Aulia El Hakim, S.ST.,M.T
PURPOSE
• Pembahasan Soal UTS !
• Pembahasan Soal Tugas !
• Memahami konsep Timer Operation pada Siemens S7-300
OUTLINE

Pembahasan Soal UTS

Pembahasan Soal Tugas note-7

TIMER OPERATION
HARDWARE PLC SIEMENS S7-300
MODUL Tipe ID Number
Power Supply ( PS) PS 307 2A 307-1BA01-0AA0
CPU CPU315-2DP 315-2AH14-0AB0
Digital input (DI) DI 16 X DC24 V 321-1BH02-0AA0
Digital Output (DO) DO 16XDC24V / 0.5A 322-1BH01-0AA0
Analaog Input (AI) AI 2X12BIT 331-7KB02-0AB0
Analaog Output (AO) AO 2X12BIT 332-5HB01-0AB0
HASIL UTS 3-A
HASIL UTS 3-B
HASIL UTS 3-C
Pembahasan Soal UTS !
Pembahasan Soal Tugas Note-8 /2!
• A trolley will move in the other direction if it stops in any end position and the start switch is excited. When
it warns the limit switch on the opposite side, it will return to the direction it came from. This movement will
continue until the warning of the start switch is removed. When the start switch is turned off, it will arrive at
its last location and wait there.
• Power failure, breakdown etc. If the car is left in the middle for reasons, it will continue in the same direction
as when the energy comes (use Non-volatile memory--- retain memory)

Detent
Switch
Solution
TIMER OPERATION
Size and range of the TIME data type

Note:The negative range of the TIME data type shown above cannot be used with the timer instructions. Negative PT (preset time)
values are set to zero when the timer instruction is executed. ET (elapsed time) is always a positive value.
Timer operations

materi Retooling PLC -festo turki


Timer operations

materi Retooling PLC -festo turki


Timer operations

materi Retooling PLC -festo turki


Contoh:
• The control of a pneumatic press shall be realized by PLC. When the start button is pressed, the press head will go down, it
will go up 3 seconds after it is completely lowered.
• A double-acting cylinder will be used for the movement of the press head and a spring-centered, mid-position closed 5/3
valve for the control of the cylinder.
• Write the PLC program.

OPERAND SYMBOL COMMENT

I 0.0 Start Start button


I 0.1 Press Up Sensor Press head above (S1)
I 0.2 Press Down Sensor Press Head Below (S2)
Q 0.0 Press Down Press head down (Y1)
Q 0.1 Press Up Press head up (Y2)
Solution

Q 0.0 → (Y1) Q 0.1 → (Y2)


Tugas !
• The following SYSTEM will start to operate when the START (I 0.0) BUTTON is pressed.
The Stop (I 0.1) Button will continue to Cycle Up To PRESSURE.