You are on page 1of 1

TC24

TURBOCHARGING

VSV FOR TURBOCHARGING PRESSURE CONTROL

INSPECTION
1.

Ohmmeter

TC00X02

REMOVE VSV

2.
INSPECT VSV FOR OPEN CIRCUIT
Using an ohmmeter, check that the there is continuity between
the terminals.
Resistance: 37 44 W at 20C (68F)
If there is no continuity, replace the VSV.

Continuity
B08188

Ohmmeter

No Continuity

3.
INSPECT VSV FOR GROUND
Using an ohmmeter, check that there is no continuity between
each terminal and the body.
If there is continuity, replace the VSV.

B08189

4.
(a)

Air

INSPECT VSV OPERATION


Check that air does not flow from port E to G.

E
G

B08190

(b) Apply battery voltage across the terminals.


(c) Check that air flows from port E to filter.
If operation is not as specified, replace the VSV.
5.
REINSTALL VSV

Air
Filter
E

Battery
1CDFTV ENGINE (RM697E)

B08191