TESTING OF MATERIAL (COURSE SAND)
NAME OF WORK
SITUATION
BLOCK
DISTRICT
DATE OF SAMPLE TAKEN
MATERIAL
IDENTIFICATION MARK/QUARRY
PERMISSIBLE VALUE OF FINENESS MODULUS
2.20 to 3.60
WEIGHT OF SAMPLE TAKEN
Gram
Weight
Sl.
Sieve No.
No.
1.
2.
3.
4.
5.
6.
7.
Retained on
sieve in gm.
Wt. Passed
COURSE SAND
% Wt. retained
in gm.
Cumulative
Percentage
9.50 M.M
4.75 M.M
2.36 M.M
1.18 M.M
600 MICRON
300 MICRON
150 MICRON
Fineness Modulus : Sum of Percentage
100P
RESULT:-
Lab Technician
Data Technosys (Engineers) Pvt. Ltd.
TESTING OF MATERIAL (BRICKS)
NAME OF WORK
SITUATION
BLOCK
DISTRICT
DATE OF SAMPLE TAKEN
MATERIAL
IDENTIFICATION MARK/QUARRY
PERMISSIBLE
VALUE
OF
COMPRESSIVE
BRICK IS CLASS 150
150 KG/ CM2 (MIN)
STRENGTH
SL.
NO.
1
2
3
4
5
SAMPLE
NO.
B-1
B-2
B-3
B-4
B-5
COMPRESSIVE
STRENGTH
REMARK
Average Compressive Strength:
RESULT:-
Lab Technician
Data Technosys (Engineers) Pvt. Ltd.
TESTING OF MATERIAL (FINE SAND)
NAME OF WORK
SITUATION
BLOCK
DISTRICT
DATE OF SAMPLE TAKEN
MATERIAL
IDENTIFICATION MARK/QUARRY
PERMISSIBLE VALUE OF FINENESS MODULUS
1.25 1.90
WEIGHT OF SAMPLE TAKEN
Gram
Sl.
No.
1.
2.
3.
4.
5.
6.
7.
Weight
Sieve No.
Retained on
sieve in gm.
Wt. Passed
FINE SAND
% Wt. retained
in gm.
Cumulative
Percentage
9.50 M.M
4.75 M.M
2.36 M.M
1.18 M.M
600 MICRON
300 MICRON
150 MICRON
Fineness Modulus : Sum of Percentage
100P
RESULT:-
Lab Technician
Data Technosys (Engineers) Pvt. Ltd.
TESTING OF MATERIAL (CEMENT CONCRETE)
NAME OF WORK
SITUATION
BLOCK
DISTRICT
ITEM OF WORK
:
:
:
:
:
CEMENT CONCRETE
MIX GRADE
DATE OF SAMPLE TAKEN
IDENTIFICATION MARK/QUARRY
PERMISSIBLE VALUE
After 7 days
After 28 days
:
:
:
:
M-20
135-175 KG/CM2
200 265 KG/CM2
STRENGTH
Sl.
IDENTIFICATION
No.
OF CUBE
1.
2.
3.
4.
5.
6.
P-1
P-2
P-3
P-4
P-5
P-6
AVERAGE VALUE
DAMP
STRENGTH
AFTER 7 DAYS
CURING
FULL STRENGTH
AFTER 28 DAYS
CURING
REMARK
RESULT:-
Lab Technician
Data Technosys (Engineers) Pvt. Ltd.
TESTING OF MATERIAL GRID (20 mm stone grid)
NAME OF WORK
SITUATION
BLOCK
DISTRICT
DATE OF SAMPLE TAKEN
STAGE
MATERIAL
IDENTIFICATION MARK/QUARRY
WEIGHT OF SAMPLE TAKEN
20 MM Stone Grid
Gram
Sl.
No.
Weight
Sieve No.
Wt. Passed
Percentage
in gm.
Passed in gm.
Retained on
sieve in gm.
Permissible
Percentage
Passing
1.
40 M.M
100
2.
20 M.M
95 100
3.
16 M.M
4.
12.5 M.M
5.
10 M.M
25 55
6.
4.75 M.M
6 10
Lab Technician
Data Technosys (Engineers) Pvt. Ltd.
TESTING OF MATERIAL GRID (16 mm stone grid)
NAME OF WORK
SITUATION
BLOCK
DISTRICT
DATE OF SAMPLE TAKEN
STAGE
MATERIAL
IDENTIFICATION MARK/QUARRY
WEIGHT OF SAMPLE TAKEN
Sl.
No.
Weight
Sieve No.
16 MM Stone Grid
Gram
Wt. Passed
Percentage
in gm.
Passed in gm.
Retained on
sieve in gm.
Permissible
Percentage
Passing
1.
40 M.M
2.
20 M.M
100
3.
16 M.M
90 100
4.
12.5 M.M
5.
10 M.M
30 70
6.
4.75 M.M
0 10
Lab Technician
Data Technosys (Engineers) Pvt. Ltd.