8,340
1,788
T95 E
4,280
7,950
7,920
8,800
8,340
1,882
T95 HCE
5,490
7,950
7,920
8,800
8,340
1,882
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
P110
4,480
8,750
8,710
9,680
9,990
2,070
P110 MS
4,480
8,750
8,710
9,680
9,990
2,070
P110 EC
5,770
9,940
9,900
11,000
10,790
2,352
P110 HCE
5,770
9,940
9,900
11,000
10,790
2,352
Q125
4,690
9,940
9,900
11,000
10,790
2,352
Q125 HC
5,810
9,940
9,900
11,000
10,790
2,352
Q125 HCE
5,810
10,740
10,690
11,880
11,250
2,540
J55
3,970
4,770
4,740
5,250
4,790
1,123
K55
3,970
4,770
4,740
5,250
6,070
1,123
N80
4,880
6,930
6,900
7,640
6,470
1,634
L80
4,880
6,930
6,900
7,640
7,430
1,634
L80 1Cr
4,880
6,930
6,900
7,640
7,430
1,634
L80 HC
6,290
6,930
6,900
7,640
7,430
1,634
L80 IRP
4,880
6,930
6,900
7,640
7,430
1,634
L80 HCE
6,290
7,580
7,550
8,360
7,430
1,787
C90
5,130
7,800
7,760
8,600
8,630
1,838
74
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
69.48
(in)
(in2)
API
ALT.
(in)
(in)
Rev 05.2011
11 3/4 71.00
Area
PE
(lb/ft)
Pipe Body
Drift
11 3/4 75.00
11 3/4 79.00
73.54
77.80
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
C95/R95
5,240
8,230
8,200
9,070
8,260
1,940
T95
5,240
8,230
8,200
9,070
9,120
1,940
T95 HC
6,760
8,230
8,200
9,070
9,120
1,940
T95 E
5,330
8,670
8,630
9,550
9,120
2,042
T95 HCE
6,760
8,670
8,630
9,550
9,120
2,042
P110
5,470
9,530
9,490
10,510
10,920
2,246
P110 EC
7,070
10,840
10,780
11,940
11,800
2,552
P110 HCE
7,250
10,840
10,780
11,940
11,800
2,552
C110
5,470
9,530
9,490
10,510
10,050
2,246
Q125
5,760
10,840
10,780
11,940
11,800
2,552
Q125 HC
7,370
10,840
10,780
11,940
11,800
2,552
Q125 HCE
7,370
11,700
11,650
12,900
12,310
2,757
J55
4,470
5,060
5,040
5,560
5,100
1,189
K55
4,470
5,060
5,040
5,560
6,460
1,189
N80
5,630
7,360
7,320
8,090
6,890
1,729
L80
5,630
7,360
7,320
8,090
7,900
1,729
L80 1Cr
5,630
7,360
7,320
8,090
7,900
1,729
L80 HC
7,040
7,360
7,320
8,090
7,900
1,729
L80 IRP
5,630
7,360
7,320
8,090
7,900
1,729
L80 HCE
7,040
8,050
8,010
8,850
7,900
1,891
C90
5,990
8,280
8,240
9,100
9,190
1,945
C95/R95
6,150
8,740
8,700
9,610
8,790
2,053
T95
6,150
8,740
8,700
9,610
9,710
2,053
T95 HC
7,690
8,740
8,700
9,610
9,710
2,053
T95 E
6,300
9,200
9,150
10,120
9,710
2,161
T95 HCE
7,690
9,200
9,150
10,120
9,710
2,161
P110
6,540
10,120
10,070
11,130
11,630
2,377
P110 EC
6,810
11,510
11,440
12,640
12,560
2,702
P110 HCE
8,430
11,510
11,440
12,640
12,560
2,702
C110
6,540
10,120
10,070
11,130
10,700
2,377
Q125
6,810
11,510
11,440
12,640
12,560
2,702
Q125 HC
8,630
11,510
11,440
12,640
12,560
2,702
Q125 HCE
8,630
12,430
12,360
13,660
13,110
2,918
J55
5,000
5,370
5,340
5,890
5,430
1,257
K55
5,000
5,370
5,340
5,890
6,870
1,257
N80
6,430
7,820
7,770
8,560
7,330
1,829
75
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
11 3/4 79.00
11 7/8 71.80
Area
PE
(lb/ft)
77.80
70.26
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
L80
6,430
7,820
7,770
8,560
8,410
1,829
L80 1Cr
6,430
7,820
7,770
8,560
8,410
1,829
L80 HC
7,780
7,820
7,770
8,560
8,410
1,829
L80 IRP
6,430
7,820
7,770
8,560
8,410
1,829
L80 HCE
7,780
8,550
8,500
9,370
8,410
2,001
C90
6,890
8,790
8,740
9,630
9,780
2,058
C95/R95
7,110
9,280
9,230
10,170
9,350
2,172
T95
7,110
9,280
9,230
10,170
10,330
2,172
T95 HC
8,620
9,280
9,230
10,170
10,330
2,172
T95 E
7,310
9,770
9,710
10,710
10,330
2,286
T95 HCE
8,620
9,770
9,710
10,710
10,330
2,286
P110
7,670
10,750
10,680
11,780
12,380
2,515
P110 EC
8,120
12,210
12,140
13,380
13,370
2,858
P110 HCE
9,690
12,210
12,140
13,380
13,370
2,858
C110
7,670
10,750
10,680
11,780
11,390
2,515
Q125
8,120
12,210
12,140
13,380
13,370
2,858
Q125 HC
9,990
12,210
12,140
13,380
13,370
2,858
Q125 HCE
9,990
13,190
13,110
14,450
13,950
3,087
J55
3,880
4,720
4,700
5,200
4,740
1,136
K55
3,880
4,720
4,700
5,200
6,010
1,136
N80
4,750
6,860
6,830
7,570
6,400
1,652
L80
4,750
6,860
6,830
7,570
7,340
1,652
L80 1Cr
4,750
6,860
6,830
7,570
7,340
1,652
L80 HC
6,160
6,860
6,830
7,570
7,340
1,652
L80 IRP
4,750
6,860
6,830
7,570
7,340
1,652
L80 HCE
6,160
7,500
7,470
8,270
7,340
1,807
C90
4,980
7,720
7,680
8,510
8,540
1,858
C95/R95
5,080
8,150
8,110
8,980
8,170
1,962
T95
5,080
8,150
8,110
8,980
9,020
1,962
T95 HC
6,590
8,150
8,110
8,980
9,020
1,962
T95 E
5,170
8,580
8,540
9,460
9,020
2,065
T95 HCE
6,590
8,580
8,540
9,460
9,020
2,065
P110
5,290
9,430
9,390
10,400
10,800
2,271
P110 EC
7,190
10,720
10,670
11,820
11,670
2,581
P110 HCE
7,190
10,720
10,670
11,820
11,670
2,581
C110
5,290
9,430
9,390
10,400
9,940
2,271
76
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
ALT.
(in)
(in)
13 3/8 54.50
Rev 05.2011
13 3/8 61.00
13 3/8 68.00
13 3/8 72.00
70.26
52.79
59.50
66.17
70.67
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
10,720
10,670
11,820
11,670
2,581
7,400
10,720
10,670
11,820
11,670
2,581
Q125 HCE
7,400
11,580
11,520
12,770
12,170
2,788
J55
1,130
2,730
2,730
3,070
2,710
853
2,730
514
2,730
909
Q125
11 7/8 71.80
8rd STC
5,630
(in)
(in2)
API
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
K55
1,130
2,730
2,730
3,070
3,440
853
2,730
547
2,730
1,038
J55
1,540
3,090
3,090
3,460
3,080
962
3,090
595
3,090
1,025
K55
1,540
3,090
3,090
3,460
3,900
962
3,090
633
3,090
1,170
J55
1,950
3,450
3,450
3,850
3,440
1,069
3,450
675
3,450
1,140
K55
1,950
3,450
3,450
3,850
4,360
1,069
3,450
718
3,450
1,300
N80
2,260
5,020
5,010
5,610
4,650
1,556
4,550
963
4,930
1,585
L80
2,260
5,020
5,010
5,610
5,320
1,556
4,550
952
4,930
1,545
L80 1Cr
2,260
5,020
5,010
5,610
5,320
1,556
4,550
952
4,930
1,545
L80 HC
2,820
5,020
5,010
5,610
5,320
1,556
4,550
952
4,930
1,545
L80 IRP
2,260
5,020
5,010
5,610
5,320
1,556
4,550
952
4,930
1,545
L80 HCE
2,820
5,500
5,480
6,130
5,320
1,701
4,550
952
4,930
1,545
C90
2,320
5,650
5,640
6,310
6,180
1,750
4,550
1,057
4,930
1,683
C95/R95
2,340
5,970
5,950
6,660
5,920
1,847
4,550
1,114
4,930
1,772
T95
2,340
5,970
5,950
6,660
6,530
1,847
4,550
1,114
4,930
1,772
T95 HC
2,870
5,970
5,950
6,660
6,530
1,847
4,550
1,114
4,930
1,772
T95 E
2,330
6,280
6,260
7,010
6,530
1,945
4,550
1,114
4,930
1,772
T95 HCE
2,870
6,280
6,260
7,010
6,530
1,945
4,550
1,114
4,930
1,772
P110
2,330
6,910
6,890
7,710
7,820
2,139
5,220
1,297
4,930
2,079
P110 EC
2,910
7,850
7,830
8,760
8,450
2,431
5,220
1,297
4,930
2,079
P110 HCE
2,910
7,850
7,830
8,760
8,450
2,431
5,220
1,297
4,930
2,079
Q125
2,330
7,850
7,830
8,760
8,450
2,431
5,220
1,458
4,930
2,306
Q125 HC
2,930
7,850
7,830
8,760
8,450
2,431
5,220
1,458
4,930
2,306
Q125 HCE
2,930
8,480
8,460
9,460
8,820
2,625
5,220
1,458
4,930
2,306
N80
2,670
5,380
5,360
5,990
4,990
1,661
4,550
1,040
4,930
1,693
L80
2,670
5,380
5,360
5,990
5,710
1,661
4,550
1,029
4,930
1,650
L80 1Cr
2,670
5,380
5,360
5,990
5,710
1,661
4,550
1,029
4,930
1,650
L80 HC
3,410
5,380
5,360
5,990
5,710
1,661
4,550
1,029
4,930
1,650
2,670
5,380
5,360
5,990
5,710
1,661
4,550
1,029
4,930
1,650
L80 HCE
3,410
5,880
5,870
6,550
5,710
1,817
4,550
1,029
4,930
1,650
C90
2,780
6,050
6,040
6,740
6,630
1,869
4,550
1,142
4,930
1,797
C95/R95
2,830
6,390
6,370
7,110
6,350
1,973
4,550
1,204
4,930
1,893
T95
2,830
6,390
6,370
7,110
7,010
1,973
4,550
1,204
4,930
1,893
77
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
13 3/8 72.00
13 3/8 77.00
13 5/8 88.20
Area
PE
(lb/ft)
70.67
75.40
86.86
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
T95 HC
3,490
6,390
6,370
7,110
7,010
1,973
4,550
1,204
4,930
1,893
1,893
T95 E
2,850
6,730
6,710
7,490
7,010
2,077
4,550
1,204
4,930
T95 HCE
3,490
6,730
6,710
7,490
7,010
2,077
4,550
1,204
4,930
1,893
P110
2,880
7,400
7,380
8,240
8,390
2,284
5,220
1,401
4,930
2,221
3,510
8,410
8,380
9,360
9,070
2,596
5,220
1,401
4,930
2,221
P110 HCE
3,560
8,410
8,380
9,360
9,070
2,596
5,220
1,401
4,930
2,221
Q125
2,880
8,410
8,380
9,360
9,070
2,596
5,220
1,576
4,930
2,463
Q125 HC
3,580
8,410
8,380
9,360
9,070
2,596
5,220
1,576
4,930
2,463
Q125 HCE
3,580
9,080
9,050
10,110
9,460
2,804
5,220
1,576
4,930
2,463
N80
3,100
5,760
5,740
6,390
5,340
1,773
L80
3,100
5,760
5,740
6,390
6,120
1,773
L80 1Cr
3,100
5,760
5,740
6,390
6,120
1,773
L80 HC
4,090
5,760
5,740
6,390
6,120
1,773
L80 IRP
3,100
5,760
5,740
6,390
6,120
1,773
L80 HCE
4,090
6,300
6,280
6,990
6,120
1,939
C90
3,270
6,480
6,460
7,190
7,110
1,994
C95/R95
3,350
6,840
6,810
7,590
6,810
2,105
T95
3,350
6,840
6,810
7,590
7,520
2,105
T95 HC
4,210
6,840
6,810
7,590
7,520
2,105
T95 E
3,400
7,200
7,170
7,990
7,520
2,216
T95 HCE
4,210
7,200
7,170
7,990
7,520
2,216
P110
3,490
7,920
7,890
8,790
9,000
2,438
P110 EC
4,240
9,000
8,970
9,990
9,720
2,770
P110 HCE
4,330
9,000
8,970
9,990
9,720
2,770
Q125
3,550
9,000
8,970
9,990
9,720
2,770
Q125 HC
4,370
9,000
8,970
9,990
9,720
2,770
Q125 HCE
4,370
9,710
9,680
10,790
10,150
2,992
N80
3,980
6,420
6,400
7,100
5,980
2,042
L80
3,980
6,420
6,400
7,100
6,860
2,042
L80 1Cr
3,980
6,420
6,400
7,100
6,860
2,042
L80 HC
5,340
6,420
6,400
7,100
6,860
2,042
3,980
6,420
6,400
7,100
6,860
2,042
L80 HCE
5,340
7,020
7,000
7,770
6,860
2,233
C90
4,130
7,220
7,200
7,990
7,970
2,297
C95/R95
4,260
7,630
7,600
8,430
7,630
2,425
T95
4,260
7,630
7,600
8,430
8,420
2,425
78
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
T95 HC
86.86
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
5,620
7,630
7,600
8,430
8,420
2,425
T95 E
4,370
8,030
7,990
8,880
8,420
2,553
T95 HCE
5,620
8,030
7,990
8,880
8,420
2,553
P110
4,570
8,830
8,790
9,760
10,080
2,808
P110 EC
5,950
10,030
9,990
11,100
10,890
3,191
P110 HCE
5,950
10,030
9,990
11,100
10,890
3,191
C110
4,570
8,830
8,790
9,760
9,280
2,808
Q125
4,800
10,030
9,990
11,100
10,890
3,191
Q125 HC
5,970
10,030
9,990
11,100
10,890
3,191
Q125 HCE
5,970
10,840
10,790
11,980
11,360
3,446
Rev 05.2011
13 5/8 88.20
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
79
80
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
14
94.80
80.73
93.58
(in)
(in2)
API
ALT.
(in)
(in)
14
14
99.30
97.91
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
K55
2,420
3,860
3,850
4,290
4,890
1,305
N80
2,940
5,620
5,600
6,250
5,210
1,898
L80
2,940
5,620
5,600
6,250
5,970
1,898
L80 HC
3,840
5,620
5,600
6,250
5,970
1,898
C95/R95
3,160
6,670
6,650
7,420
6,640
2,254
K55
3,530
4,510
4,490
4,980
5,740
1,513
N80
4,220
6,560
6,530
7,250
6,110
2,200
L80
4,220
6,560
6,530
7,250
7,010
2,200
L80 HC
5,600
6,560
6,530
7,250
7,010
2,200
C95/R95
4,450
7,790
7,760
8,610
7,800
2,613
P110
4,800
9,020
8,980
9,960
10,310
3,025
P110 HC
4,800
9,020
8,980
9,960
10,310
3,025
P110 EC
6,250
10,250
10,210
11,320
11,130
3,438
C110
4,800
9,020
8,980
9,960
9,490
3,025
Q125
5,060
10,250
10,210
11,320
11,130
3,438
Q125 HC
6,330
10,250
10,210
11,320
11,130
3,438
K55
3,900
4,730
4,710
5,210
6,020
1,583
N80
4,780
6,880
6,850
7,580
6,420
2,302
L80
4,780
6,880
6,850
7,580
7,370
2,302
L80 HC
6,200
6,880
6,850
7,580
7,370
2,302
C95/R95
5,120
8,170
8,130
9,010
8,190
2,733
P110
5,330
9,460
9,420
10,430
10,830
3,165
P110 HC
5,330
9,460
9,420
10,430
10,830
3,165
P110 EC
7,100
10,750
10,700
11,850
11,700
3,597
C110
5,330
9,460
9,420
10,430
9,970
3,165
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
Rev 05.2011
14
82.50
Area
PE
(lb/ft)
Pipe Body
Drift
Q125
5,660
10,750
10,700
11,850
11,700
3,597
Q125 HC
7,220
10,750
10,700
11,850
11,700
3,597
N80
5,340
7,200
7,160
7,920
6,730
2,403
L80
5,340
7,200
7,160
7,920
7,720
2,403
L80 HC
6,760
7,200
7,160
7,920
7,720
2,403
C95/R95
5,800
8,550
8,510
9,410
8,590
2,854
P110
6,130
9,900
9,850
10,890
11,360
3,304
P110 HC
6,130
9,900
9,850
10,890
11,360
3,304
P110 EC
7,980
11,250
11,190
12,380
12,270
3,755
C110
6,130
9,900
9,850
10,890
10,450
3,304
Q125
6,330
11,250
11,190
12,380
12,270
3,755
Q125 HC
8,140
11,250
11,190
12,380
12,270
3,755
81
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
14
14
14
16
16
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
65.00
75.00
62.64
72.86
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
N80
6,260
7,720
7,670
8,460
7,230
2,567
L80
6,260
7,720
7,670
8,460
8,300
2,567
L80 HC
7,630
7,720
7,670
8,460
8,300
2,567
C95/R95
6,900
9,170
9,110
10,050
9,230
3,048
P110
7,430
10,620
10,550
11,640
12,220
3,529
P110 HC
7,430
10,620
10,550
11,640
12,220
3,529
P110 EC
9,430
12,060
11,990
13,230
13,200
4,010
C110
7,430
10,620
10,550
11,640
11,240
3,529
Q125
7,840
12,060
11,990
13,230
13,200
4,010
Q125 HC
9,700
12,060
11,990
13,230
13,200
4,010
N80
6,750
8,000
7,950
8,760
7,500
2,654
L80
6,750
8,000
7,950
8,760
8,620
2,654
L80 HC
8,070
8,000
7,950
8,760
8,620
2,654
C95/R95
7,500
9,500
9,440
10,400
9,580
3,152
P110
8,130
11,000
10,930
12,040
12,680
3,649
P110 HC
8,130
11,000
10,930
12,040
12,680
3,649
P110 EC
10,200
12,500
12,420
13,680
13,700
4,147
C110
8,130
11,000
10,930
12,040
11,670
3,649
Q125
8,650
12,500
12,420
13,680
13,700
4,147
Q125 HC
10,540
12,500
12,420
13,680
13,700
4,147
N80
7,630
8,500
8,440
9,270
7,990
2,809
L80
7,630
8,500
8,440
9,270
9,180
2,809
L80 HC
8,070
8,500
8,440
9,270
9,180
2,809
C95/R95
8,560
10,090
10,020
11,010
10,210
3,336
P110
9,380
11,690
11,600
12,750
13,520
3,863
P110 HC
9,380
11,690
11,600
12,750
13,520
3,863
P110 EC
10,200
13,280
13,190
14,490
14,600
4,389
C110
9,380
11,690
11,600
12,750
12,440
3,863
Q125
10,090
13,280
13,190
14,490
14,600
4,389
Q125 HC
10,540
13,280
13,190
14,490
14,600
4,389
J55
630
2,260
2,250
2,550
2,230
1,012
2,260
591
2,260
1,031
K55
630
2,260
2,250
2,550
2,830
1,012
2,260
625
2,260
1,144
J55
1,010
2,630
2,630
2,960
2,610
1,178
2,630
710
2,630
1,200
K55
1,010
2,630
2,630
2,960
3,310
1,178
2,630
752
2,630
1,331
82
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
84.00
82.05
(in)
(in2)
API
ALT.
(in)
(in)
16
94.50
92.75
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
K55
1,400
2,980
2,970
3,340
3,750
1,326
2,980
865
2,980
1,499
N80
1,480
4,330
4,320
4,850
3,990
1,929
3,230
1,167
3,550
1,898
L80
1,480
4,330
4,320
4,850
4,570
1,929
3,230
1,156
3,550
1,861
L80 HC
1,840
4,330
4,320
4,850
4,570
1,929
3,230
1,156
3,550
1,861
C90
1,480
4,870
4,860
5,460
5,310
2,170
3,230
1,284
3,550
2,043
C90 HC
1,480
4,870
4,860
5,460
5,310
2,170
3,230
1,284
3,550
2,043
C95/R95
1,480
5,140
5,130
5,760
5,080
2,291
3,230
1,354
3,550
2,153
T95
1,480
5,140
5,130
5,760
5,610
2,291
3,230
1,354
3,550
2,153
T95 HC
1,860
5,140
5,130
5,760
5,610
2,291
3,230
1,354
3,550
2,153
2,518
P110
1,480
5,960
5,940
6,670
6,720
2,652
3,230
1,575
3,550
P110 HC
1,480
5,960
5,940
6,670
6,720
2,652
3,230
1,575
3,550
2,518
P110 EC
1,880
6,770
6,760
7,580
7,250
3,014
3,230
1,575
3,550
2,518
C110
1,480
5,960
5,940
6,670
6,180
2,652
3,230
1,552
3,550
2,444
Q125
1,480
6,770
6,760
7,580
7,250
3,014
3,230
1,773
3,550
2,809
Q125 HC
1,880
6,770
6,760
7,580
7,250
3,014
3,230
1,773
3,550
2,809
K55
1,860
3,380
3,370
3,770
4,270
1,499
N80
2,140
4,920
4,910
5,490
4,550
2,181
Rev 05.2011
16
Area
PE
(lb/ft)
Pipe Body
Drift
L80
2,140
4,920
4,910
5,490
5,210
2,181
L80 HC
2,650
4,920
4,910
5,490
5,210
2,181
C90
2,180
5,530
5,520
6,180
6,050
2,453
C90 HC
2,180
5,530
5,520
6,180
6,050
2,453
C95/R95
2,190
5,840
5,830
6,520
5,790
2,589
T95
2,190
5,840
5,830
6,520
6,390
2,589
T95 HC
2,690
5,840
5,830
6,520
6,390
2,589
P110
2,190
6,760
6,750
7,550
7,650
2,998
P110 HC
2,190
6,760
6,750
7,550
7,650
2,998
P110 EC
2,730
7,680
7,670
8,580
8,260
3,407
C110
2,190
6,760
6,750
7,550
7,040
2,998
Q125
2,190
7,680
7,670
8,580
8,260
3,407
Q125 HC
2,740
7,680
7,670
8,580
8,260
3,407
83
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
K55
16
16
97.00
94.81
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
1,950
3,460
3,450
3,860
4,370
1,533
N80
2,270
5,030
5,020
5,610
4,660
2,229
L80
2,270
5,030
5,020
5,610
5,330
2,229
L80 HC
2,650
5,030
5,020
5,610
5,330
2,229
C90
2,330
5,660
5,650
6,310
6,190
2,508
C90 HC
2,330
5,660
5,650
6,310
6,190
2,508
C95/R95
2,350
5,970
5,960
6,670
5,930
2,647
T95
2,350
5,970
5,960
6,670
6,540
2,647
T95 HC
2,690
5,970
5,960
6,670
6,540
2,647
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
P110
2,340
6,920
6,900
7,720
7,830
3,065
P110 HC
2,340
6,920
6,900
7,720
7,830
3,065
P110 EC
2,730
7,860
7,840
8,770
8,460
3,483
C110
2,340
6,920
6,900
7,720
7,210
3,065
Q125
2,340
7,860
7,840
8,770
8,460
3,483
Q125 HC
2,740
7,860
7,840
8,770
8,460
3,483
N80
3,080
5,740
5,720
6,370
5,330
2,530
L80
3,080
5,740
5,720
6,370
6,110
2,530
L80 HC
4,060
5,740
5,720
6,370
6,110
2,530
C90
3,250
6,460
6,440
7,170
7,090
2,846
C90 HC
3,250
6,460
6,440
7,170
7,090
2,846
C95/R95
3,320
6,820
6,790
7,570
6,790
3,004
T95
3,320
6,820
6,790
7,570
7,490
3,004
T95 HC
4,180
6,820
6,790
7,570
7,490
3,004
P110
3,470
7,890
7,870
8,770
8,980
3,478
P110 HC
3,470
7,890
7,870
8,770
8,980
3,478
P110 EC
4,300
8,970
8,940
9,960
9,690
3,953
C110
3,470
7,890
7,870
8,770
8,260
3,478
Q125
3,520
8,970
8,940
9,960
9,690
3,953
Q125 HC
4,330
8,970
8,940
9,960
9,690
3,953
84
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
(in)
(in2)
API
ALT.
(in)
(in)
Rev 05.2011
16
Area
PE
(lb/ft)
Pipe Body
Drift
16
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
N80
3,690
6,260
6,230
6,930
5,820
2,747
L80
3,690
6,260
6,230
6,930
6,670
2,747
L80 HC
5,030
6,260
6,230
6,930
6,670
2,747
C90
3,920
7,040
7,010
7,790
7,760
3,090
C90 HC
3,920
7,040
7,010
7,790
7,760
3,090
C95/R95
4,030
7,430
7,400
8,220
7,420
3,262
T95
4,030
7,430
7,400
8,220
8,190
3,262
T95 HC
5,260
7,430
7,400
8,220
8,190
3,262
P110
4,300
8,600
8,570
9,520
9,810
3,777
P110 HC
4,300
8,600
8,570
9,520
9,810
3,777
P110 EC
5,490
9,780
9,740
10,820
10,600
4,292
C110
4,300
8,600
8,570
9,520
9,030
3,777
Q125
4,490
9,780
9,740
10,820
10,600
4,292
Q125 HC
5,540
9,780
9,740
10,820
10,600
4,292
N80
4,700
6,830
6,800
7,540
6,380
2,987
L80
4,700
6,830
6,800
7,540
7,310
2,987
L80 HC
6,110
6,830
6,800
7,540
7,310
2,987
C90
4,930
7,690
7,650
8,480
8,500
3,361
C90 HC
4,930
7,690
7,650
8,480
8,500
3,361
C95/R95
5,020
8,120
8,080
8,950
8,130
3,547
T95
5,020
8,120
8,080
8,950
8,980
3,547
T95 HC
6,530
8,120
8,080
8,950
8,980
3,547
P110
5,240
9,400
9,350
10,360
10,760
4,108
P110 HC
5,240
9,400
9,350
10,360
10,760
4,108
P110 EC
6,980
10,680
10,630
11,780
11,620
4,668
C110
5,240
9,400
9,350
10,360
9,900
4,108
Q125
5,570
10,680
10,630
11,780
11,620
4,668
Q125 HC
7,090
10,680
10,630
11,780
11,620
4,668
85
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
16
16
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
18 5/8 87.50
84.59
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
N80
5,760
7,440
7,400
8,170
6,960
3,236
L80
5,760
7,440
7,400
8,170
7,990
3,236
L80 HC
7,170
7,440
7,400
8,170
7,990
3,236
C90
6,130
8,370
8,320
9,190
9,290
3,641
C90 HC
6,130
8,370
8,320
9,190
9,290
3,641
C95/R95
6,300
8,830
8,780
9,700
8,880
3,843
T95
6,300
8,830
8,780
9,700
9,810
3,843
T95 HC
7,840
8,830
8,780
9,700
9,810
3,843
P110
6,730
10,230
10,170
11,230
11,750
4,450
P110 HC
6,730
10,230
10,170
11,230
11,750
4,450
P110 EC
8,640
11,620
11,560
12,770
12,690
5,057
C110
6,730
10,230
10,170
11,230
10,810
4,450
Q125
7,020
11,620
11,560
12,770
12,690
5,057
Q125 HC
8,850
11,620
11,560
12,770
12,690
5,057
N80
6,620
7,930
7,880
8,680
7,430
3,437
L80
6,620
7,930
7,880
8,680
8,540
3,437
L80 HC
7,960
7,930
7,880
8,680
8,540
3,437
C90
7,110
8,920
8,860
9,770
9,930
3,867
C90 HC
7,110
8,920
8,860
9,770
9,930
3,867
C95/R95
7,340
9,410
9,360
10,310
9,490
4,081
T95
7,340
9,410
9,360
10,310
10,490
4,081
T95 HC
8,850
9,410
9,360
10,310
10,490
4,081
P110
7,950
10,900
10,830
11,940
12,560
4,726
P110 HC
7,950
10,900
10,830
11,940
12,560
4,726
P110 EC
10,000
12,390
12,310
13,560
13,570
5,370
C110
7,950
10,900
10,830
11,940
11,560
4,726
Q125
8,440
12,390
12,310
13,560
13,570
5,370
Q125 HC
10,330
12,390
12,310
13,560
13,570
5,370
K55
630
2,250
2,250
2,540
2,820
1,367
N80
630
3,270
3,270
3,690
3,000
1,989
L80
630
3,270
3,270
3,690
3,430
1,989
L80 HC
630
3,270
3,270
3,690
3,430
1,989
C95/R95
630
3,880
3,880
4,380
3,820
2,362
P110
630
4,500
4,490
5,070
5,040
2,734
P110 HC
630
4,500
4,490
5,070
5,040
2,734
P110 EC
630
5,110
5,100
5,760
5,440
3,107
86
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
18 5/8 96.50
Area
PE
(lb/ft)
94.05
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
Rev 05.2011
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
8rd STC
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
K55
870
2,510
2,500
2,820
3,150
1,520
N80
870
3,650
3,640
4,100
3,350
2,211
L80
870
3,650
3,640
4,100
3,830
2,211
L80 HC
870
3,650
3,640
4,100
3,830
2,211
C95/R95
870
4,330
4,320
4,870
4,260
2,626
P110
870
5,010
5,010
5,640
5,630
3,040
P110 HC
870
5,010
5,010
5,640
5,630
3,040
P110 EC
870
5,700
5,690
6,410
6,080
3,455
K55
1,420
2,990
2,990
3,350
3,770
1,805
N80
1,500
4,350
4,340
4,880
4,010
2,626
L80
1,500
4,350
4,340
4,880
4,590
2,626
L80 HC
1,500
4,350
4,340
4,880
4,590
2,626
C95/R95
1,500
5,170
5,160
5,790
5,110
3,118
P110
1,500
5,980
5,970
6,710
6,750
3,611
P110 HC
1,500
5,980
5,970
6,710
6,750
3,611
P110 EC
1,500
6,800
6,790
7,620
7,290
4,103
K55
2,090
3,580
3,570
3,990
4,530
2,147
N80
2,480
5,210
5,200
5,810
4,820
3,123
L80
2,480
5,210
5,200
5,810
5,530
3,123
L80 HC
2,480
5,210
5,200
5,810
5,530
3,123
C95/R95
2,590
6,190
6,170
6,890
6,140
3,709
P110
2,610
7,160
7,140
7,980
8,120
4,294
P110 HC
2,610
7,160
7,140
7,980
8,120
4,294
P110 EC
2,610
8,140
8,120
9,070
8,770
4,880
K55
2,250
3,720
3,710
4,140
4,710
2,228
N80
2,710
5,410
5,400
6,020
5,020
3,240
L80
2,710
5,410
5,400
6,020
5,750
3,240
L80 HC
2,710
5,410
5,400
6,020
5,750
3,240
C95/R95
2,870
6,430
6,410
7,150
6,390
3,848
P110
2,930
7,440
7,420
8,280
8,450
4,455
P110 HC
2,930
7,440
7,420
8,280
8,450
4,455
P110 EC
2,930
8,460
8,430
9,410
9,120
5,063
87
Performance Data
Casing Dimensions & Minimum Performance Properties
OD
Wall
T&C
(in)
20
20
20
20
20
20
24
24
94.00
Area
PE
(lb/ft)
91.59
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
K55
520
2,110
2,110
2,380
2,640
1,480
2,110
824
2,110
955
9,540
2,110
1,479
K55
770
2,410
2,400
2,710
3,020
1,685
2,400
960
2,410
1,113
11,120
2,310
1,683
770
3,500
3,500
3,940
3,220
2,450
2,400
1,307
2,410
1,511
15,110
2,310
2,281
L80
770
3,500
3,500
3,940
3,680
2,450
2,400
1,296
2,410
1,497
14,970
2,310
2,259
L80 HC
770
3,500
3,500
3,940
3,680
2,450
2,400
1,296
2,410
1,497
14,970
2,310
2,259
K55
1,100
2,710
2,710
3,040
3,400
1,891
N80
1,110
3,940
3,930
4,430
3,630
2,750
L80
1,110
3,940
3,930
4,430
4,150
2,750
L80 HC
1,110
3,940
3,930
4,430
4,150
2,750
C95/R95
1,110
4,680
4,670
5,260
4,620
3,266
P110
1,110
5,420
5,410
6,090
6,100
3,782
K55
1,490
3,060
3,050
3,420
3,850
2,125
2,400
1,253
2,410
1,453
14,520
2,310
2,123
N80
1,600
4,450
4,440
4,980
4,100
3,091
2,400
1,707
2,410
1,973
19,730
2,310
2,877
L80
1,600
4,450
4,440
4,980
4,700
3,091
2,400
1,692
2,410
1,955
19,540
2,310
2,849
L80 HC
1,600
4,450
4,440
4,980
4,700
3,091
2,400
1,692
2,410
1,955
19,540
2,310
2,849
C95/R95
1,600
5,280
5,270
5,910
5,220
3,670
2,400
1,985
2,410
2,293
22,920
2,310
3,340
P110
1,600
6,110
6,100
6,840
6,900
4,249
2,400
2,309
2,410
2,667
26,670
2,310
3,887
K55
1,900
3,410
3,400
3,810
4,310
2,363
N80
2,190
4,960
4,950
5,540
4,590
3,437
L80
2,190
4,960
4,950
5,540
5,260
3,437
L80 HC
2,190
4,960
4,950
5,540
5,260
3,437
C95/R95
2,250
5,890
5,880
6,580
5,850
4,082
P110
2,250
6,820
6,810
7,620
7,720
4,727
K55
2,500
3,910
3,900
4,340
4,950
2,692
N80
3,020
5,680
5,670
6,310
5,270
3,916
L80
3,020
5,680
5,670
6,310
6,040
3,916
L80 HC
3,020
5,680
5,670
6,310
6,040
3,916
C95/R95
3,250
6,750
6,730
7,500
6,720
4,650
P110
3,370
7,820
7,790
8,680
8,890
5,384
K55
920
2,550
2,540
2,870
3,200
2,564
N80
920
3,700
3,700
4,170
3,410
3,729
K55
1,160
2,760
2,750
3,100
3,470
2,771
N80
1,170
4,010
4,010
4,510
3,700
4,031
L80
1,170
4,010
4,010
4,510
4,230
4,031
C95/R95
1,170
4,770
4,760
5,350
4,700
4,787
P110
1,170
5,520
5,510
6,200
6,210
5,543
8rd STC
N80
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
88
Rev 05.2011
Weight
Performance Data
Casing Dimensions & Minimum Performance Properties
Weight
OD
Wall
T&C
(in)
Area
PE
(lb/ft)
Pipe Body
Drift
(in)
(in2)
API
ALT.
(in)
(in)
K55
24
26
8rd LC
IP
JT
Strength
IP
BC
JT
Opt.
Strength Torque
IP
JT
Strength
(psi)
(psi)
(psi)
(psi)
(psi)
(kips)
(psi)
(kips)
(psi)
(kips)
(ft-lbs)
(psi)
(kips)
3,010
3,000
3,370
3,790
3,013
N80
1,530
4,380
4,370
4,900
4,040
4,383
L80
1,530
4,380
4,370
4,900
4,620
4,383
C95/R95
1,530
5,200
5,190
5,820
5,140
5,204
P110
1,530
6,020
6,000
6,740
6,780
6,026
K55
1,180
2,780
2,770
3,120
3,490
3,272
N80
1,190
4,040
4,030
4,530
3,720
4,760
L80
1,190
4,040
4,030
4,530
4,260
4,760
C95/R95
1,190
4,800
4,790
5,380
4,730
5,652
K55
1,440
3,010
3,000
3,370
3,780
3,534
N80
1,520
4,370
4,360
4,900
4,030
5,140
C95/R95
1,520
5,190
5,180
5,820
5,130
6,104
8rd STC
1,440
Rev 05.2011
26
Connection
IP
IP
IP
Grade
IP
Collapse (Barlow)
(Lam - (Lam - (Lam
ductile PBYS
open) capped) rupture)
89
90
Marking
Example 1: 9-5/8 53.50# Q125 Type 1 LTC
VMS
Inspection/SEA
white band
5CT-0019
grade
band
license
number
9-5/8
special end
OD
finish
size
API
monogram
manufacturer
SF
XXX
date of
manufacture
53.50
Q1
XXF
[ ] PXXXXX
LC
DA 8.500
[ ]
W/O XXXXXX
SLN XXXXXX
[ ] Made in USA
XX.X
XXXX
Heat Traceability
grade
nominal
wt/ft
(last digit of
year followed by
two digit month)
workorder
heat treatment
test
oversize
(quenched and
pressure
drift
heat
reduced tempered)
seamless
serialization
type of
number
alternative
process of
of C90, T95
supplementary thread
impact test
manufacture
and Q125
requirements if
temperature
applicable (SXX)
if applicable
PSL-2 or 3 if
applicable L2
or L3
weight
length
inspection/SEA
white band
Rev 05.2011
VMS 5CT-0019
Inspection/SEA
white band
manufacturer
grade
band
license
number
API
monogram
XXX SF 9-5/8
special end
finish
date of
manufacture
53.50
OD
size
(last digit of
year followed by
two digit month)
Q1
grade
nominal
wt/ft
XXF
[ ]
PXXXXX
VAM TOP
DA 8.500
heat treatment
test
(quenched and
pressure
reduced tempered)
seamless
type of
alternative
process of
supplementary thread
impact test
manufacture
requirements if
temperature
applicable (SXX)
if applicable
PSL-2 or 3 if
applicable L2
or L3
[ ]
W/O XXXXXX
alternate
drift
SLN XXXXXX
workorder
serialization
of C90, T95
and Q125
heat
number
[ ] Made in USA
XX.X
XXXX
length
any customeror manufacturercountry
weight
required
of origin
additional
stencil
inspection/SEA
white band
VMS
Inspection/SEA
white band
manufacturer
grade
band
91
license
number
5CT-0019
API
monogram
XXX SF 5-1/2
special end
finish
date of
manufacture
(last digit of
year followed by
two digit month)
OD
size
23.00
nominal
wt/ft
grade
XXF
reduced
alternative
impact test
temperature
if applicable
[ ]
PXXXXX
heat treatment
(quenched and
tempered)
seamless
process of
manufacture
VAM SG D
test
pressure
supplementary
requirements if
applicable (SXX)
PSL-2 or 3 if
applicable L2 or L3
[ ]
EC
drift
type of
thread
W/O XXXXXX
SLN XXXXXX
compatable
standards
serialization
of C90, T95
and Q125
workorder
heat
number
[ ] Made in USA
XX.X
XXXX
length
any customeror manufacturerweight
country
required
of origin
additional
stencil
inspection/SEA
white band
Color Codes
X
X
Grade Type
Coupling
Body
1. Band
2. Band
Pipe
3. Band
1. Band
2. Band
3. Band
green
4. Band
Pipe Body
Grade Type
Coupling
Body
1. Band
VM140
pink
VM150
Pipe
2. Band
3. Band
1. Band
2. Band
white
pink
white
grey
white
grey
VM125CY
orange
brown
VM130CY
orange
yellow
3. Band
4. Band
Pipe Body
Grade Type
Coupling
2. Band
Pipe
Body
1. Band
3. Band
1. Band
2. Band
3. Band
VM110HC
white
green
no marking
white
VM125HC
orange
green
no marking
orange
brown
VM140HC
pink
white
green
orange
yellow
VM80HCSS
red
green
orange
4. Band
pink
white
green
orange
red
green
orange
orange
J55 (tubing)
green
J55 (casing)
green
K55
green
green
N80 Type 1
red
red
N80 Q
red
green
red
green
VM80SS
red
orange
orange
red
orange
orange
VM95HCSS
brown
green
orange
orange
brown
green
orange
orange
L80
L80HC
L80HCE
red
brown
red
brown
VM90SS
purple
orange
orange
purple
orange
orange
VM110HCSS
white
green
orange
orange
white
green
orange
orange
white
green
X
X
C90 Type 1
C90HC
purple
purple
VM95SS
brown
orange
orange
brown
orange
orange
VM95R
brown
blue
blue
brown
blue
blue
C95/R95
brown
brown
VM110SS
white
orange
orange
white
orange
orange
VM110R
white
blue
blue
white
blue
blue
T95 Type 1
T95HC
T95E
T95HCE
silver
silver
VM125SS
orange
gray
gray
orange
gray
gray
VM125R
orange
blue
blue
orange
blue
blue
C110
white
VM95SS-D
brown
orange
orange
gray
brown
orange
orange
gray
VM95RSS
brown
blue
blue
orange
brown
blue
blue
orange
P110
P110EC
P110HCE
white
VM110SS-D
white
orange
orange
gray
white
orange
orange
gray
VM110RSS
white
blue
blue
orange
white
blue
blue
orange
P110MS
white
red
green
green
Q125 Type 1
Q125HC
Q125HCE
orange
brown
brown
white
brown
white
purple
white
orange
92
purple
brown
VM80HC
VM95HC
brown
green
X
X
X
X
X
no marking
no marking
93
94
Pipe Body