CLIENT

PROJECT
SITE
KEY
X
PACKAGE
TITLE:
TAG NUMBER: V1010 A/B/C REQN. NUMBER:
?
S.No. UNITS
1.0 GENERAL
1401010 MAP90235/BD/001
? FMC Technologies ? National Oilwell Varco ?
? To be confirmed ? To be confirmed ?
? To be confirmed ? To be confirmed ?
? To be confirmed ? To be confirmed ?
? To be confirmed ? To be confirmed ?
? To be confirmed ? To be confirmed ?
? To be confirmed ? To be confirmed ?
? To be confirmed ? To be confirmed
? To be confirmed ? To be confirmed ?
2.0
2.1
? ASME SEC VIII Div 1 ASME SEC VIII Div 1
barg 75 and Full Vacuum Yes ? To be confirmed
C Minus(-50)/60 Yes ? To be confirmed
To S-A00-1351-001 ? To be Confirmed ? To be confirmed
To S-A00-1351-001 ? To be Confirmed ? To be confirmed
To S-A00-1351-001 ? To be Confirmed ? To be confirmed
To S-A00-1351-001 ? To be Confirmed ? To be confirmed
Required Provided ? Not Provided
2.2
m3/hr
Oil Inlet Density kg/m3
Oil Inlet Viscosity cP
Water Inlet Flowrate m3/hr
Water Inlet Density kg/m3
cP
m3/hr
kg/kmol
cP
m3/hr
m3/hr
m3/hr
ptb
kg/m3
m
2.3
C
barg
C
barg
barg
mm
mm
mm
1119.53
Gas Viscosity
Gas Outlet Flow Rate
10.03
10% of liquid flow rate
20.49
0.015 @ 88 barg
VTA
VTA
VTA
TECHNICAL BID EVALUATION SUMMARY
76 / FV
INLET SEPARATOR
EM1402 Rev. 2
ASME SEC VIII Div 1
eProcess
To be confirmed
To be confirmed
eProcess FMC Technologies National Oilwell Varco
ASME SEC VIII Div 1/2
SPECIFICATION REQUIREMENTS
612.3
87.71
0.244
14.64
To be confirmed
To be confirmed
To be confirmed
-50 / 70
To be confirmed
To be confirmed
To be confirmed
To be confirmed
To be confirmed
To be confirmed
To be confirmed
Conformance to Process Engg.Flow Scheme-Inlet Separator
Conformance to Packaged Equipment General Design Philosophy and Specification
Provision of Documents as per SDRL
DESIGN REQUIREMENTS
Mechanical Design
Relavent P&IDs
Code
Design Pressure
Design Temperature
Wind Load design
Blast Load Design
Transportation Loading Design
All other loadings
Mechanical datasheet by Vendor
Process Design
Oil Inlet Flowrates
Design Data
Water Inlet Viscosity
Gas Inlet Flow Rate
Gas Molecular Weight
Water Outlet Flow Rate
Oil Outlet Flow Rate
Particle Loading
Particle Average Density
Particle Range
5 to 64
2000
10 to 150
Operating Temprature
Operating Pressure
Design Temprature (Min / Max)
Design Pressure (Min / Max)
Test Pressure
Cone Height
S-A00-135A-001
Number of Liners
Diameter (ID)
Cylinder Height
-15 to 25.5
69 to 88
-50 / 60
FV / 105
VTA
VTA
VTA
VTA
VTA
DESCRIPTION
Quotation Ref. / Date
Vessel manufacturer
Conformance to Inlet Separator Mechanical Spec.
Conformance to Pressure Vessel Gen.Design Philosophy &Spec
Conformance to Inlet Separator Datasheet
Conformance to Basic Engineering Design Data
To be confirmed
Doc No.: 247580616.xls.ms_office 10/15/2014 Page 1 of 8
CLIENT
PROJECT
SITE
KEY
X
PACKAGE
TITLE:
TAG NUMBER: V1010 A/B/C REQN. NUMBER:
?
S.No. UNITS
TECHNICAL BID EVALUATION SUMMARY
INLET SEPARATOR
eProcess FMC Technologies National Oilwell Varco SPECIFICATION REQUIREMENTS DESCRIPTION
mm
mm
mm
m3
Turndown
3.0 CONSTRUCTION
Vessel Dimensions ? 1800 : 4600 ? 1700 : 4500 ?
Vessel Thickness(Shell/Head) mm 64 / 56 56 / 54
Post Weld Heat Treatment Yes Yes
External Painting As per Data Sheet & Spec ? Yes Yes
Internal Coating Not Required
Internal clad /overlay with SS316L upto wetted height of vessel m As per Data Sheet Upto 2.1 m height-OK X
1.5 m not sufficient-Min. Upto 2.1 m height
required.
Anode Provision against galvanic corrosion ? To be confirmed ? To be confirmed
Provision of ext. attachments-cleats, pipe supports etc Yes Yes
2:1 Heads As per Data Sheet & Spec Confirmed ? 2:1 SE Head
Skirt height mm As required 2000 ? Not Provided
Skirt ring height ? Not Provided ? Not Provided
4.0 MATERIALS
Vessel
Shell / Head plates SA516 70N + 316L OL SA516 70N + 316L OL
Internals/attachments SS316L SA516 70N + 316L OL To be Confirmed
Flange Bolting SA 320 Gr.L7/SA 194 L7 ? To be Confirmed To be Confirmed
Fluoro Carbon Coating for flange bolts As per datasheet ? To be Confirmed To be Confirmed
Nozzle Flange SA350 Gr LF2 SA182F316L To be Confirmed
Nozzle Pipe SA333 Gr 6
SA312TP316L (D<10")
SA516 70N + 316L OL (D 12"& Larger)
To be Confirmed
Pipe fittings SA420 WPL 6 SA403WP316L SA403WP316L
External attachments SA 516 Gr. 70 N
SA516 70N + 316L OL (Direct Welded)
Carbon Steel (Indirect Welded)
SA516 70N + 316L OL (Direct Welded)
Carbon Steel (Indirect Welded)
Nozzle Gaskets SS316L SWSF ? To be Confirmed To be Confirmed
Cladding on nozzles and flanges upto wetted height SS316L ? To be Confirmed To be Confirmed
Vessel shall meet NACE MR0175 & ISO 15156 As per Data Sheet & Spec ? To be Confirmed To be Confirmed
Anode requirements As per Data Sheet & Spec ? To be Confirmed To be Confirmed
4.2 Vessel Internals
Design & Supply of Vessel Internals ?
Assembly of Internals ? To be confirmed To be Confirmed ?
All
inte
rnal
? To be confirmed To be confirmed ?
5.0 GUARANTEE
Mechanical Guarantee As per Data Sheet & Spec ? To be confirmed Provided
6.0 QUALITY REQUIREMENTS
Material Certification As per datasheet ? To be confirmed EN 10204 Type 3.1 / EN 10204 Type 2.2
As per Data Sheet & Spec
Required by Vessel Fabricator
To be Confirmed by Vessel Vendor
/Internals Vendor
SA 516 Gr. 70 N or Equivalent to suit Minus
(-)50 Design Temperature
Yes
50 / 52
To be confirmed
To be Confirmed
To be confirmed
To be Confirmed
As per data sheet
To be Confirmed
Yes
As per code and datasheet
To be Confirmed
To be Confirmed
To be Confirmed
Not Required by Vessel Fabricator
By Vendor
ID 1800: 4700 L T/T
To be Confirmed
To be Confirmed
To be Confirmed
Not Provided
1800 : 4600
SA105 ASME B16.5
SA516 70N Clad 316L Plate
To be Confirmed
To be Confirmed
Wall Thickness Head
Corrosion Allowance
Joint Efficiency
Insulation Thickness
Vessel Orientation
Normal Liquid Volume
VTA
VTA
VTA
To be confirmed
2:1 SE Head
500
N/A
Vertical
VTA
Note 10
EN 10204 Type 3.1 / EN 10204 Type 2.2
18 mth delivery / 12 mth after commissioning
Doc No.: 247580616.xls.ms_office 10/15/2014 Page 2 of 8
CLIENT
PROJECT
SITE
KEY
X
PACKAGE
TITLE:
TAG NUMBER: V1010 A/B/C REQN. NUMBER:
?
S.No. UNITS
TECHNICAL BID EVALUATION SUMMARY
INLET SEPARATOR
eProcess FMC Technologies National Oilwell Varco SPECIFICATION REQUIREMENTS DESCRIPTION
Welding,Testing & NDE As per Data Sheet & Spec Yes Yes
Hydro Test As per Data Sheet, Spec and Code Yes Yes ?
Third Party Inspection By SUPPLIER ? To be confirmed To be confirmed
Quality Systems Required ? Not Specified To be confirmed
ASME Code Stamp Requirements Required ASME (S, U, U2) where required Yes
PMI for Vessel Cladding Required ? To be confirmed To be confirmed
100% RT As per Data Sheet & Spec ? To be confirmed To be confirmed
UT As per Data Sheet, Spec and Code ? To be confirmed To be confirmed
MT &PT As per Data Sheet & Spec ? To be confirmed To be confirmed
Impact Test for materials AS per Code ? To be confirmed To be confirmed
7.0 WEIGHT DATA
Empty Weight kg Vendor to specify 23,119 22,060
Operating Weight kg Vendor to specify ? Not Provided Not Provided
Hydrotest Weight kg Vendor to specify 38,119 Not Provided
8.0 SPARES
Supply of Start-up &Commissioning Spares As per Data Sheet & Spec ? Not Provided Provided ?
List of 2 years Spares As per Data Sheet & Spec ? Not Provided Not Provided ?
9.0
10.0 DEVIATIONS
Vendor to bringout all deviations specifically
11.0 EXPERIENCE RECORD
12.0 OVERALL TECHNICAL ACCEPTABILITY
13.0 TECHNICAL RANKING
Not Provided
Not Provided
To be confirmed
Deviations if any
Yes
Not Provided
Yes
23,400
Not Provided
Confirmed
To be confirmed
Confirmed
To be confirmed
To be confirmed
To be confirmed
Not Provided
Doc No.: 247580616.xls.ms_office 10/15/2014 Page 3 of 8
CLIENT
PROJECT
SITE
KEY
X
PACKAGE
TITLE:
TAG NUMBER: V1010 A/B/C REQN. NUMBER:
?
S.No. UNITS
TECHNICAL BID EVALUATION SUMMARY
INLET SEPARATOR
eProcess FMC Technologies National Oilwell Varco SPECIFICATION REQUIREMENTS DESCRIPTION
REMARKS :
Doc No.: 247580616.xls.ms_office 10/15/2014 Page 4 of 8
JGC AND SHI
12P002 - PETRONAS FLNG 2 PROJECT
Offshore Malaysia
Acceptable / Included
Not Acceptable
Requires Further Clarification
76 / FV
EM1402 Rev. 2
ASME SEC VIII Div 1
eProcess
To be confirmed
To be confirmed
eProcess
To be confirmed
To be confirmed
To be confirmed
-50 / 70
To be confirmed
To be confirmed
To be confirmed
To be confirmed
To be confirmed
To be confirmed
To be confirmed
To be confirmed
Doc No.: 247580616.xls.ms_office 10/15/2014 Page 5 of 8
JGC AND SHI
12P002 - PETRONAS FLNG 2 PROJECT
Offshore Malaysia
Acceptable / Included
Not Acceptable
Requires Further Clarification
eProcess
Yes
50 / 52
To be confirmed
To be Confirmed
To be confirmed
To be Confirmed
To be Confirmed
Yes
To be Confirmed
To be Confirmed
To be Confirmed
To be Confirmed
To be Confirmed
To be Confirmed
Not Provided
1800 : 4600
SA105 ASME B16.5
SA516 70N Clad 316L Plate
To be Confirmed
To be Confirmed
To be confirmed
2:1 SE Head
500
EN 10204 Type 3.1 / EN 10204 Type 2.2
18 mth delivery / 12 mth after commissioning
Doc No.: 247580616.xls.ms_office 10/15/2014 Page 6 of 8
JGC AND SHI
12P002 - PETRONAS FLNG 2 PROJECT
Offshore Malaysia
Acceptable / Included
Not Acceptable
Requires Further Clarification
eProcess
Not Provided
Not Provided
To be confirmed
Yes
Not Provided
Yes
23,400
Not Provided
Confirmed
To be confirmed
Confirmed
To be confirmed
To be confirmed
To be confirmed
Not Provided
Doc No.: 247580616.xls.ms_office 10/15/2014 Page 7 of 8
JGC AND SHI
12P002 - PETRONAS FLNG 2 PROJECT
Offshore Malaysia
Acceptable / Included
Not Acceptable
Requires Further Clarification
eProcess
Doc No.: 247580616.xls.ms_office 10/15/2014 Page 8 of 8