You are on page 1of 1

Operation timing diagram

Within 7ms

Power

Within T1

Optical switch light sensor


Output relay (X1)

T1 = fixed at 1 second

Motor
External input signal for
screw feed(1P 3P)
(during selector SW ON)
Output relay (X2)
Solenoid valve
(during selector SW OFF)
Output relay (X2)

T2:0.1

Solenoid valve

Output relay (X1): Operates linked to the optical switch


Output relay (X2): Operates linked to the screw feed external input signal
Timer (T1): Motor gear head stop delay time
Timer (T2): Used to adjust the screw feed time (solenoid valve)
Note: Selector switch should be ON for Handy, and OFF for Auto Feeder.

Screw-feed external input signal selector


Switch S1 is used to set valve operation
ON (retrigger mode): For Handy (Screw feed external input signal resets the timer time.)
OFF (sync mode): For auto machine operation (Solenoid valve opens and closes in synchronization
with screw feed external input signal.)

S1: Valve operation setting switch